0% found this document useful (0 votes)
97 views7 pages

Environmental and Water Quality Monitoring Buoy - Suhaili Specification

The document describes the specifications for an environmental and water quality monitoring buoy system. It includes: 1. Sensors to measure wind speed, wind direction, temperature, humidity, precipitation, air pressure, solar irradiance, albedo, and water quality parameters like pH, dissolved oxygen, conductivity, temperature, and chlorophyll. 2. A data acquisition system that samples and stores sensor data, allows for automatic daily data transfer via cellular network, and includes alarms and status monitoring. 3. An ioLogik data logger to collect and transmit sensor data. 4. A floating buoy base and solar power system to deploy the sensor assembly and power the system.

Uploaded by

Suhaili Yahya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
97 views7 pages

Environmental and Water Quality Monitoring Buoy - Suhaili Specification

The document describes the specifications for an environmental and water quality monitoring buoy system. It includes: 1. Sensors to measure wind speed, wind direction, temperature, humidity, precipitation, air pressure, solar irradiance, albedo, and water quality parameters like pH, dissolved oxygen, conductivity, temperature, and chlorophyll. 2. A data acquisition system that samples and stores sensor data, allows for automatic daily data transfer via cellular network, and includes alarms and status monitoring. 3. An ioLogik data logger to collect and transmit sensor data. 4. A floating buoy base and solar power system to deploy the sensor assembly and power the system.

Uploaded by

Suhaili Yahya
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 7

Environmental and Water Quality Monitoring Buoy

SENSOR SPECIFICATION MEASUREMENT SYSTEM


Environmental sensors with wave-motion and temperature compensation
1)
Wind speed at 2m height
Principal: Relay Reed
Measuring Range: 0-75 m/s
Uncertainty: 2.5% (Calibration tested to 63m/s)
Threshold: 0.5 m/s
Output : 2.65 Hz x m/s
Connector: 4pin IP65 watertight connector
Housing: Anodized aluminium
Operating Temperature: -35+70oC
2)
Wind direction at 2m height
Principal: Hall effect sensor
Measuring Range: 0-360o
Threshold: 0.25m/s
Uncertainty: 5o
Output: 0-1V
Connector: 4pin IP65 watertight connector
Housing: Anodized aluminium
Power supply: 10-14 Vdc
Power Consumption: 10mA
3)
Ambient temperature covered, at 1m height
Principal: Pt1100 1/3 DIN B
Measuring range: -50oC + 70oC
Uncertainty: 0.1oC (0oC)
Resolution: 0.01oC
Protection type: IP54
4)
Relative humidity
Principal: Capacitive
Measuring Range: 0-100%
Uncertainty: +/- 1.5% RH ( 5-95%)
Output: 0-1Vdc
Protection type: IP54
5)
Precipitation
Diameter: 200mm
Collection Surface: 324 cm2
Weight: 2kg
Principal: Tipping bucket
Design: WMO accordance
Resolution: 0.2mm
Housing: Aluminium
6)
Air pressure
Principal: Piezoelectric
Range: 800-1110 hPa
Maximum pressure limit: 2000hPa
Protection: IP43

7)

8)

Output: 0-1 V
Power supply: 10-14 Vdc
Power consumption: 0.25W
Uncertainty: 1hPa
Global horizontal irradiance unshaded, at 1m or 2m height
Principal: Thermopile
ISO 9060 Classification: Second class
Spectral range: 305-2800 nm
Uncertainty ( Daily totals) : 10%
Response time: 30S
Operative Temperature: -40-80oC
Output: uV/W/m2
Maximum irradiance: 2000W/m2
Global horizontal albedo unshaded, at 1m or 2m height
Principal: Thermopile
ISO 9060 Classification: Second class
Spectral range: 305-2800 nm
Uncertainty ( Daily totals) : 10%
Response time: 30S
Operative Temperature: -40-80oC
Output: uV/W/m2
Maximum irradiance: 2000W/m2

9)
Water velocity/current depth 0.5 -1m - IS IT NESSECARY?
10) Wave height and direction or buoy tilt angle sensor
Water quality sensor
Protection Class: IP68 ( Permanent Immersion)
Immersion Depth: Min 75mm Max 100M
Operating Temperature: -5oC + 70oC
Dimension (L x Dia) : 290mm x 42mm
Weight: 700g
1)
pH level
Range: 0-14pH /+/- 625mV
Resolution: 0.01pH / +/- 0.1mV
Accuracy: +/- pH/ +/-5mV
2)
Dissolved oxygen
Range: 0-500.0% / 0 -50.00 mg/L
Resolution: 0.1% / 0.01 mg/L
Accuracy: 0-200%:+/- 1 % of reading , 200%-500%: +/- 10%
3)
Conductivity
Range: 200mS/cm (0-200,000S/cm)
Resolution: 3 auto range scales: 0-9999S/cm, 10.00-99.99 mS/cm, 100.0
200.0 mS/cm
4)
Water temperature
Range: -5oC + 70oC
Resolution: 0.1oC/F
Accuracy: +/- 0.5oC

5)

Chlorophyll
Resolution: 0-500g/L (ppb)
Resolution: 2 auto range scales: 0.00-99.99g/L, 100.0-500.0 g/L
Repeatability: +/- 5% of reading

Data acquisition system


1)
Data sampling interval: 10s (enviro), 30s (water)
2)
Data averaging: 1m (enviro), 5min (water)
3)
Storage: shall last 14-day worth of data
4)
Automatic data transfer: via 3G or GPRS
5)
Transfer protocol: FTP via IP
6)
Alarm logging: every occurrences
7)
Power supply: adequate battery
8)
Battery health check: every 10min
9)
DAQ storage check: every 30min
10) DAQ health check: every 30min
11) Manual data transfer: via USB
12) Shall has LCD display for minimal DAQ status update and interface DAQ
settings
13) Real-time data relay: every 15min
14) Alarm notification via email
15) Time synchronization with selected time server
Our Specification:
ioLogik W5312/W5312-T Specifications
Inputs and Outputs
Digital Inputs: 8 channels
Digital Outputs: 8 channels
Configurable DIOs: 4 channels
Isolation: 3K VDC or 2K Vrms
Digital Input
Sensor Type: Wet Contact (NPN or PNP) and Dry Contact
I/O Mode: DI or Event Counter
Dry Contact:
On: short to GND
Off: open
Wet Contact (DI to GND):
On: 0 to 3 VDC
Off: 10 to 30 VDC
Common Type: 6 points per COM
Counter Frequency: 900 Hz, power off storage
Digital Filtering Time Interval: Software selectable
Digital Output

Type: Sink
I/O Mode: DO or Pulse Output
Pulse Output Frequency: 1 kHz
Over-voltage Protection: 45 VDC
Over-current Protection: 2.6 A (4 channels @ 650 mA)
Over-temperature Shutdown: 160C (min.)
Current Rating: 200 mA per channel
DIO Output Leakage Current: 3.6 mA @ 24 VDC
Power Requirements
Power Consumption:
Always on: 156 mA @ 24 VDC
On demand: 138 mA @ 24 VDC
MTBF (mean time between failure)
Time: 407,406 hrs
Database: Telcordia (Bellcore)
Computer
CPU: ARM9 based CPU, 32-bit/160 MHz
SDRAM/Flash:
ioLogik W5312/W5340: 4 MB / 2 MB
ioLogik W5348: 64 MB / 32 MB
Storage
Expansion Slot: Up to 32 GB SD memory card (SD 2.0 compatible)
Note: For units operating in extreme temperatures, industrial grade, widetemperature SD cards are required.
Cellular
Network:
ioLogik W5312/W5340:
Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
ioLogik W5340-HSDPA/W5348-HSDPA-C:
Tri-band UMTS/HSDPA 850/1900/2100 MHz
Quad-band GSM/GPRS/EDGE 850/900/1800/1900 MHz
Internet:
HSDPA:
Up to 3.6M bps upload speed.
Up to 384k bps download speed.
UMTS:
Up to 384k bps upload/download speed.
GPRS/EDGE:
Multi-slot class: Class 10
Coding schemes: CS 1-4, MCS 1-9
Terminal device class: Class B

SMS: Point-to-Point Text/PDU mode


SIM Control Voltage: 3 V
LAN
Ethernet: 1 x 10/100 Mbps, RJ45
Protection: 1.5 KV magnetic isolation
Protocols: Modbus/TCP, TCP/IP, UDP, DHCP, Bootp, SNMP, SNTP
Serial Communication
Interface:
ioLogik W5312/W5340:
1 x RS-232/422/485, software selectable
(9-pin D-Sub male, or 5-contact terminal block)
ioLogik W5348:
2 x RS-232/422/485, software selectable (9-pin D-Sub male)
Baudrate:
300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Power Requirements
Power Input: 24 VDC nominal, 12 to 36 VDC
Physical Characteristics
Dimensions: 46.8 x 135 x 105 mm (1.84 x 5.31 x 4.13 in)
Weight: 495 g
Mounting: DIN-rail (standard), wall (optional)
Environmental Limits
Operating Temperature:
Standard Models: -10 to 55C (14 to 131F)
Wide Temp. Models:
ioLogik W5312/W5340: -30 to 70C (-22 to 158F)
ioLogik W5340-HSDPA/W5348-HSDPA-C: -20 to 70C (-4 to 158F)
Storage Temperature: -40 to 85C (-40 to 185F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications
Safety: UL 508, EN 60950-1, NCC
EMI:
EN 55022; EN 61000-3-2; EN 61000-3-3;
FCC Part 15, Subpart B, Class A
EMS:
EN 55024, EN 61000-4-2, EN 61000-4-3,
EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,
EN 61000-4-8, EN 61000-4-11, EN 61000-6-2
Mobile Network: PTCRB
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32

Vibration: IEC 60068-2-6


Green Product: RoHS, CRoHS, WEEE
Buoy Specification
Connect-a-dock module floating base system
Low profile type, 1000 series
Dimension: 90 x 120 x 10 (228.6 cm x 304.8 cm x 25.4 cm)
Maximum flotation: 2800 lbs (1270 kg) per module
Freeboard: 8 (20.32 cm) above the water
Power Requirement:
1. Solar system photovoltaic module
- Polycrystalline cell
- Cell dimension: 156 x 156 (mm)
- 36 cells and connection
- Dimension of module: 1460 x 655 x 35 mm
- Weight: 12.1 kg
2. Solar charging controller

TYPE
System voltage
Float charge
Boost charge

Equalization
Deep discharge protection:
State of charge dependent
Voltage dependent
Reconnect level
Overvoltage protection
Undervoltage protection
Max. panel voltage
(Overvoltage protection by
varistor)

CML 20A
12/24 V auto recognition
13.7/27.4 V (25 C)
14.4 /28.8 V (25 C), 2 Std.
activation: battery voltage
<12.3/24.6 V
14.8/29.6 V (25 C), 2 Std.
activation: battery voltage
<12.1/24.2 V
11.4 11.9 V / 22.8 23.8 V
11.0/22.0 V
12.8/25.6 V
15.5/31.0 V
10.5/21.0 V
30 V in 12 V system
50 V in 24 V system

Temperature compensation
(Charge voltage)
Max. self consumption
Grounding
Ambient temperature
Max. height
Battery type
Wire cross section
Weight
Dimensions (W xH x D)
Type of protection
3. Solar battery
100Ah, 12 Vdc
Specification
Rated capacity
Nominal voltage
Cells per unit
Design life span
Warranty
Manufactured
Brand
Series

100Ah
12V
6
10 Years
1 Year
China
POWERBATT
PK Series

25 mV/K at 12V
50 mV/K at 24V
< 4 mA
positive grounding possible
40 to +50 C
4,000 m above sea level
lead acid (GEL, AGM, flooded)
< 16 mm2
160 g
80 x 100 x 32 mm
IP22