File No.
E471457
Technical Data Sheet
Sigma Series DE Meter
The moving iron panel meters, DE 48/72/96/144 are housed in a moulded polycarbonate
cases which are suitable for the measurement of AC currents for frequency range of 15...400Hz and
voltages in the frequency range of 15...100Hz.
Special Features
Scale interchangeability
Near linear scale
Glass lled polycarbonate housing (UL 94 V-0)
Knife edge pointer
Easily replace able glass and bezel
Sigma Series DE Meter
Application
The moving iron panel meters, DE 48/72/96/144 housed in moulded polycarbonate cases are suitable for
the measurement of AC currents for frequency range of 15...400Hz and voltages in the frequency range of
15...100Hz.
Movement
Moving iron movement has pivots of very high hardness.Movement suspended between spring loaded
saphire jewel and silicon jewel.Movement is critically damped by use of silicon oil.
Over Range
Ammeters
2 times nominal current
Applicable Standards
Voltmeters
1.2 times nominal voltage
Nominal case and cutout dimensions DIN IEC 61554
for indicating Electrical instruments
Scale Interchangeability
Interchangeable
Flame retardant & drip proof
As per UL 94 V-0
Scale and pointer for electrical
measuring instruments
DIN 43802
Connections and Terminal markings
DIN 43807
Terminal bolts/leads
DIN 46200/46282
Case details
Safety requirements and protective
measures for Electrical indicating.
instruments and their accessories
DIN 40050,
VDE 0110, VDE 0410
IEC 529, IEC 1010
Case material
Polycarbonate , ame retardant and drip
proof as per UL 94 V-0.
Performance specications for direct
acting indicating analogue electrical
measuring instruments and their
accessories
IEC51/DINEN60051
DIN 43701
Front facia
Glass
Colour of bezel
Black
Environmental conditions
VDE / VDI 3540
Position of use
Vertical
Panel xing
Mounting Clamp
Mounting
Stackable in a single cutout
Panel thickness
< 25 mm
Front frames for indicating
measuring instruments Principle
dimensions
DIN 43718
UL Compatibility
UL 94 V-0
Mechanical Data
Moulded square case suitable for mounting
in Control / switchgear panels Machinery
consoles.
Terminals
Comply with following European directives
2004 / 108 / EC (EMC directive ), 2006 / 95/EC ( low voltage
directive ) & amendment 93/68/EEC, For CE Marking.
Voltmeters and Ammeters
< 30 A
Hexagon studs, M4 screws and
wire clamps E3
Scale and Pointer
Ammeters < 30 A
Threaded studs M6 with Nuts
Ammeters < 60A
Threaded Studs M8 with Nuts
Pointer
Knife - edge pointer
o
Pointer deection
0...90
Scale characteristics
Near Linear above 10%
of nominal full Scale
value
Scale division
Coarse - ne
Scale length
DE 48
www.sifamtinsley.com
Electral Data
DE72
DE 96
DE144
41 mm 63mm
97mm
146mm
Page 1 of 5
Version No. :APMDE/2015/02
Sigma Series DE Meter
Electrical Data
Environmental Conditions
Measured Quantity Power
Consumption
AC Voltage or current
Voltmeters
< 4.5 VA
Ammeters < 15A
< 0.5 VA
Ammeters > 15A
< 0.8 VA
Continuous Overload Capacity
I (acc. to IEC 51)
1.2 times rated voltage /
current.
Short Duration
Voltameters
Ammeters
Enclosure code (IEC 529)
2 times for 0.5 sec : 9 overloads
2 times 5 sec : 1 overloads
10 times for 0.5 sec : 9 overloads
10 times for 5 sec : 1 overload
Climatic Suitability
Climate category II as per IEC 60051
(climatic class 3 according to
VDE/VDI 3540)
Operating Temperature
- 10... + 55 C
Storage temperature
- 25...+65 C
Relative humidity
< 75% annual average, noncondensing
Shock resistance
15 g. for pulse duration 11ms
Vibration resistance
10-55-10Hz for ampli. 0.15mm (1.5g
at50Hz)
Pollution degree
Stackable in a single cutout
Standard Measuring Ranges
IP 52 case
IP 00 for terminals without back cover
IP 20 for terminals with back cover
A.C. Voltage
A.C. Current
6V
100mA
10V
150mA
15V
250mA
25V
400mA
40V
600mA
60V
1A
Reference Conditions
100V
1.5A
Accuracy class
0.5 according to IEC 51/DIN
EN 60051)
120V
2.5A
132V
4A
Ambient temperature
23 C 2C
150V
5A
Position of use
Nominal position 1
250V
6A
Input Waveform
Rated value of measured quantity
sine wave, distortion factor < 5%
400V
10A
Freequency
65Hz
500V
15A
Other Conditions
IEC 51/DIN EN 60051
600V
20A
1000V
25A
for use with PT
40A
.../100 V secondary
50A (except DE 48)
.../110 V secondary
60A (except DE 48)
Insulation class
Group A according to VDE 0110
Rated insulation
DE 48 : 660V DE 72/96 : 1KV
Proof voltage
DE 48 : 2KV DE 72/96 : 3KV
Installation category
> 50 Mohm at 500 V DC
Nominal Range of use
Ambient Temperature
0 ...50 C
Position of use
Vertical 5
Frequency
45 ...65Hz
100A (except DE 48)
External Magnetic Field
At 0.4 kA/m
For use with CT
.../1A secondary
.../5A secondary
www.sifamtinsley.com
Page 2 of 5
Version No. :APMDE/2015/02
Sigma Series Alpha
DE Meter
70
Options
Electrical Connections
Case
Front Facia
Antiglare glass
Color of bezel
Red, yellow, blue, white
Red index pointer
Front adjustable on site
Position of use
on request 15...180
AC Voltage (Direct connected)
11
L1
Dial
Blank dial
12
N(L2)
With initial and end values
marked
AC Current (Direct connected)
Special markings
Numbering/Lettering
Division dials
Basic divisions without
numbering
Color markings/bands
Red or green
Over range
Two, three and ve times over
range
(Ammeters)
Six times over range
11
12
11
12
L1
N(L2)
AC Current (for use on current
Transformer)
k l
Accessories
L1
Safety Terminal Protection
Full sized polycarbonate back cover to provide protection against
accidental contact (hand and ngers) acc.to VDE 0410.
N(L2)
Dimensions
Safety Precautions
I1 x I 2
a 1 x a2
1) Instruments with damaged bezel or glasses must be
disconnected from the mains.
2) Adequate safety clearance must be maintained to control panel
fasteners and to sheet metal housing. If non - insulated
connector wires are used.
3) The back cover must be snapped into place after connector
wires have been clamped for protection against accidental
contact.
4) Bezel, Scale and Glass may only be replaced under voltage free
conditions.
5) Instruments to be used in grounded panel.
www.sifamtinsley.com
Page 3 of 5
Version No. :APMDE/2015/02
Sigma Series DE Meter
Front in mm Nominal Dimensions, mm
a 1x a 2
h
48 x 48
72 x 72
96 x 96
48 x 48
72 x 72
96 x 96
5.5
5.5
5.5
Cutout, mm
Installation Depth Including Terminal (t), mm
I1 x I2
+0.6
Installation Depth Incl. Full back Cover (f), mm
< 30A (M4) 30...60A(M6) 100A (M8)
+0.6
45 x 45
+0.7
+0.7
68 x 68
+0.8
+0.8
92 x 92
54
54
54
72
62
62
66
66
< 30A
30...100A
62.5
62.5
62.5
75(upto 60A)
70
70
Ordering Information- Only For Representative Products
Size: 48 x 48 Ammeter
Part No.
Description
Class
EQ44-V67X2N1CAW0ST
250V, Scale 0 - 250V
CL-1
EQ44-I1112N1CAW0ST
5A, Scale 0-5A
CL-1
EQ44-V68X2N1CAW0ST
300V, Scale 0- 300V
CL-1
EQ44-I1312N1CAW0ST
10A, Scale 0-10A
CL-1
EQ44-V69X2N1CAW0ST
400V, Scale 0 - 400V
CL-1
EQ44-I1412N1CAW0ST
15A, scale 0-15A
CL-1
EQ44-V70X2N1CAW0ST
500V, Scale 0 - 500V
CL-1
EQ44-I1512N1CAW0ST
20A, Scale 0-20A
CL-1
EQ44-V71X2N1CAW0ST
600V, Scale 0 - 600V
CL-1
EQ44-I1612N1CAW0ST
25A, Scale 0-25A
CL-1
EQ44-I1812N1CAW0ST
40A, Scale 0-40A
CL-1
EQ44-I2012N1CAW0ST
60A, Scale 0-60A
CL-1
Description
Class
Size: 72 x 72 Voltmeter
Part No.
Size: 72 x 72 Ammeter
Part No.
EQ74-I11X2N1CAW0ST
5A, Scale 0-5A
CL-1
EQ74-I13X2N1CAW0ST
10A, Scale 0-10A
CL-1
EQ74-I14X2N1CAW0ST
15A, scale 0-15A
CL-1
EQ74-I15X2N1CAW0ST
20A, Scale 0-20A
CL-1
EQ74-I16X2N1CAW0ST
25A, Scale 0-25A
CL-1
EQ74-I18X2N1CAW0ST
40A, Scale 0-40A
CL-1
EQ74-I20X2N1CAW0ST
60A, Scale 0-60A
CL-1
Description
Class
EQ74-V60X2N1CAW0ST
120V, Scale 0 -120V
CL-1
EQ74-V61X2N1CAW0ST
132V, Scale 0 -132V
CL-1
EQ74-V63X2N1CAW0ST
150V, Scale 0 - 150V
CL-1
EQ74-V65X2N1CAW0ST
200V, Scale 0 - 200V
CL-1
EQ74-V66X2N1CAW0ST
230V, Scale 0 - 230V
CL-1
EQ74-V67X2N1CAW0ST
250V, Scale 0 - 250V
CL-1
EQ74-V68X2N1CAW0ST
300V, Scale 0- 300V
CL-1
EQ74-V69X2N1CAW0ST
400V, Scale 0 - 400V
CL-1
EQ74-V70X2N1CAW0ST
500V, Scale 0 - 500V
CL-1
EQ74-V71X2N1CAW0ST
600V, Scale 0 - 600V
CL-1
Size: 96 x 96 Ammeter
Part No.
Description
Size: 96 x 96 Voltmeter
Class
EQ94-I1112N1CAW0ST
5A, Scale 0-5A
CL-1
EQ94-I1312N1CAW0ST
10A, Scale 0-10A
CL-1
EQ94-I1412N1CAW0ST
15A, scale 0-15A
CL-1
EQ94-I1512N1CAW0ST
20A, Scale 0-20A
CL-1
EQ94-I1612N1CAW0ST
25A, Scale 0-25A
CL-1
EQ94-I1812N1CAW0ST
40A, Scale 0-40A
CL-1
EQ94-I2012N1CAW0ST
60A, Scale 0-60A
CL-1
Part No.
Size: 48 x 48 Voltmeter
Part No.
Description
Class
EQ94-V60X2N1CAW0ST
120V, Scale 0 -120V
CL-1
EQ94-V61X2N1CAW0ST
132V, Scale 0 -132V
CL-1
EQ94-V63X2N1CAW0ST
150V, Scale 0 - 150V
CL-1
EQ94-V65X2N1CAW0ST
200V, Scale 0 - 200V
CL-1
EQ94-V66X2N1CAW0ST
230V, Scale 0 - 230V
CL-1
EQ94-V67X2N1CAW0ST
250V, Scale 0 - 250V
CL-1
EQ94-V68X2N1CAW0ST
300V, Scale 0- 300V
CL-1
EQ94-V69X2N1CAW0ST
400V, Scale 0 - 400V
CL-1
Description
Class
EQ44-V60X2N1CAW0ST
120V, Scale 0 -120V
CL-1
EQ94-V70X2N1CAW0ST
500V, Scale 0 - 500V
CL-1
EQ44-V61X2N1CAW0ST
132V, Scale 0 -132V
CL-1
EQ94-V71X2N1CAW0ST
600V, Scale 0 - 600V
CL-1
EQ44-V63X2N1CAW0ST
150V, Scale 0 - 150V
CL-1
EQ44-V65X2N1CAW0ST
200V, Scale 0 - 200V
CL-1
EQ44-V66X2N1CAW0ST
230V, Scale 0 - 230V
CL-1
www.sifamtinsley.com
Page 4 of 5
Version No. :APMDE/2015/02
Sigma Series DE Meter
For more details and product codes, please contact our local ofce
Sifam Tinsley Instrumentation Inc.
3105, Creekside Village Drive,
Suite No. 801, Kennesaw,
Georgia 30144 (USA)
E-mail Id : [email protected]
Web : www.sifamtinsley.com
Contact No. : +1 404 736 4903
www.sifamtinsley.com
Page 5 of 5
Sifam Tinsley Instrumentation Ltd
Unit 1 Warner Drive,
Springwood Industrial Estate
Braintree, Essex, UK, CM72YW
E-mail:
[email protected]Web: www.sifamtinsley.com/uk
Contact: +44(0)1803615139
Version No. :APMDE/2015/02