The EM 5000 is a 5000W FM transmitter consisting of an EM 100DIG exciter and control unit that combines the power of two AM 2500 FM power amplifiers. Each AM 2500 includes eight 350W amplifier modules powered by independent switching power supplies. The equipment includes output filtering and protection systems to monitor parameters and reduce power in unsafe conditions. It provides analog and digital telemetry and remote control capabilities.

Uploaded by

Jesus Perez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
437 views3 pages

OMB EM5000 Katalog

The EM 5000 is a 5000W FM transmitter consisting of an EM 100DIG exciter and control unit that combines the power of two AM 2500 FM power amplifiers. Each AM 2500 includes eight 350W amplifier modules powered by independent switching power supplies. The equipment includes output filtering and protection systems to monitor parameters and reduce power in unsafe conditions. It provides analog and digital telemetry and remote control capabilities.

Uploaded by

Jesus Perez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

EM 5000 SOLID STATE

EM 5000 is a 5000 W FM transmitter made up of


the EM 100DIG exciter and a control unit which
combines the power of two AM 2500 FM
amplifiers.
The 100W FM exciter/modulator, EM 100 DIG, is
controlled by microprocessor, that allow a lot of
applications like power level control at night to
save energy, and the whole monitoring and
adjusting of several parameters of the
equipment, like input level and deviation.
Each AM 2500 includes eight 350W highefficiency
MOSFET technology amplifying
modules, fed by 2 independent switching power
supplies, which are made to withstand the
working conditions. The amplifiying modules
works independently thanks to a power
combining structure that provides high isolation
between them.
The equipment includes a low-pass filter at the
antenna output, EMI filters at the utility
connection and an internal transient suppressor.
The LCD display shows the amplifier main
www.pemancar-fm.com
parameters: supply voltages, 8 module currents,
direct, reflected and input power, power loss in
the internal unbalance load and three temperature sensors. The amplifier control system stores
in their memory all events and alarms detected, showing time and date of occurrence.
Smart temperature protection: if temperature rises up to a level dangerous for the modules, the
output power is reduced until the temperature goes back to a normal state. If, even with the
power reduction, the temperature keeps on rising, then the amplifier is stopped until the
temperature goes down.
Reflected power protection (load mismatch): when the control system detects that the V.S.W.R.
is dangerous for the modules, it reduces automatically their output power so as not to exceed
the internal security level. Besides, there is a fast protection system that instantaneously turns
off the modules polarization when it detects a peak on the reflected power sensor.
Automatic gain control: it reduces the gain in the case of excessive driving power, keeping the
adjusted output power despite temperature changes. The control allows manual power
adjustment by means of the front keyboard.
Telemetry systems: analogue telemetry (direct and reflected power measure), digital
RS-232 telemetry and remote control, remote control through open-close contacts and a
multi-device bus connection for internal use

TECHNICAL FEATURES OF THE EM 5000


EM 100 DIG
AUDIO
S/N RATIO (30 ~ 20000HZ) Mono: 78dB (86dB typical)
Stereo: 72dB (77dB typical)
WEIGHTED S/N (CCIR)
Mono: 75dB (81dB typical)
Stereo: 68dB (72dB typical)
T.H.D. DISTORTION
(LIMITING THRESHOLD ADJUSTED AT 150KHZ DEVIATION)
75 KHZ DEVIATION <0.05% (typical 0.02%)
150 KHZ DEVIATION <0.2% (typical 0.05%)
STEREO CHANNELS CROSSTALK (L / R <-50dB (with external encoder)
< -60dB with internal encoder (100 ~ 5000Hz)
< -50dB with internal encoder (30 ~ 15000Hz)
AUDIO INPUT FREQUENCY RESPONSE
30 HZ ~ 15 KHZ (PASS BAND) 0.1dB
F >19 KHZ (REJECTED BAND) >50dB
STEREO INPUT (MPX) FREQUENCY RESPONSE
0.1dB (10Hz ~ 100KHz)
AUX INPUT (SCA/RDS) FREQUENCY RESPONSE
0.2 dB (10KHz ~ 100KHz)
INPUT LEVELS
AUDIO AND MPX (AT 75 KHZ DEVIATION) -3.5 ~ +12.5dBm adj.
SCA/RDS (AT 7.5 KHZ DEVIATION)
-12 ~ +3.5dBm adj.
SCA/RDS (AT 2 KHZ DEVIATION)
-24 ~ -8dBm adj.
IMPUT IMPEDANCE
AUDIO AND MPX
10K balanced or 600 unbalanced (selectable)
AUXILIAR SCA/RDS
10K
CONNECTORS
AUDIO
XLR Female
MPX, AUXILIAR (SCA/RDS)
BNC Female
COMMON MODE INPUT REJECTION (20 TO
15000HZ) >50dB (>60 dB typical)
MPX OUTPUT LEVEL
0 ~ +10dBm (for 75KHz deviation)
DEVIATION LIMIT
0 ~ +7dBm adj.
PRE-EMPHASIS TIME CONSTANT 50 or 75s 2%
MODULATION
FREQUENCY RANGE
87.5 ~ 108MHz
MODULATION MODE
FM (75KHz peak deviation)
MODULATION CLASS F3E, F8E
CARRIER FREQUENCY TUNING STEPS 10 / 100KHz
FREQUENCY OFFSET
<200Hz
FREQUENCY DRIFT
Thermal <250Hz from -10? To 45?C
Stability <100Hz / year
RF OUTPUT POWER
MAX. REFLECTED POWER ALLOWED
HARMONICS
SPURIOUS
OUTPUT IMPEDANCE
CONTROL AND PROTECTION

www.pemancar-fm.com

RF
0 ~ 100WRMS adj.
10W
<-70dBc
<-80dBc (-95dBc typical)
50 (N Female Connector)
- Protection against spurious emissions
- Reflected power protection
- Power level automatic reduction at night

GENERAL FEATURES
AC POWER SUPPLY 90 ~ 260VAC, 50/60Hz
POWER CONSUMPTION 180VA (100 W RF)
TEMPERATURE RANGE -10 ~ 45C
CONTROL SIGNALS RF enable
RF output power indication
ON AIR
Failure indication
RS-232
DIMENSIONS 3RU (19 rack)
438 x 132 x 334mm without handles
WEIGHT 11Kg (24.2Lbs)

AM 5000
FREQUENCY RANGE
OPERATION CLASS
INPUT RETURN LOSS
INPUT POWER
OUTPUT POWER
TYPICAL RF EFFICIENCY
COOLING
HARMONICS LEVEL
INPUT / OUTPUT IMPEDANCE
RF INPUT CONNECTOR
RF OUTPUT CONNECTOR
RF MONITOR CONNECTOR
SUPPLY

CONSUMPTION
PROTECTIONS

TELEMETRY AND REMOTE CONTROL

WORKING TEMPERATURE
DIMENSIONS

87.5 ~ 108MHz
B
<-20dB
70 ~ 90W
5000W nominal, manual and automatic adjustment
70%
Forced air
<83dBc
50
N female
EIA 1-5/8
BNC female
-Three-phase 380Vac + Neutral; 220Vac 10% 50/60Hz
- Three-phase triangle 220Vac without neutral 10%
50/60Hz
<10000W, typ. 8792,69W
-Reflected, Forward power, overdrive, overcurrent In
each 2000W module:
-Smart Temperature protection
-Reflected power protection (load mismatch):
PRFL automatic control + Fast protection
-Automatic Gain Control
-Real-time events register
-Exciter inhibition
-Analog telemetry (direct and reflected power
measurement)
-Telemetry and RS-232 digital remote control
-Remote control by open / closed contacts
-Multi-device bus
-5 to +40C
25RU standard 19

GENERAL FEATURES OF THE EM 5000


DIMENSIONS
WEIGHT
MAXIMUM HEIGHT OF OPERATING
CONSUMPTION
POWER SUPPLY
OPERATING HUMIDITY
OPERATING TEMPERATURE
MAX. OUTPUT POWER

www.pemancar-fm.com

1 standard rack of 19 and 25U


~246Kg
4500m standard ( with overpressurization 6000m)
<12000W, typ. 10000W
380V three-phase, 10%
95%
-5C - +40C
5000W