Table 3.4 — Nominal cover to all reinforcement (including links) to meet specified periods of fire resistance (see NOTES 1 and 2) Fire registance Nominal cover Beams" Floors Ribs ‘Columns Simply | Continuous | Simply | Continuous | Simply | Continuous | supported mm supported mim supported mm 05 20° 20° 20° 20° 20° 20° 20° 1 20° 20% 20 20 20 20° 20° 16 20 20° 25 20 35 20 20 2 40 30 35 25 rey 35 5 3 60 40 a5 36 56 5 4 70 50 55 5 65 55 NOTE1 The nominal covers given relate specifically to the minimum member dimensions given in Figure 8.2, Guidance on inereased covers necessary if smaller members ave used is given in section 4 of BS 8110-2: 1986. NOTE 2. Cases that lie below the bold line vequive attention to the additional measures necessary to reduce the risks of spalling (see section 4 of BS 8110-2:1985). ® For the purposes of assessing a nominal cover for beams and columns, the cover to main bars whieh would have been obtained from Tables 4.2 and 4.3 of BS 8110-2:1985 has been reduced by a notional allowance for stirrups of 10 mm to cover the range 8 mm to 12 mm (see also 3.3.6), » These covers may be reduced to 15 mm provided that the nominal maximum size of aggregate does not exceed 15 mm (ee 8.8.1.8)

You might also like