MOTORIZED STEEL BELLS
BL-6B/BL-10B
Features
Description
Low current draw (20 mA)
6 and 10 inch diameter steel shells for long term
reliability
RFI and EMF suppression prevents noise
problems to the fire alarm control panel
Polarized for DC supervision
Pigtail connection
Standard 4 inch square electrical box
mounting
Weatherproof backbox available for outdoor
applications
Red finish
Dimensions
Mircoms BL-6B and BL-10B Motorized Steel Bells
are designed for todays fire alarm applications. The
durable steel construction provides loud resonant
tones necessary for fire alarm installations.
The BL-6B and BL-10B bells use a varistor
suppression element to prevent RFI and EMF noise
problems to modern fire alarm control panels.
The motor used on the BL-6B and BL-10B bells
operate at a very low current (20 mA) to maximize
the number of bells per circuit. Both models are
equipped with a pigtail connection for wiring.
Both the BL-6B and BL-10B mount on a standard
4 square electrical box for indoor use or on a
BB-206WP weatherproof backbox for outdoor
applications. Mounting on a 4 octagon outlet box
requires the MP-101 Universal Mounting Plate.
S5375
S5375
7135-1477:152
CATALOG NUMBER
NOT TO BE USED FOR INSTALLATION PURPOSES.
5261
Mircom reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models.
Installation Instructions
4 SQUARE OUTLET BOX
WIRING (REAR VIEW)
D.C. BELLS (OBSERVE POLARITY)
GASKET FOR
MOUNTING
ON SURFACE OR
WEATHERPROOF
BACKBOX
STRIKER
HEX-BOLT
GONG
HORIZONTAL AXIS
NO MORE
THAN -6dB
NO MORE
THAN -6dB
BB-206WP
WEATHERPROOF
BACKBOX
5"
Installation Instructions:
1.
2.
3.
4.
5.
6.
Remove the bell.
Wire the bell in the circuit.
Mount ball mechanism on 4 square standard outlet box with
the striker facing down.
Replace the bell.
The bell must be mounted a minimum of 8 ft. above the floor,
or as close to the ceiling as possible.
Polarized bell provides red(+) and black(-) lead wires.
When you install the bell, polarity must be observed.
Caution:
When electrical supervision is required, use in and out leads as shown.
Notes:
1.
2.
3.
4.
5.
6.
7.
Observe polarity.
Red wires positive (+).
Black wires negative (-).
For installation in Canada, installation must comply to
Canadian Electrical Code, Part 1, ULC-S524-01, the standard
for the installation of fire alarm system, and only subject to
final acceptance of local AHJ.
For indoor use: Motor fire bell only.
For outdoor use: Motor fire alarm bell attached to waterproof
box only.
Mounting to a 4 octagon box requires MP-101 mounting plate.
Specifications
Model
Description
Voltage
Rated Current
BL-6B
6 Motorized Steel Bell
24 VDC
20 mA
Sound Level at 10 ft. dB
85
BL-10B
10 Motorized Steel Bell
24 VDC
20 mA
85
Ordering Informtion
Model
Description
BL-6B
6 Motorized Steel Bell
BL-10B
10 Motorized Steel Bell
Accessories
BB-206WP
Weatherproof Backbox
MP-101
Universal Mounting Plate
M-1995
Yard Hood
SG-210
Grill for 10 Bell Backbox
SG-210S
Brushed Stainless Steel Grill for 10 Backbox
NOT TO BE USED FOR INSTALLATION PURPOSES.
Distributed by:
Canada
25 Interchange Way
Vaughan, Ontario L4K 5W3
Telephone: (905) 660-4655
Fax: (905) 660-4113
Web page: http://www.mircom.com
U.S.A.
4575 Witmer Industrial Estates
Niagara Falls, NY 14305
Toll Free: (888) 660-4655
Fax Toll Free: (888) 660-4113
Email: mail@mircom.com
CAT. 5261
Rev. 2