DWG
PART
QTY
REF
NUMBER
Dash
L
P
S
Length IN(MM) IN(MM) IN(MM)
DESCRIPTION
MATERIAL
-1
59.15
(1502)
47
(1194)
23X1
(588)
Filament Wound Epoxy/Glass
composites - Head locking grooves
integrally wound in place.
-2
99.15
(2518)
87
(2210)
56X1
(1422)
(31)
CF3M *
-3
139.15
(3534)
127
(3226)
80X1
(2032)
(37)
-4
179.15
(4550)
167
(4242)
64X2
(1626)
(43)
-5
219.15
(5566)
207
(5258)
78X2
(1981)
106
-6
259.15
(6582)
247
(6274)
92X2
(2337)
119
-7
299.15
(7598)
287
(7290)
106X2
(2692)
130
-8
339.15
(8614)
327
(8306)
120X2
(3048)
142
SHELL
1
2
3
SHELL
ORDER
A/R SECTION
A/R
F/C Port
F/C Port Seal
Ethylene Propylene .
HEAD - NON CODED
4
96243
96000
Elliptical Head Assy. Engineering Thermoplastic.
Head Seal
Ethylene Propylene - O - Ring
HEAD INTERLOCK
6
47336
Approx
Weight
LB(KG)**
56
Quick Release Spiral
316 Stainless Steel.
Ring
VESSEL SUPPORT
2+
52169
Saddle
2+
45042
Strap Assy.
304 Stainless Steel-PVC Cushion.
46265
Strap screw.
5/16-18 UNC, 18-8 Stainless Steel.
Engineering Thermoplastic.
ELEMENT INTERFACE
10
A/R
Adapter
Engineering Thermoplastic.
11
52245
Adapter seal
Ethylene Propylene - O - Ring
12
A/R
PWT Seal
Ethylene Propylene - O - Ring
13
97014
Thrust Cone
Engineering Thermoplastic.
+ 3 each furnished with length code 4,5,6,7 & 8.
(25)
69
81
94
(48)
(54)
(59)
(64)
RATING:
DESIGN PRESSURE...300 PSIG at 190F
(2.1 MPa at 88C)
MIN. OPERATING TEMP.........20F
(-7C)
FACTORY TEST PRESSURE...450 PSIG
(3.1 MPa)
QUALIFICATION PRESSURE .....1800 PSI
(12.4 MPa)
INTENDED USE:
The CodeLine 80S30 Non Coded Fiberglass RO Pressure
Vessel is designed for continuous, long term use as a
housing for reverse osmosis membrane elements to desalt
typical brackish waters at pressures up to 300 psi. Any
make of eight-inch nominal diameter spiral-wound
element is easily accommodated; the appropriate
interfacing hardware for the element specified is
furnished with the vessel.
The Shell of CodeLine 80S30 Non Coded vessel is
designed in accordance with the engineering standards of
the Boiler and Pressure Vessel Code of the American
Society of Mechanical Engineers (ASME) as per Section
X.
The CodeLine 80S30 Non Coded vessel must be installed
operated and maintained in accordance with the listed
precautions and good industrial practice to assure safe
operation over a long service life.
The high performance Filament wound FRP shell must be
allowed to expand under pressure; undue restraint at
support points or piping connections can cause leaks to
develop in the shell. This side-ported vessel requires
special precautions in mounting and connection to piping
so that the vessel will not be subjected to excessive stress
due to bending moments acting at the side openings in the
fiberglass shell. The end closure, incorporating close
fitting, interlocking metal components, must be kept dry
and free of corrosion; deterioration can lead to
catastrophic mechanical failure of the head.
Pentair will assist the purchaser in determining the
suitability of this standard vessel for their specific
operating conditions. The final determination however,
including evaluation of the standard material of
construction for compatibility with the specific corrosive
environment, shall be the responsibility of the purchaser.
Alternate materials with enhanced corrosion resistance are
available on special order.
PRECAUTIONS:
DOread, understand and follow all instructions; failure to
take every precaution will void warranty and may result in
vessel failure
DOmount the shell on horizontal members at span S
using compliant vessel supports furnished; Shim saddles if
required. Tighten hold down straps just snug
DOalign and center side ports with the manifold header.
Correct, causes of misalignment in a row of vessels
connected to the same header
DOuse flexible type IPS grooved-end pipe couplings, at
side ports; allow full, 0.125 inch gap between port and
piping, and position piping to maximize flexibility of
connection.
DOprovide flexibility in, and support for piping manifolds
so that vessel can grow in length under pressure without
undue restraint; provide additional flexible joints in large
pipes leading to manifold header.
DOprovide overpressure protection for vessel set at not
more than 105% of design pressure
DOinspect end closures regularly; replace components that
have deteriorated and correct causes of corrosion
DO Lubricate seals sparingly, using nonpetroleum
Based lubricants, i.e. Parker Super O-lube,
Glycerin or suitable silicone based lubricants.
DO NOTwork on any component until first verifying that
pressure is relieved from vessel
DO NOTmake rigid piping connections to ports or clamp
vessel in any way that resists growth of fiberglass shell
under pressure;
***DIA = 0.015 in. (0.4mm) and
***L = 0.2 in. (6mm) for a length code 8 vessel
DO NOT hang piping manifolds from ports or use vessel in
any way to support other components
DO NOTtighten Permeate Port connection more than one
turn past hand tight
DO NOT operate vessel without connecting both Permeate
Ports internally to complete set of elements or otherwise
plug ports internally so that external piping connection is
not subjected to feed pressure
DO NOTinstall Spacer on downstream end of vessel
DO NOToperate vessel without Thrust Cone installed
downstream
DO NOTpressurize vessel until double-checking to verify
that the Locking Ring is in place and fully seated.
DO NOToperate vessel at pressure and temperature in
excess of its rating.
DO NOToperate vessel with permeate pressure in excess of
125 psi at 190F (0.86 Mpa at 880 C).
DO NOTtolerate leaks or allow end closures to be routinely
wetted in any way
DO NOToperate outside the pH range 3-11.
ORDERING:
Using the chart below, please check the features you require
VESSEL LENGTH CODE please check one
MODEL 80S30 Non Coded -1 -2 -3 -4 -5 -6 -7 -8
MEMBRANE BRAND AND MODEL
Please supply adapters for the following membrane brand and specific model
Brand_________________________ Model_______________________
CERTIFICATION REQUIRED
CE Marked Standard.
Certified by Pentair.
ADAPTER KITS
UP
STREAM
DOWN
STREAM
PERMEATE PORT CONFIGURATION:
Standard. 1 FNPT & 1.5 IPS GROOVED NORYL HEAD.
Optional .1 BSP F/JIS F Parallel Thread & 1.5 IPS GROOVED NORYL HEAD.
STRAP ASSEMBLY
Standard SS304
Optional SS316
Optional SS316L
FEED/CONCENTRATE PORT SELECTION
Material of Construction Standard CF3M Optional Duplex SS (CD3MN)
Optional Super Duplex SS (CD3MWCuN)
Configuration
Standard - CF3M 1D5D
Optional Multi ports :( Refer SPEC.SHEET/PM/1.5-3for Multi port selection)
Serial number end
Opposite end
PORT SIZE CODE
D
1 GROOVED END
2 GROOVED END
2 GROOVED END
Specifications are subject to change without notice.
For complete information on proper use of the vessel
Please refer to the 80S Series USERS GUIDE 94182.
DWG. NO. 99172-N,
Pentair
PAGE 2 OF 2.
CODELINE BODY LABELS ARE PLACED AT
90 TO SERIAL NUMBER END AND AT 270
ON THE OPPOSITE SIDE END