Product data sheet
Characteristics
LC1D95M7
TeSys D contactor - 3P(3 NO) - AC-3 - <= 440
V 95 A - 220 V AC coil
Mar 9, 2013
Range of product
TeSys D
Product or component
type
Contactor
Device short name
LC1D
Contactor application
Motor control
Resistive load
Utilisation category
AC-1
AC-3
Poles description
3P
Power pole contact
composition
3 NO
[Ue] rated operational
voltage
<= 1000 V AC for power circuit
<= 300 V DC 25...400 Hz for power circuit
[Ie] rated operational
current
95 A (<= 60 C) at <= 440 V AC AC-3 for power circuit
125 A (<= 60 C) at <= 440 V AC AC-1 for power circuit
Motor power kW
45 kW at 380...400 V AC 50/60 Hz
25 kW at 220...230 V AC 50/60 Hz
45 kW at 1000 V AC 50/60 Hz
45 kW at 660...690 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
45 kW at 415...440 V AC 50/60 Hz
Motor power HP (UL /
CSA)
60 hp at 575/600 V AC 50/60 Hz for 3 phases motors
60 hp at 460/480 V AC 50/60 Hz for 3 phases motors
25 hp at 230/240 V AC 50/60 Hz for 3 phases motors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
7.5 hp at 115 V AC 50/60 Hz for 1 phase motors
20 hp at 200/208 V AC 50/60 Hz for 3 phases motors
Control circuit type
AC 50/60 Hz
Control circuit voltage
220 V AC 50/60 Hz
Auxiliary contact composition
1 NO + 1 NC
[Uimp] rated impulse
withstand voltage
8 kV conforming to IEC 60947
Overvoltage category
III
[Ith] conventional free
air thermal current
125 A at <= 60 C for power circuit
10 A at <= 60 C for signalling circuit
Irms rated making capacity
1100 A at 440 V for power circuit conforming to IEC
60947
250 A DC for signalling circuit conforming to IEC
60947-5-1
140 A AC for signalling circuit conforming to IEC
60947-5-1
Rated breaking capacity
1100 A at 440 V for power circuit conforming to IEC
60947
[Icw] rated short-time
withstand current
400 A <= 40 C 1 min power circuit
800 A <= 40 C 10 s power circuit
135 A <= 40 C 10 min power circuit
140 A 100 ms signalling circuit
120 A 500 ms signalling circuit
100 A 1 s signalling circuit
1100 A <= 40 C 1 s power circuit
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein.
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications.
It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof.
Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.
Main
Associated fuse rating
160 A gG at <= 690 V coordination type 2 for power
circuit
200 A gG at <= 690 V coordination type 1 for power
circuit
10 A gG for signalling circuit conforming to IEC
60947-5-1
Average impedance
0.80 mOhm at 50 Hz - Ith 125 A for power circuit
[Ui] rated insulation
voltage
1000 V for power circuit conforming to IEC
60947-4-1
600 V for signalling circuit certifications UL
600 V for signalling circuit certifications CSA
690 V for signalling circuit conforming to IEC
60947-1
600 V for power circuit certifications UL
600 V for power circuit certifications CSA
Electrical durability
1.3 Mcycles 125 A AC-1 at Ue <= 440 V
1.2 Mcycles 95 A AC-3 at Ue <= 440 V
Power dissipation per
pole
7.2 W AC-3
12.5 W AC-1
Safety cover
With
Mounting support
Plate
Rail
Standards
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
CSA C22.2 No 14
Product certifications
BV
CCC
DNV
GL
GOST
RINA
LROS
Connections - terminals
Power circuit: connector 2 cable(s) 4...25 mm - cable stiffness: solid - without cable end
Power circuit: connector 1 cable(s) 4...50 mm - cable stiffness: solid - without cable end
Power circuit: connector 2 cable(s) 4...16 mm - cable stiffness: flexible - with cable end
Power circuit: connector 1 cable(s) 4...50 mm - cable stiffness: flexible - with cable end
Power circuit: connector 2 cable(s) 4...25 mm - cable stiffness: flexible - without cable end
Power circuit: connector 1 cable(s) 4...50 mm - cable stiffness: flexible - without cable end
Control circuit: screw clamp terminals 1 cable(s)
1...2.5 mm - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminals 2 cable(s)
1...4 mm - cable stiffness: solid - without cable end
Control circuit: screw clamp terminals 1 cable(s)
1...4 mm - cable stiffness: solid - without cable end
Control circuit: screw clamp terminals 2 cable(s)
1...2.5 mm - cable stiffness: flexible - with cable end
Control circuit: screw clamp terminals 2 cable(s)
1...4 mm - cable stiffness: flexible - without cable
end
Control circuit: screw clamp terminals 1 cable(s)
1...4 mm - cable stiffness: flexible - without cable
end
Tightening torque
Power circuit: 9 N.m - on connector hexagonal 4 mm
Power circuit: 9 N.m - on connector - with screwdriver flat 6 to 8 mm
Control circuit: 1.2 N.m - on screw clamp terminals with screwdriver Philips No 2
Control circuit: 1.2 N.m - on screw clamp terminals with screwdriver flat 6 mm
Operating time
6...20 ms opening
20...35 ms closing
Safety reliability level
B10d = 20000000 cycles contactor with mechanical
load conforming to EN/ISO 13849-1
B10d = 1369863 cycles contactor with nominal load
conforming to EN/ISO 13849-1
Mechanical durability
4 Mcycles
Operating rate
3600 cyc/h at <= 60 C
Complementary
Coil technology
Without built-in suppressor module
Control circuit voltage limits
0.85...1.1 Uc at 55 C operational 60 Hz
0.8...1.1 Uc at 55 C operational 50 Hz
0.3...0.6 Uc at 55 C drop-out 50/60 Hz
Inrush power in VA
245 VA at 20 C (cos 0.75) 50 Hz
245 VA at 20 C (cos 0.75) 60 Hz
Hold-in power consumption in VA
26 VA at 20 C (cos 0.3) 50 Hz
26 VA at 20 C (cos 0.3) 60 Hz
Heat dissipation
6...10 W at 50/60 Hz
Auxiliary contacts type
Type mirror contact (1 NC) conforming to IEC 60947-4-1
Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
Signalling circuit frequency
25...400 Hz
Minimum switching current
5 mA for signalling circuit
Minimum switching voltage
17 V for signalling circuit
Non-overlap time
1.5 ms on energisation (between NC and NO contact)
1.5 ms on de-energisation (between NC and NO contact)
Insulation resistance
> 10 MOhm for signalling circuit
Environment
IP degree of protection
IP2x front face conforming to IEC 60529
Protective treatment
TH conforming to IEC 60068-2-30
Pollution degree
Ambient air temperature for operation
-5...60 C
Ambient air temperature for storage
-60...80 C
Permissible ambient air temperature around the device
-40...70 C at Uc
Operating altitude
3000 m without derating in temperature
Fire resistance
850 C conforming to IEC 60695-2-1
Flame retardance
V1 conforming to UL 94
Mechanical robustness
Shocks contactor closed 10 Gn for 11 ms
Shocks contactor open 8 Gn for 11 ms
Vibrations contactor closed 3 Gn, 5...300 Hz
Vibrations contactor open 2 Gn, 5...300 Hz
Height
127 mm
Width
85 mm
Depth
130 mm
Product weight
1.61 kg
Contractual warranty
Period
18 months