Starter System
www.firstechonline.com | www.compustar.com
STARTIT Details
( - ) Switch
3 Gray
( + ) Led
2 Gray
( - ) Led
1 Gray/Black
LED ( + )
Black / White
LED ( - )
Black
(-)
4 Black
(+)
3 White
TX
2 Red
RX
2: ( + ) Parking Light
3 Red/White
4 White
3: ( + ) 12v Constant Red / White
nd
prewired to 2 Relay
4: ( + ) Accessory
5 Violet
6 Yellow
5: ( - ) When Armed prewired to
Anti-Grind Relay
6: ( + ) Starter prewired to
Anti-Grind Relay
7 Green and
Red
8 Black
7: ( + ) Ignition Red prewired to
Anti-Grind Relay
8: ( - ) Ground
Please see the installation manual
for the Blade module for details.
This harness is not
included with the CM5200.
ADS Blade Connector
(20 Pin Harness)
CN8
Antenna
CN3
1 Green / White
2 Lt Blue
1: ( - ) Parking Lt. Output POC 1
2: ( - ) E-Brake Input
3 Red / Black
4 Lt. Blue /
White
3: ( - ) Starter Output POC 2
4: ( + ) Brake Input
5 Green
6 Violet / Black
5: ( - ) Ignition Output POC 3
6: ( - ) Trunk Input
7 White / Black
8 Red / White
7: ( - ) Accessory Output POC 4
8: ( - ) Door Input
9 Black
10 Brown /
White
9: ( - ) Status Out (GWR) POC 5
11 Orange
12 Pink
11: ( - ) Rearm Output POC 6
13 Orange /
White
14 Yellow /
Black
16 Gray /
Black
15 White
4(-)
2 Data
1: ( + ) 12v Constant
CN1
CN5
LED
1 Yellow
3(+)
2 Green /
White
1 Red
CN9
Plug In
LED/Valet
Switch
17 Violet
CN12
RS232
18 Brown
13: ( - ) Disarm Output POC 7
10: ( - ) Glow Input/Key
Sensing
12: ( - ) Slave/Closed Loop
Input
14: (AC) Tach / Alternator
Input
15: ( - ) Horn Output POC 8
16: ( - ) Hood Input
17: ( - ) Dome Light POC 9
18: ( + ) Siren Output
1 Data
CN11
Thermistor
( + ) 12v
Constant Power
1 Black / White
2 Black
None
( - ) Lock Output
( - ) Unlock
Output
( - ) Second
Unlock Output
( - ) Trunk
release output
5 Blue / Black
Future use
None
4 Blue
3 Orange /
Black
2 Violet /
White
CN4
Green/White Loop
Cut=Auto Trans. Uncut=Manual
Trans.
(+)
Blade Cartridge Slot - Please visit
www.idatalink.com/compustar for
compatibility and more information. This
slot is empty and has a plastic cover that
slides off.
IMPORTANT: Manufacturer or seller will have
no responsibility for any injuries and/or
damages caused by improper care of the
product such as decomposition, conversion,
and transform done by a user voluntarily.
Jumpers
(+)
(-)
Default
( + ) Parking
Lights
Default
Copyright 2009 Firstech, LLC.
(-)
Default
Trunk Release
Every control module has this wire
intact and must be cut for automatic
Door Trigger Polarity
Key Sense/Glow Plug Polarity
Behavior of CN1, Pin 2
Page 1
Starter System
www.firstechonline.com | www.compustar.com
STARTIT Details
Option Tables
Feature
1-02
1-03
1-04
Unlock before, Lock after,
starting
Lock / Unlock pulse duration
Driver's priority unlock
Double pulse unlock
1-05
Rearm Output
1-06
Reservation Lock (Manual
transmissions)
1-01
1-07
1-08
Unlock / Disarm With Trunk
Release
Locking while in Passive
Arming
STARTIT
Option Group 1
Default Setting - I
Optional Setting - II
Off
On
0.8 sec
Off
Off
After Start Shutdown
and First Lock
2.5 sec
On
On
After Start Shutdown
and Every Lock
Locks When Reservation Mode is Set
Does Not Lock When
Reservation is Set
Unlock, Factory Dis- Factory Disarm, Trunk
arm, and Trunk Release
Release Only
Passive locking with
No Passive Locking
Passive Arming
with Passive Arming
Optional Setting - III
Optional Setting - IV
Lock After Remote
Start Only
0.125 sec
Lock After Shutdown
Only
3.5 sec
After Start Only
After Shutdown Only
Reservation Sets 10
Seconds After the Last
Door is Closed
Trunk Release Only
1-09
Ignition controlled door locks
Off
On
RPM Locks (Tach
Sensing Mode Only)
1-10
Auto Relock (If a door is not
opened within this amount of
time)
Off
30 sec
60 sec
5 min
1-11
Ignition / Accessory Out Upon
Unlock
Off
Ignition Pulse - same
timing as disarm pulse
Acc Pulse - same timing as disarm pulse
Ignition and Acc
Pulse - same timing as
disarm pulse
Single Pulse
Double Pulse
Off
On
1-13
Double Pulse Disarm Input
Auto Lock Mode (2 Way Inter1-14
national Remotes)
Option Group 2
Optional Setting - II
Feature
Default Setting - I
2-01
Tach Sensing Method
Optimal Tach Method
Previous Tach Method
2-02
Turbo Timer
Off
2-03
Diesel Timer
Wire
2-04
Trigger Start
Cold Start with Thermistor
Assembly
Off
2 Min
3~99sec (10sec Default)
Single Pulse
Off
On
2-06
Timer Start, or, Minimum
Interval Between Cold Starts
3 Hour (4 minute
runtime, double for
Diesel)
1.5 Hour(4 minute
runtime, double for
Diesel)
Reservation (Runtime
set by 2-7) 2 Way LCD
Remotes Only
2-07
2-08
2-09
Remote Start Runtime
Temperature of Cold Starting
Temperature of Hot Starting
15 Min
-10 C / 14 F
25 C / 77 F
25 Min
-20 C / -4 F
30 C / 86 F
45 Min
-5 C / 23 F
35 C / 95 F
2-05
Copyright 2009 Firstech, LLC.
Optional Setting - III
Low Threshold Tach
Method
1Min
Optional Setting - IV
Double Pulse
Triple Pulse
4 Min
24 Hour Repeat with
Cold Starting of 2-8
(Runtime set by 2-7) 2
Way LCD Only
3 Min
-15 C / 5 F
40 C / 104 F
Page 2
Starter System
www.firstechonline.com | www.compustar.com
STARTIT Details
2-10
Engine Sensing
Tach
Alternator
2-11
Turbo, Remote Start Runtime
Extension w/ #1 for 2 seconds
No
Yes
2-12
Crank Time
Standard
+0.2 Seconds to Crank
Time
No Connection No
Tach Sensing
(Tachless Mode Only)
No Connection 1.5
Second Crank
(Not for Manual Transmissions)
+0.6 Seconds to Crank
Time
(-)0.2 Second Crank
Time
Optional Setting - IV
Option Group 3
Feature
Default Setting - I
Optional Setting - II
Optional Setting - III
3-01
Parking lights While Remote
Started
Constant Output
Flashing Output
Off
3-02
Dome Light output
Off
Factory Rearm
45 sec
3-03
Dome Light Delay
5 sec
3-04
Starter-Kill Relay
Off
Anti-Grind + Starter
Kill
45 sec
Anti-Grind + Passive
Starter Kill
3-06
Factory Alarm Option
Off
On
3-08
Horn Output
On Double Lock Only
On Lock and Unlock
3-09
Horn Output When Alarm Is
Triggered
Pulsed Output
Constant Output (Secondary Siren)
3-10
Valet
3-11
Auxiliary Settings Mode
Auxiliary Settings With Passive Arming
3-12
Key 5 times, or Remote
Key 5 times or Remote
(I+III) while Ignition
(I+III)
is On
Disabled
Enabled
No Passive Arming
4-01
Feature
Aux 1 output
Default Setting - I
0.5sec
4-02
Aux 2 output
0.5sec
4-03
4-04
Aux 1 output Control
Aux 2 output Control
Secure Aux Output
(1 and 2 Only)
Extended Accessory After Ign
Shutoff
Key Sense or Glow Plug input
Trigger Start or Closed Loop
Alarm Trigger Input
Bypass Through RS232 Port
4-05
4-08
4-09
4-10
4-11
Copyright 2009 Firstech, LLC.
Anti-Grind
On Lock, Unlock, and
Start
Factory Rearm + 45
Sec
Auto
On Double Lock and
Start
Secure Valet (Default
code 3,3)
Passive Arming
Option Group 4
Optional Setting - II
Latch
Optional Setting - III
20 sec
Optional Setting - IV
Program
Latch
60 sec
Program
By Remote
By Remote
Arm
Arm
Disarm
Disarm
Panic
Panic
On
Off
Off
10 sec
30 sec
Until Door Open (1
min max)
Glow Plug Input
Key Sense Input
Closed Loop System
Input
Fortin
Trigger Start input
ADS
Page 3
Starter System
www.firstechonline.com | www.compustar.com
STARTIT Details
Special Option Group 1
Feature
Diesel Timer - DISL
AUX1 output time
AUX2 output time
AUX3 output time
AUX4 output time
AUX5 output time
AUX6 output time
AUX7 output time
1
2
3
4
5
6
7
8
Feature
Programmable
Output Connector
Setting Value (Seconds)
3 ~ 99
1 ~ 100
1 ~ 100
1 ~ 100
1 ~ 100
1 ~ 100
1 ~ 100
1 ~ 100
Special Option Group 2
Setting and OP500 Value
0 - Default Setting
1~19 Optional Settings
2nd Light - [1] 2nd Start - [2]
2nd IG1 - [3]
POC #1
(-) 2nd Parking Light (Green/White)
POC #2
(-) 2nd Start (Red/Black)
2nd Acc - [4] Status Out - [5] Rearm Out - [6]
POC #3
(-) 2nd Ignition (Green)
Disarm Out - [7] Horn Out - [8] Dome Light - [9]
POC #4
(-) 2nd Accessory (White/Black)
POC #5
(-) Status/GWR (Black)
POC #6
(-) Rearm Wire (Orange)
POC #7
(-) Disarm Wire (Orange/White)
POC #8
(-) Horn (White)
POC #9
(-) Dome Light (Violet)
Aux1 Out - [10] Aux2 Out - [11] Defrost - [12]
Aux4 Out - [13] Aux5 Out - [14] Aux6 Out - [15]
Aux7 Out [16] Defrost - [17] GWA - [18]
Status 2 For Manual Trans. - [19]
Option Menu Descriptions
STARTIT
Only the uncommon options are listed here
1-03 Drivers Priority Unlock - The drivers door must be isolated from the other doors. Use the Orange/Black CN4
as your 2nd Unlock output.
1-04 Double Pulse Unlock This feature cannot be used with Option 1-03. This feature provides a double pulse on
the blue unlock wire.
1-05 Rearm Output Optional settings to change the event trigger on the orange rearm wire.
Copyright 2009 Firstech, LLC.
Page 4
Starter System
STARTIT Details
www.firstechonline.com | www.compustar.com
1-06 Reservation Lock Manual transmission only. Setting III will provide a 10 second delay before the vehicle
shuts off after closing the last door to allow for another door to open. Upon a door opening, the user will have
2 minutes to close the last door in order for reservation mode to set.
1-09 Ignition Controlled Locks Setting 2 will lock the doors when the foot brake is pressed and doors closed.
Tach sensing mode must be used for setting 3. You must also turn this feature on through the remote by tap
ping I+IV (2 Way remotes) or Lock+Key (1 Way remotes)
1-10 Auto Relock This option will automatically relock/rearm after the system has been disarmed and the doors
have not been opened.
1-11 Ignition / Accessory Upon Unlock This option will pulse the ignition wire, accessory, or both upon unlock/
disarm. Most new Chrysler vehicles need the ignition and accessory pulsed to disarm the factory alarm.
1-14 Auto Lock Mode This option must be set for the Auto Mode on 2 Way international remotes to function.
2-01 Tach Sensing Method This option will adjust the method at which tach is read by the module. At default the
current setting will minimize overcrank.
2-02 Turbo Mode This option will adjust the run time after Turbo mode has been engaged.
The e-brake and door trigger input must be connected and the feature must be turned on through the remote
for this feature to work.
2-03 Diesel Timer Use this option if you cant find the glow plug wire. You can use setting 2 for a default wait to
start of 10 seconds, otherwise, you can adjust the time with your OP500 Programmer.
2-04 Trigger Start This option changes the number of times required for a negative (-) start input on Pin 12 of
CN3.
2-05 Cold Start This option turns on the cold/hot starting features. This option works in conjunction with 2-6, 2-8
and 2-9. The thermistor must be plugged into the controller/brain.
2-06 Timer Start or Interval Between Cold Start - This option dictates the time interval when the control module
will either remote start or check the temperature and remote start.
Default 1: Will start every 3 hours until the vehicle is remote started or started by key and run for 4 minutes.
Option 2: Will start every 1.5 hours until the vehicle is remote started or started by key and run for 4 minutes.
Option 3: Will start at the time specified on the 2 way remote once within 24 hours and run based on Option
2-07.
Option 4: Will start once every 24 hours if the temperature falls below Option settings 2-08 or above Option
settings 2-09.
For example, if you want your car to start and run 25 minutes when the temperature falls below 32F, you
need to set up the following options:
Copyright 2009 Firstech, LLC.
Page 5
Starter System
STARTIT Details
www.firstechonline.com | www.compustar.com
1) Option 2-05 (Cold Start) turned on,
2) Option 2-06-IV (24 hr. repeat) turned on,
3) Option 2-07-II (25 min run-time) turned on,
4) Option 2-08-IV (Temp 32F) turned on,
*Set the reservation time at 7 am (see Users guide)
**Turn on Timer Mode of the 2 way LCD remotes (see Users Guide)
2-08 Temperature of Cold Starting Works in conjunction with Options 2-05 and 2-06. See option table for avail
able temperatures.
2-10 Engine Sensing Review the Common Procedures section for complete explanations on the four engine
sensing modes.
2-11 Runtime Extension This option resets the engine run countdown before the vehicle shuts off for either the
remote start or turbo timer. To reset the runtime you must hold the remote start button for 2.5 seconds while
the unit is still running. This feature is only available on select 2 Way LCD remotes.
3-02 Dome Light Output This option sets the timing output of the Dome Light wire on CN3.
Default 1: Off
Option 2: Factory Rearm This system will pulse the dome light output during lock/arm.
Option 3: 45 second Dome Light Output activates the dome light for 45 seconds upon unlock/disarm.
Option 4: This is a combination of 2 and 3.
3-03 Dome Light Delay This option is used when connecting the door trigger input to the vehicles dome light
circuit. It delays the door trigger input to prevent the door open icon displaying on 2 Way remotes upon lock/
arm.
3-04 Starter-Kill This option determines the mode of the anti-grind/starter-kill relay.
Default 1: Anti-grind + starter-kill
Option 2: Anti-grind only (no starter-kill)
Option 3: Anti-grind + passive starter-kill: starter-kill activates in 45 seconds after ignition is turned off.
3-06 Factory Style Alarm With this option on the control module will monitor the door triggers. If the
door is opened while locked/armed then the horn will honk if connected.
3-08 Horn Output This option will change the behavior of the horn output during lock, unlock, and
remote start.
Copyright 2009 Firstech, LLC.
Page 6
Starter System
STARTIT Details
www.firstechonline.com | www.compustar.com
3-10 Valet This option changes valet modes.
Default 1: Key on/off five times or remote valet (I + III for 0.5 seconds) with key in the on position.
Option 2: Key on/off five times or remote valet (I+III for 0.5 seconds) key does not need to be in the on posi
tion.
Option 3: Secure valet: RPS Valet or remote valet (I+III for 0.5 seconds) this option prevents the system from
being put into valet via key on/off five times. To set up the RPS Valet feature, review the Placement and Use
of Components section.
3-11
Auxiliary Settings This option requires the installation of the optional Auxiliary settings module. The Auxilia
ry settings adds five additional independent auxiliary outputs for a total of seven. With this option turned on,
auxiliary 2 becomes non functional and Aux 1 becomes the data wire for the Auxiliary settings. Special Option
Group 1 allows for independent timing of these outputs.
3-12 Passive Arming w/Auxiliary Settings The ability to activate/deactivate Passive Arming through the remote
is lost once Option 3-11 is turned on. This option allows the use of Passive Arming when using the optional
Auxiliary settings.
4-01 Aux 1 Output - This option determines the duration of the Aux 1 output. Setting IV allows the output duration
to be set for a specific length of time.
4-02 Aux 2 Output - This option determines the duration of the Aux 2 output. Setting IV allows the output duration
to be set for a specific length of time.
4-05 Secure Aux Output On the default setting, button 4 on the remote must be pressed first before Aux 1 or Aux 2
can be triggered. This prevents accidental triggering of the outputs. Option setting II turns this feature off.
4-08 Extended Accessory After Ignition Shutoff This option keeps the Accessory wire powered up after the igni
tion is shut off. This can be used to keep the radio turned on even after the key is removed from the ignition
(similar to GM vehicles).
4-09
Glow Plug or Key Sense Default setting sets the wire as a glow plug input. Option setting 2 changes the wire
to a key sense input. Key sense can be used to prevent reservation mode from setting and the system from
passive arming while the key is still in the ignition. Key sense also turns off dome-light supervision when the
key is inserted into the ignition.
4-10
Trigger Start or Closed Loop System Default setting sets Pin 12 on CN3 as a trigger start input, which
will initiate remote start with a negative (-) trigger. Option 2-04 allows the number of pulses required to initiate
remote start to be changed. Setting 2 changes the wire to a closed loop input, which makes it an instant alarm
trigger when separated from ground - Ideal for protecting trailers or headlights.
4-11 Bypass Brand Through RS232 Port Default setting allows for compatibility with ADS Idatalink
modules. Setting 2 changes compatibility to Fortin bypass modules. This is only available on the
CM5000 and CM5200.
Copyright 2009 Firstech, LLC.