Etisalat Wireless Network
Modernization Project Introduction
www.huawei.com
2014-Jan-2
HUAWEI TECHNOLOGIES CO., LTD.
Page 1
BBU Main Processing & Transmission unit
LMPT (LTE Main Processing & Transmission unit)
2FE/GE electrical port, 2FE/GE optical port , Support IPSec
GTMU (GSM Transmission & Timing & Management Unit)
4E1/T1, 1FE electrical port, 1FE optical port
WMPT (WCDMA Main Processing & Transmission unit)
UMPT (Universal Main Processing & Transmission Board)
4E1/T1, 1FE electrical port, 1FE optical port
FAN
0
1
2
3
4
5
6
7
Support IPSec, GUL concurrent modeSRAN8.0
4E1/T1, 1FE/GE electrical port, 1FE/GE optical port
UPEU
UPEU
UMPT
WMPT/LMPT/UMPT inserted in slot 6/7
GTMU inserted in slot 6(both slots 5 and 6 occupied)
HUAWEI TECHNOLOGIES CO., LTD.
FE/GE (Electrical)
CI
FE/GE (Optical)
E1/T1
G/ U/L light indicator
WBBPf4/LBBPd board
Function:
Provides CPRI ports for communication with the RF modules (RRU)
Processes uplink and downlink baseband signals.
WBBPf for 3G
WBBPf inserted in slot 0/1/2/3/4/5
FAN
Interface ports: 6 (CPRI0 ~CPRI5)
0
1
2
3
4
5
6
7
UPEU
UPEU
WBBPf4: 6 cells, DL/UL: 768CE/512CE
LBBPd for LTE
LBBPd inserted in slot 0/1/2/3/4/5
FAN
Interface ports: 6 (CPRI0 ~CPRI5)
HUAWEI TECHNOLOGIES CO., LTD.
0
1
2
3
4
5
6
7
UPEU
UPEU
LBBPd3: 6x20M, 2T2R, DL/UL: 600M/300Mbps
UCIU/UBRIb board
UCIU: universal inter-connection infrastructure unit
S0
GCK
UCIU inserted in slot 4
FAN
M0 ~ M4
4
5
6
7
0
1
2
3
UPEU
UPEU
UBRIb for 2G
Provides CPRI ports for communication with the RF modules (RRU)
UBRIb inserted in slot 03
FAN
0
1
2
3
4
5
6
7
UPEU
UPEU
BBU3900
HUAWEI TECHNOLOGIES CO., LTD.
WMPT /LMPT/GTMUb evolved.
UPEU
F
A
N
UPEU
LBBP
LMPT
UPEU
F
A
N
UMPT(GUL)
LBBP
LMPT
evolved
UPEU
LMPT evolved: supports SingleOM and provides LTE signaling processing function.
HUAWEI TECHNOLOGIES CO., LTD.
BBU3900 Slot Assignment solution reusing the existing BBU
UBRIb+2G900
UBRIb+2G900
UBRIb+2G1800
UBRIb+2G1800
WBBPf+3G900
WBBPf+3G900
LBBP+4G1800
UMPT
(Existing L)
Reusing the existing 4G BBU ,existing
UMPT board, New
2G900&2G1800+3G900
HUAWEI TECHNOLOGIES CO., LTD.
LBBP+4G1800
UMPT
LMPT
(Existing L)
Reusing the existing 4G BBU ,existing
LMPT board, New
2G900&2G1800+3G900
Page 6
Existing
New
New
BBU3900 Slot Assignment solution New BBU
UBRIb+2G900
UBRIb+2G900
UBRIb+2G1800
UBRIb+2G1800
WBBf+3G900
UMPT
G+U)
UMPT G)
New 2G900&2G1800+3G900 with new BBU
New 2G900+2G1800 with new BBU
HUAWEI TECHNOLOGIES CO., LTD.
Page 7
BBU3900 Working in Multi-Mode with a Co-MPT
Typical board configurations for a BBU3900 with a UMPT_GU board
HUAWEI TECHNOLOGIES CO., LTD.
Page 8
New MiniShelter equipment layout
cable tray(1U)
spare Space(6U)
DCDU12B-3(0U)
DCDU12B-2(1U)
BBU2(2U)
spare Space(1U)
DCDU12B-1(1U)
BBU1(2U)
spare Space(2U)
Rectifier ETP48200(6U)
Battery1
Battery2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
HUAWEI TECHNOLOGIES CO., LTD.
(2.1M+AH1500&PC500D+Rack)
Item
Basic unit
specifications
Equipment Compartment
Internal dimensions: 800 mm
x 800 mm x 1800 mm (31.50
in. x 31.50 in. x 70.87 in.)
Maximum external
dimensions: 905 mm x 1135
mm x 2110 mm (35.63 in. x
44.68 in. x 83.07 in.,
Typical
temperature
control mode
AH1500 (maximum power
consumption AC/ DC 640
W/200 W)
PC500D (maximum power
consumption DC 200 W)
Integration
Power system, baseband unit
(BBU), environment
monitoring unit, alternating
current distribution box
(ACDB), and automatic
transfer switch (ATS), and so
on
IP protection
level
IP55
Weight
240 kg (529.20 lb)
Page 9
New MiniShelter installation information
Install as
single
cabinet
HUAWEI TECHNOLOGIES CO., LTD.
Cabinet bottom
base view
Page 10
New minishelter Rectifier-ETP48200
Power Specifications
Rectifier module
(PSU)
HUAWEI TECHNOLOGIES CO., LTD.
Page 11
New minishelter AC power cable connection
Single phase case
HUAWEI TECHNOLOGIES CO., LTD.
Page 12
New minishelter Battery cable connection
One string battery= 4 pcs
sell.
Battery capacity:100AH.
Weight: 124KG/string
HUAWEI TECHNOLOGIES CO., LTD.
Page 13
New minishelter Power monitoring unit
Signal resource
Minishelter
alarm list:
Alarm name
Mains failures
DC low voltage
Rectifier failures
SPD failure
Load Breaker burn-out
High temperature
Door open
Air-conditioner failures
HUAWEI TECHNOLOGIES CO., LTD.
Alarm type Power port
NO
NO
NO
NO
NO
NO
NO
NO
ALM1
ALM2
ALM3
ALM4
ALM5
ALM6
ALM7
ALM8
BBU port
UPEU
EXT-ALM1
UPEU
EXT-ALM0
Page 14
Cable color
White/orange+, Orangewhite/green+, Bluewhite/blue+, Green
white/brown ,BrownWhite/orange+, Orangewhite/green+, Bluewhite/blue+, Green
white/brown ,Brown-
New minishelter Power alarm cable connection
HUAWEI TECHNOLOGIES CO., LTD.
Page 15
New minishelter sensor cable connection
Door sensor
Battery Temperature
sensor
Temperature &
humidity sensor
sensor
HUAWEI TECHNOLOGIES CO., LTD.
Page 16
New minishelter Grounding cable connection
EMUA (1U)
Door
Space (15U)
Rack
Rack Ground Point
Indoor ground busbar
DCDU
Grounding cable
layout
SLPU1U
BBU
Power
Power
System
ETP48200
(8U)
DCDU (1U)
BBU (2U)
SLPU (1U)
Ground
HUAWEI TECHNOLOGIES CO., LTD.
12V
150Ah
12V
150Ah
12V
150Ah
12V
150Ah
12V
150Ah
12V
150Ah
12V
150Ah
12V
150Ah
Outdoor ground busbar
New TP4860C
2
System Specifications
Dimensions (H x W
x D)
630 mm x 450 mm x 300 mm (The width of the protruding part of the door [60 mm]
is extracted from the cabinet depth.)
Weight
29 kg (excluding the weights of PSUs and storage batteries)
Rated capacity
The maximum current is 60 A, in which case three 30 A PSUs are installed. 15 A
PSUs are also supported.
Installation
Mounted on a wall, floor, or pole.
Cable routing
Cables are routed out from the bottom.
Maintenance
Maintained from the front, supporting module replacement.
Protection level
IP55
Noise
The operation noise is lower than 55 dB, complying with YD/T 1058
Heat dissipation
Natural-ventilation unit
Battery (optional)
Built in with a 48 V 20 Ah/40 Ah battery string.
Electrical Specifications
Internal Components
1
2
3
4
5
PSU
PMU
Fan
Power distribution unit (PDU)
6
7
8
9
Door monitor
10
Battery Space
Baffle plate
Air Filter
HUAWEI TECHNOLOGIES CO., LTD.
AC input system
Single-phase (L-N or L1-L2. The live wire and neutral wire can be reversely
connected.)
Input voltage
85=300VAC (The rated input voltage is 220 V AC.)
Input frequency
4565 Hz (The default input frequency is 50 Hz or 60 Hz.)
Output voltage
43.258 V DC (The default output voltage is 53.5 V DC.)
AC surge protection
level
Level C (20/40 kA, 8/20 s). Level B (30/60 kA, 8/20 s) can be customized.
DC surge protection
Differential mode: 10 kA
Common mode: 20 kA
Surge protection for
signal ports
Differential mode: 3 kA
Common mode: 5 kA
New TP4860C installation information
HUAWEI TECHNOLOGIES CO., LTD.
New TP4860C installation information
HUAWEI TECHNOLOGIES CO., LTD.
New TP4860C installation information
HUAWEI TECHNOLOGIES CO., LTD.
New TP4860C installation information
Item
Rated capacity
Rated voltage
Operating temperature
Dimensions (H x W x D)
Weight
Maximum discharge power
Maximum charge current
HUAWEI TECHNOLOGIES CO., LTD.
Specifications
40 Ah
48 V DC
20C to +55C
133 mm x 385 mm x 350
mm
27 kg
1500 W (the backup time is
1 hour)
8A
New TP4860C installation information
HUAWEI TECHNOLOGIES CO., LTD.
Item
TP4860C-D06A1
AC input circuit
breaker
Maintenance socket
AC surge protection
device (SPD)
DC SPD
DC output circuit
breaker
Battery circuit
breaker
One 2-pole 32 A
circuit breaker
1
Class C, 4-pole
1
Three 1-pole 32A
circuit breakers
One 1-pole 63 A
circuit breaker
DCDU12B View
HUAWEI TECHNOLOGIES CO., LTD.
Page 24
APM30 DC(TMC11H ,Ver.D)
Power Specifications
Exterior of the APM30H(TMC11H)
Supplied with -48 V DC power.
Configured with a DCDU-12B, which distributes power into RRUs and the
BBU, fan assembly, and transmission equipment in the TMC11H
.Parameter
Specifications
Characteris Input voltage range
tics of DC Typical input voltage
input
Maximum input current
Input mode
Characteris DC distribution
tics of DC
output
Typical output voltage
Protection
HUAWEI TECHNOLOGIES CO., LTD.
-38.4 V DC to -57 V DC
-48 V DC
The maximum input current depends on the application
scenario. In a distributed base station: 160 A
In a separated macro base station: 30 A (When the TMC11H is
configured together with the APM30H, the APM30H supplies
power to the TMC11H.)
-48 V DC power input, supporting the one-hole M6 OT terminal
Ten -48 V DC outputs: LOAD0 to LOAD9, used to supply power
to the customer equipment
-48 V DC
Providing overcurrent protection and short-circuit protection for
the DC power
Page 25
APM30H DC (TMC11H ,Ver.D)
Exterior of the APM30H
Parameter
Specifications
Remarks
Dimensions (H x
W x D)
Cabinet (without the
The TMC11H and APM30H have the same
base): 700 mm x 600 mm exterior and base.
x 480 mm (27.56 in. x
23.62 in. x 18.90 in.)
Base: 200 mm x 600 mm
x 434 mm (7.87 in. x
23.62 in. x 17.09 in.)
Space for the
11 U x 19 in. x 380 mm The depth includes 100 mm (3.94 in.) in front of
customer
the columns and 280 mm (11.02 in.) between the
equipment (H x W
columns and the rear of the cabinet.
x D)
Cabinet weight
47 kg (103.64 lb)
Total weight of the equipment
Including the cabinet frame, outer air
circulation assembly (heat dissipation core and
outer air circulation fan), inner air circulation
fan assembly, DCDU, and cables
Excluding the customer transmission
equipment
Method of
It can be installed on the In stack mode, the TMC11H must be installed on
installation
ground, pole, or wall. It the top of the RFC, IBBS200D, or IBBS200T
can also be installed on
an RFC, IBBS200D, or
IBBS200T in stack mode.
HUAWEI TECHNOLOGIES CO., LTD.
Page 26
APM30 H( TMC11H VerD detail component)
No. Component
Remarks
1
Outer air
circulation
The assembly is installed on the front door of the cabinet, dissipating heat from the cabinet.
assembly
2
The junction box converts one AC input to four AC outputs and is used in the scenario where a service outlet unit (SOU) and
Junction box
multiple heating films or heaters are configured.
3
FAN 02D
The fan assembly is configured with fans and central monitoring unit type EA (CMUEA), dissipating heat from the cabinet.
4
To provide protection for trunk signals,
SLPU
To provide protection for monitoring signals.
5
Door sensor The door status sensor monitors the status (open or closed) of the cabinet door.
6
ELU
The electronic label unit (ELU) reports the cabinet type automatically to facilitate troubleshooting.
7
The direct current distribution unit-12B (DCDU-12B) or direct current distribution unit-12C (DCDU-12C) in the TMC11H
DCDU-12B or
distributes DC power to all the components in the TMC11H. A DCDU-12B or DCDU-12C is 1 U high. The DCDU varies with the
DCDU-12C
installation scenarios.
8
BBU3900
A maximum of two BBU3900s can be configured in a TMC11H.
9
EMUA
The environment monitoring unit type A (EMUA) monitors environment of the equipment.
10
A filler module is a plastic component with a height of 1 U in the cabinet, preventing the heat reflux in the empty space below the
Filler module
BBU.
11
The AC heater ensures that components in the cabinet work within the acceptable temperature range when the surrounding
AC heater
temperature is low. It can be preferentially installed in the 1 U space at the bottom of the cabinet.
HUAWEI TECHNOLOGIES CO., LTD.
Page 27
APM30 AC (Ver.D)
Power Specifications
Exterior of the APM30H AC
Item
Specifications
200 V AC to 240 V AC (220 V AC single-phase)
200/346 V AC to 240/415 V AC (220/380 V AC three-phase)
Typical input voltage
100/200 V AC to 120/240 V AC (110 V AC dual-live-wire)
Characteristics of AC input
120/208 V AC to 127/220 V AC (120 V AC dual-live-wire)
Rated input current
Output voltage range
Output current range
Typical output voltage
53 A (220 V AC single-phase)
23 A (220/380 V AC three-phase)
55 A (110 V AC dual-live-wire)
52 A (120 V AC dual-live-wire)
-43.2 V DC to -57 V DC
0 A to 150 A
-53.5 V DC
The number of DC outputs depends on the application scenario.
Characteristics of DC output
DC outputs
A distributed base station uses 17 DC outputs
A separated base station uses 12 DC outputs.
DC output power
HUAWEI TECHNOLOGIES CO., LTD.
9000 W (When there is no backup PSU, the maximum power of each PSU is
3000 W.)
Page 28
APM30H AC (Ver.D)
Item
Exterior of the APM30H
Specification
68 kg
Weight
87 kg
Cabinet dimensions (H x W x D)
700 mm x 600 mm x 480 mm The base is not included.
Base dimensions (H x W x D)
200 mm x 600 mm x 434 mm -
Customer equipment dimensions (H
7 U x 19 in. x 380 mm
x W x D)
The depth consists of the rear (280 mm)
and front (100 mm) of the installation
plane for subrack mounting ears.
Space for cabling and maintenance
70 mm
in front of the cabinet
Installation option
HUAWEI TECHNOLOGIES CO., LTD.
Remarks
Total weight of the equipment
Including the cabinet frame, inner air
circulation fan box, outer air circulation
fan box, core of the heat exchanger,
embedded power subrack unit (EPU),
and cables
Excluding the baseband processing unit
(BBU), customer equipment, power
monitoring unit (PMU), and PSUs
Weight of the cabinet in full configuration
Including the cabinet, one PMU, three
PSUs, and one BBU
Excluding customer equipment
The APM30H can be installed
on a floor, wall, or pole. It can
also be stacked with the radio The APM30H must
frequency cabinet (RFC),
IBBS200D, or IBBS200T.
Page 29
APM30H AC-APM30H+Battery(Used for a Distributed Base Station)
Figure 1 Scenario where the APM30H is stacked with a battery cabinet and is used for a distributed base station
When the APM30H is used for a distributed
base station:
The APM30H provides 7 U-high space for
installing the BBU and transmission
equipment. The embedded power supply
system provides -48 V DC power to the
distributed base station and transmission
equipment and charges battery groups in a
battery cabinet.
When no mains are available, the battery
groups in a battery cabinet provide -48 V DC
power to the distributed base station and
transmission equipment
HUAWEI TECHNOLOGIES CO., LTD.
Page 30
APM30H AC-BTS3900A(Used for an Outdoor Macro Base Station)
Figure 2 Scenario where the APM30H is used for an outdoor macro base station
When the APM30H is used for an outdoor
macro base station:
The APM30H provides 7 U-high space for
installing the baseband processing unit (BBU)
and transmission equipment. The embedded
power supply system provides -48 V DC power
to the BBU, radio frequency unit (RFU), and
transmission equipment and charges battery
groups in a battery cabinet.
When no mains are available, the battery
groups in a battery cabinet provide -48 V DC
power to the BBU, RFU, and transmission
equipment.
The APM30H provides alarm reporting functions
for radio frequency cabinet (RFC) fans, door
status sensor, direct current distribution unit
(DCDU), and battery cabinet.
HUAWEI TECHNOLOGIES CO., LTD.
Page 31
OMB (Ver.C)
The OMB (Ver.C) is designed for SRAN8.0 and later versions
Base stations supported by the OMB (Ver.C):
DBS3900
The OMB (Ver.C) supports all current RRU versions.
DBS3900 (AC)
DBS3900 (DC)
Page 32
HUAWEI TECHNOLOGIES CO., LTD.
OMB (Ver.CMPE Specifications ) in AC Scenarios
Dimensions (H x W x D)
600 mm x 240 mm x 430 mm (23.62 in. x 9.45 in. x 16.92 in.)
Temperature Range
-33oC to 50oC (-27.4oF to 131oF)
Weight
30 kg or 66.15 lb (without a BBU)
Protection Class
IP55
Admission Requirement
CE
Power Supply Mode
110 V AC dual-live-wire or 220 V AC single-phase
Temperature Control Subsystem
Heat exchanger
Power Supply Subsystem
ETP48100-A1
Embedded power system, with a maximum power capacity of 100 A
Power Distribution Subsystem
Ten power outputs of 30 A
Output DC power distribution: two 100 A outputs
AC power port: rated 20 kA; maximum 40 kA; 8/20 us waveform
Surge Protection
DC power output port: 10 kA in differential mode and 20 kA in
common mode; 8/20 us waveform
Cable Outlet Position
Bottom of the cabinet
Page 33
HUAWEI TECHNOLOGIES CO., LTD.
Structure and Components of the OMB in AC
Scenarios
1
2
3
4
5
6
7
8
10
No.
Configuration
Description
Mandatory
Electronic label unit (ELU)
Mandatory
FAU01D-01 (inner air circulation fan
assembly)
Mandatory
Door status sensor
Mandatory
SPD40/S (AC surge protector)
Mandatory
HEUB (control unit for heat
exchanging)
Mandatory
PMU11A (power management unit)
Mandatory
PSU (R4850G2 rectifier)
Mandatory
PDU10D-01 (DC power distribution
unit)
Mandatory
ETP48100-A1 (embedded power
system)
10
Mandatory
FAU01D-01 (outer air circulation
fan assembly)
Page 34
HUAWEI TECHNOLOGIES CO., LTD.
OMB (Ver.C) MPE Specifications in DC Scenarios
Dimensions (H x W x D)
600 mm x 240 mm x 430 mm (23.62 in. x 9.45 in. x 16.92 in.)
Temperature Range
-33oC to 50oC (-27.4oF to 131oF)
Weight
21 kg or 46.31 lb (without a BBU)
Protection Class
IP55
Admission Certification
CE
Power Supply Mode
-48 V DC
Temperature Control
Subsystem
Heat exchanger
Power Distribution
Subsystem
Ten power outputs of 30 A
Surge Protection
DC power output port: 10 kA in differential mode and 20 kA in common mode;
8/20 us waveform
Cable Outlet Position
Bottom of the cabinet
Page 35
HUAWEI TECHNOLOGIES CO., LTD.
Structure and Components of the OMB in DC
Scenarios
1
2
3
4
5
6
No.
Configuration
Description
Mandatory
ELU
Mandatory
FAU01D-01 (inner air circulation fan
assembly)
Mandatory
Door status sensor
Mandatory
HEUB (control unit for heat
exchanging)
1 U space for customer equipment
Mandatory
PDU10D-01 (DC power distribution
unit)
Mandatory
FAU01D-01 (outer air circulation fan
assembly)
Page 36
HUAWEI TECHNOLOGIES CO., LTD.
Engineering Interface of the OMB (Ver.C)
Engineering Interface of the OMB (Ver.C) in AC Scenarios
AC Input Mode
Number of PSUs
Requirements
Breakers
for
AC
Circuit
Input Power Cable
220 V AC single-phase
32 A, 1 P
4 mm2
110 V AC dual-live-wire
32 A, 2 P
4 mm2
220 V AC single-phase
20A, 1 P
4 mm2
110 V AC dual-live-wire
20 A, 2 P
4 mm2
Remarks
The circuit breaker is connected to the L phase.
The circuit breaker is connected to the L phase.
Engineering Interface of the OMB (Ver.C) in DC Scenarios
Related Unit
Configuration
RRU Power
Number of
RRUs
BBU: 450
300 W
1~3
50A, 1 P
16 mm2
5m
300 W
4~6
80 A, 1 P
16 mm2
5m
RRUs of
the same
model
400 W
1~3
63 A, 1 P
16 mm2
5m
400 W
4~6
100 A, 1 P
16 mm2
5m
mm2
5m
Input Power
Cable
Distance Between the OMB (Ver.C)
and External Power Equipment
560 W
1~3
80 A, 1 P
16
560 W
4~6
125 A, 1 P
25 mm2
5m
2x60 A, 2 P
2x16 mm2
5m
80 A, 1 P
16 mm2
5m
300 W
300 W
RRUs of
different
models
400 W
BBU: 450
Requirements for
DC Circuit Breakers
300 W
400W
1.
core cables, each with dual insulation
layers.
2.
Therefore, ensure that the circuit
breakers and power cables meet the
requirements before the PSUs are
100 A, 1 P
16
mm2
5m
100 A, 1 P
16 mm2
5m
added.
Page 37
HUAWEI TECHNOLOGIES CO., LTD.
If more PSUs are added, the customer
engineering interface must be changed.
560 W
400 W
The AC input power cables are single-
Application Scenarios of the OMB (Ver.C)
Rooftop Outdoor-S2
Greenfield Outdoor-
Urban Street-S5
Indoor-S6
Rural Road-S7
S4
Installing on
Installing on
Installing on
the pole of
the bottom of
the Lamp pole
rooftop
the tower
of the street
Installing on
the wall of
side
Installing on
Installing on
the carport
the pole of
Installing on
the road side
the wall of
veranda
rooftop
Page 38
HUAWEI TECHNOLOGIES CO., LTD.
Stacking the OMB (Ver.C) onto the Top of the BTS3900A
Item
Quantity
Description
Adapting piece I
Secured to the lifting eyes on the
top of the BTS3900A
Adapting piece IV
Used to secure adapting piece I to
the rear of the OMB
The solution of stacking the OMB (Ver.C) onto the BTS3900A is
carried out only as a non-standard solution.
Adapting piece I
Adapting piece IV
Page 39
HUAWEI TECHNOLOGIES CO., LTD.
The changes from OMB Ver.A to OMB Ver.C
AC SPD
SPD40/S
OMB Ver.A
OMB Ver.C
New ELU
unit
New PDU
EPS30-4815AF
HUAWEI TECHNOLOGIES CO., LTD.
ETP48100-A1
Page 40
DBS3900 (-48 V): Outdoor BBU and Outdoor RRUs (Ver.C)
Solution: OMB(-48 V) + 6 x RRU (optional)
DC power cable
A DC OMB Ver.C supports a maximum of six 2x60 W RRUs.
ground cable
The heat consumption of a DC OMB Ver.C cabinet (the total heat consumption of the built-in
feeder
BBC and TC) is lower than or equal to 450 W (with the urban-level noise and in ambient
Optical fiber
temperature of 50C.)
The DC OMB Ver.C supports -48 V power input.
The protection level of the DC OMB Ver.C is IP55.
RR
U
OMB V.C
Power interface
ACDB
The DC input/output port surge protection specification is 10KA/20KA.
The DC OMB Ver.C supports both wall mounting and floor mounting. It can be installed both
on the top of and beside a BTS3900A. In this case, an attachment plate is required and no
footprint is required.
The DC OMB Ver.C can operate in a temperature range of -33C to +50C.
For the power supply requirements, see the Power Supply Interface Requirements for Wireless
Base Stations.
Customer side
Page 41
HUAWEI TECHNOLOGIES CO., LTD.
Back
DBS3900 (AC): Outdoor BBU and Outdoor RRUs (Ver.C)
Solution: OMB (AC) + 6 x RRU (optional)
An AC OMB Ver.C supports a maximum of six 2x60 W RRUs (power backup is not supported when the
load power exceeds 3000 W).
AC power cable
ground cable
feeder
DC power cable
optical fiber
An AC OMB Ver.C has a built-in ETP48100 power supply system and two PSUs, with a maximum output
power of 6000 W (3000 W for a single PSU.)
The AC OMB Ver.C supports 220 V single-phase and 110 V dual-live-wire AC input.
The heat consumption of an AC OMB Ver.C cabinet is lower than or equal to 450 W (the heat consumption
of the BBU is lower than or equal to 250 W) with the urban-level noise and in ambient temperature of
RRU
50C.
The protection level of the AC OMB Ver.C is IP55.
OMB V.C
Power interface
ACDB
The AC OMB Ver.C cannot be installed on a tower and can not be installed at a position higher than 10 m.
The AC OMB Ver.C supports remote RRU.
The AC OMB Ver.C supports a surge protection of a maximum of 40 KA at the AC power input port and 10
KA/20 KA at the DC power output port.
The AC OMB Ver.C supports both wall mounting and floor mounting. It can be installed both on the top of
and beside a BTS3900A. In this case, an attachment plate is required and no footprint is required.
Customer side
The DC OMB Ver.C can operate in a temperature ranging from of -33C and +50C.
Power backup is not supported.
For the power supply requirements, see the Power Supply Interface Requirements for Wireless Base
Stations.
Page 42
HUAWEI TECHNOLOGIES CO., LTD.
Back
DBS Senario
Existing
transmission
equipment
CPRI optical
HUAWEI TECHNOLOGIES CO., LTD.
Page 43
DBS Structure
HUAWEI TECHNOLOGIES CO., LTD.
Page 44
CPRI Cable
Branch of Cable
Appearance of Figure
HUAWEI TECHNOLOGIES CO., LTD.
Connected to Equipment
Page 45
CPRI Cable
Single mode/Multi-mode
Length of branch
Connect to
Connector
CPRI
BBU-RRU
DLC/PC-DLC/PC
Cores
2
CPRI
BBU-RRU
DLC/PC-DLC/PC
0.03m/0.34m
CPRI
BBU-RRU
DLC/PC-DLC/PC
30m
0.03m/0.34m
CPRI
BBU-RRU
DLC/PC-DLC/PC
40m
0.03m/0.34m
CPRI
BBU-RRU
DLC/PC-DLC/PC
Multi-mode
50m
0.03m/0.34m
CPRI
BBU-RRU
DLC/PC-DLC/PC
Multi-mode
60m
0.03m/0.34m
CPRI
BBU-RRU
DLC/PC-DLC/PC
Multi-mode
80m
0.03m/0.34m
CPRI
BBU-RRU
DLC/PC-DLC/PC
Multi-mode
100m
0.03m/0.34m
CPRI
BBU-RRU
DLC/PC-DLC/PC
Multi-mode
120m
0.03m/0.34m
CPRI
BBU-RRU
DLC/PC-DLC/PC
Multi-mode
150m
0.03m/0.34m
BBU-RRU
DLC/PC-DLC/PC
Single mode
5m
0.34m/0.8m
CPRI
CPRI/Iub
BBU-ODF
DLC/UPC-2FC/UPC
0.34m/0.8m
CPRI/Iub
BBU-ODF
DLC/UPC-2FC/UPC
0.34m/0.8m
CPRI/Iub
BBU-ODF
DLC/UPC-2FC/UPC
BBU-ODF
DLC/UPC-2SC/UPC
Multi-mode
Length
5m
0.03m/0.34m
Multi-mode
10m
0.03m/0.34m
Multi-mode
20m
Multi-mode
Multi-mode
Single mode
Single mode
10m
20m
Be used
Single mode
10m
0.34m/0.8m
CPRI/Iub
Single mode
20m
0.34m/0.8m
CPRI/Iub
BBU-ODF
DLC/UPC-2SC/UPC
Single mode
10m
0.34m/0.8m
CPRI/Iub
BBU-ODF
DLC/UPC-2LC/UPC
Single mode
20m
0.34m/0.8m
CPRI/Iub
BBU-ODF
DLC/UPC-2LC/UPC
Single mode
5m
0.03m/0.8m
CPRI
RRU-ODF
DLC/UPC-2FC/UPC
Single mode
10m
0.03m/0.8m
CPRI
RRU-ODF
DLC/UPC-2FC/UPC
Single mode
20m
0.03m/0.8m
CPRI
RRU-ODF
DLC/UPC-2FC/UPC
Single mode
30m
0.03m/0.8m
CPRI
RRU-ODF
DLC/UPC-2FC/UPC
Single mode
50m
0.03m/0.8m
CPRI
RRU-ODF
DLC/UPC-2FC/UPC
Single mode
10m
0.03m/0.8m
CPRI
RRU-ODF
DLC/UPC-2SC/UPC
Single mode
Single mode
Multi-mode
10m
10m
10m
0.03m/0.8m
0.03m/0.03m
0.03m/0.03m
CPRI
CPRI
CPRI
RRU-ODF
RRU-RRU
RRU-RRU
DLC/UPC-2LC/UPC
DLC/UPC-DLC/UPC
DLC/UPC-DLC/UPC
HUAWEI TECHNOLOGIES CO., LTD.
Page 46
2
2
Existing Transmission SmartAXOT928G-D
HUAWEI TECHNOLOGIES CO., LTD.
Page 47
RRU3936
RRU dimensions
Ports on the RRU panels
RTN(+) / NEG(-) -- Power supply socket
CPRI0/1-- Optical/electrical port 0, connected to the BBU
(2) ANT_TX/RXA TX/RX port A-- supporting RET signal transmission
ANT_RXB RX-- port B
HUAWEI TECHNOLOGIES CO., LTD.
Page 48
RRU installation on pole
One RRUs installed on a pole
Two RRUs installed on a pole
HUAWEI TECHNOLOGIES CO., LTD.
Three RRUs installed on a pole
If on ground
RRU installation on wall
RRU installed on the wall
HUAWEI TECHNOLOGIES CO., LTD.
RRU installation inside shelter
Installing RRUs on the lower level-1
Indoor IFS06
HUAWEI TECHNOLOGIES CO., LTD.
Installing RRUs on the lower level-2
Indoor IFS06
RRU 3936 DC
RRU3936 Multi-mode 900MHz EGSM RRU3826
Port
Connector
Quantity
Function
Item
Specifications
RF port
DIN
Connects to an antenna
Common public
radio interface
(CPRI) port
DLC
Connects to the baseband unit
(BBU3900)
Dimensions (H x
W x D)
400 mm x 240 mm x 160 mm (with the
housing)
Power supply socket
Easy power
receptacle (pressfit
type)
DB9
RET port
400 mm x 220 mm x 140 mm (without
the housing)
Receives 48 V DC power
Weight
15 kg (with the housing)
Connects to a remote control
unit (RCU)
Item
Specifications
Input power
48 V DC; voltage range: 36 V DC to 57 V DC
13.5 kg (without the housing)
The RRU3936 supports AC applications after being configured with an AC/DC power module. For details, see the AC/DC Power
Module User Guide.
HUAWEI TECHNOLOGIES CO., LTD.
Page 52
Jumper Connector Type
Types of connectors for jumpers
HUAWEI TECHNOLOGIES CO., LTD.
Page 53
Jumper Connector Type
Difference between the male connector and female connector
HUAWEI TECHNOLOGIES CO., LTD.
Page 54
Jumper Connector Type
Difference between the DIN connector and N connector
HUAWEI TECHNOLOGIES CO., LTD.
Page 55
Optical Connector and Flange
SC optical connector and flange
HUAWEI TECHNOLOGIES CO., LTD.
Page 56
Optical Connector and Flange
LC optical connector and flange
FC optical connector and flange
HUAWEI TECHNOLOGIES CO., LTD.
Page 57