0% found this document useful (0 votes)
679 views8 pages

OPC Server Help Manual

DeviceXPlorer OPC Server is communication software made by Takebishi Corporation that allows applications to connect to industrial field devices. It acts as an OPC server, using standard OPC interfaces to connect client applications to equipment from manufacturers like Mitsubishi, Omron, and others. DeviceXPlorer supports various PLCs and protocols, provides multi-language support, and high-speed tag sharing between clients. It also offers features like redundant communication, diagnostic tools, and compatibility with major SCADA and visualization software.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
679 views8 pages

OPC Server Help Manual

DeviceXPlorer OPC Server is communication software made by Takebishi Corporation that allows applications to connect to industrial field devices. It acts as an OPC server, using standard OPC interfaces to connect client applications to equipment from manufacturers like Mitsubishi, Omron, and others. DeviceXPlorer supports various PLCs and protocols, provides multi-language support, and high-speed tag sharing between clients. It also offers features like redundant communication, diagnostic tools, and compatibility with major SCADA and visualization software.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

DeviceXPlorer OPC Server

DXP2007 Ser ies

Ver4 .2

Communication Software

DeviceXPlorer OPC Server

TA KEB ISHI Corporation


Please contact us.
[J AP AN]
Head Office

29, Mamedacho, Nishikyogoku, Ukyo-ku, Kyoto 615-8501

Tokyo Branch

Shin-Yokohama Kotsu Bldg. 6F 3-18-16,Shin-Yokohama,


Kohokuku, Yokohama 222-0033

TEL +81-45-474-3259

Kofu Sales Office

Nakazawa Bldg. 301 Room, 2-3-23, Sumiyoshi Kofu Yamanashi 400-0851

TEL +81-55-206-1075

Nagoya Branch

Lotus Bldg. 5F, 18-22,Tsubaki-Cho,Nakamura-Ku, Nagoya 453-0015

TEL +81-52-454-3721

Shiga Branch

Shiga Branch 164, Tomachi, Hikone, Shiga 522-0009

TEL +81-749-23-0654

Ritto Branch

9-5-26, Ogaki, Ritto, Shiga 520-3024

TEL +81-77-553-0115

Osaka Branch

Sakurabashi-Chiyoda Bldg. 2F, 2-1-27, Dojima, Kita-ku, Osaka 530-0003

TEL +81-6-6341-5081

Kihoku Branch

2-8, Suehirocho, Fukuchiyama, Kyoto 620-0054

TEL +81-773-23-9191

Kyushu Branch

TEL +81-75-325-2172

Higashi-Hie Square Bldg.4F, 3-12-16, HigashiHie,


Hakataku, Fukuoka 812-0007

TEL +81-92-473-7580

[GLOBAL]
Takebishi Electric Sales Shanghai Limited
RoomE 27/F., HuaDu Building 838 ZhangYang Road, Pudong NewArea, Shanghai 200122

TEL +86-21-6875-6680

Takebishi Electric Sales Shanghai Limited TIANJIN Branch


Room1405, The Exchange Tower2 189 Nanjing Road, Heping District, Tianjin

TEL +86-22-8319-5220

Takebishi Electric Sales Hong Kong Limited


Office No.1, 22/F., 148 Electric Road, North Point, Hong Kong

Support Dial

Available:

+81-75-325-2261

Weekday 9:00-17:00

[email protected]

Japan local time

TEL +852-2506-1857

Online Shop :

www.faweb.net

TAKEBISHI Corporation

* All of the above products and any other trademark are under
the trade mark of their respective manufactures.
* The contents will be changed without notice in the future.

Jun. 2010

http: //w ww.faw eb.net/

Because there is sophisticated scene over there.

Whats OPC
Interface specification for communicating with applications
OPC (Ole for Process Control) is standard interface specification for communic a t i o n b e t we e n a p p l i c a t i o n s i n m a n u f a c t u r i n g i n d u s t r y s y s t e m . O P C h a s a n a r c h i t e c t u r e o f s e r v e r a n d c l i e n t t y p e . O P C S e r v e r c o m m u n i c a t e s wi t h f i e l d d e vices such as PLC. OPC Client provides various functions basing on data of
equipments acquired from OPC Server. The OPC define these interface specific a t i o n s . Y o u wi l l r e d u c e t h e c o s t o f d e p e n d e n c e b e t we e n a p r o d u c t i o n l i n e a n d
IT system by developing OPC system.

OPC Client

OPC Server
O PC

Equipment

...

OPC has various interface such as OPC DA for real time communication, OPC
HDA for historical data access, OPC AE for Alarm & Event. The specification of
O P C i s s t a n d a r d i z e d b y O P C f o u n d a t i o n . M i t s u b i s h i , O m r o n , Y o k o g a wa , R o c k we l l , a n d S i e m e n s , e t c m o r e t h a n 3 5 0 J a p a n e s e , A m e r i c a n a n d E u r o p e a n P L C
v e n d o r s a n d s o f t wa r e p a c k a g e v e n d o r s p a r t i c i p a t e i n i t .

Whats DeviceXPlorer
OPC Server providing abundant connectivity
D e v i c e X P l o r e r i s a O P C S e r v e r t h a t c o m m u n i c a t e s wi t h a l l k i n d s o f f i e l d s d e v i c e s s u c h a s P L C a n d m e a s u r i n g i n s t r u m e n t s . D e v i c e X P l o r e r c o r r e s p o n d s wi t h
a l l s p e c i f i c a t i o n o f O P C D A , E t h e r n e t , S e r i a l a n d o r i g i n a l n e t wo r k s , s o t h a t i t
c a n b e u s e f u l i n a n y s c e n e s i n o p e r a t i n g f a c t o r y.

O PC C l ien t

ERP/MES
SCADA
DCS

Visual Basic
Visual C/C++
VB.NET
C#.NET

EXCEL
VBA
VSTO

OPC Interface

In the evolving facilities or changing scene,


we pursue Operational Excellence.

DeviceXPlorer
OPC Server

In developing and evolving manufacturing industry, OPC assume a core of informationoriented.

DeviceXPlorer which utilizes its benefit to the full and connects the

enterprise top and site.

Ethernet/RS232C

DeviceXPlorer is evolving with PLCs w hich become more

highly functional and speed up.

TAKEBISHI contemplates the fut ure in production site

and offers the most advanced and appropriate solution.


1

Feature
Features
Connectivity - Multiple PLC

Multiple Language

Unified all PLC into single namespace !


MELSEC

SYSMAC

TOYOPUC

ControlLogix

English, Japanese, Chinese

Sharing between OPC Clients

Provide the latest OPC technology

You will switch locale to keep communication by only selecting the target language on Option dialog of Tool
menu. So you can select suitable user interface for any
engineer operating OPC Server. It supports Japanese,
English, Chinese (Simplified Chinese.)

You will share the application data between OPC Clients


through shared memory in DeviceXPlorer. By developing
application which communicates to field device, it also
works as a custom OPC Server.

Our DeviceXPlorer corresponds to OPCDA3.0.


Therefore, even if the OPC client is developed with VB/VC etc,
some functions added with OPCDA3.0 such as MaxAge
and KeepAlive can be used.

Custom Application

OPC Server
OPC

SYSMAC

Memory

MELSEC

OPC DA 3.0

Shared Memory

SCADA
OPC

SIMATIC-S7
TOYOPUC

DeviceXPlorer supplies the shared memory by default.

.
.
.
It used each kinds of OPC Server when there were some
kinds of PLC in the factory. DeviceXPlorer DXP2007 series integrated all existing products and communicate with
multiple PLCs. So, OPC client only access single namespace and then it can access all PLCs.

SCADA Ready
Compatible with all of SCADA
(Windows language pack is required)

We testified DeviceXPlorer communicate with following


OPC Client software such as SCADA/DCS/MES.
Vendor

Redundant communication
Static tag and Dynamic tag
Standardization by using alias name
DeviceXPlorer supports Static tag and Dynamic tag. Tags
that are defined in advance are called "Static tag" and
tags that are not defined in advance are called "Dynamic
tags." Using Static tag allows client to access PLC without caring physical devices.
Even if PLC vendor has
changed, system can be reorganized without physical tags
name. So, flexible system can be built with benefit of
OPC. Dynamic tags access physical address of PLC directly, so that engineers can save time to specify tags.

Configuration file A
Speed

Temp

Speed

Temp

D0

D1

DM10

DM11

D0

D1

DM10

DM11

New model PLC

InTouch, Historian, IAS

Assigning duplex ports to a device

GE Intelligent Platforms

Cimplicity, iFix

Mitsubishi, Rockwell AB, Siemens

It is possible to construct redundant communication to


assign duplex communication ports to a device. When the
trouble such as cable breaking occurs in one communication route, it switches to another communication route and
continues working. OPC Client doesn't have to care that
communication route has been switched.

Rockwell Automation

RSView

Siemens

WinCC

ICONICS

Genesis, GraphWorX

You will access to the newest models of ControlLogix of


Rockwell, Simatic-S7 of Siemens, MELSEC of Mitsubishi
so we are always expanding device connectivity.

National Instruments

LabVIEW

Citect

CitectSCADA

JT Engineering

JoyWatcher

Yamatake (azbil)

Harmonas, PREXION, DGPL2

Yokogawa

ASTMAC, ExaPilot

2set of LAN adapters

Break

Switch

Finding cause of trouble

Configuration file B

DeviceXPlorer is confirmed excellent


connectivity between global OPC
packages at the OPC Interoperability
Workshop. And also DeviceXPlorer
corresponds to OPCDA2.0/3.0 compliance certifications.

Wonderware

RAS diagnosis
Temp

Passing all certifications

Product

DeviceXPlorer can diagnose status of connections, configured parameter, and tag information and so on for each
OPC interface, DDE/SuiteLink interface. RAS diagnosis
enables to trace easily of source of unexpected troubles
and it shortens the down time.

AB ControlLogix

Siemens S7-1200

10,000-20,000 points per second

Compatible with 64bit OS


DeviceXPlorer products bundles 64bit OPC Server which
has high performance on Win64 system.
Following connectivity are not support
W indows 64bit operating system.
- DDE/SuiteLink communication
- MELSEC EZSocket communication
- MELSEC PC board communication
- SYSMAC FinsGateway communication
- TOYOPUC CPU port communication
- FANUC FOCAS1/2 communication

MELSEC-L

Communication performance

OPC Server x64 Edition

Speed

OPC Compliance Test

on

Command is optimized for each PLC protocol, so high


performance is achieved. In case of Ethernet communication of MELSEC-Q series, it can access to 20,000
points of register per second at the maximum.
Environment
Pentium4 1.8GHz RAM512MB
100BASE-TX
Scan Time - under 10ms
Access points is the continuous
area of data register.
The device value is changed
every scan.

Windows 7, Windows Server 2008


Latest Operating System
PLC A

PLC B

DeviceXPlorer supports W indows 7 and Vista.


are depends on each PLC status.
- MELSEC EZSocket communication
- MELSEC PC board communication
- SYSMAC FinsGateway communication
- TOYOPUC CPU port communication
- FANUC FOCAS1/2 communication

But following connectivity

Standard communication performance.


(MELSEC-Q series Ethernet communication)

Field Devices
MITSUBISHI MELSEC

OMRON SYSMAC

Support the new and the legacy MELSEC !


MELSEC-Q

MELSEC-L

MELSEC-Q is main
series. It has Universal Model, Redundant CPU, Process CPU and more.

MELSEC-L series is
popular model attached Motion, DIO
and field network.

MELSEC-FX

MELSEC-FX series
is used as a sensor
controller in small
system.

MELSEC-A

MELSEC-QnA

MELSEC-QnA series
looks like A series
on the outside, but
software
architecture is Q series.

SYSMAC-CJ2

FinsGateway 2003

DeviceXPlorer supports CJ2 series which control with


high performance and CP series which deliver high cost
performance.

MELSEC-A series is
discontinued
lines
but it is still working in many plants.
SYSMAC-CJ2

SYSMAC-CP

SYSMAC-CS

FINS Network
Transient Communication
DeviceXPlorer supports to access to target station on
MELECNET/H or CC-Link/IE through Ethernet connecting
station.

When you use FinsGateway 2003, DeviceXPlorer enables


to access Communication Link Board, SYSMAC Link
Board and also CS1D redundant control system.

Control sliding packet


When you use Q4E protocol, it is embedded a sequence
number in each request message. And when timeout error
is occurred, it protects to happen a lag between request
message and reply message.

You can access to target station on FINS network by


specifying Network number, Node number, and Unit number.

(It is not compatible SysmacGateway.)

FINS/TCP Communication
You can use FINS/TCP protocol for CJ. DeviceXPlorer
communicate with node number published from SYSMAC
at established connection.

Expended data memory (EM)


You can access EM by designating a bank number and
device number, For example, you designate EM1: 9999
so that you access an address 9999 of bank1.

JTEKT TOYOPUC
Random Access Buffer
Multiple CPU and Redundant CPU
You will access to each device memory in Multiple CPU
System. And you can build system smoothly so CPU refresh parameter setting is not required. Also, DeviceXPlorer supports to access the data with specifying Control/Standby in redundancy system.

Direct access to SP Unit


DeviceXPlorer supply the way to access buffer memory in
each Special Unit. For example, select QD75 as Special
unit and then accessing the tag named "G800", you will
get the forward present value.

When you access the random access buffer over Ethernet,


you can get more fast data exchange not depends on the
scan time.

TOYOPUC-PC10 Series
DeviceXPlorer supports small programmable controller called PC10 series which has
high speed calculation CPU, large memory
and many communicative useful functions.

Layer Link Access


DeviceXPlorer supports Layer Link access from ME-NET,
FL-net, and HPC Link through connecting station. And it
accesses by designating a program number, Link number
and Port number of bridge station.

Stand-alone Motion Q170M


DeviceXPlorer supports stand-alone motion controller called Q170MCPU. So you will access to
both motion control system and discrete control
system.

Batch access for many values


You can get many values at a once by separating tags
with slash symbol. For example, when you access 4 point
of Device1.D0/D1000/ZR200/M0 at a once, you can get
values of 100, 9876, -32768, 1.

Expanded Buffer Register


DeviceXPlorer is available to access to Extension Buffer
register (EB) of PC10/PC3.

Random Access Command


It is possible to get/poke un-continuous device area at a
once by using Random Access command. So, it delivers
high throughput on even large system.

Field Devices
YOKOGAWA FA-M3
Buffer Access Memory
You can access to buffer memory in the special module
(analog input/output, temperature control, or PID control
etc...) by designating unit number and slot number of target module. Please use an Ethernet module on and after
version Rev.03.00, when you access to the buffer memory
(a special module data.)

FUJI MICREX
FA-M3 Unsynchronized Command
When you use F3LE01-5T, you can use the unsynchronized command which is not affected scan time. The
command make it possible to get 502 points as the register value (normally: 251 points) at a once.
(Data synchronism is guaranteed by 16 bit.)

MICREX-SX & MICREX-F


DeviceXPlorer supports SPH3000 series which has high
speed and high confidence, SPH2000 series as board
type, and MICREX-F series. It provides a wide connectivity from latest facility to legacy facility.

MICREX-SX

HITACHI HIDIC
Task Code Version 5
DeviceXPlorer supports the HIDIC Task Code communication version5, so you can access efficiently to enhance
CPU such as EH150 series, H-4010 Series. It supports a
binary code communication with TCP/IP and UDP/IP.

You can access to any station on Satellite Net through


Ethernet connecting station by designating the port number and slot number.

MICREX-F

PANASONIC FP
LUMP Address
You can access to other station through CPU link by designating a LUMP address (loop number, unit number,
module number and port number.)

SHARP SATELLITE
Support for Satellite Net

P Link / PE Link Module


You can access to broad cast area in P Link module and
PE Link module. Also, DeviceXPlorer supports common
memory of FL-net module.

FP-X & FP2


DeviceXPlorer communicates to FP-X series
and FP2/FP2SH series across Ethernet. You
can access to network station on computer
link by designating an unit number of PLC.

Layer Access
With using FP2/FP2SH series, you can access the layer
network by designating a station address of gateway.

YASUKAWA MP
Type of Bit and Byte and Word
You can access some devices of Bit type, byte type, and
word type.

Expanded MEMOBUS
The Ethernet module of MP2000 series is available to use
the expanded MEMOBUS command. It is expanded access point of batch reading/write commands and supports
random write command to retention register. You will get
more high speed communication by using the expanded
MEMOBUS command.

Network Access / Word Swap


You can access to network station by designating slave ID
of target Ethernet module. when you access data type as
LONG type, LONGLONG type, FLOAT type, and DOUBLE
type, you can swap upper word and lower word.

Field Devices
KEYENCE KV
KV-5000 & KV-LE20V
You can access to internal Ethernet port of KV-5000 Series. DeviceXPlorer supports ASCII code on computer link
command, and you will select TCP/IP and UDP/IP. You
can communicate with high performance so KV-LE20V is
expanded to a maximum of 1000 words per request.

FANUC PMC
Full-supported Devices
DeviceXPlorer supports all of KV devices such as data
memory, control memory, and expanded memory etc.

FOCAS1 / FOCAS2
You can get PMC data by using FOCAS1 or FOCAS2 for
designated IP address and port number.

Access to device of PMC


You can access device information including internal
relay, counter, and data
table etc by designating
PMC type in each NC.

(FOCAS1 or FOCAS2 is required.)

ROCKWELL AB
Symbolic Segment
You can define symbolic segment of global tag as OPC
Item. For example, the tag defined Struct1.Bool1 in ControlLogix is accessed item ID as Device1.Struct1.Bool1.

MODBUS
EtherNet/IP(CIP Service)
You can access to the CPU
supported EtherNet/IP by designated
CIP
port
number
(backplane is fixed to "1") and
CIP link address.

MODBUS/TCP
DeviceXPlorer supports Ethernet communication (MODBUS/
TCP) and Serial communication (MODBUS/ASCII, MODBUS/RTU). It is available to swap in the case of LONG,
LONGLONG, FLOAT, and DOUBLE.

MODBUS Expanded Area


DeviceXPlorer supports Input status, Output coil, Input
register, and Extended register. It is available to access a normal address and extended address of 10000
address and more. And You can connect to network
station by designating MODBUS slave ID.

It is available to set the based data type in CPU.

SIEMENS SIMATIC-S7
S7 Protocol
You can access to Ethernet module of S7-300 Series and
S7-400 Series because DeviceXPlorer supports S7 protocol (TCP/IP).
Also DeviceXPlorer supports to access
internal Ethernet port of latest Series called S7-1200.

OPCDA
Unnecessary CP Card
It is not necessary CP card and SIMATIC NET library on
the PC. OPC Server communicate with PLC via native
Ethernet.

Third Party OPC Server


DeviceXPlorer wraps third party OPC Server and provide
OPC interface adapted OPC certification.
You will use
OPC Server which does not compatible with OPC fullinterface in the system.

Synchronous / Asynchronous
DeviceXPlorer supports 4 interfaces in the case of
reading from OPC Server, such as Synchronous Read
(device/cache read), Asynchronous Read, Advise, and
Item I/O Read.

(S5 protocol is not supported.)

If OPC Server does not support the write I/F,


you can choose it to NONE.

10

Specification
Module List
Vendor

Series

MELSEC-Q

MITSUBISHI

FX3U-ENET(-L)

FXxx-232-BD
FXxx-485-BD
FXxx-232ADP
FXxx-485ADP
CPU Serial port

MELSEC-QnA

Q4A(R)
Q3A
Q2A(S/SH)(-S1)

A(1S)J71QE71(N)-T
A(1S)J71QE71(N)-B2
A(1S)J71QE71(N)-B5

AJ71QC24(N)(-R2/-R4)
A1SJ71QC24(N)(-R2)
CPU Serial port

MELSEC-A

A4U
A3(N/A/U)
A2(N/A/U)(S/SH)(-S1)
A1(N)(S/SH)

AJ71E71(-S3)
A(1S)J71E71(N)-T
A(1S)J71E71(N)-B2
A(1S)J71E71(N)-B5

AJ71UC24 *2
AJ71C24-S8
A1SJ71UC24
CPU Serial port

SYSMAC-CJ

CJ2H
CJ1G
CJ1H
CJ1M

CJ1W -ETN11/21
CJ1W -EIP21 *3
CPU Ethernet port

CJ1W -SCU42/32/22
CJ1W -SCU41/31(-V1)
CJ1W -SCU21(-V1)
CPU Serial port

CS1G
CS1H
CS1D

CS1W -ETN21/11/01
CS1W -EIP21 *3
CS1D-ETN21D

CS1W -SCU31/21(-V1)
CS1W -SCB41/21(-V1)
CPU Serial port

SYSMAC-CP

CP1E
CP1L
CP1H

CP1W -ClF41
CJ1W -ETN21
CJ1W -EIP21 *3

CP1W -CIF12/11/01
CJ1W -SCU41/31(-V1)
CJ1W -SCU21(-V1)

SYSMAC-CV

CVM1(D)
CV2000
CV1000
CV500

MELSEC-FX

CV500-LK201
CPU Serial port

Q81BD-J71LP21-25
Q81BD-J61BT11
Q80BD-J71GP21(S)-SX
Q80BD-J71LP21(S)-25
Q80BD-J71LP21G
Q80BD-J71BR11
Q80BD-J61BT11N
GX-Simulator *1

Series

CPU

DXPSTL-U

JW -255CM
JW -25TCM
JW -51CM

J-Board

Z-300
Z-500

Z339J

MICREX-SX

SPH3000
SPH300
SPH300EX
SPH2000
SPH200

NP1L-ET1
NP1L-ET2
CPU Ethernet port

NP1L-RS1
NP1L-RS2
NP1L-RS3
NP1L-RS4
NP1L-RS5

MICREX-F

F150S
F140S
F120S
F120H
F80H
F70
F55

FFU170B
NC1L-ET1

FFU120B
NC1L-RS2
NC1L-RS4
NV1L-RS2

FP-X

FP-X C60R/T/P(D)
FP-X C30R/T/P(D)
FP-X C14R/T/P(D)

FP-X COM5

FP2

FP2
FP2SH

FP2 ET-LAN

MP2000

MP2400
MP2310
MP2300(S)
MP2200

218IF-01
218IF-02
CPU Ethernet port

MP900

MP920

218IFA

KV

KV-5000
KV-3000
KV-1000
KV-700

KV-LE20V
KV-LE20A
KV-LE20

AB ControlLogix

1756

1756-ENBT

AB CompactLogix

1769-L35E
1769-L32E
1768

1768-ENBT
CPU Ethernet port

AB FlexLogix

1794

1788-ENBT

AB DriveLogix

5730/5720

1788-ENBT

SIMATIC-S7

S7-1200
S7-400
S7-300

CP443-1
CP343-1
CPU Ethernet port

FANUC PMC

320i
310i
300i
210
160i-L
160i-W ,180i-W
160i-P,180i-P
160i-B,180i-B,210i-B
160i-A,180i-A,210i-A
160
180
150i
150
0i-A
0i-B

CPU Ethernet port


PCMCIA Ethernet card

FANUC Power Mate

PMi-H
PMi-D

CPU Ethernet port


PCMCIA Ethernet card

MODBUS

MODBUS/TCP

DXPMDB-U

MODBUS devices
HIOKI 2300 SmartSite
M-SYSTEM R3 Series etc

DXPOPC-U

(OPC DA Server)

PANASONIC

SYSMAC-C

SYSMAC-One NSJ

NSJ

NSJW -ETN21
CPU Ethernet port

TOYOPUC-PC10

PC10G
PC10GE

EN-I/F(-T)
FL/ET-net-5
FL/ET-T-V2(H)
CPU Ethernet port

CPU Serial port

TOYOPUC-PC3J

PC3J(L/D/M/NM/NF)
MULTI-GW

EN-I/F(-T)
FL/ET-net-5
FL/ET-T-V2(H)

CPU Serial port

TOYOPUC-PC2J

PC2J(C/S/R)
PC2J16(R/H/PR/HR)

EN-I/F(-T)
FL/ET-net-5
FL/ET-T-V2(H)

CPU Serial port

FA-M3(R)

F3SP67-6S
F3SP66-4S
F3SP59-7S
F3SP58-6H/S
F3SP53-4H/S
F3SP38-6N/S
F3SP35-5N
F3SP28-3S/N
F3SP25-2N
F3SP21-0N
F3SP08-0P
F3SP05-0P

F3LE12-0T
F3LE11-0T
F3LE01-5T

HIDIC EH150-EHV

EHV-CPU128/64/32/16

EH-ETH

HIDIC EH150

EH-CPU548/516/316A
EH-CPU208A/104A

EH-ETH

HIDIC-H

H-4010
H-2002
H-1002
H-702
H-302
H-252

LAN-ETH(2)

*6

YASUKAW A
DXPYMP-U

Controller Link, etc

*4

KEYENCE
DXPKKV-U

ROCKW ELL

*7

DXPALB-U

SIEMENS
DXPSMT-U

FANUC

*8

DXPGFC-U

(General)
F3LC12-1F
F3LC11-2F/1F
F3LC11-2N/1N

OPCDA

(Shared Memory)
*1
*2
*3
*4
*5
*6
*7
*8
*9

Serial

JW 300
JW 100H
JW 70H
JW 50H
JW 30H/20H

DXPMRX-U

DXPPFP-U

Ethernet

SATELLITE-JW
SHARP

C500-LK203/201
C500-LK103/101
C200-LK202/201/101
C120-LK202/201/101
CPU Serial port

C200H
CQM1(H)
CPM1/2
C2000H/C1000H

HITACHI

11

CV500-ETN01

Vendor

Others

FUJI

FX3U(C)
FX3G
FX2N(C)
FX1(S/N/NC)
FX0(S/N)

DXPFAM-U

DXPHID-U

CPU Ethernet port

QJ71C24N
QJ71C24N-R2
QJ71C24N-R4
CPU USB port
CPU Serial port

CPU Ethernet port

DXPTYP-U

YOKOGAW A

Q170M
MELSEC-L

OMRON

*5

QJ71E71-100
QJ71E71-B2
QJ71E71-B5
CPU Ethernet port

Serial

LJ71C24
LJ71C24-R2
CPU USB port

SYSMAC-CS

JTEKT

Ethernet

Q26UD(E)H
Q25(H/PH/PRH)
Q20UD(E)H
Q13UD(E)H
Q12(H/PH/PRH)
Q10UD(E)H
Q06(H/PH/UDH/UDEH)
Q04UD(E)H
Q03UD(E)
Q02(U/H/PH)
Q01(U)
Q00(U)(J)

L26CPU-BT
L02CPU

DXPMEL-U

DXPSYS-U

CPU

(ALL)

*9

Others

MODBUS/RTU
MODBUS/ASCII
OPC DA2.05A/3.0

(MEMORY MAPED FILE)

Unsupported GX-Simulator2.
Support communication protocol of MELSEC-A Series as type1 and type4.
Support Fins protocol. Unsupported EtherNet/IP communication.
FinsGateway is required for Controller Link communication. For Ethernet and Serial communication, FinsGateway is not required.
JTEKT communication library(TJA-2067) is required for CPU internal port communication.
Support Expended MEMOBUS protocol.
Support EtherNet/IP (CIP service) communication.
FUNUC FOCAS1 or FOCAS2 are required.
Available to connect to SCADA or third partys OPC Server through OPC DA interface.

12

Lineup
Price List

Performance specification
Item
OS

*1

Description

DeviceXPlorer OPC Server Standard License


Product

W indows 7/Vista/2008/2003/XP/2000
*2

Application type
Hard disk

32bit Application(W in32/x86), 64bit Application (W in64/x64)

DXP MELSEC OPC Server

100MB or more (MELSEC EZSocket and SYSMAC FinsGateway communications require more than
200MB)

DXP SYSMAC OPC Server

*1

Model

I/F

Support PLC

ETN

RS2

etc

DXPMEL-U

MITSUBISHI MELSEC-Q/L/FX/QnA/A Series

DXPSYS-U

OMRON SYSMAC-CJ/CS/CP/CV/C Series

DXPTYP-U

JTEKT TOYOPUC-PC10/PC3J/PC2J Series

DXP FA-M3 OPC Server

DXPFAM-U

YOKOGAW A FA-M3 Series

*2
*3

DXP TOYOPUC OPC Server

Memory

1GB or more

License

It requires a license for each computer to install.


(There are no restrictions for the number of PLC connections and OPC client connections)

DXP HIDIC OPC Server

DXPHID-U

HITACHI HIDIC-EH/H Series

Protection

Protected by software key (Protected by USB key for Asian countries)

DXP SATELLITE OPC Server

DXPSTL-U

SHARP SATELLITE JW Series

VB.NET, Visual Basic(VS2010, VS2008, VS2005, VS6.0), VBA, VSTO

DXP MICREX OPC Server

DXPMRX-U

FUJI MICREX-SX/F Series

C#.NET, Visual C/C++(VS2010, VS2008, VS2005, VS6.0)

DXP FP OPC Server

DXPPFP-U

PANASONIC FP-X/FP2 Series

MTA (Free Threading)

DXP MP OPC Server

DXPYMP-U

YASUKAW A MP2000 Series (MEMOBUS)

Possible

DXP KV OPC Server

DXPKKV-U

KEYENCE KV Series

256

DXP AB OPC Server

DXPALB-U

ROCKW ELL AB ControlLogix (EtherNet/IP)

Maximum Tags

Unrestricted

DXP SIMATIC OPC Server

DXPSMT-U

SIEMENS SIMACTIC-S7 Series

Protocols

OPC-DA3.0, OPC-DA2.05A, DDE, SuiteLink

DXPGFC-U

FANUC PMC Series

Alias Tag Name

Possible

DXP MODBUS OPC Server

DXPMDB-U

MODBUS/TCPMODBUS/RTUMODBUS/ASCII

Development Language
Threading Model
W indows Service Activation
*3

Maximum PLCs

Simulation Mode

Extended Format

*1

*2
*3

13

*4

USD 680

Possible (Sine/Ramp/Shared memory)

DXP OPCDA OPC Server

DXPOPC-U

Takebishi.Dxp.1

DXP Standard License 10 PACK

DXP-L10-U

*6

1 media and 10 Licenses set

USD 5,800

OPC Access Path

Possible

DXP-V-U

*6

Upgrade to the latest version

USD 340

OPC Item ID

Use delimiters to specify device, group and tag names.

ETN

RS2

etc

Data type

*4

*4

DXP FANUC OPC Server

PROG.ID

OPC

DDE/SuiteLink

*4

Price

DXP Standard License Version up

VT_BOOL

(Logical values)

VT_BOOL | VT_ARRAY

VT_I1

(8 bit signed integers)

VT_I1 | VT_ARRAY

VT_UI1

(8 bit unsigned integers)

VT_UI1 | VT_ARRAY

VT_I2

(16 bit signed integers)

VT_I2 | VT_ARRAY

VT_UI2

(16 bit unsigned integers)

VT_UI2 | VT_ARRAY

VT_I4

(32 bit signed integers)

VT_I4 | VT_ARRAY

VT_UI4

(32 bit unsigned integers)

VT_UI4 | VT_ARRAY

DeviceXPlorer OPC Server Enterprise License


Product

DXPENT-U

Support above all PLC

USD 1,280

DXPENT-M3-U

W ith Free update service / Spot service

USD 1,980

DXP Enterprise OPC Server

with 5 Years Maintenance

DXPENT-M5-U

W ith Free update service / Spot service

USD 2,980

DXPENT-L10-U

1 media and 10 Licenses set

USD 11,000

DXPENT-V-U

Upgrade to the latest version

USD 640

DXPENT-CHG-U

From standard license to Enterprise license

USD 640

ETN

RS2

etc

DXP Enterprise 10 License Pack

VT_R4 | VT_ARRAY

(64 bit signed integers)

VT_I8 | VT_ARRAY

DXP Enterprise Version up

VT_UI8

(64 bit signed integers)

VT_UI8 | VT_ARRAY

DXP Enhanced Upgrade

VT_R8

(64 bit signed real number)

VT_R8 | VT_ARRAY

VT_BSTR

(Character string)

VT_BSTR | VT_ARRAY

VT_ARRAY

(Array)

Any (Default: Device name)

*2 *3 *4

Price

with 3 Years Maintenance

(32 bit signed real number)

Topic Name

I/F

Support PLC

DXP Enterprise OPC Server

VT_I8

Any (Default: Dxp)

*1

Model

DXP Enterprise OPC Server

VT_R4

Application Name

*5

OPC DA2.05A/3.0

*5

*5

Option
I/F
Product

Boolean

ex: M100 = 0 (100 of internal relay)

Bit position of word device

ex: D1:15 = 1 (15th bit of D1)

16 bit signed integers

ex: D1:W = 32767 (1 of data register)

*1

16 bit unsigned integers

ex: D1:U = 65535 (1 of data register)

*1

32 bit signed integers

ex: D1:D = 2147483647 (32 bit of D1 to D2)

32 bit unsigned integers

ex: D1:DU = 4294967295 (32 bit of D1 to D2)

64 bit signed integers

ex: D1:I = 2147483647 (64 bit of D1 to D4)

64 bit unsigned integers

ex: D1:IU = 2147483647 (64 bit of D1 to D4)

DXP FinsGateway License

*1
*2

BCD

ex: D1:B = 0x1234 (16 bit BCD from D1)

*3
*4
*5

32 bit signed real number

ex: D1:R = 9.876 (32 bit floating decimal point of D1 to D2)

*6

64 bit signed real number

ex: D1:DR = 1.23 (64 bit floating decimal point of D1 to D4)

Character string

ex: D1:S10 = ABCDEF... (Character string of D1 to D10)

Text format binary

ex: D1:B10 = 00001111... (Binary text of 16 bit / point)

Text format octal

ex: D1:O10 = 173,142,60,... (Octal text divided by comma)

Text format decimal

ex: D1:D10 = 32767, 255, -1,... (Decimal text divided by comma)

Text format hexadecimal

ex: D1:H10 = FFFF00001234... (Hex text of 4 figures / point)

Array

ex: D1:A10 (array D1 to D10)

Read-only

ex: D1:OR (forbid write to tag)

Write-only

ex: D1:OW (do not read tag)

following connectivity are depends on each PLC status.


-MELSEC EZSocket communication
-SYSMAC FinsGateway communication
-TOYOPUC CPU port communication
-FANUC FOCAS1/2 communication
You can install to select 32bit or 64bit OPC Server. Please refer to the manual for the limitation of 64bit OPC server.
The performance decreases as increasing number of PLC connections.
When you access 10 PLCs or more, it is recommended to use Hyper Threading CPU or Dual Core CPU.
DDE/SuiteLink for W indows 7/Vista/2008 and 64 bit OS are not guaranteed by manufacturers (W onderware.)

Model

DXPFGW -U

Support PLC
For DXP SYSMAC OPC Server or Enterprise
license

You can select English version or Japanese version.


If you would like to Japanese, please add to "-J" after the model.
Usually install media is CD type.
If you want to use USB media, please add to "-USB" after the model.
Shared memory connectivity is available with all of DeviceXPlorer Standard/Enterprise license.
For using FinsGateway communication such as ControllerLink board, purchase FinsGateway
license for DXP (DXPFGW ) separately. SysmacGateway is not supported.
It needs JTEKT "Communication library" for accessing to TOYOPUC CPU internal serial port.
FANUC "FOCAS1" or "FOCAS2" is required.
To get an upgrade service and enhanced upgrade service,
it is need to show user's information and product serial number on ordering.
DXP-U: Please select a model letter of standard license.

License Pack
The license pack (DXP-L10-U) includes with a install media and 10 licenses.
Please mentioned that you do not upgrade for each other.

Price

USD 290

CD media (Model: DXP-U)

USB media (Model: DXP-U-USB)

Technical Support Service


The products are included with technical support service. You can inquire by email, telephone, and
FAX. And you will download software patches every time.
Upgrade Service
If you have standard license or enterprise license, you can upgrade the latest version by free within 1
year after purchase it at only once. (without major upgrade) It needs to register the user information.
After 1 year of purchase, you should purchase the upgrade product (model: DXP-V-U).
Software Maintenance Service
You can add 3 years maintenance service or 5 years maintenance service to Enterprise license.
There are Free update service and Spot service. Free update service supplies to upgrade by free
every time in the term (including major upgrade.) The spot service make you possible to request a
engineer goes to the field site with extra fee. It is NOT free service.
You can not change or extend the term of maintenance service.