The Huawei OptiX 155/622H is an optical transmission system used for optical networking. It supports various services including SDH, PDH, Ethernet, ATM, audio, and data. It has multiple slots that can accommodate different interface boards to provide services over optical and electrical interfaces like STM-1, E1, Ethernet, and more. The SS42SP2 is an E1 electrical interface board that can be installed in the OptiX 155/622H to transmit and receive 16 E1 signals and process path overheads and alarms.

Uploaded by

Teddy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
3K views7 pages

Huawei Optix 155 (622h) (Metro 1000) Description PDF

The Huawei OptiX 155/622H is an optical transmission system used for optical networking. It supports various services including SDH, PDH, Ethernet, ATM, audio, and data. It has multiple slots that can accommodate different interface boards to provide services over optical and electrical interfaces like STM-1, E1, Ethernet, and more. The SS42SP2 is an E1 electrical interface board that can be installed in the OptiX 155/622H to transmit and receive 16 E1 signals and process path overheads and alarms.

Uploaded by

Teddy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 7

Official Huawei OptiX 155/622H PCM Optical

Transmission Equipment
Quick Details

Place of Origin: China (Mainland)


Brand Name: Huawei
Model Number: Metro 1000
Type: Optical transmission system
Model: OptiX 155/622H
SDH Service Type: 16*STM-1(o)/6*STM-1(e)/8*STM-4/2*STM-16(o)
PDH Service Type:112*E1/72*T1/9*E3/9*T3
Ethernet service Type:24*FE(e)/8*FE(o)/3*GE(o)
DDN service Type: 12*N*64 kbit/s(N31)/48*Framed E1
SHDSL service Type: 24*SHDSL (E1, N*64 kbit/s)
ATM service Type: 2*STM-1 ATM/4*STM-1 ATM
Audio and data service Type: 12*audio +4*RS-232 +4*RS-422
Dimension(W*D*H): 436 mm x 293mm x 86 mm
Packaging & Delivery

Packaging Details:

Original Huawei Carton package

Delivery Detail:

Within 7 days after the receipt of the payment

The OptiX 155/622H(also named Metro1000) is used in optical


transmission system .
The OptiX 155/622H is a type of STM-1/STM-4/STM-16 case-shaped equipment
.
The OptiX 155/622H can access multiple types of services and can be used at
the access layer of metropolitan area networks (MANs) and local transmission
networks to access VIP private lines, wireless base stations, and digital
subscriber line access multiplexers (DSLAM).

Appearance

Fan board: dissipates heat for the equipment.

Air filter and power filter board: The air filter dissipates heat for the
equipment together with the fan board. The power filter board inputs power
for the equipment.

Board area: houses service boards and system control boards, and
provides service, monitoring and management interfaces.

Application in Network

Features
High Integration

Chassis dimensions: 442 mm (W) x 220 mm (D) x 43.6 mm (H)


Flexible MADM Design

Supports 21.25 Gbit/s higher order cross-connections, and 5 Gbit/s lower


order cross-connections

Supports networking topologies including point-to-point, chain, ring, hub,


and mesh, etc
Various Service Interfaces

SDH/PDH service

Ethernet service

ATM service

Audio and data service

DDN service

G.SHDSL
Smooth Evolution Capacity

Supports smooth evolution from STM-1 to STM-4 and to STM-16


Highly Reliable Design

Equipment-level: 1+1 hot backup for the power supply

Network-level: Linear multiplex section protection (LMSP), Ring MSP, Sub


network connection protection (SNCP), Protection for inter-ring services,
Fiber-shared virtual path protection
Flexible Process for DCC

Supports transparent transmission of the DCC bytes and management


information transmission through the external clock interface to realize
hybrid networking and unified network management
IEEE 1588 V2 Clock Synchronization

Provides high-precision time synchronization to meet power, finance, and


other industry requirements

Slot
Allocation

Boards of the OptiX 155/622H


Board
Name
OI2S
OI2D
SL1O
SL1Q

Full Name
1xSTM-1
board
2xSTM-1
board
8xSTM-1
board
4xSTM-1

Valid Slot

Description

optical interface

IU1, IU2, and IU3

Ie-1, S-1.1, L-1.1, L-1.2, SC/LC

optical interface

IU1, IU2, IU3 and IU5*

Ie-1, S-1.1, L-1.1, L-1.2, SC/LC

optical interface

IU4

Ie-1, S-1.1, L-1.1, L-1.2, SC

optical interface

IU4

Ie-1, S-1.1, L-1.1, L-1.2, SC

Board
Name
OI4
OI4D
OI16D
SB2L

SB2R

SB2D

SLE
SDE
SP1S
SP1D
SP2D
SM1S
SM1D
PD2S
PD2D
PD2T
FP2D
PM2S
PM2D
PM2T
PE3S
PE3D
PE3T
PT3S

Full Name
board
1xSTM-4 optical interface
board
2xSTM-4 optical interface
board
2xSTM-16 optical interface
board
1xSTM-1 single-fiber
bidirectional optical
interface board
1xSTM-1 single-fiber
bidirectional optical
interface board
2xSTM-1 single-fiber
bidirectional optical
interface board
1xSTM-1 electrical interface
board
2xSTM-1 electrical interface
board
4xE1 electrical interface
board
8xE1 electrical interface
board
16xE1 electrical interface
board
4xE1/T1 electrical interface
board
8xE1/T1 electrical interface
board
16xE1 electrical interface
board
32xE1 electrical interface
board
48xE1 electrical interface
board
16xFramed E1 electrical
interface board
16xE1/T1 electrical
interface board
32xE1/T1 electrical
interface board
48xE1/T1 electrical
interface board
1xE3 electrical interface
board
2xE3 electrical interface
board
3xE3 electrical interface
board
1xT3 electrical interface
board

Valid Slot

Description

IU1, IU2, and IU3

Ie-4, S-4.1, L-4.1, L-4.2, SC/LC

IU1, IU2, IU3 and IU5*

Ie-4, S-4.1, L-4.1, L-4.2, SC/LC

IU5*

S-16.1,LC

IU1, IU2, and IU3

S-1.1, L-1.1, SC (Only one left optical


interface is available.)

IU1, IU2, and IU3

S-1.1, L-1.1, SC (Only one right optical


interface is available.)

IU1, IU2, and IU3

S-1.1, L-1.1, SC/LC

IU1, IU2, and IU3

75-ohm E1 interface

IU1, IU2, and IU3

75-ohm E1 interface

IU1, IU2, and IU3

75-ohm/120-ohm E1 interface

IU1, IU2, and IU3

75-ohm/120-ohm E1 interface

IU1, IU2, IU3 and IU6*

75-ohm/120-ohm E1 interface

IU1, IU2, and IU3

IU4

75-ohm/120-ohm E1 interface or 100-ohm


T1 interface
75-ohm/120-ohm E1 interface or 100-ohm
T1 interface
75-ohm/120-ohm E1 interface

IU4

75-ohm/120-ohm E1 interface

IU4

75-ohm/120-ohm E1 interface

IU1, IU2, and IU3

75-ohm/120-ohm Framed E1 interface

IU4

IU1, IU2, and IU3

75-ohm/120-ohm E1 interface or 100-ohm


T1 interface
75-ohm/120-ohm E1 interface or 100-ohm
T1 interface
75-ohm/120-ohm E1 interface or 100-ohm
T1 interface
75-ohm E3 interface

IU1, IU2, and IU3

75-ohm E3 interface

IU1, IU2, and IU3

75-ohm E3 interface

IU1, IU2, and IU3

75-ohm T3 interface

IU1, IU2, and IU3

IU4
IU4

Board
Name
PT3D
PT3T
TDA
SCB

ET1O
EF1
ET1D
EFS
EFT
ET1
EGS
EFSC
ELT2
EGT

AIUD
AIUQ
SHLQ

N64

N64Q
EMU

Full Name

Valid Slot

Description

2xT3 electrical interface


board
3xT3 electrical interface
board
Multi-channel audio and
data access unit
System control board

IU1, IU2, and IU3

75-ohm T3 interface

IU1, IU2, and IU3

75-ohm T3 interface

IU4

12 x audio + 4 x RS232 + 4 x RS422

8-port Ethernet service


electrical interface board
6-port Ethernet service
interface board
2-port Ethernet service
electrical interface board
4-port Ethernet service
electrical interface board
4-port Ethernet service
electrical interface board
8-port Ethernet service
interface board
1-port Gigabit Ethernet
optical interface board
12-port Ethernet service
interface board
2-port Fast Ethernet optical
interface board
1-port Gigabit Ethernet
transparent transmission
board
2xATM optical interface
board
4xATM optical interface
board
Single-pair high-bit-rate
digital subscriber line
interface board
Nx64 kbit/s interface board

IU4

Provides two external clock input


and output interfaces, an NM
interface, an orderwire interface, four
data interfaces, and 4-input and 2output alarm interfaces.

Provides 2xSTM-1 (S-1.1, SC/LC) or


2xSTM-4 (S-4.1, L-4.1, L-4.2, SC/LC) or
2xSTM-16 (S-16.1, LC) optical
interfaces.

Provides 16xE1 (75-ohm/120-ohm)


electrical interface.
10/100BASE-T

IU4

10/100BASE-T, 100BASE-FX

IU1, IU2, and IU3

10/100BASE-T

IU1, IU2, and IU3

10/100BASE-T

IU1, IU2, and IU3

10/100BASE-T

IU4

10/100BASE-T

IU1, IU2, and IU3

1000BASE-LX/SX

IU4

10/100BASE-T

IU1, IU2, and IU3

100BASE-FX

IU1, IU2, and IU3

1000BASE-LX/SX

IU4

Ie-1, S-1.1, MTRJ/LC

IU4

Ie-1, S-1.1, MTRJ/LC

IU1, IU2, and IU3

Provides 4xG.SHDSL data service


interfaces.

IU1, IU2, and IU3

4xNx64 kbit/s interface


board
Environment monitoring
unit

IU1, IU2, and IU3

Provides 2xV.35//V.24/X.21/RS-449/EIA530-compliant interfaces, and 2xFramed


E1 electrical interfaces.
Provides 4xV.35/V,24/X.21/RS-449/EIA-530
interfaces.
Provides two voltage monitoring and
temperature monitoring interfaces, 12input and 6-output alarm interfaces, and

SCB

IU3

Board
Name

FAN
POI/POU

Full Name

Fan board
Power filter board

Valid Slot

FAN
POI/POU

UPM (CAU) Power monitoring unit


External
*: IU5 and IU6 are logical slots of an SCB board.

Description
an RS-232/RS-422 serial communication
interface.
Provides 2x48 V/60 V or 2x24 V power
supplies.
Provides power monitoring.

Specification
Specifications
Aggregation
Dimensions
Switch
Capacity
Service Slots

OptiX155/622H
( also named Metro 1000)
STM-1/STM-4/STM-16
86 mm(H)436mm(W)293mm(D)
TDM: 21.25Gbit/s (136136 VC4, higher order),5Gbit/s (3232
VC4, lower order) Packet: 8Gbit/s
5 slots for processing boards
STM-1/4/16, E1/E3/T1/T3, FE/GE, DDN, ATM,
MSTP interfaces
SHDSL
Framed E1, RS232/RS422, two-wire/fourSupported
wire audio interfaces
PCM interfaces
Interface
V.35/V.24/X.21/RS449/EIA-530/RS-530/RS530A
Packet transport E1 CES, FE/GE
interfaces
DC: -48V DC/-60V DC/+24V DC
Power Supply
AC: 220V/110V AC
Clock
Line clock source
Synchronizatio Tributary clock source
n
Two external clock inputs/outputs (2 MHz or 2 Mbit/s)
Housekeeping signal input/output interface, RS232/RS422
Auxiliary
serial communication interface
Interface
Modem interface, NM interface
Orderwire phone interface
SS42SP2
SS42SP2D

The SS42SP2 is a E1 electrical interface board, The SS42SP2 can be used on Metro 1000 equipment
to transmits and receives E1 electrical signals,
processes VC-12 path overheads, and generates alarm signals on the tributary.
Basic The SP2D processes 16xE1 signals
Functions

Overhead Processes the path overheads at the VC-12 level.


Processing Supports the setting and query of overhead bytes such as the J2
and V5.

Alarms and Provides rich alarms and performance events, thus facilitating the
Performan management and maintenance of the equipment.
ce Events Supports the alarm reversion function.

Protection Supports the SNCP, with a switching time of less than 50 ms.
Schemes

Maintenan Supports inloop and outloop so that faults can be located quickly.
ce Supports the setting of the overhead byte to be sent received, thus
Features enabling the board to function as anoverhead instrument.
Supports the setting of the bit error threshold-crossing values and
degrade thresholds.
Supports the BER test.
Supports the timeslot allocation.
Supports the setting of inserting BIP2 errors.
Supports the lower-order pseudo random binary sequence (PRBS)
function towards the tributary direction and cross-connect direction.

Interfaces

The front panel of the SP2D has the E1 electrical interfaces.


The electrical interfaces are 2 mm HM connectors (4x6 pins). The
digit on an interface indicates the sequence number of the
interface.