OPC Server Help Manual
OPC Server Help Manual
Ver4 .2
Communication Software
Tokyo Branch
TEL +81-45-474-3259
TEL +81-55-206-1075
Nagoya Branch
TEL +81-52-454-3721
Shiga Branch
TEL +81-749-23-0654
Ritto Branch
TEL +81-77-553-0115
Osaka Branch
TEL +81-6-6341-5081
Kihoku Branch
TEL +81-773-23-9191
Kyushu Branch
TEL +81-75-325-2172
TEL +81-92-473-7580
[GLOBAL]
Takebishi Electric Sales Shanghai Limited
RoomE 27/F., HuaDu Building 838 ZhangYang Road, Pudong NewArea, Shanghai 200122
TEL +86-21-6875-6680
TEL +86-22-8319-5220
Support Dial
Available:
+81-75-325-2261
Weekday 9:00-17:00
TEL +852-2506-1857
Online Shop :
www.faweb.net
TAKEBISHI Corporation
* All of the above products and any other trademark are under
the trade mark of their respective manufactures.
* The contents will be changed without notice in the future.
Jun. 2010
Whats OPC
Interface specification for communicating with applications
OPC (Ole for Process Control) is standard interface specification for communic a t i o n b e t we e n a p p l i c a t i o n s i n m a n u f a c t u r i n g i n d u s t r y s y s t e m . O P C h a s a n a r c h i t e c t u r e o f s e r v e r a n d c l i e n t t y p e . O P C S e r v e r c o m m u n i c a t e s wi t h f i e l d d e vices such as PLC. OPC Client provides various functions basing on data of
equipments acquired from OPC Server. The OPC define these interface specific a t i o n s . Y o u wi l l r e d u c e t h e c o s t o f d e p e n d e n c e b e t we e n a p r o d u c t i o n l i n e a n d
IT system by developing OPC system.
OPC Client
OPC Server
O PC
Equipment
...
OPC has various interface such as OPC DA for real time communication, OPC
HDA for historical data access, OPC AE for Alarm & Event. The specification of
O P C i s s t a n d a r d i z e d b y O P C f o u n d a t i o n . M i t s u b i s h i , O m r o n , Y o k o g a wa , R o c k we l l , a n d S i e m e n s , e t c m o r e t h a n 3 5 0 J a p a n e s e , A m e r i c a n a n d E u r o p e a n P L C
v e n d o r s a n d s o f t wa r e p a c k a g e v e n d o r s p a r t i c i p a t e i n i t .
Whats DeviceXPlorer
OPC Server providing abundant connectivity
D e v i c e X P l o r e r i s a O P C S e r v e r t h a t c o m m u n i c a t e s wi t h a l l k i n d s o f f i e l d s d e v i c e s s u c h a s P L C a n d m e a s u r i n g i n s t r u m e n t s . D e v i c e X P l o r e r c o r r e s p o n d s wi t h
a l l s p e c i f i c a t i o n o f O P C D A , E t h e r n e t , S e r i a l a n d o r i g i n a l n e t wo r k s , s o t h a t i t
c a n b e u s e f u l i n a n y s c e n e s i n o p e r a t i n g f a c t o r y.
O PC C l ien t
ERP/MES
SCADA
DCS
Visual Basic
Visual C/C++
VB.NET
C#.NET
EXCEL
VBA
VSTO
OPC Interface
DeviceXPlorer
OPC Server
DeviceXPlorer which utilizes its benefit to the full and connects the
Ethernet/RS232C
Feature
Features
Connectivity - Multiple PLC
Multiple Language
SYSMAC
TOYOPUC
ControlLogix
You will switch locale to keep communication by only selecting the target language on Option dialog of Tool
menu. So you can select suitable user interface for any
engineer operating OPC Server. It supports Japanese,
English, Chinese (Simplified Chinese.)
Custom Application
OPC Server
OPC
SYSMAC
Memory
MELSEC
OPC DA 3.0
Shared Memory
SCADA
OPC
SIMATIC-S7
TOYOPUC
.
.
.
It used each kinds of OPC Server when there were some
kinds of PLC in the factory. DeviceXPlorer DXP2007 series integrated all existing products and communicate with
multiple PLCs. So, OPC client only access single namespace and then it can access all PLCs.
SCADA Ready
Compatible with all of SCADA
(Windows language pack is required)
Redundant communication
Static tag and Dynamic tag
Standardization by using alias name
DeviceXPlorer supports Static tag and Dynamic tag. Tags
that are defined in advance are called "Static tag" and
tags that are not defined in advance are called "Dynamic
tags." Using Static tag allows client to access PLC without caring physical devices.
Even if PLC vendor has
changed, system can be reorganized without physical tags
name. So, flexible system can be built with benefit of
OPC. Dynamic tags access physical address of PLC directly, so that engineers can save time to specify tags.
Configuration file A
Speed
Temp
Speed
Temp
D0
D1
DM10
DM11
D0
D1
DM10
DM11
GE Intelligent Platforms
Cimplicity, iFix
Rockwell Automation
RSView
Siemens
WinCC
ICONICS
Genesis, GraphWorX
National Instruments
LabVIEW
Citect
CitectSCADA
JT Engineering
JoyWatcher
Yamatake (azbil)
Yokogawa
ASTMAC, ExaPilot
Break
Switch
Configuration file B
Wonderware
RAS diagnosis
Temp
Product
DeviceXPlorer can diagnose status of connections, configured parameter, and tag information and so on for each
OPC interface, DDE/SuiteLink interface. RAS diagnosis
enables to trace easily of source of unexpected troubles
and it shortens the down time.
AB ControlLogix
Siemens S7-1200
MELSEC-L
Communication performance
Speed
on
PLC B
Field Devices
MITSUBISHI MELSEC
OMRON SYSMAC
MELSEC-L
MELSEC-Q is main
series. It has Universal Model, Redundant CPU, Process CPU and more.
MELSEC-L series is
popular model attached Motion, DIO
and field network.
MELSEC-FX
MELSEC-FX series
is used as a sensor
controller in small
system.
MELSEC-A
MELSEC-QnA
MELSEC-QnA series
looks like A series
on the outside, but
software
architecture is Q series.
SYSMAC-CJ2
FinsGateway 2003
MELSEC-A series is
discontinued
lines
but it is still working in many plants.
SYSMAC-CJ2
SYSMAC-CP
SYSMAC-CS
FINS Network
Transient Communication
DeviceXPlorer supports to access to target station on
MELECNET/H or CC-Link/IE through Ethernet connecting
station.
FINS/TCP Communication
You can use FINS/TCP protocol for CJ. DeviceXPlorer
communicate with node number published from SYSMAC
at established connection.
JTEKT TOYOPUC
Random Access Buffer
Multiple CPU and Redundant CPU
You will access to each device memory in Multiple CPU
System. And you can build system smoothly so CPU refresh parameter setting is not required. Also, DeviceXPlorer supports to access the data with specifying Control/Standby in redundancy system.
TOYOPUC-PC10 Series
DeviceXPlorer supports small programmable controller called PC10 series which has
high speed calculation CPU, large memory
and many communicative useful functions.
Field Devices
YOKOGAWA FA-M3
Buffer Access Memory
You can access to buffer memory in the special module
(analog input/output, temperature control, or PID control
etc...) by designating unit number and slot number of target module. Please use an Ethernet module on and after
version Rev.03.00, when you access to the buffer memory
(a special module data.)
FUJI MICREX
FA-M3 Unsynchronized Command
When you use F3LE01-5T, you can use the unsynchronized command which is not affected scan time. The
command make it possible to get 502 points as the register value (normally: 251 points) at a once.
(Data synchronism is guaranteed by 16 bit.)
MICREX-SX
HITACHI HIDIC
Task Code Version 5
DeviceXPlorer supports the HIDIC Task Code communication version5, so you can access efficiently to enhance
CPU such as EH150 series, H-4010 Series. It supports a
binary code communication with TCP/IP and UDP/IP.
MICREX-F
PANASONIC FP
LUMP Address
You can access to other station through CPU link by designating a LUMP address (loop number, unit number,
module number and port number.)
SHARP SATELLITE
Support for Satellite Net
Layer Access
With using FP2/FP2SH series, you can access the layer
network by designating a station address of gateway.
YASUKAWA MP
Type of Bit and Byte and Word
You can access some devices of Bit type, byte type, and
word type.
Expanded MEMOBUS
The Ethernet module of MP2000 series is available to use
the expanded MEMOBUS command. It is expanded access point of batch reading/write commands and supports
random write command to retention register. You will get
more high speed communication by using the expanded
MEMOBUS command.
Field Devices
KEYENCE KV
KV-5000 & KV-LE20V
You can access to internal Ethernet port of KV-5000 Series. DeviceXPlorer supports ASCII code on computer link
command, and you will select TCP/IP and UDP/IP. You
can communicate with high performance so KV-LE20V is
expanded to a maximum of 1000 words per request.
FANUC PMC
Full-supported Devices
DeviceXPlorer supports all of KV devices such as data
memory, control memory, and expanded memory etc.
FOCAS1 / FOCAS2
You can get PMC data by using FOCAS1 or FOCAS2 for
designated IP address and port number.
ROCKWELL AB
Symbolic Segment
You can define symbolic segment of global tag as OPC
Item. For example, the tag defined Struct1.Bool1 in ControlLogix is accessed item ID as Device1.Struct1.Bool1.
MODBUS
EtherNet/IP(CIP Service)
You can access to the CPU
supported EtherNet/IP by designated
CIP
port
number
(backplane is fixed to "1") and
CIP link address.
MODBUS/TCP
DeviceXPlorer supports Ethernet communication (MODBUS/
TCP) and Serial communication (MODBUS/ASCII, MODBUS/RTU). It is available to swap in the case of LONG,
LONGLONG, FLOAT, and DOUBLE.
SIEMENS SIMATIC-S7
S7 Protocol
You can access to Ethernet module of S7-300 Series and
S7-400 Series because DeviceXPlorer supports S7 protocol (TCP/IP).
Also DeviceXPlorer supports to access
internal Ethernet port of latest Series called S7-1200.
OPCDA
Unnecessary CP Card
It is not necessary CP card and SIMATIC NET library on
the PC. OPC Server communicate with PLC via native
Ethernet.
Synchronous / Asynchronous
DeviceXPlorer supports 4 interfaces in the case of
reading from OPC Server, such as Synchronous Read
(device/cache read), Asynchronous Read, Advise, and
Item I/O Read.
10
Specification
Module List
Vendor
Series
MELSEC-Q
MITSUBISHI
FX3U-ENET(-L)
FXxx-232-BD
FXxx-485-BD
FXxx-232ADP
FXxx-485ADP
CPU Serial port
MELSEC-QnA
Q4A(R)
Q3A
Q2A(S/SH)(-S1)
A(1S)J71QE71(N)-T
A(1S)J71QE71(N)-B2
A(1S)J71QE71(N)-B5
AJ71QC24(N)(-R2/-R4)
A1SJ71QC24(N)(-R2)
CPU Serial port
MELSEC-A
A4U
A3(N/A/U)
A2(N/A/U)(S/SH)(-S1)
A1(N)(S/SH)
AJ71E71(-S3)
A(1S)J71E71(N)-T
A(1S)J71E71(N)-B2
A(1S)J71E71(N)-B5
AJ71UC24 *2
AJ71C24-S8
A1SJ71UC24
CPU Serial port
SYSMAC-CJ
CJ2H
CJ1G
CJ1H
CJ1M
CJ1W -ETN11/21
CJ1W -EIP21 *3
CPU Ethernet port
CJ1W -SCU42/32/22
CJ1W -SCU41/31(-V1)
CJ1W -SCU21(-V1)
CPU Serial port
CS1G
CS1H
CS1D
CS1W -ETN21/11/01
CS1W -EIP21 *3
CS1D-ETN21D
CS1W -SCU31/21(-V1)
CS1W -SCB41/21(-V1)
CPU Serial port
SYSMAC-CP
CP1E
CP1L
CP1H
CP1W -ClF41
CJ1W -ETN21
CJ1W -EIP21 *3
CP1W -CIF12/11/01
CJ1W -SCU41/31(-V1)
CJ1W -SCU21(-V1)
SYSMAC-CV
CVM1(D)
CV2000
CV1000
CV500
MELSEC-FX
CV500-LK201
CPU Serial port
Q81BD-J71LP21-25
Q81BD-J61BT11
Q80BD-J71GP21(S)-SX
Q80BD-J71LP21(S)-25
Q80BD-J71LP21G
Q80BD-J71BR11
Q80BD-J61BT11N
GX-Simulator *1
Series
CPU
DXPSTL-U
JW -255CM
JW -25TCM
JW -51CM
J-Board
Z-300
Z-500
Z339J
MICREX-SX
SPH3000
SPH300
SPH300EX
SPH2000
SPH200
NP1L-ET1
NP1L-ET2
CPU Ethernet port
NP1L-RS1
NP1L-RS2
NP1L-RS3
NP1L-RS4
NP1L-RS5
MICREX-F
F150S
F140S
F120S
F120H
F80H
F70
F55
FFU170B
NC1L-ET1
FFU120B
NC1L-RS2
NC1L-RS4
NV1L-RS2
FP-X
FP-X C60R/T/P(D)
FP-X C30R/T/P(D)
FP-X C14R/T/P(D)
FP-X COM5
FP2
FP2
FP2SH
FP2 ET-LAN
MP2000
MP2400
MP2310
MP2300(S)
MP2200
218IF-01
218IF-02
CPU Ethernet port
MP900
MP920
218IFA
KV
KV-5000
KV-3000
KV-1000
KV-700
KV-LE20V
KV-LE20A
KV-LE20
AB ControlLogix
1756
1756-ENBT
AB CompactLogix
1769-L35E
1769-L32E
1768
1768-ENBT
CPU Ethernet port
AB FlexLogix
1794
1788-ENBT
AB DriveLogix
5730/5720
1788-ENBT
SIMATIC-S7
S7-1200
S7-400
S7-300
CP443-1
CP343-1
CPU Ethernet port
FANUC PMC
320i
310i
300i
210
160i-L
160i-W ,180i-W
160i-P,180i-P
160i-B,180i-B,210i-B
160i-A,180i-A,210i-A
160
180
150i
150
0i-A
0i-B
PMi-H
PMi-D
MODBUS
MODBUS/TCP
DXPMDB-U
MODBUS devices
HIOKI 2300 SmartSite
M-SYSTEM R3 Series etc
DXPOPC-U
(OPC DA Server)
PANASONIC
SYSMAC-C
SYSMAC-One NSJ
NSJ
NSJW -ETN21
CPU Ethernet port
TOYOPUC-PC10
PC10G
PC10GE
EN-I/F(-T)
FL/ET-net-5
FL/ET-T-V2(H)
CPU Ethernet port
TOYOPUC-PC3J
PC3J(L/D/M/NM/NF)
MULTI-GW
EN-I/F(-T)
FL/ET-net-5
FL/ET-T-V2(H)
TOYOPUC-PC2J
PC2J(C/S/R)
PC2J16(R/H/PR/HR)
EN-I/F(-T)
FL/ET-net-5
FL/ET-T-V2(H)
FA-M3(R)
F3SP67-6S
F3SP66-4S
F3SP59-7S
F3SP58-6H/S
F3SP53-4H/S
F3SP38-6N/S
F3SP35-5N
F3SP28-3S/N
F3SP25-2N
F3SP21-0N
F3SP08-0P
F3SP05-0P
F3LE12-0T
F3LE11-0T
F3LE01-5T
HIDIC EH150-EHV
EHV-CPU128/64/32/16
EH-ETH
HIDIC EH150
EH-CPU548/516/316A
EH-CPU208A/104A
EH-ETH
HIDIC-H
H-4010
H-2002
H-1002
H-702
H-302
H-252
LAN-ETH(2)
*6
YASUKAW A
DXPYMP-U
*4
KEYENCE
DXPKKV-U
ROCKW ELL
*7
DXPALB-U
SIEMENS
DXPSMT-U
FANUC
*8
DXPGFC-U
(General)
F3LC12-1F
F3LC11-2F/1F
F3LC11-2N/1N
OPCDA
(Shared Memory)
*1
*2
*3
*4
*5
*6
*7
*8
*9
Serial
JW 300
JW 100H
JW 70H
JW 50H
JW 30H/20H
DXPMRX-U
DXPPFP-U
Ethernet
SATELLITE-JW
SHARP
C500-LK203/201
C500-LK103/101
C200-LK202/201/101
C120-LK202/201/101
CPU Serial port
C200H
CQM1(H)
CPM1/2
C2000H/C1000H
HITACHI
11
CV500-ETN01
Vendor
Others
FUJI
FX3U(C)
FX3G
FX2N(C)
FX1(S/N/NC)
FX0(S/N)
DXPFAM-U
DXPHID-U
QJ71C24N
QJ71C24N-R2
QJ71C24N-R4
CPU USB port
CPU Serial port
DXPTYP-U
YOKOGAW A
Q170M
MELSEC-L
OMRON
*5
QJ71E71-100
QJ71E71-B2
QJ71E71-B5
CPU Ethernet port
Serial
LJ71C24
LJ71C24-R2
CPU USB port
SYSMAC-CS
JTEKT
Ethernet
Q26UD(E)H
Q25(H/PH/PRH)
Q20UD(E)H
Q13UD(E)H
Q12(H/PH/PRH)
Q10UD(E)H
Q06(H/PH/UDH/UDEH)
Q04UD(E)H
Q03UD(E)
Q02(U/H/PH)
Q01(U)
Q00(U)(J)
L26CPU-BT
L02CPU
DXPMEL-U
DXPSYS-U
CPU
(ALL)
*9
Others
MODBUS/RTU
MODBUS/ASCII
OPC DA2.05A/3.0
Unsupported GX-Simulator2.
Support communication protocol of MELSEC-A Series as type1 and type4.
Support Fins protocol. Unsupported EtherNet/IP communication.
FinsGateway is required for Controller Link communication. For Ethernet and Serial communication, FinsGateway is not required.
JTEKT communication library(TJA-2067) is required for CPU internal port communication.
Support Expended MEMOBUS protocol.
Support EtherNet/IP (CIP service) communication.
FUNUC FOCAS1 or FOCAS2 are required.
Available to connect to SCADA or third partys OPC Server through OPC DA interface.
12
Lineup
Price List
Performance specification
Item
OS
*1
Description
W indows 7/Vista/2008/2003/XP/2000
*2
Application type
Hard disk
100MB or more (MELSEC EZSocket and SYSMAC FinsGateway communications require more than
200MB)
*1
Model
I/F
Support PLC
ETN
RS2
etc
DXPMEL-U
DXPSYS-U
DXPTYP-U
DXPFAM-U
*2
*3
Memory
1GB or more
License
DXPHID-U
Protection
DXPSTL-U
DXPMRX-U
DXPPFP-U
DXPYMP-U
Possible
DXPKKV-U
KEYENCE KV Series
256
DXPALB-U
Maximum Tags
Unrestricted
DXPSMT-U
Protocols
DXPGFC-U
Possible
DXPMDB-U
MODBUS/TCPMODBUS/RTUMODBUS/ASCII
Development Language
Threading Model
W indows Service Activation
*3
Maximum PLCs
Simulation Mode
Extended Format
*1
*2
*3
13
*4
USD 680
DXPOPC-U
Takebishi.Dxp.1
DXP-L10-U
*6
USD 5,800
Possible
DXP-V-U
*6
USD 340
OPC Item ID
ETN
RS2
etc
Data type
*4
*4
PROG.ID
OPC
DDE/SuiteLink
*4
Price
VT_BOOL
(Logical values)
VT_BOOL | VT_ARRAY
VT_I1
VT_I1 | VT_ARRAY
VT_UI1
VT_UI1 | VT_ARRAY
VT_I2
VT_I2 | VT_ARRAY
VT_UI2
VT_UI2 | VT_ARRAY
VT_I4
VT_I4 | VT_ARRAY
VT_UI4
VT_UI4 | VT_ARRAY
DXPENT-U
USD 1,280
DXPENT-M3-U
USD 1,980
DXPENT-M5-U
USD 2,980
DXPENT-L10-U
USD 11,000
DXPENT-V-U
USD 640
DXPENT-CHG-U
USD 640
ETN
RS2
etc
VT_R4 | VT_ARRAY
VT_I8 | VT_ARRAY
VT_UI8
VT_UI8 | VT_ARRAY
VT_R8
VT_R8 | VT_ARRAY
VT_BSTR
(Character string)
VT_BSTR | VT_ARRAY
VT_ARRAY
(Array)
*2 *3 *4
Price
Topic Name
I/F
Support PLC
VT_I8
*1
Model
VT_R4
Application Name
*5
OPC DA2.05A/3.0
*5
*5
Option
I/F
Product
Boolean
*1
*1
*1
*2
BCD
*3
*4
*5
*6
Character string
Array
Read-only
Write-only
Model
DXPFGW -U
Support PLC
For DXP SYSMAC OPC Server or Enterprise
license
License Pack
The license pack (DXP-L10-U) includes with a install media and 10 licenses.
Please mentioned that you do not upgrade for each other.
Price
USD 290
14