NAFFCO
Listed
Fire Pumps
2900 RPM
1-1/2 BS 336 male
An Introduction to NAFFCO
NAFFCO FZCO is among the worlds leading
manufacturers and suppliers of top-tier firefighting
equipment, fire protection systems, fire alarms, security
and safety engineering systems worldwide. Since
its humble beginnings, NAFFCO has grown from its
headquarters in Dubai, UAE to expand to serving over
100 countries around the world.
firefighting technology and fire safety solutions, NAFFCO
has worked in both the private and government sectors,
as well as manufacturing plants, hospitals, stadiums,
malls and other organizational projects, delivering
comprehensive fire safety and engineering solutions.
One Stop Shopping for All Your Fire Safety
and Security Needs
NAFFCO is associated with globally renowned
international companies in the fire protection industry
such as Esser, Secutron, Megalights, Evax, Fike, Central,
Shield, Mueller, Giacomini, RB Pumps, Bombas, Ideal
Pumps, Joslyn Pumps, Peerless Pumps.
Todays companies recognize the importance and
convenience of having multiple safety services available
under one roof, a one-stop shopping source for all types
of fire protection systems. As the undisputed leader in
At NAFFCO we are passionate about sustaining,
upgrading and improving any means of safety, by having
over 2 million square foot of manufacturing space, over
450 engineers, and following all the latest technology
available. We live by our passion, the passion to protect.
www.naffco.com
FIRE FIGHTING PUMPS
NAFFCOs UL listed and FM approved fire pumps provide
you with a reliable solution for your fire fighting pump
needs by combining the stringent quality measures of
UL, FM and NFPA standards with our proven experience
in the fire protection field. We can offer you a complete
package of services starting from engineering assistance
to field start-up and periodic maintenance. Each pump set
is tested in our factory, prior to dispatch, as per UL, FM and
NFPA standards. These pumps are covered by a warranty
of one year subject to standard terms and conditions.
END SUCTION PUMPS
FEATURES
Performance characteristics as per NFPA 20
Complete unit responsibility.
Complete in-house fabrication capabilities.
Hydrostatic strength testing facilities.
Operation run test as per NFPA 20, UL 448 and
FM 1319 requirements.
End
suction
models
for
capacities
from
50 to 500 US GPM.
Drivers: Electric motor drive or diesel engine drive.
Electrical testing capabilities for motors and controllers
as per NFPA standards.
Capable to supply additional accessories wherever
required.
Capable of supplying single skid mounted fire pump set.
PUMP CASING
The casing is designed for back pull-out, which permits
the removal of complete rotor unit without removing
suction and discharge pipe. The cast iron volute casing
is of robust design with integrally cast feet, vertical top
centerline discharge with axial suction incorporating cast
inlet vane to give the best flow to the impeller eye.
BEARINGS
Driven end / non-driven end bearings are grease
lubricated deep groove ball bearings.
IMPELLER
Impeller is double shrouded type. It is hydraulically
balanced and positively driven by shaft key and axially
locked between sleeve and impeller nut.
SHAFT SEAL
Soft-packed stuffing box. Graphite impregnated type
gland packing.
www.naffco.com
Approved Fire Pump Models with Ratings
RATED CAPACITY - 50 US GPM
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet Dia.
(Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
1
2
3
4
5
6
7
NF-E 32-20
NF-E 32-26
NF-E 40-20
NF-E 40-26
NF-E 50-20
NF-E 50-26
NF-E 65-20
50-87
88-139
59-95
77-128
58-89
93-138
58-89
---------------
2900
2900
2900
2900
2900
2900
2900
2
2
2.5
2.5
2.5
2.5
3
1.25
1.25
1.5
1.5
2
2
2.5
1
1
1
1
1
1
1
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet Dia.
(Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
1
2
3
4
5
6
NF-E 32-26
NF-E 40-20
NF-E 40-26
NF-E 50-20
NF-E 50-26
NF-E 65-20
126
53-92
70-124
61-91
93-139
58-88
-------------
2900
2900
2900
2900
2900
2900
2
2.5
2.5
2.5
2.5
3
1.25
1.5
1.5
2
2
2.5
1
1
1
1
1
1
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet Dia.
(Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
1
2
3
4
NF-E 40-26
NF-E 50-20
NF-E 50-26
NF-E 65-20
114
62-93
90-139
56-86
---------
2900
2900
2900
2900
2.5
2.5
2.5
3
1.5
2
2
2.5
1
1
1
1
RATED CAPACITY - 100 US GPM
RATED CAPACITY - 150 US GPM
RATED CAPACITY - 200 US GPM
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet Dia.
(Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
1
2
NF-E 65-26
NF-E 65-32
92-141
133-211
94-144
135-216
2900
2900
3
3
2.5
2.5
1
1
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet Dia.
(Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
1
2
3
NF-E 65-26
NF-E 65-32
NF-E 80-32
89-140
132-210
126-208
91-143
133-211
---
2900
2900
2900
3
3
4
2.5
2.5
3
1
1
1
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet Dia.
(Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
1
2
3
4
NF-E 65-26
NF-E 65-32
NF-E 80-26
NF-E 80-32
87-139
129-209
87-135
125-207
88-142
130-206
93-145
132-213
2900
2900
2900
2900
3
3
4
4
2.5
2.5
3
3
1
1
1
1
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet Dia.
(Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
1
2
NF-E 80-26
NF-E 80-32
-----
91-144
131-211
2900
2900
4
4
3
3
1
1
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet Dia.
(Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
1
2
NF-E 80-26
NF-E 80-32
84-133
122-204
88-142
130-209
2900
2900
4
4
3
3
1
1
RATED CAPACITY - 250 US GPM
RATED CAPACITY - 300 US GPM
RATED CAPACITY - 350 US GPM
RATED CAPACITY - 400 US GPM
RATED CAPACITY - 450 US GPM
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet Dia.
(Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
1
2
NF-E 80-26
NF-E 80-32
81-132
119-203
83-141
129-207
2900
2900
4
4
3
3
1
1
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet Dia.
(Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
1
2
NF-E 80-26
NF-E 80-32
130
202
79-139
126-203
2900
2900
4
4
3
3
1
1
RATED CAPACITY - 500 US GPM
www.naffco.com
CUT-SECTIONAL VIEW
DESCRIPTION
No.
Part Name
Material
Qty.
Casing
Cast Iron ASTM A48 Class 40
Impeller
Bronze SAE 40
Wear ring
Bronze SAE 40
Stuffing Box (Casing Cover)
Cast Iron ASTM A48 Class 40
Gland Packing
Graphite Impregnated
Gland
Bronze SAE 40
Lantern Ring
Bronze SAE 40
Bearing Housing
Cast Iron ASTM A48 Class 40
Shaft
Stainless Steel AISI 420
10
Shaft Sleeve
Stainless Steel AISI 420
11
Bearing
Bearing Steel
12
Foot Support
Steel
13
O Ring
Buna N Rubber
14
Coupling Key
Stainless Steel AISI 420
www.naffco.com
DIMENSIONAL DRAWING
Standard
- ASME B16.1
Class Rating - Class 250
TABLE OF DIMENSIONS
Suction Flange
Model
AA
GH
QR
UV
ST
WM
WX
AW
AT
NF-E 32-20
68
100
370
100
70
160
340
190
165
2"
NF-E 32-26
55
120
410
127
95
177
400
250
165
2"
NF-E 40-20
68
100
390
100
70
160
405
212
185
2.5"
NF-E 40-26
62
120
425
125
95
180
405
250
185
2.5"
NF-E 50-20
62
99
390
100
70
160
360
212
185
2.5"
NF-E 50-26
62
120
390
125
95
180
405
250
185
2.5"
NF-E 65-20
63
120
408
125
95
180
405
250
200
3"
NF-E 65-26
62
120
450
160
120
200
450
280
200
3"
NF-E 65-32
132
120
510
165
120
225
505
315
200
3"
NF-E 80-26
88
120
531
160
120
200
480
315
220
4"
NF-E 80-32
133
160
510
160
120
250
565
315
220
4"
www.naffco.com
Discharge Flange
BC
AS
4 Holes 18
on PCD 125
4 Holes 17
on PCD 125
4 Holes 18
on PCD 145
4 Holes 18
on PCD 145
4 Holes 18
on PCD 145
4 Holes 18
on PCD 145
8 Holes 18
on PCD 160
8 Holes 18
on PCD 160
8 Holes 18
on PCD 160
8 Holes 18
on PCD 180
8 Holes 18
on PCD 180
AQ
AO
140
1.25"
140
1.25"
150
1.5"
150
1.5"
165
2"
165
2"
185
2.5"
185
2.5"
185
2.5"
200
3"
200
3"
AR
4 Holes 18
on PCD 100
4 Holes 17
on PCD 100
4 Holes 18
on PCD 110
4 Holes 18
on PCD 110
4 Holes 18
on PCD 125
4 Holes 18
on PCD 125
4 Holes 18
on PCD 145
4 Holes 18
on PCD 145
4 Holes 18
on PCD 145
8 Holes 18
on PCD 160
8 Holes 18
on PCD 160
HORIZONTAL SPLIT CASE
PUMPS
FEATURES
Performance characteristics as per NFPA 20
Complete unit responsibility.
Complete in-house fabrication capabilities.
Hydrostatic testing facilities.
Operation run test as per NFPA 20, UL 448 and
FM 1311 requirements.
Horizontal Split case pumps for capacities from 750
to 1500 US GPM.
Drivers: Electric motor drive or diesel engine drive.
Electrical testing capabilities for motors and
controllers as per NFPA standards.
Capable of supplying additional accessories wherever
required.
Approved Fire Pump Models with Ratings
RATED CAPACITY - 750 US GPM
Sl. No.
Pump Model
1
2
3
NF-S-125-80
NF-S-150-100
NF-S-150-100-375
UL Listed
Pressure (PSI)
236
FM Approved
Pressure (PSI)
236
Rated Speed
(RPM)
2900
Suction Inlet
Dia. (Inch)
5
Discharge Outlet
Dia. (Inch)
3
112 - 213
226 - 276
108 - 216
227 - 280
2900
2900
6
6
4
4
Stage(s)
1
1
1
RATED CAPACITY - 1000 US GPM
Sl. No.
Pump Model
1
2
3
NF-S-150-100
NF-S-150-100-375
NF-S-200-125
UL Listed
Pressure (PSI)
101 - 208
FM Approved
Pressure (PSI)
101 - 215
Rated Speed
(RPM)
2900
Suction Inlet
Dia. (Inch)
6
Discharge Outlet
Dia. (Inch)
4
219 - 273
143 - 267
215 - 273
143 - 252
2900
2900
6
8
4
5
Stage(s)
1
1
1
RATED CAPACITY - 1250 US GPM
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
NF-S-200-125
137 - 263
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
134- 250
2900
RATED CAPACITY - 1500 US GPM
Sl. No.
Pump Model
UL Listed
Pressure (PSI)
FM Approved
Pressure (PSI)
Rated Speed
(RPM)
Suction Inlet
Dia. (Inch)
Discharge Outlet
Dia. (Inch)
Stage(s)
NF-S-200-125
130 - 256
121- 242
2900
www.naffco.com
OPEN VIEW
PUMP CASING: The casing is axially split, which
permits removal of the complete rotor without moving
either piping or motor. Pumps generating high heads
have double volutes to reduce radial forces, ensuring
minimal shaft deflection and low bearing loads.
Replaceable wear rings protect the casing at the
impeller running clearances.
IMPELLER: The closed impeller has double curved
vanes. The double suction design gives practically
zero axial forces. Each impeller is dynamically
balanced according to ISO 1940-1 standard.
BEARINGS: Grease lubricated deep groove ball
bearings are provided on both sides.
SHAFT SEAL: Soft-packed stuffing box. Cooling lines
are provided for additional cooling of the graphite
impregnated type gland packing.
PUMP MODEL NAME ILLUSTRATION
NF
.........................
Series Name
..........................
Split Case
150
.........................
Suction Size (mm)
100
.........................
Discharge Size (mm)
DESCRIPTION
No.
Part Name
Material
Qty.
Lower Casing
Cast Iron ASTM A48 Class 40
Upper Casing
Cast Iron ASTM A48 Class 40
Impeller
Bronze SAE 40
Shaft Sleeve
Stainless Steel AISI 420
Bearing Cover
Cast Iron ASTM A48 Class 40
Gland
Bronze SAE 40
Stuffing Box
Cast Iron ASTM A48 Class 40
Shaft
Alloy Steel AISI 4340
Wear Ring
Bronze SAE 40
10
Flushing Pipe
Stainless Steel, Gr. 304
11
Coupling Key
Stainless Steel AISI 420
12
Gland Packing
Graphite Impregnated
13
Lantern Ring
Bronze SAE 40
14
Bearing Housing
Cast Iron ASTM A48 Class 40
www.naffco.com
DIMENSIONAL DRAWING
Standard
- ASME B16.1
Class Rating - Class 250
TABLE OF DIMENSIONS
Suction Flange
Model
AA
AB
AC
AD
AE
BA
Discharge Flange
BB
AW
AT
AS
AQ
AO
AR
NF-S-125-80
330
330
340
306
315
270
175
280
5"
8 holes 22
on PCD 235
210
3"
8 holes 22
on PCD 168
NF-S-150-100
330
330
400
267
355
270
185
320
6"
12 holes 22
on PCD 270
255
4"
8 holes 22
on PCD 200
NF-S-150-100-375
375
375
400
340
355
270
185
320
6"
12 holes 22
on PCD 270
255
4"
8 holes 22
on PCD 200
NF-S-200-125
395
370
450
367
400
340
200
380
8"
12 holes 28
on PCD 330
280
5"
8 holes 22
on PCD 235
www.naffco.com
10
www.naffco.com
GENERAL ARRANGEMENT DRAWING
FOR FIRE PUMPS
Suction Pressure Gauge
Discharge Pressure Gauge
Casing Relief Valve (Electric Pump)
Automatic Air Release Valve
NRV with 3/32 Hole
Ball Valve (Threaded)
2
3
4
5
6
Description
No.
FIRE PUMP INSTALLATION
www.naffco.com
11
NAFFCO FZCO
World Headquarters
Dubai, United Arab Emirates
Email: [email protected]
www.naffco.com
In line with NAFFCO policy for continuous product development,
NAFFCO has the right to change specifications without prior notice.
CAT.NO.NF/ULFP2900/01/15
Serving Over 100
100
00 Countries
C
Co
Cou
ou
oun
unt
ntr
ntri
ntrie
trie
ries
ies
ess Worldwide
W
Wo
Wor
Worl
orld
rld
rldw
ldw
dw
dwi
dwid
wid
wide
de
e