Operator's Manual: 5550 Watt Portable Generator
Operator's Manual: 5550 Watt Portable Generator
Operators Manual
Thank you for purchasing this quality-built Briggs & Stratton generator. We are pleased that youve placed your confidence in
the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs &
Stratton generator will provide many years of dependable service.
This manual contains safety information to make you aware of the hazards and risks associated with generator products and
how to avoid them. This generator is designed and intended only for supplying electrical power for operating compatible
electrical lighting, appliances, tools and motor loads, and is not intended for any other purpose. It is important that you read
and understand these instructions thoroughly before attempting to start or operate this equipment. Save these instructions for
future reference.
This generator requires final assembly before use. Refer to the Assembly section of this manual for instructions on final
assembly procedures. Follow the instructions completely.
Where to Find Us
You never have to look far to find Briggs & Stratton support and service for your generator. Consult your Yellow Pages. There
are over 30,000 Briggs & Stratton authorized service dealers worldwide who provide quality service. You can also contact
Briggs & Stratton Customer Service by phone at (800) 743-4115 or on the Internet at BRIGGSandSTRATTON.COM.
Generator
Model Number
Revision
Serial Number
Engine
Model Number
Type Number
Code Number
Date Purchased
BRIGGSandSTRATTON.COM
Table of Contents
Operator Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Equipment Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Unpack Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Install Wheel Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Add Engine Oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Add Fuel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
System Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Connecting to a Buildings Electrical System. . . . . . . . . . . . . . . . . . . . . . . . 9
Generator Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Starting the Engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Connecting Electrical Loads. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Stopping the Engine. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Dont Overload Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Maintenance Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Generator Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Engine Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Warranties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Emissions Control System Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Generator Owner Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Product Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Common Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Espaol
Operator Safety
Equipment Description
Read this manual carefully and become familiar
with your generator. Know its applications, its
limitations and any hazards involved.
The generator is an enginedriven, revolving field, alternating
current (AC) generator. It was designed to supply electrical
power for operating compatible electrical lighting, appliances,
tools and motor loads. The generators revolving field is
driven at about 3,600 rpm by a single-cylinder engine.
A - Explosion
B - Fire
C - Electric Shock
D - Toxic Fumes
E - Kickback
NOTICE
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected to it.
F - Hot Surface
G - Flying Objects
H - Moving Parts
J - Read Manual
Safety Rules
This is the safety alert symbol. It is used to alert
you to potential personal injury hazards. Obey all
safety messages that follow this symbol to avoid
possible injury or death.
The safety alert symbol ( ) is used with a signal word
(DANGER, WARNING, CAUTION), a pictorial and/or a safety
message to alert you to hazards. DANGER indicates a hazard
which, if not avoided, will result in death or serious injury.
WARNING indicates a hazard which, if not avoided, could
result in death or serious injury. CAUTION indicates a hazard
which, if not avoided, might result in minor or moderate
injury. NOTICE indicates a situation that could result in
equipment damage. Follow safety messages to avoid or
reduce the risk of injury or death.
The manufacturer cannot possibly anticipate every possible
circumstance that might involve a hazard. The warnings in
this manual, and the tags and decals affixed to the unit are,
therefore, not all-inclusive. If you use a procedure, work
method or operating technique that the manufacturer does
not specifically recommend, you must satisfy yourself that it
is safe for you and others. You must also make sure that the
procedure, work method or operating technique that you
choose does not render the generator unsafe.
WARNING
Running engine gives off carbon monoxide, an
odorless, colorless, poison gas.
Breathing carbon monoxide can cause headache,
fatigue, dizziness, vomiting, confusion, seizures,
nausea, fainting or death.
Operate generator ONLY outdoors.
Install a battery operated carbon monoxide alarm near the
bedrooms.
Keep exhaust gas from entering a confined area through
windows, doors, ventilation intakes, or other openings.
DO NOT start or run engine indoors or in an enclosed area,
(even if windows and doors are open), including the generator
compartment of a recreational vehicle (RV).
BRIGGSandSTRATTON.COM
WARNING
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
Generator produces hazardous voltage.
Failure to isolate generator from power utility can
result in death or injury to electric utility workers
due to backfeed of electrical energy.
When using generator for backup power, notify utility company.
Use approved transfer equipment to isolate generator from
electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
WARNING
Starter cord kickback (rapid retraction) can result
in bodily injury. Kickback will pull hand and arm
toward engine faster than you can let go.
Broken bones, fractures, bruises, or sprains
could result.
When starting engine, pull cord slowly until resistance is felt and
then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in
and turned on.
WARNING
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WHEN ADDING OR DRAINING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in
tank.
Fill or drain fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
Ensure spark plug, muffler, fuel cap, and air cleaner are in place.
DO NOT crank engine with spark plug removed.
WHEN OPERATING EQUIPMENT
DO NOT tip engine or equipment at angle which causes fuel to
spill.
This generator is not for use in mobile equipment or marine
applications.
WHEN TRANSPORTING OR REPAIRING EQUIPMENT
Transport/repair with fuel tank EMPTY or with fuel shutoff valve
OFF.
Disconnect spark plug wire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
Store away from furnaces, stoves, water heaters, clothes dryers,
or other appliances that have pilot light or other ignition source
because they can ignite fuel vapors.
WARNING
This generator does not meet U. S. Coast Guard Regulation
33CFR-183 and should not be used on marine applications.
Failure to use the appropriate U. S. Coast Guard approved
generator could result in death or serious injury and/or
property damage.
WARNING
Contact with muffler area can result in serious
burns.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 feet (1.5 m) of clearance on all sides of
generator including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
WARNING
Starter and other rotating parts can entangle
hands, hair, clothing, or accessories.
NEVER operate generator without protective housing or covers.
DO NOT wear loose clothing, jewelry or anything that may be
caught in the starter or other rotating parts.
Tie up long hair and remove jewelry.
WARNING
Unintentional sparking can result in fire or
electric shock.
CAUTION
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
DO NOT tamper with governed speed. Generator supplies
correct rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
NOTICE
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected to it.
DO NOT exceed the generators wattage/amperage capacity. See
Dont Overload Generator in the Operation section.
Start generator and let engine stabilize before connecting
electrical loads.
Connect electrical loads in OFF position, then turn ON for
operation.
Turn electrical loads OFF and disconnect from generator before
stopping generator.
NOTICE
Improper treatment of generator can damage it and
shorten its life.
Use generator only for intended uses.
If you have questions about intended use, ask dealer or contact
local service center.
Operate generator only on level surfaces.
DO NOT expose generator to excessive moisture, dust, dirt, or
corrosive vapors.
DO NOT insert any objects through cooling slots.
If connected devices overheat, turn them off and disconnect
them from generator.
Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
BRIGGSandSTRATTON.COM
Assembly
Read entire operators manual before you attempt
to assemble or operate your new generator.
Your generator requires some assembly and is ready for use
after it has been properly serviced with the recommended
fuel and oil.
If you have any problems with the assembly of your generator,
please call the generator helpline at (800) 743-4115. If calling
for assistance, please have the model, revision, and serial
number from the data tag available. See Generator Controls
and Features for data tag location.
CAUTION
E-rings can cause eye injury.
E-rings can spring back and become airborne
when installing or removing.
Always wear eye protection when installing/removing e-rings.
Unpack Generator
1. Set the carton on a rigid, flat surface.
2. Remove everything from carton except generator.
3. Open carton completely by cutting each corner from
top to bottom.
4. Leave generator on carton to install wheel kit.
The generator is supplied with:
Operators manual
Oil bottle
Wheel kit
N
L
J
F
D
E
K
G
NOTICE
Improper treatment of generator can damage it and
shorten its life.
DO NOT attempt to crank or start the engine before it has been
properly serviced with the recommended oil. This may result in
an engine failure.
Add Fuel
Fuel must meet these requirements:
Clean, fresh, unleaded gasoline.
A minimum of 87 octane/87 AKI (91 RON). High
altitude use, see High Altitude.
Gasoline with up to 10% ethanol (gasohol) or up to
15% MTBE (methyl tertiary butyl ether) is acceptable.
WARNING
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WHEN ADDING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in
tank.
Fill fuel tank outdoors.
DO NOT overfill tank. Allow space for fuel expansion.
If fuel spills, wait until it evaporates before starting engine.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
NOTICE
Avoid generator damage.
Failure to follow Operators Manual for fuel
recommendations voids warranty.
DO NOT use unapproved gasoline such as E85.
DO NOT mix oil in gasoline.
DO NOT modify engine to run on alternate fuels.
3. Install fuel cap and let any spilled fuel evaporate before
starting engine.
High Altitude
At altitudes over 5,000 feet (1524 meters), a minimum
85 octane / 85 AKI (89 RON) gasoline is acceptable. To
remain emissions compliant, high altitude adjustment is
required. Operation without this adjustment will cause
decreased performance, increased fuel consumption, and
increased emissions. See an authorized dealer for high
altitude adjustment information. Operation of the engine at
altitudes below 2,500 feet (762 meters) with the high altitude
kit is not recommended.
BRIGGSandSTRATTON.COM
System Ground
Generator Location
WARNING
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
Keep at least 5 ft. (1.5 m) clearance on all sides of generator
including overhead.
WARNING
Generator produces hazardous voltage.
Failure to isolate generator from power utility can
result in death or injury to electric utility workers
due to backfeed of electrical energy.
When using generator for backup power, notify utility company.
Use approved transfer equipment to isolate generator from
electric utility.
Use a ground fault circuit interrupter (GFCI) in any damp or
highly conductive area, such as metal decking or steel work.
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords which are worn,
frayed, bare or otherwise damaged.
DO NOT operate generator in the rain or wet weather.
DO NOT handle generator or electrical cords while standing in
water, while barefoot, or while hands or feet are wet.
DO NOT allow unqualified persons or children to operate or
service generator.
A
A
B
C
G
F
10
BRIGGSandSTRATTON.COM
WARNING
Overloaded electrical cords can overheat, arc,
and burn resulting in death, bodily injury, and/or
property damage.
NOTICE
Receptacles may be marked with rating value greater than
generator output capacity.
NEVER attempt to power a device requiring more amperage
than generator or receptacle can supply.
DO NOT overload the generator. See Dont Overload Generator.
240V
120V
120V
W (Neutral)
Y (Hot)
NEMA L14-30
X (Hot)
Ground (Green)
11
Operation
Starting the Engine
Disconnect all electrical loads from the generator. Use the
following start instructions:
1. Make sure unit is on a level surface.
IMPORTANT: Failure to start and operate the unit on a level
surface will cause the unit not to start or shut down during
operation.
2. Turn the fuel valve to the On position. The fuel valve
handle should be vertical (pointing toward the ground)
for fuel to flow.
).
WARNING
Starter cord kickback (rapid retraction) can result
in bodily injury. Kickback will pull hand and arm
toward engine faster than you can let go.
Broken bones, fractures, bruises, or sprains
could result.
When starting engine, pull cord slowly until resistance is felt and
then pull rapidly to avoid kickback.
NEVER start or stop engine with electrical devices plugged in
and turned on.
WARNING
Contact with muffler area can result in serious
burns.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
DO NOT touch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keep at least 5 feet (1.5 m) of clearance on all sides of
generator including overhead.
Code of Federal Regulation (CFR) Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
12
BRIGGSandSTRATTON.COM
NOTICE
WARNING
Backfire, fire or engine damage could occur.
DO NOT stop engine by moving choke control to Choke
position ( ).
13
Rated (Running)
Watts
1200
Additional Surge
(Starting) Watts
1800
800
500
500
75
3075 Total
Running Watts
1600
500
1800 Highest
Surge Watts
= 3075
= 1800
= 4875
Power Management
To prolong the life of your generator and attached devices, it
is important to take care when adding electrical loads to your
generator. There should be nothing connected to the
generator outlets before starting its engine. The correct and
safe way to manage generator power is to sequentially add
loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Tool or Appliance
Essentials
Light Bulb - 75 watt
Deep Freezer
Sump Pump
Refrigerator/Freezer - 18 cf
Water Well Pump - 1/3 hp
Heating/Cooling
Window AC - 10,000 BTU
Window Fan
Furnace Fan Blower - 1/2 hp
Kitchen
Microwave Oven - 1000 Watt
Coffee Maker
Electric Stove - Single Element
Hot Plate
Family Room
DVD/CD Player
VCR
Stereo Receiver
Color Television - 27 in
Personal Computer w/17 in
monitor
Other
Security System
AM/FM Clock Radio
Garage Door Opener - 1/2 hp
Electric Water Heater - 40 gallon
DIY/Job Site
Quartz Halogen Work Light
Airless Sprayer - 1/3 hp
Reciprocating Saw
Electric Drill - 1/2 hp
Circular Saw - 7-1/4 in
Miter Saw - 10 in
Table Planer - 6 in
Table Saw/Radial Arm Saw - 10 in
Air Compressor - 1-1/2 hp
75
500
800
800
1000
500
1200
1600
2000
1200
300
800
1800
600
1300
1000
1500
1500
2500
100
100
450
500
800
180
300
480
4000
520
1000
600
960
1000
1500
1800
1800
2000
2500
1200
960
1000
1500
1800
1800
2000
2500
14
BRIGGSandSTRATTON.COM
Maintenance
Maintenance Schedule
Follow the hourly or calendar intervals, whichever occurs
first. More frequent service is required when operating in
adverse conditions noted below.
First 5 Hours
Change engine oil
Every 8 Hours or Daily
Clean debris
Check engine oil level
Every 25 Hours or Yearly
Service engine air cleaner1
Every 50 Hours or Yearly
Change engine oil
Every 100 Hours or Yearly
Service spark plug
Service spark arrester
Clean cooling system1
Every 250 Hours or Yearly
Check valve clearance
1
General Recommendations
Regular maintenance will improve the performance and
extend the life of the generator. See an authorized dealer for
service.
The generators warranty does not cover items that have
been subjected to operator abuse or negligence. To receive
full value from the warranty, the operator must maintain the
generator as instructed in this manual.
Some adjustments will need to be made periodically to
properly maintain your generator.
All service and adjustments should be made at least once
each season. Follow the requirements in the Maintenance
Schedule chart above.
NOTE: Once a year you should clean or replace the spark
plug and replace the air filter. A new spark plug and clean air
filter assure proper fuel-air mixture and help your engine run
better and last longer.
Emissions Control
Maintenance, replacement, or repair of the emissions
control devices and systems may be performed by any
non-road engine repair establishment or individual.
However, to obtain no charge emissions control service,
the work must be performed by a factory authorized dealer.
See the Emissions Warranty.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive dust,
dirt, moisture, or any corrosive vapors. Cooling air slots in
the generator must not become clogged with snow, leaves,
or any other foreign material.
NOTE: DO NOT use water or other liquids to clean generator.
Liquids can enter engine fuel system, causing poor
performance and/or failure to occur. In addition, if liquid
enters generator through cooling air slots, some of the liquid
will be retained in voids and cracks of the rotor and stator
winding insulation. Liquid and dirt buildup on the generator
internal windings will eventually decrease the insulation
resistance of these windings.
Cleaning
Daily or before use, look around and underneath the
generator for signs of oil or fuel leaks. Clean accumulated
debris from inside and outside the generator. Keep the
linkage, spring and other engine controls clean. Inspect
cooling air slots and openings on generator. These openings
must be kept clean and unobstructed.
Engine parts should be kept clean to reduce the risk of
overheating and ignition of accumulated debris:
Use a damp cloth to wipe exterior surfaces clean.
NOTICE
Improper treatment of generator can damage it and
shorten its life.
DO NOT expose generator to excessive moisture, dust, dirt, or
corrosive vapors.
DO NOT insert any objects through cooling slots.
15
Engine Maintenance
WARNING
Unintentional sparking can result in fire or
electric shock.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
Disconnect the spark plug wire from the spark plug and place
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
Use approved spark plug tester.
DO NOT check for spark with spark plug removed.
Oil
Oil Recommendations
We recommend the use of Briggs & Stratton Warranty
Certified oils for best performance. Other high-quality
detergent oils are acceptable if classified for service SF, SG,
SH, SJ or higher. DO NOT use special additives.
Outdoor temperatures determine the proper oil viscosity for
the engine. Use the chart to select the best viscosity for the
outdoor temperature range expected.
CAUTION
Avoid prolonged or repeated skin contact with used motor
oil.
Used motor oil has been shown to cause skin cancer in certain
laboratory animals.
Thoroughly wash exposed areas with soap and water.
* Below 40F (4C) the use of SAE 30 will result in hard starting.
** Above 80F (27C) the use of 10W30 may cause increased oil
consumption. Check oil level more frequently.
Change the oil while the engine is still warm from running,
as follows:
1. Make sure unit is on a level surface.
2. Disconnect the spark plug wire from the spark plug and
place the wire where it cannot contact spark plug.
3. Clean area around oil drain plug (A). The oil drain plug
is located at base of engine, opposite carburetor.
16
BRIGGSandSTRATTON.COM
WARNING
Contact with muffler area can result in serious
burns.
G
F
E
A
B
17
CAUTION
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
DO NOT tamper with governed speed. Generator supplies
correct rated frequency and voltage when running at governed
speed.
DO NOT modify generator in any way.
18
BRIGGSandSTRATTON.COM
Storage
The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot be
done and you must store the unit for more than 30 days, use
the following guidelines to prepare it for storage.
Generator Storage
Clean the generator as outlined in Cleaning.
Check that cooling air slots and openings on generator
are open and unobstructed.
Long Term Storage Instructions
Fuel can become stale when stored over 30 days. Stale fuel
causes acid and gum deposits to form in the fuel system or
on essential carburetor parts. To keep fuel fresh, use Briggs
& Stratton FRESH START fuel stabilizer, available as a
liquid additive or a drip concentrate cartridge.
There is no need to drain gasoline from the engine if a fuel
stabilizer is added according to instructions. Run the engine
for 2 minutes to circulate the stabilizer throughout the fuel
system. The engine and fuel can then be stored up to
24 months.
If gasoline in the engine has not been treated with a fuel
stabilizer, it must be drained into an approved container. Run
the engine until it stops from lack of fuel. The use of a fuel
stabilizer in the storage container is recommended to
maintain freshness.
WARNING
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
Store away from furnaces, stoves, water heaters, clothes dryers
or other appliances that have pilot light or other ignition source
because they can ignite fuel vapors.
WHEN DRAINING FUEL
Turn generator OFF and let it cool at least 2 minutes before
removing fuel cap. Loosen cap slowly to relieve pressure in
tank.
Drain fuel tank outdoors.
Keep fuel away from sparks, open flames, pilot lights, heat, and
other ignition sources.
DO NOT light a cigarette or smoke.
Change Oil
While engine is still warm, drain oil from crankcase. Refill
with recommended grade. See Changing Engine Oil.
Oil Cylinder Bore
Remove spark plug and pour about 1/2 ounce (15 ml)
of clean engine oil into the cylinder.
Install spark plug and pull starter handle slowly to
distribute oil.
WARNING
Unintentional sparking can result in fire or
electric shock.
WARNING
Storage covers can be flammable.
DO NOT place a storage cover over a hot generator.
Let equipment cool for a sufficient time before placing the cover
on the equipment.
19
Troubleshooting
Problem
Cause
1.
2.
3.
4.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
Out of fuel.
20
1.
2.
3.
4.
9.
10.
11.
12.
Engine shuts down when
running.
Correction
BRIGGSandSTRATTON.COM
Warranties
Emissions Control System Warranty
Briggs & Stratton Corporation (B&S), the California Air
Resources Board (CARB) and the United States
Environmental Protection Agency (U.S. EPA)
Emissions Control System Warranty Statement (Owners
Defect Warranty Rights and Obligations)
California, United States and Canada Emissions Control
Defects Warranty Statement
The California Air Resources Board (CARB), U.S. EPA and
B&S are pleased to explain the Emissions Control System
Warranty on your small off-road engine (SORE). In
California, new small off-road engines model year 2006 and
later must be designed, built and equipped to meet the
States stringent anti-smog standards. Elsewhere in the
United States, new non-road, spark-ignition engines certified
for model year 1997 and later must meet similar standards
set forth by the U.S. EPA. B&S must warrant the emissions
control system on your engine for the periods of time listed
below, provided there has been no abuse, neglect or
improper maintenance of your small off-road engine.
Your emissions control system includes parts such as the
carburetor, air cleaner, ignition system, fuel line, muffler and
catalytic converter. Also included may be connectors and
other emissions related assemblies.
Where a warrantable condition exists, B&S will repair your
small off-road engine at no cost to you including diagnosis,
parts and labor.
Briggs & Stratton Emissions Control Defects Warranty
Coverage
Small off-road engines are warranted relative to emissions
control parts defects for a period of two years, subject to
provisions set forth below. If any covered part on your
engine is defective, the part will be repaired or replaced by
B&S.
Owners Warranty Responsibilities
As the small off-road engine owner, you are responsible for
the performance of the required maintenance listed in your
Operating and Maintenance Instructions. B&S recommends
that you retain all your receipts covering maintenance on
your small off-road engine, but B&S cannot deny warranty
solely for the lack of receipts or for your failure to ensure the
performance of all scheduled maintenance.
21
2. Length of Coverage
B&S warrants to the initial owner and each subsequent
purchaser that the Warranted Parts shall be free from
defects in materials and workmanship which caused the
failure of the Warranted Parts for a period of two years
from the date the engine is delivered to a retail
purchaser.
3. No Charge
Repair or replacement of any Warranted Part will be
performed at no charge to the owner, including
diagnostic labor which leads to the determination that a
Warranted Part is defective, if the diagnostic work is
performed at an Authorized B&S Service Dealer. For
emissions warranty service contact your nearest
Authorized B&S Service Dealer as listed in the Yellow
Pages under Engines, Gasoline, Gasoline Engines,
Lawn Mowers, or similar category.
4. Claims and Coverage Exclusions
Warranty claims shall be filed in accordance with the
provisions of the B&S Engine Warranty Policy.
Warranty coverage shall be excluded for failures of
Warranted Parts which are not original B&S parts or
because of abuse, neglect or improper maintenance as
set forth in the B&S Engine Warranty Policy. B&S is not
liable to cover failures of Warranted Parts caused by
the use of add-on, non-original, or modified parts.
5. Maintenance
Any Warranted Part which is not scheduled for
replacement as required maintenance or which is
scheduled only for regular inspection to the effect of
repair or replace as necessary shall be warranted as
to defects for the warranty period. Any Warranted Part
which is scheduled for replacement as required
maintenance shall be warranted as to defects only for
the period of time up to the first scheduled replacement
for that part. Any replacement part that is equivalent in
performance and durability may be used in the
performance of any maintenance or repairs. The owner
is responsible for the performance of all required
maintenance, as defined in the B&S Operators Manual.
6. Consequential Coverage
Coverage hereunder shall extend to the failure of any
engine components caused by the failure of any
Warranted Part still under warranty.
22
Emission Information
Engines that are certified to meet the California Air
Resources Board (CARB) Tier 2 Emission Standards must
display information regarding the Emissions Durability
Period and Air Index. The engine manufacturer makes this
information available to the consumer on emission labels.
The engine emission label will indicate certification
information.
The Emissions Durability Period describes the number of
hours of actual running time for which the engine is certified
to be emissions compliant, assuming proper maintenance in
accordance with the Operating & Maintenance Instructions.
The following categories are used:
Moderate: Engine is certified to be emission compliant for
125 hours of actual engine running time.
Intermediate: Engine is certified to be emission compliant
for 250 hours of actual engine running time.
Extended: Engine is certified to be emission compliant for
500 hours of actual engine running time.
For example, a typical walk-behind lawn mower is used 20 to
25 hours per year. Therefore, the Emissions Durability
Period of an engine with an intermediate rating would
equate to 10 to 12 years.
Certain engines will be certified to meet the United States
Environmental Protection Agency (USEPA) Phase 2 emission
standards. For phase 2 certified engines, the Emissions
Compliance Period referred to on the Emissions Compliance
label indicates the number of operating hours for which the
engine has been shown to meet Federal emission
requirements.
For engines less than 225 cc displacement:
Category C = 125 hours
Category B = 250 hours
Category A = 500 hours.
For engines of 225 cc or more displacement:
Category C = 250 hours
Category B = 500 hours
Category A = 1000 hours.
BRIGGSandSTRATTON.COM
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY
Effective February 1, 2006 replaces all undated Warranties and all Warranties dated before February 1, 2006
LIMITED WARRANTY
Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or
workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This
warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest Authorized Service Dealer in
our dealer locator map at BRIGGSandSTRATTON.COM.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW. ANY AND ALL IMPLIED WARRANTIES ARE
EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some
states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and
you may also have other rights which vary from state to state or country to country.
WARRANTY PERIOD
Consumer Use
2 years*
Commercial Use
1 year
*Second year parts only
The warranty period begins on the date of purchase by the first retail end user, and continues for the period of time stated above. Consumer Use" means
personal residential household use by a retail consumer. Commercial Use" means all other uses, including use for commercial, income producing or rental
purposes. Once equipment has experienced commercial use, it shall thereafter be considered as commercial use for purposes of this warranty.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF OF PURCHASE
RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED, THE MANUFACTURING
DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.
Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not cover
repair when normal use has exhausted the life of a part or the equipment.
Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or
alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as, in our judgment,
to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as air filters, adjustments, fuel system
cleaning and obstruction (due to chemical, dirt, carbon, lime, and so forth).
Other Exclusions: This warranty excludes wear items such as o-rings, filters, etc., or malfunctions resulting from accidents, abuse, modifications,
alterations, or improper servicing or freezing or chemical deterioration. Accessory parts such as starting batteries, generator adapter cord sets and
storage covers are excluded from the product warranty. This warranty excludes used, reconditioned, and demonstration equipment, equipment used
for prime power in place of utility power, equipment used in life support applications, and failures due to acts of God and other force majeure events
beyond the manufacturers control. 198189E, Rev. B, 12/31/2006
23
Portable Generator
Product Specifications
Starting Wattage . . . . . . . . . . . . . . . . . . . . . . . .8,550 watts
Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5,550 watts
AC Load Current:
at 120 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . .46.2 Amps
at 240 Volts . . . . . . . . . . . . . . . . . . . . . . . . . . .23.1 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Single phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . . . .60 Hertz
Shipping Weight . . . . . . . . . . . . . . . . . . . . . .150 lb (68 kg)
Displacement . . . . . . . . . . . . . . . . . . . . . . 18.61 ci (305 cc)
Spark Plug Gap . . . . . . . . . . . . . . . . . . 0.030 in (0.76 mm)
Fuel Capacity . . . . . . . . . . . . . . . . . 7 U.S. gallons (26.5 L)
Oil Capacity . . . . . . . . . . . . . . . . . .28 Ounces (0.83 Liters)
Power Ratings: The gross power rating for individual gas engine models is labeled in accordance with SAE (Society of
Automotive Engineers) code J1940 (Small Engine Power & Torque Rating Procedure), and rating performance has been
obtained and corrected in accordance with SAE J1995 (Revision 2002-05). Torque values are derived at 3060 RPM; horsepower
values are derived at 3600 RPM. Actual gross engine power will be lower and is affected by, among other things, ambient
operating conditions and engine-to-engine variability. Given both the wide array of products on which engines are placed and
the variety of environmental issues applicable to operating the equipment, the gas engine will not develop the rated gross power
when used in a given piece of power equipment (actual "on-site" or net power). This difference is due to a variety of factors
including, but not limited to, accessories (air cleaner, exhaust, charging, cooling, carburetor, fuel pump, etc.), application
limitations, ambient operating conditions (temperature, humidity, altitude), and engine-to-engine variability. Due to
manufacturing and capacity limitations, Briggs & Stratton may substitute an engine of higher rated power for this Series engine.
Briggs & Stratton Power Products Group, LLC
900 N. Parkway
Jefferson, Wisconsin, 53549 U.S.A.
24
(800) 743-4115
BRIGGSandSTRATTON.COM
Muchas gracias por comprar este generador Briggs & Stratton de gran calidad. Nos alegra que haya depositado su confianza
en la marca Briggs & Stratton. Siempre que sea utilizado de acuerdo con las instrucciones de este manual, su generador
Briggs & Stratton le proporcionar muchos aos de buen funcionamiento.
Este manual contiene informacin sobre seguridad para hacerle consciente de los riesgos asociados a los generadores y
mostrarle cmo evitarlos. Este generador se ha diseado exclusivamente para suministrar energa elctrica a cargas
compatibles de iluminacin, electrodomsticos, herramientas y motores. No debe utilizarse para ningn otro fin. Es
importante leer detenidamente y comprender estas instrucciones antes de poner en marcha o utilizar el equipo. Conserve este
manual para futuras consultas.
Este generador requiere montaje final antes de ser usado. Consulte la seccin Montaje de este manual, donde encontrar
instrucciones para el montaje final. Siga las instrucciones al pie de la letra.
Dnde encontrarnos
Usted no tendr que ir muy lejos para encontrar el servicio tcnico de Briggs & Stratton para su generador. Consulte las
Pginas Amarillas. Hay ms de 30.000 proveedores de Briggs & Stratton autorizados en todo el mundo, proporcionando un
servicio de calidad. Tambin puede ponerse en contacto con Atencin al Cliente de Briggs & Stratton llamando al
(800) 743-4115 o por Internet en BRIGGSandSTRATTON.COM.
Generador
Nmero de Modelo
Revisin
Nmero de Serie
Motor
Nmero de Modelo
Nmero de Tipo
Nmero de Cdigo
Fecha de compra
BRIGGSandSTRATTON.COM
Tabla de Contenido
Seguridad de operario . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Descripcin del equipo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Reglas de seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Montaje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Desembalaje del generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Instale el juego de ruedas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Agregar aceite al motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Agregue combustible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Tierra del sistema . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Conexin al sistema elctrico de un edificio . . . . . . . . . . . . . . . . . . . . . . . . 9
Ubicacin del generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Controles y caractersticas. . . . . . . . . . . . . . . . . . . . . . . . . 10
Juegos de cordones y enchufes conectores . . . . . . . . . . . . . . . . . . . . . . . 11
Operando . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Encienda el motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Conexin de cargas elctricas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Parada del motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
No sobrecargar el generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Mantenimiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Plan de mantenimiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Mantenimiento del generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Mantenimiento del motor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Almacenamiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Resolucin de problemas . . . . . . . . . . . . . . . . . . . . . . . . . 20
Garantas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Garanta del sistema de control de emisiones . . . . . . . . . . . . . . . . . . . . . . 21
Garanta para el propietario de una generador. . . . . . . . . . . . . . . . . . . . . . 23
Especificaciones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Especificaciones del producto . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Servicio comn despide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Espaol
Seguridad de operario
AVISO
A - Explosin
B - Fuego
C - Descarga Elctrica
D - Gases Txicos
E - Retroceso
F - Superficie Caliente
G - Objets volant
H - Partes en Movimiento
J - Manual del Operario
Reglas de seguridad
ste es el smbolo de alerta de seguridad. Sirve
para advertir al usuario de un posible riesgo para
su integridad fsica. Siga todos los mensajes de
seguridad que figuren despus de este smbolo
para evitar lesiones o incluso la muerte.
El smbolo de alerta de seguridad ( ) se utiliza con una
palabra de sealizacin (PELIGRO, PRECAUCIN,
ADVERTENCIA), una imagen y/o un mensaje de seguridad para
advertir al usuario de un riesgo. PELIGRO indica un riesgo que,
de no evitarse, provocar la muerte o lesiones de gravedad.
ADVERTENCIA indica un riesgo que, de no evitarse, puede
provocar la muerte o lesiones de gravedad. PRECAUCIN
indica un riesgo que, de no evitarse, puede provocar lesiones
moderadas. Cuando se utiliza sin el smbolo de alerta, AVISO
indica una situacin que podra producir daos en el equipo.
Siga en todo momento los mensajes de seguridad para evitar o
reducir el riesgo de lesiones y de muerte.
El fabricante no puede anticipar todas las posibles
circunstancias que podran conllevar peligro. Por lo tanto, las
advertencias de este manual, as como las etiquetas y placas
de la unidad, no incluyen todo. Si usa un procedimiento,
mtodo de trabajo o tcnica operativa que no est
especficamente recomendada por el fabricante, debe
asegurarse de que no entraa peligro para usted ni para
otras personas. Tambin debe asegurarse de que el
procedimiento, mtodo de trabajo o tcnica operativa elegida
no hace que el generador deje de ser seguro.
ADVERTENCIA
Al motor funcionar, se produce monxido de
carbono, un gas inodoro y venenoso.
Respirar monxido de carbono puede provocar
dolor de cabeza, fatiga, mareos, vmitos,
confusin, ataques, nuseas, desmayos o incluso
la muerte.
Opere el generador SOLAMENTE al aire libre.
Instale una alarma de monxido de carbono con batera cerca
de los dormitorios.
Asegrese de que los gases de escape no puedan entrar por
ventanas, puertas, tomas de aire de ventilacin u otras aberturas
en un espacio cerrado en el que puedan acumularse.
NO arranque ni deje funcionar el motor en interiores ni en zonas
cerradas, (aunque haya ventanas y puertas abiertas), incluyendo
el compartimiento del generador en un vehculo recreativo o RV.
BRIGGSandSTRATTON.COM
ADVERTENCIA
ADVERTENCIA
ADVERTENCIA
El retroceso (repliegue rpido) del cable del
arrancador puede producir lesiones. El retroceso
impedir que el usuario suelte el cable a tiempo y
tirar de su mano y brazo hacia el motor.
Como resultado, podran producirse fracturas,
contusiones o esguinces.
Cuando arranque el motor, tire lentamente del cable hasta sentir
una resistencia y, a continuacin, tire rpidamente de l para
evitar su retroceso.
NUNCA arranque o pare el motor cuando haya aparatos
elctricos conectados y en funcionamiento.
ADVERTENCIA
Los generadores producen un voltaje muy
poderoso.
Si no asla el generador de utilidades de energa,
puede hacer que los trabajadores de electricidad
sufran heridas graves e inclusive la muerte,
debido a la retroalimentacin de la energa
elctrica.
Cuando use un generador como poder de energa auxiliar,
notifique a la compaa de utilidades. Use el equipo de
transferencia aprobado para aislar el generador de otra utilidad
elctrica.
Use un interruptor para la falla del circuito de tierra (GFCI) en
cualquier rea bastante hmeda o que sea altamente conductiva,
tales como terrazas de metal o trabajo hecho con acero.
NO toque los alambres pelados o receptculos.
NO use un generador con cables elctricos que estn
malgastados, rotos, pelados o daados de cualquier forma.
NO opere el generador bajo la lluvia.
NO maneje el generador o cables elctricos mientras est
parado en agua, descalzo o cuando las manos y los pies estn
mojados.
NO permita que personas descalificadas o nios operen o sirvan
al generador.
ADVERTENCIA
Este generador no cumple la norma 33CFR-183 del cuerpo de
guardacostas de EE.UU. y no debe utilizarse en aplicaciones
marinas.
El uso de un generador no homologado por cuerpo de
guardacostas de EE.UU. puede provocar lesiones y daos
materiales.
Espaol
ADVERTENCIA
ADVERTENCIA
El arrancador y otras piezas que rotan pueden
enredar las manos, el pelo, la ropa, o los
accesorios.
NUNCA utilice la generador sin sus carcasas o tapas de
proteccin.
NO use ropa suelta, joyas o elementos que puedan quedar
atrapados en el arranque o en otras partes rotatorias.
Ate para arriba el pelo largo y quite la joyera.
ADVERTENCIA
Chispear involuntario puede tener como
resultado el fuego o el golpe elctrico.
PRECAUCIN
AVISO
El sobrepasar la capacidad del amperaje y vataje del
generador, puede daar al generador y los aparatos
elctricos conectados al mismo.
Vea No sobrecargue generador.
Encienda su generador y deje que el motor se estabilice antes
de conectar las cargas elctricas.
Conecte las cargas elctricas en la posicin de apagado (OFF),
luego encienda (ON) para su operacin.
Apague (OFF) las cargas elctricas y desconctelas del
generador antes de parar el generador.
AVISO
El tratamiento inadecuado del generador puede daarlo y
acortar su vida productiva.
Use el generador solamente con la finalidad para el cual fue
diseado.
En caso de dudas sobre su uso, dirjase al distribuidor.
Opere el generador solamente en superficies niveladas.
NO exponga al generador a una humedad excesiva, polvo,
suciedad o vapores corrosivos.
NO inserte cualquier objeto a travs de las ranuras de
enfriamiento.
Si los aparatos conectados se sobrecalientan, apguelos y
desconctelos del generador.
Apague el generador si:
-Se pierde la salida elctrica;
-El equipo produce chispas, humo o emite llamas;
-La unidad vibra de una manera excesiva.
BRIGGSandSTRATTON.COM
Montaje
PRECAUCIN
Las anillas en e pueden provocar lesiones oculares.
N
L
J
F
D
E
K
G
Espaol
AVISO
El tratamiento inadecuado del generador puede daarlo y
acortar su vida productiva.
NO procure acodar ni empezar el motor antes ha sido atendido a
apropiadamente con el aceite recomendado. Esto puede tener
como resultado una avera del motor.
Agregue combustible
El combustible debe reunir los siguientes requisitos:
Gasolina sin plomo limpia y nueva.
Un mnimo de 87 octanos/87 AKI (91 RON). Para uso a
gran altitud, consulte Gran altitud.
El motor admite gasolina con hasta un 10% de etanol
(gasohol) o hasta un 15% de MTBE (ter metil
terbutlico).
ADVERTENCIA
La combustible y sus vapores son
extremadamente inflamables y explosivos.
El fuego o una explosin pueden causar
quemaduras severas e inclusive la muerte.
CUANDO ANADA COMBUSTIBLE
Apague el generador (posicin OFF) y djelo enfriar al menos
por 2 minutos antes de remover la tapa de la combustible.
Afloje la tapa lentamente para dejar que la presin salga del
tanque.
Llene o vace el depsito de combustible a la intemperie.
NO llene demasiado el tanque. Permita al menos espacio para la
expansin del combustible.
Si se ha derramado combustible, espere a que se evapore antes
de arrancar el motor.
Mantenga la combustible alejada de chispas, llamas abiertas,
pilotos, calor y otras fuentes de ignicin.
NO encienda un cigarrillo o fume.
AVISO
Evite el dao del generador.
El fracaso para seguir Manual de Operario para el
combustible reccomendations garanta de vacos.
NO utilice gasolina no autorizada; por ejemplo, E85.
NO mezcle aceite con gasolina.
NO modifique el motor para hacerlo funcionar con otros
combustibles.
BRIGGSandSTRATTON.COM
ADVERTENCIA
Los gases y el calor de escape pueden inflamar
los materiales combustibles y las estructuras o
daar el depsito de combustible y provocar un
incendio.
Requisitos especiales
Es posible que haya normas u ordenanzas locales y
nacionales en materia de seguridad e higiene en el trabajo
aplicables al uso del generador. Consulte con un electricista
cualificado, un inspector elctrico o el organismo
competente.
En algunas zonas, es obligatorio registrar los
generadores en las compaas elctricas locales.
Si el generador se utiliza en una obra, puede ser
necesario cumplir normas y requisitos adicionales.
ADVERTENCIA
Los generadores producen un voltaje muy
poderoso.
Si no asla el generador de utilidades de energa,
puede hacer que los trabajadores de electricidad
sufran heridas graves e inclusive la muerte,
debido a la retroalimentacin de la energa
elctrica.
Cuando use un generador como poder de energa auxiliar,
notifique a la compaa de utilidades. Use el equipo de
transferencia aprobado para aislar el generador de otra utilidad
elctrica.
Use un interruptor para la falla del circuito de tierra (GFCI) en
cualquier rea bastante hmeda o que sea altamente conductiva,
tales como terrazas de metal o trabajo hecho con acero.
NO toque los alambres pelados o receptculos.
NO use un generador con cables elctricos que estn
malgastados, rotos, pelados o daados de cualquier forma.
NO opere el generador bajo la lluvia.
NO maneje el generador o cables elctricos mientras est
parado en agua, descalzo o cuando las manos y los pies estn
mojados.
NO permita que personas descalificadas o nios operen o sirvan
al generador.
Espaol
Controles y caractersticas
Lea este Manual del Operario y reglas de seguridad antes de poner en marcha su generador.
Compare las ilustraciones con su generador, para familiarizarse con la ubicacin de los diversos controles y ajustes.
Guarde este manual para futuras consultas.
K
A
B
C
G
F
10
BRIGGSandSTRATTON.COM
ADVERTENCIA
Los cables elctricos sobrecargados pueden
recalentarse, formar un arco o quemarse,
provocando la muerte, lesiones y/o daos
materiales.
AVISO
Las tomas elctricas pueden marcar un valor nominal
mayor que la capacidad de salida del generador.
NUNCA intente conectar un dispositivo que requiera ms
amperaje del que el generador o la toma elctrica pueden
suministrar.
NO sobrecargar el generador. Vase No sobrecargar el
generador.
240V
120V
120V
W (Neutro)
Y (Cargado)
NEMA L14-30
X (Cargado)
Tierra (Verde)
Espaol
11
Operando
Encienda el motor
Desconecte todas las cargas elctricas del generador. Use
las siguientes instrucciones para encender:
1. Asegrese de que la unidad est en una superficie
plana.
IMPORTANTE: Si la unidad no se arranca y utiliza en una
superficie plana, se pueden producir problemas de arranque
y de parada durante el funcionamiento.
2. Gire la vlvula del combustible a la posicin "On". El
asidero de la vlvula del combustible debe ser vertical
(sealar hacia el suelo) para el combustible para fluir.
ADVERTENCIA
El contacto con la zona del silenciador puede
producir quemaduras graves.
Los gases y el calor de escape pueden inflamar
los materiales combustibles y las estructuras o
daar el depsito de combustible y provocar un
incendio.
ADVERTENCIA
El retroceso (repliegue rpido) del cable del
arrancador puede producir lesiones. El retroceso
impedir que el usuario suelte el cable a tiempo y
tirar de su mano y brazo hacia el motor.
Como resultado, podran producirse fracturas,
contusiones o esguinces.
Cuando arranque el motor, tire lentamente del cable hasta sentir
una resistencia y, a continuacin, tire rpidamente de l para
evitar su retroceso.
NUNCA arranque o pare el motor cuando haya aparatos
elctricos conectados y en funcionamiento.
12
BRIGGSandSTRATTON.COM
NOTA:
NO conectar cargas de 240 V en las tomas elctricas
dobles.
NO conectar cargas trifsicas al generador.
NO conectar cargas de 50 Hz al generador.
NO SOBRECARGAR EL GENERADOR. Vase No
sobrecargar el generador.
AVISO
El sobrepasar la capacidad del amperaje y vataje del
generador, puede daar al generador y los aparatos
elctricos conectados al mismo.
ADVERTENCIA
El motor podra petardear, incendiarse o daarse.
NO coloque la palanca estranguladora en la posicin "Choke"
( ) para parar el motor.
Espaol
13
No sobrecargar el generador
Capacidad
Debe asegurarse de que su generador puede proveer los
suficientes vatios de potencia continua (vatiaje nominal) y
vatios de salida para los elementos que desee alimentar al
mismo tiempo. Siga estos sencillos pasos:
1. Seleccione los elementos que quiere alimentar al
mismo tiempo.
2. Sume la potencia nominal de esos elementos. Esa es la
cantidad de energa que su generador debe producir
para mantener sus elementos en funcionamiento. Vea
Gua de Referencia de Potencia.
3. Calcule cuntos vatios de salida necesitar. La potencia
de salida se refiere al corto arranque de energa que se
necesita para arrancar herramientas o dispositivos a
motor, como una radial o un refrigerador. Como no
todos los motores arrancan al mismo tiempo, el total de
vatios de salida puede calcularse aadiendo slo el
elemento con la potencia de salida ms alta al total de
vatios de potencia continua que obtuvimos en el paso 2.
Vatios de potencia*
continua
Vatios de potencia
de salida adicional
Bsicos
Bombilla de 75 vatios
75
Congelador industrial
500
500
800
1200
800
1600
1000
2000
1200
1800
Ventilador de ventana
300
600
800
1300
1000
Cafetera
1500
1800
1500
1600
Plancha de cocina
2500
Cocina
Ejemplo:
Herramienta o Aparato Elctrico
1200
Refrigerador
800
Congelador industrial
500
500
Habitacin familiar
Televisin
500
Reproductor de DVD/CD
100
75
VCR
100
1800 (Vatios de
Carga ms alto)
Receptor estreo
450
500
= 3075
= 1800
= 4875
800
Sistema de seguridad
180
Radio-reloj AM/FM
300
480
520
4000
Control de la energa
Para prolongar la vida de su generador y los aparatos que
conecte a l, es muy importante tener cuidado cuando se le
aaden cargas elctricas. No deber haber nada conectado a
las tomas del generador antes de encender el motor. El
modo seguro y correcto de gestionar la energa del
generador es aadir las cargas secuencialmente, como se
indica a continuacin:
1. Sin tener nada conectado al generador, encienda el
motor tal como se describe en este manual.
2. Conecte y encienda la primera carga, preferiblemente la
mayor que usted tenga.
3. Permita que la salida del generador se estabilice (el
motor funciona suavemente y el aparato funciona
adecuadamente).
4. Conecte y encienda la prxima carga.
5. De nuevo, permita que el generador se estabilice.
14
Otros
Taller
Luz halgena de cuarzo para trabajar
1000
600
1200
Sierra sable
960
960
1000
1000
1500
1500
1800
1800
1800
1800
2000
2000
2500
2500
BRIGGSandSTRATTON.COM
Mantenimiento
Plan de mantenimiento
Siga los intervalos de horas o de calendario, los que sucedan
antes. Si opera en condiciones adversas (sealadas ms
abajo) es necesario un mantenimiento ms frecuente.
Primeras Cinco (5) Horas
Cambie el aceite del motor
Control de emisiones
Cualquier establecimiento o individuo especializado en la
reparacin de motores que no sean de automocin puede
encargarse del mantenimiento, la sustitucin y la
reparacin de los dispositivos y sistemas de control de
emisiones.No obstante, para realizar la revisin gratuita de
control de emisiones, deber acudir a un distribuidor
autorizado por el fabricante. Vase Garanta de emisiones.
Recomendaciones Generales
El mantenimiento peridico mejorar el rendimiento y
prolongar la vida til del generador. Acuda a un distribuidor
autorizado para reparar la unidad.
La garanta del generador no cubre los elementos que hayan
sido sujetos al abuso o negligencia del operador. Para recibir
el valor completo de la garanta, el operador deber
mantener el generador de la forma descrita en este manual.
Se debern llevar a cabo algunos ajustes peridicamente
para mantener correctamente su generador.
Todos los ajustes de la seccin Servicio y Ajustes de este
manual debern ser hechos por lo menos una vez en cada
estacin. Cumpla con los requisitos de la tabla Plan de
Mantenimiento descrita anteriormente.
NOTA: Una vez al ao deber limpiar o reemplazar la buja y
reemplazar el filtro de aire. Una buja nueva y un filtro de aire
limpio garantizan una mezcla de combustible-aire adecuada y
ayuda a que su motor funcione mejor y tenga una vida til
ms prolongada.
Limpieza
Limpie a diario, o antes de cada uso, los residuos
acumulados en el generador. Mantenga limpias las
conexiones, los muelles y los mandos. Limpie todo resto de
combustible de la zona que rodea al silenciador y de detrs
del mismo. Inspeccione las ranuras para aire de enfriamiento
y la apertura del generador. Estas aperturas debern
mantenerse limpias y despejadas.
Mantenga limpios los componentes del generador para
reducir el riesgo de sobrecalentamiento e ignicin de los
residuos acumulados.
Utilice un trapo hmedo para limpiar las superficies
exteriores.
AVISO
El tratamiento inadecuado del generador puede daarlo y
acortar su vida productiva.
NO exponga al generador a una humedad excesiva, polvo,
suciedad o vapores corrosivos.
NO inserte cualquier objeto a travs de las ranuras de enfriamiento.
Espaol
15
ADVERTENCIA
Chispear involuntario puede tener como
resultado el fuego o el golpe elctrico.
Aceite
Recomendaciones sobre el aceite
Para obtener el mejor rendimiento, recomendamos utilizar
aceites certificados con garanta Briggs & Stratton. Tambin
se pueden utilizar otros aceites detergentes de alta calidad
con clasificacin de servicio SF, SG, SH, SJ o superior. NO
utilice aditivos especiales.
Las temperaturas exteriores determinan la viscosidad
adecuada del aceite para el motor. Utilice el cuadro para
seleccionar la mejor viscosidad para el intervalo de
temperatura exterior previsto.
AVISO
Evite el contacto prolongado o repetido de piel con aceite
usado de motor.
El aceite usado del motor ha sido mostrado al cancer de la piel
de la causa en ciertos animales del laboratorio.
Completamente lavado expuso reas con el jabn y el agua.
16
BRIGGSandSTRATTON.COM
F
E
Espaol
17
ADVERTENCIA
El contacto con la zona del silenciador puede
producir quemaduras graves.
Los gases y el calor de escape pueden inflamar
los materiales combustibles y las estructuras o
daar el depsito de combustible y provocar un
incendio.
NO toque las superficies calientes y EVITE los gases del escape
a alta temperatura.
Permita que el equipo se enfre antes de tocarlo.
Deje un espacio mnimo de 1.5 m (5 pies) alrededor del
generador, incluida la parte superior.
El Cdigo de Normativa Federal (CFR, Ttulo 36: Parques,
Bosques y Propiedad Pblica) obliga a instalar una pantalla
apagachispas en los equipos con motor de combustin interno
y a mantenerla en buenas condiciones de funcionamiento,
conforme a la norma 5100-1C (o posterior) del Servicio Forestal
de la USDA. En el Estado de California, la ley exige el uso de una
pantalla apagachispas (Seccin 4442 del Cdigo de Recursos
Pblicos de California). En otros estados puede haber leyes
similares en vigor.
A
B
18
PRECAUCIN
Las velocidades de operacin en exceso, aumentan los
riesgos de heridas y daos al generador.
Las velocidades bajan en exceso, imponen una carga muy
pesada.
NO cambie ninguna velocidad determinada. El generador
suministra una frecuencia y un voltaje calificado cuando
funciona a una velocidad determinada.
NO modifique al generador en ninguna forma.
BRIGGSandSTRATTON.COM
Almacenamiento
Cambio de aceite
Con el motor todava caliente, drene el aceite de la caja del
cigeal. Vuelva a llenarlo con el grado de aceite
recomendado.
ADVERTENCIA
La combustible y sus vapores son
extremadamente inflamables y explosivos.
ADVERTENCIA
Chispear involuntario puede tener como
resultado el fuego o el golpe elctrico.
ADVERTENCIA
Las cubiertas para almacenamiento pueden ser
inflamables.
NO coloque una cubierta encima de un generador caliente.
Deje que la unidad se enfre lo suficientemente antes de que le
coloque la cubierta.
19
Resolucin de problemas
Problemo
Causa
1. El interruptor automtico de circuito
est abierto.
2. Conexin mal o defectuosa del juego
de cables.
3. El dispositivo conectado est daado.
4. Avera en el generador.
El motor no se enciende; o se
enciende y funciona mal.
Sin gasolina.
1. La carga es muy alta.
2. Filtro de aire sucio.
20
Accion
1. Reposicione el interruptor.
2. Revise y repare.
3. Conecte otro dispositivo que est buenas
condiciones.
4. Contacte el distribuidor de servicio
autorizado.
1. Desconecte la carga elctrica en corto.
2. Vea No Sobrerecarque Generador.
3. Contacte el distribuidor de servicio
autorizado.
4. Contacte el distribuidor de servicio
autorizado.
1. Gire la vlvula del combustible a la
posicin "On".
2. Coloque del interruptor balancn en "On".
3. Limpie o reemplace el depurador de aire.
4. Llnelo con combustible fresco.
5. Drene el tanque de gasolina; llnelo con
combustible fresco.
6. Conecte el cable a la buja.
7. Reemplace la buja.
8. Drene el tanque de gasolina; llnelo con
combustible fresco.
9. Abra por completo el cebador y haga girar
el motor.
10. Contacte el distribuidor de servicio
autorizado.
11. Contacte el distribuidor de servicio
autorizado.
12. Contacte el distribuidor de servicio
autorizado.
Llene el tanque de combustible.
1. Vea No Sobrerecarque Generador.
2. Reemplace el filtro de aire.
Contacte el distribuidor de servicio autorizado.
BRIGGSandSTRATTON.COM
Garantas
Garanta del sistema de control de emisiones
Briggs & Stratton Corporation (B&S), el California Air
Resources Board (CARB, Consejo de recursos de aire de
California) y la United States Environmental Protection
Agency (U.S. EPA, Agencia estadounidense de proteccin
del medioambiente)
Declaracin de garanta del sistema de control de
emisiones (derechos y obligaciones del propietario para la
garanta contra defectos)
Garanta contra defectos del sistema de control de
emisiones de California, Estados Unidos y Canad
California Air Resources Board (CARB), U.S. EPA y B&S le
explican a continuacin la garanta del sistema de control de
emisiones de su pequeo motor para mquinas de servicio
(SORE, Small Offroad Engine). En California, los modelos de
pequeos motores para mquinas de servicio a partir del ao
2006 deben estar diseados, fabricados y equipados
conforme a los exigentes estndares de lucha contra la
contaminacin del Estado. En otros lugares de Estados
Unidos, los modelos de motores para mquinas de servicio
con encendido por buja a partir del ao 1997 deben cumplir
normas similares determinadas por la U.S. EPA. B&S debe
garantizar el sistema de control de emisiones de su motor
durante los perodos que se indican a continuacin, siempre
que no se haya hecho un uso indebido o negligente ni un
mantenimiento inadecuado del pequeo motor para
mquinas de servicio.
El sistema de control de emisiones incluye las siguiente
piezas carburador, filtro de aire, sistema de encendido,
conducto de combustible, silenciador y convertidor
cataltico. Tambin puede incluir conectores y otros
conjuntos relacionados con las emisiones.
Si se cumplen las condiciones de la garanta, B&S reparar
el motor sin coste alguno, incluido el diagnstica, las piezas
y la mano de obra.
Cobertura de la garanta contra defectos del sistema de
control de emisiones de Briggs & Stratton
Los pequeos motores para mquinas de servicio estn
garantizados contra defectos de las piezas de control de
emisiones durante un perodo de dos aos, conforme a las
siguientes disposiciones. Si cualquier pieza del motor con
cobertura es defectuosa, ser reparada o sustituida por B&S.
Responsabilidades de la garanta del propietario
Como propietario del pequeo motor para mquinas de
servicio, usted es responsable de la correcta realizacin de las
operaciones de mantenimiento que se enumeran en las
Instrucciones de uso y mantenimiento. B&S recomienda
conservar todas las facturas relativas al mantenimiento del
motor, pero B&S no puede denegar la garanta basndose
nicamente en la falta de facturas o en la imposibilidad por
parte del propietario de asegurar la correcta realizacin de
todas las operaciones de mantenimiento.
Espaol
21
2.
3.
4.
5.
6.
22
BRIGGSandSTRATTON.COM
GARANTA LIMITADA
Briggs & Stratton Power Products Group, LLC reparar o sustituir sin cargo alguno cualquier componente del generador porttil que presente defectos
de materiales y/o mano de obra. Los gastos de transporte de las producto enviadas para reparar o sustituir conforme a los trminos de esta garanta
corrern a cargo del comprador. El periodo de vigencia y las condiciones de esta garanta son los que se estipulan a continuacin. Para obtener servicio
en garanta, localice el distribuidor de servicio autorizado ms prximo en nuestro mapa de distribuidores, en www.BRIGGSandSTRATTON.COM.
NO EXISTE NINGUNA OTRA GARANTA EXPLCITA. LAS GARANTAS IMPLCITAS, INCLUIDAS LAS DE COMERCIABILIDAD O IDONEIDAD PARA UN
FIN CONCRETO, SE LIMITAN A UN AO DESDE LA FECHA DE COMPRA O AL LMITE DE TIEMPO PERMITIDO POR LA LEY. QUEDAN EXCLUIDAS
TODAS LAS GARANTAS IMPLCITAS QUEDA EXCLUIDA LA RESPONSABILIDAD POR DAOS SECUNDARIOS Y DERIVADOS HASTA EL LMITE
PERMITIDO POR LA LEY. Algunos pases o estados no permiten limitar la duracin de una garanta implcita ni excluir o limitar los daos secundarios y
derivados. Por tanto, es posible que las limitaciones y exclusiones mencionadas no sean aplicables en su caso. Esta garanta le otorga determinados
derechos legales y es posible que tenga otros derechos que pueden variar de un pas o estado a otro.
PERODO DE GARANTA
Uso del consumidor
2 aos
Uso comercial
1 ao
* Segundo ao despide slo
El perodo de garanta comienza en la fecha de compra del primer usuario final y se prolonga durante el tiempo especificado. "Uso del consumidor" significa
uso domstico personal por parte de un consumidor final. "Uso comercial" significa cualquier otro uso, incluidos los usos con fines comerciales, de
generacin de ingresos o alquiler. Una vez que el equipo se haya usado con fines comerciales, se considerar como equipo de uso comercial a efectos de
esta garanta.
NO ES NECESARIO REGISTRAR LA GARANTA PARA OBTENER SERVICIO DE BRIGGS & STRATTON PRODUCTS. GUARDE SU RECIBO DE COMPRA. SI NO
APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL, SE UTILIZAR LA FECHA DE FABRICACIN DEL PRODUCTO PARA DETERMINAR EL PERODO DE
GARANTA.
Desgaste normal: Al igual que cualquier otro aparato mecnico, los equipos de uso en exteriores necesitan piezas y mantenimiento peridicos para
funcionar correctamente. Esta garanta no cubre las reparaciones cuando el uso normal haya agotado la vida til de una pieza concreta del equipo.
Instalacin y mantenimiento: Esta garanta no cubre los equipos ni las piezas cuya instalacin sea incorrecta o no haya sido autorizada, ni aquellos
que hayan sido objeto de cualquier tipo de alteracin, mal uso, negligencia, accidente, sobrecarga, exceso de velocidad o mantenimiento, reparacin o
almacenamiento inadecuados que, a nuestro juicio, haya afectado negativamente a su funcionamiento y su fiabilidad. La garanta tampoco cubre el
mantenimiento normal, como los filtres de aire, los ajustes y la limpieza o la obstruccin del sistema de combustin (debido a materias qumicas,
suciedad, carbn, cal, y as sucesivamente).
Otras exclusiones: Tambin quedan excluidos de esta garanta el desgaste de los artculos tales como juntas tricas, filtros, etc., o los daos
derivados de accidentes, uso indebido, modificaciones, alteraciones, servicio inadecuado, congelacin o deterioro qumico. Los accesorios tales como
empezar bateras, juego de cables del adaptador del generador y cubiertas para almacenamiento quedan excluidos de la garanta del producto. Tambin
se excluyen los equipos usados o reacondicionados y los destinados a demostraciones; los equipos utilizados como fuente principal de energa en
lugar de un servicio pblico y los equipos sanitarios destinados al mantenimiento de las constantes vitales. Esta garanta excluye los fallos debidos a
hechos fortuitos y a otros acontecimientos de fuerza mayor que escapan al control del fabricante. 198189S, Rev. B, 12/31/2006
Espaol
23
Generador Porttil
Especificaciones del producto
Vataje que Empieza . . . . . . . . . . . . . . . .8,550 Vatios (8,55 kW)
Vataje . . . . . . . . . . . . . . . . . . . . . . . . . . .5,550 Vatios (5,55 kW)
Corriente Carga de C.A.
a 120 Voltios . . . . . . . . . . . . . . . . . . . . . . . . . .46.2 Amperios
a 240 Voltios . . . . . . . . . . . . . . . . . . . . . . . . . .23.1 Amperios
Frecuencia Nominal . . . . . . . . . . . . . . . . . . . . .60Hz a 3600 rpm
Fase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Monofsica
Capacidad de Gasolina . . . . . . . .26.5 L (7 galones americanos)
Peso que Embarca . . . . . . . . . . . . . . . . . . . . . .68 kg (150 lbs.)
Desplazamiento . . . . . . . . . . . . . . . . . .305 cc (18,61 pulgadas)
Buja Separacin . . . . . . . . . . . . . . . .0,030 pulgadas (0,76mm)
Capacidad de Aceite . . . . . . . . . . . . . . . . .0,83 litros (28 onzas)
Potencia nominal: El valor de potencia bruta de cada modelo de motor de gasolina se indica en la etiqueta conforme a los requisitos del
cdigo J1940 (Procedimiento de valoracin de potencia y par de pequeos motores) de la SAE (Society of Automotive Engineers, Sociedad
de ingenieros de automocin). Los valores nominales se han obtenido y corregido conforme al cdigo SAE J1995 (Revisin 2002-05). Los
valores de par se obtienen a 3060 rpm, y los valores de potencia, a 3600 rpm. La potencia bruta real del motor ser inferior y depender,
entre otros factores, de las condiciones ambientales de uso y de las variaciones entre distintos motores del mismo modelo. Dada la amplia
variedad de productos que utilizan nuestros motores y la multitud de factores ambientales que pueden afectar a su funcionamiento, es
posible que el motor de gasolina no desarrolle toda su potencia bruta nominal en determinados equipos (potencia en la aplicacin o neta
real). Esta diferencia se debe, entre otros, a los siguientes factores: accesorios (filtro de aire, escape, carga, refrigeracin, carburador,
bomba de combustible, etc.), limitaciones de la aplicacin, condiciones ambientales de uso (temperatura, humedad, altitud) y variaciones
entre distintos motores de un mismo modelo. Briggs & Stratton podr sustituir el motor de esta serie por otro de mayor potencia nominal
en caso de limitaciones de fabricacin o capacidad.
Briggs & Stratton Power Products Group, LLC
900 N. Parkway
Jefferson, Wisconsin, 53549 U.S.A.
24
(800) 743-4115