MG236,MG236B,MG236C
Product
display
MG236A
Page 1 of 3
Product Specification
Item
Index
Operating Voltage
12VDC+10%; Current 1.2A
Lock Relay
12VDC/2A
Environmental temperature
working:0~45; storage:-10~55
Relative humidity
working:40%~90%RH;storage:-20%~90%RH
RFID Card Capacity
255 cards, a Personal PIN goes alone with each card
4-digits public PIN Capacity
Proximity Reader Frequency
125KHz
Compatible Cards
EM or EM compatible cards
Card Reading Distance
515CM
2. The LED and Buzzer
Status type
Red LED
Green LED
Yellow LED
Normal Working State
on
flash
Buzzer
Authorized Card Read /Valid PIN/Exit
on
on
a short beep
Button Pressed
Wrong PIN Entered
on
flash
a long beep
Non Authorized Card Read
on
flash
a long beep
Acceptable Key Pressed
on
flash
a short beep
Door Sensor, Anti-Break Sensor
on
flash
continuous beeps
Alarmed
Programming Mode
on
on
flash
2 short beeps
Key In Right Programming Instruction on
on
flash
2 short beeps
Key In Wrong Programming Instruction on
on
flash
3 short beeps
3. The Factory Default of the Product
Type
Factory Default
6-digit Programming PIN
990101
Door Open Mode
Authorized Card / Public PIN (Default Public PIN: 1234)
Lock Relay Time
3 seconds
Anti-Break Sensor Alarm
Disabled
Door Sensor Alarm
Disabled
Authorized Card Stored
none
4. Functions and Settings (All functions should be set in programming mode; the parameters can be set repeatedly; the effective setting
should be the last one.)
Enter programming mode:
Press [*]+[6 digits programming PIN],2 beeps;
Under programming state, it should be noted that:
The controller cannot perform normal function instructions.
If there is no programming instruction within 20 seconds, system will automatically quit programming mode and enter the normal
working mode.
Successfully set parameters, 2 beeps;
Fail to set parameters, 3 beeps;
Before some setting instruction is finishedi.e. the controller have already given off 2 beeps for successful setting, or 3 beeps for
failed setting, if the input instruction is mistaken,press [*], the controller gives off a long beep, meaning that the setting of the
instruction has been cancelled.
Change programming PIN:
Press [0]+[6 digits new programming PIN]+[repeat 6 digits new programming PIN], 2 beeps;
Available @ RAM Electronics
27/10/2009
MG236,MG236B,MG236C
Page 2 of 3
Set door open mode:
Card or Public PIN:
Press [1]+[0], 2 beeps;
Card plus Personal PIN;
Press [1]+[1], 2 beeps;
Set Lock Relay Time:
Press [2]+[TT], 2 beeps; TT represents unlocking time, second as unit; if unlocking time is 3 seconds, TT=03;
Set Public PIN:
Press [3]+[4 digits public PIN], 2 beeps;
Press [3]+[0000], 2 beeps, eliminate all public PIN
Set AntiAnti-Break Alarm:
Disable anti-break alarm: press [4]+[0], 2 beeps;
Enable anti-break alarm: press [4]+[1], 2 beeps;
Enrolling Cards:
Press [5]+[4 digits card code], after 2 beeps +[present a card to the controller], a beep, then 2 beeps, then the card was added successfully;
Enrolling more cards, repeat above mentioned operating steps;
1 [4 digits card code]:
code]: a code defined by the customer himself,
himself can be any number between 0000~9999; the code of each card should not
be repeated; the code is also the individual PIN for card plus personal PIN access control mode; if the customer lost the setting card, he
could cancel the card code from the controller, thus, cancel the card from the controllerdetails see how to delete authorized card;
2 After press [5], the controller gives 3 beeps, meaning that the card capacity of the controller is full;
3 After press [5] +[4 digits card code], the controller gives off 3 beeps, meaning that the code is repeated and need a new operation;
4 After press [5]+[ 4 digits card code] 2 beeps +[induce the card to be set before the controller], a beef, then 3 beeps, meaning that the card
number has already been set meanwhile the card code has also been cancelled induce the card to be set before the controller.
Deleting authorized card:
Code mode delete the authorized card: press [6]+[4 digits card code], 2 beeps;
Present the card to delete the authorized card: press [7]+[present the card to the controller], a beep, then 2 beeps;
Deleting multiple cards, repeat above mentioned operation;
Deleting all authorized cards: if the customer needs delete all cards, please restore the controller to factory defaults.
Set door sensor alarm state:
Disable door sensor alarmfunction: press [8]+[0], 2 beeps;
Enable door sensor alarmfunction: press [8]+[1], 2 beeps;
After turning on this function, the controller will give off continuous long beep when the door is not closed after
normal opening, or the door is not opened through the controller;
10.
10.Restore factory defaults:
defaults:
Press [9]+[86], 2 beeps, then 3 long beeps, 3 short beeps after 5 seconds, enter normal working state;
11.
11. Exit programming state:
state:
Press [*], 2 beeps;
Under programming mode, if there is no programming instruction within 20 seconds, the system will automatically quit the programming mode
and enter normal working mode.
5. Users Instructions:
1. Card or public PIN mode:
1Read authorized card: After a short beep, green light is on, yellow light is off and the door is open.
2Public PIN entered: Green light is on, yellow light is off and the door is open;
The customer should continuously type in 4 digits public PIN; the interval between each key pressing should be less than 2 seconds. If the
interval is more than 2 seconds, the system will automatically quit this times PIN input.
3If the customer entered the wrong PIN, press [*], and enter the right PIN again to open the lock.
2. Door opening mode of card + PIN
1Read authorized card, after a beep,
Enter the right 4 digits PIN (code) within 5 seconds, the green light is on and the door is unlocked;
Not enter the PIN within 5 seconds, the buzzer gives off a long beep and the door is not unlocked;
Wrong 4 digits PIN is entered, the buzzer gives off a long beep and the door stays locked; read card again,
enter the right PIN to unlock the door.
Available @ RAM Electronics
27/10/2009
MG236,MG236B,MG236C
Page 3 of 3
Wrong PIN for less than 4 digits, press [*], need not to read card again, directly input the right PIN and unlock
the door;
2Read unauthorized card, the buzzer gives off a beep, then a long beep when pressing the first PIN, and the door stays locked.
6. Installation:
1. Cautions during installation:
1) There should not be 100KHz150 KHz frequency source within 50CM of the controller in the installation;
2) The installation distance between 2 unifying machines, or 1 unifying machine and other 125 KHz card reader should be50CM;
3) When the customer sets Check door sensor when unlocking, the controller checks door sensor open and close state during unlocking;
when the door sensor is separated, the controller regards the door opened already. At this time, except pressing fire control door opening
button, the controller will keep the door locked no matter using any other door opening mode.
2. Installation and line connection:
Must cut off 12VDC power supply during installation and connection. Connecting with electricity is strictly prohibited!!!
7. Force to restore factory defaults:
1. Remove the controller;
2. Use metal tweezer to short connect the J2, the controller gives off a beep, then 2 beeps, and the restored factory default programming PIN
is 990101;
Available @ RAM Electronics
27/10/2009