0% found this document useful (0 votes)
125 views1 page

Perfect Welding / Solar Energy / Perfect Charging

This document provides details on a proposed 4,000 kWh annual solar energy project in Bosnia and Herzegowina. It includes specifications for the PV modules, inverters, and solar array, with the array consisting of one string with 21 Luxor Solar LX-250P modules producing 5.25 kWp and one string with 19 modules producing 4.75 kWp for a total output of 10 kWp. The Symo 10.0-3-M inverter is specified with an operating ratio of 98%.

Uploaded by

AmarK90
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
125 views1 page

Perfect Welding / Solar Energy / Perfect Charging

This document provides details on a proposed 4,000 kWh annual solar energy project in Bosnia and Herzegowina. It includes specifications for the PV modules, inverters, and solar array, with the array consisting of one string with 21 Luxor Solar LX-250P modules producing 5.25 kWp and one string with 19 modules producing 4.75 kWp for a total output of 10 kWp. The Symo 10.0-3-M inverter is specified with an operating ratio of 98%.

Uploaded by

AmarK90
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

/ Perfect Welding / Solar Energy / Perfect Charging

PROJECT
Country Bosnia and Herzegowina
Project name 2017-04-11_0908
Annual power consumption 4,000 kWh
Load profile Working

PV MODULE
Modul manufacturer Luxor Solar GmbH
Model LX-250P
Min. / Max. module temperature -10C / 70C

INVERTER
Inverter type Symo 10.0-3-M
Min. / Max. inverter ratio 80% / 120%

SUMMARY
Inverter ratio 98%
Pmpp STC 10.00 kWp
MPPT A 1x21
MPPT B 1x19

MPPT A / B DETAILS
String (str. x mod.) 1 x 21 / 1 x 19
Isc STC 8.61 A / 8.61 A
Umpp at 70 C 534.30 V / 483.42 V
Uoc at -10 C 873.60 V / 790.40 V
Umpp at STC 647.43 V / 585.77 V
Pmpp at STC 5.25 kWp / 4.75 kWp

FRONIUS International GmbH accepts no guarantee for the completeness of the module and inverter data used or any false
configurations created by the configurator, or faulty or inefficient system sizing. All liability claims against Fronius relating to damages of a material or conceptual type
which were caused through the use of the Solar.configurator are basically excluded unless there is any dmonstrably deliberate or grossly negligent
fault on the part of Fronius.
The Quick sizing is based on the following assumptions: No country-specific consideration of cosPhi, AC voltage, unbalanced loading or capacity limitation.
Place of installation < 2000m. Specific yield for storage calculation = 1000 kWh/kWp. 1/1