PUBLISHED BY

World's largest Science,


Technology & Medicine
Open Access book publisher

100,000+
2,900+ INTERNATIONAL 94+ MILLION
OPEN ACCESS BOOKS AUTHORS AND EDITORS DOWNLOADS

AUTHORS AMONG
BOOKS TOP 1% 12.2%
DELIVERED TO AUTHORS AND EDITORS
MOST CITED SCIENTIST FROM TOP 500 UNIVERSITIES
151 COUNTRIES

Selection of our books indexed in the


Book Citation Index in Web of Science
Core Collection (BKCI)

Chapter from the book Evolution of Ionizing Radiation Research


Downloaded from: http://www.intechopen.com/books/evolution-of-ionizing-radiation-
research

Interested in publishing with InTechOpen?


Contact us at [email protected]
Chapter 8

Ionizing Radiation Detectors

Marcia Dutra R. Silva

Additional information is available at the end of the chapter

http://dx.doi.org/10.5772/60914

Abstract

Ionizing radiation has always been present in the natural environment. However, this
radiation is not easily detected and since it also possesses high ionizing power and
penetration strength, it constitutes a risk to human health when it is found outside of
its acceptable limits. The adverse effects of ionizing radiation on human health need
to be systematically monitored in order to prevent damage, overexposure, or even
death. The detection of the radiation depends on its particular interaction with a
sensitive material, and different types of detectors, in different physical states (solid,
liquid or gas), are used to measure selective types of ionizing radiation. New materials
such as organic semiconductors, for instance, are being targeted for research and as
potential candidates for new perspectives on ionizing radiation sensing.

Keywords: Radiation, high energy, detector

1. Introduction

Ionizing radiation has always been present in the natural environment. Sources of ionizing
radiation are commonly found in water, air, soil, or manmade devices. However, ionizing
radiation is situated in the electromagnetic spectrum outside the region of perception of the
human eye - visible region - and it has no smell. Thus, it cannot be detected by the human
senses. Since the ionizing radiation is not easily detected and it also possesses high ionizing
power and penetration strength, it constitutes a risk to human health when it is found outside
of its acceptable limits. The adverse effects of ionizing radiation on human health need to be
systematically monitored in order to prevent damage, overexposure, or even death. The ability
to identify sources of radiation, specific radioisotopes, and measure quantities of radiation is

2015 The Author(s). Licensee InTech. This chapter is distributed under the terms of the Creative Commons
Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution,
and reproduction in any medium, provided the original work is properly cited.
190 Evolution of Ionizing Radiation Research

crucial to environmental monitoring, radiation protection, and development of security


programs.

Ionizing radiation cannot be directly measured. The detection is done indirectly using an
ionizing radiation sensitive material, which constitutes the basis when developing sensors or
detectors of radiation. However, there is not a radiation detector that can measure all types of
radiation efficiently. The interaction of radiation with matter depends on the nature of the
radiation: the electromagnetic radiation, light charged particles, neutrons, or heavy charged
particles. Therefore, a detector which efficiently measures a particular kind of radiation could
be completely inappropriate for others. The nature of the sensitive materials response to the
ionizing radiation and its energy range to be measured will determine the type of detector.

When the ionizing radiation interacts with a sensitive material constituting the detector device,
it generates a signal, which can be a pulse, hole, light signal, and many others [1]. The detection
of the radiation depends on the particular interactions with the sensitive material, and there
are three main and well-established possibilities to relate and categorize the induced radiation
with the generated signal in the detector, as shown below:
i. The generated signal from the incident radiation is created by the counting of the
number of interactions occurring at the sensitive volume of the detector. In this case,
the detector is called counter.

ii. The incident radiation generates a signal that measures the energy that has reached
the detector. The detector is named spectrometer.

iii. The detector measures the average energy incident on a specific point of the sensitive
volume, that is, the absorbed radiation dose. Such detectors are known as dosimeters.
A priori or a posteriori application of ionizing radiation detector will indicate which type is more
suitable to use for a specific measurement. To measure the radiation in real time, as in the case
of evaluating the average radiation of a given location, direct-read instruments such as gas
detectors, scintillation detectors, or semiconductor detectors are used. In order to measure the
radiation to which a person is exposed, detectors that can be further processed such as
photographic emulsions and thermoluminescent dosimeters are used.

Radiation detectors have to two key principles: (i) ionization and (ii) excitation. In ionization-
based detectors, electron-ion pairs are generated by enough energy when ionizing radiation
reaches atoms of a sensitive material and removes orbital electrons (Figure 1).

Figure 1. Ionization Process.


Ionizing Radiation Detectors 191
http://dx.doi.org/10.5772/60914

In excitation-based detectors, bounded electrons are raised to an excited state in the atom or
molecule when part of the radiation energy is transferred to them (Figure 2). The electron
excited to these states returns to its ground state emitting light in the UV-Visible region.

Figure 2. Excitation process.

2. Detectors

2.1. Gas-filled detectors

When a high-energy radiation passes through a medium, it undergoes ionization and releases
charges that depend on the excitation radiation energy. In gas detectors, the ionization appears
as electron-ion pairs and these charge carriers can be attracted and collected by electrodes [2-4].

In gases, ionized particles can travel more freely than in a liquid or a solid. Therefore, in gas
counters the space between the electrodes is filled with a gas and when a voltage is applied an
electric field is created by the potential difference between the electrodes. Electrons and
positively charged gas atom of each ion pair accelerate to anode and cathode, respectively,
resulting in an electric signal (current) in the circuit that can be correlated to radiation exposure
and displayed as a value (Figure 3).

Figure 3. Current mode.


192 Evolution of Ionizing Radiation Research

Another detection possibility is to acquire the incident radiation signal through pulses (pulse
counting mode). In this case, the number of ion-electron pairs generated corresponds to the
intensity of the detected pulse (Figure 4). The ionization chamber, proportional counters, and
Geiger-Muller counters are examples of gas detectors. Typically, ionization chambers are used
in the current mode while proportional counters and Geiger-Muller use the pulse mode to
measure the radiation.

Figure 4. Pulse mode counting.

The average energy W required to produce an electron-ion pair varies (20-45eV) depending
on the gas used. The average energy W can be expressed as [5]:

Ei
W= (1)
N

where Ei is the energy deposited by the incident radiation and N the average number of
electron-ion pairs formed.

The number of ion pairs generated varies according to the applied voltage for constant incident
radiation. The voltages can vary widely depending upon the detector geometry and the gas
type and pressure. The different voltage regions are indicated schematically in Figure 5. There
are six main practical operating regions, where three are useful to detect ionizing radiation.

Region (1): At low voltage, the electric field is not large enough to accelerate electrons and
ions. Then, many electrons and ions produced in gas recombine before they reach the electro
des and they are not collected. In this area, the size pulse increases as applied voltage increases,
and the recombination rate decreases to the point where it becomes zero. This first region is
called recombination and is not useful for counting radiation.

Region (2): In the ionization region, the voltage is high enough and each ion pair generated
reaches the electrodes. However, the number of the ion pairs does not change when voltage
is increased and the curve is flat. Then, the number of ion pairs produced by the radiation is
nearly equal to the number of ion pairs collected by the electrodes because there is no recom
Ionizing Radiation Detectors 193
http://dx.doi.org/10.5772/60914

Figure 5. Six-region curve for gas-filled detectors.

bination and the voltage is not high enough to produce gas amplification. The ionization
chambers work in this region.

Region (3): In the proportional region, there is a gas amplification that causes more ion pairs
to reach the electrodes than ion pairs are initially produced by radiation. The electrons from
the primary ionization acquire enough energy between collisions to produce additional
ionizations due to strong electric field. These secondary ions formed are also accelerated
causing an effect known as Townsend avalanches, which creates a single large electrical pulse.

Primary ionization

X + p = X+ + p + e-

Secondary ionization

X + e- = X+ + e- + e-

where X is the gas atom, p is the charge particle traversing the gas, and e is the electron.

The number of ion pairs collected divided by the number of ion pairs produced by the primary
ionization provides the gas amplification factor. For example, if 50, 000 ion pairs are collected
and 10, 000 ion pairs were initially produced, the gas amplification factor is 5. The gas
amplification factor varies according to the applied voltage across the electrodes and it also
varies with the geometry of the detector. However, it is constant at a specific voltage and for
194 Evolution of Ionizing Radiation Research

any kind of radiation or energy of radiation. Then, if a voltage increases the gas amplification
factor increases proportionally, but if a voltage remains constant the gas amplification factor
also does not change. Because of this amplification process, proportional counters are ex
tremely sensitive (<10KeV) while ionization chambers are limited by discriminate particles of
>10 keV energy.

The pulse height depends on the detected particle energy. Therefore, different energies of
radiation can be distinguished by analyzing the pulse height. For instance, the size pulse from
an alpha particle, for a fixed applied voltage, will be larger than the signal from a beta particle.
Thus, particle identification and energy measurement are possible by using proportional
counters.

Region (4): In the limited proportional region, the gas amplification factor is not constant for
a given voltage setting and there is no proportionality of the output signal to the deposited
energy at a given applied voltage. Additional avalanches occur, leading to additional ioniza
tions and nonlinear effects take place. The nonlinearities observed are due to the high positive
ion concentration, which leads to distortion in the electric field. Free electrons due to their high
mobility are quickly collected by the electrodes while positive ions are slowly moving. Then,
clouds of positive ions are created near the electrode, leading to distortions in gas multiplica
tion. This region is usually avoided as a detection region.

Region (5): At high voltages, the electric field is so strong that avalanches of electron-ion pairs
are produced and reach the electrodes. A strong signal is produced by these avalanches with
shape and height independently of the primary ionization and the energy of the detected
photon. This region is called the Geiger-Muller region, and the large output pulse is the same
for all photons. Therefore, the energy or even incident radiation particle cannot not be
distinguished by GM detectors.

Region (6): At still higher voltages (above GM region), the electric field strength is so intense
that it itself produces ionization in the gas and completes avalanching. Continuous electric
discharges occur between the electrodes and the detectors that operate in this region can be
damaged. Therefore, no practical detection of radiation is possible.

2.2. Scintillation detectors

Scintillators are materials that exhibit luminescence when excited with ionizing radiation. The
scintillation mechanism can be explained by means of the energy-band theory. In this model,
a band gap separates the valence band (filled band) of conduction band (usually empty). Thus,
via the ionization process, an electron can be excited from the valence band to the conduction
band or to the energy states located close to the mid-gap (impurities). An exciton is formed
when the electron removed remains electrostatically bonded with the hole left in the valence
band. The electron excited to these states decays to the ground state emitting light in the visible
range of the electromagnetic spectrum [6]. This visible light interacts with the photocathode
and electrons are emitted by photoelectric effect and/or Compton scattering, producing a
current in the circuit. However, scintillation detectors produce currents of low intensity and
only after the advent of photomultiplier tubes has its use become feasible. In this way, the
Ionizing Radiation Detectors 195
http://dx.doi.org/10.5772/60914

electrons emitted by photocathode are multiplied by the dynodes in the photomultiplier tube
and collected in the anode. As a result, a measurable electrical current is acquired. The output
pulse of electrons of a scintillation detector is proportional to the energy of the original
radiation.

A good scintillator material is highly efficient in converting incident radiation energy into light.
The scintillator must also be transparent to its own light emissions and it must have a short
decay time because the transparence is important to a good light transmission to reach the
electrode, and the short decay time allows fast response.

Decay time is the time required for scintillation emission to decrease to e-1 of its maximum and
it can be described as the sum of two exponential components [7, 8]:

w - t
1-w -t
i (t ) = e t0
+ e t1
(2)
t0 t1

where 0 and 1 are the decay time constants of the fast and slow components of a scintillator,
respectively, and is the weight of the fast component.

The fast component is related to the fluorescence and the slow component is related to
phosphorescence or afterglow. These two types of radiative processes (photon emission
processes) are well-established in the literature and they are illustrated by the Perrin-Jablonski
diagram in Figure 6. The fluorescence occurs in the de-excitation process between singlet
electronic states (same spin multiplicity), and it is responsible for the majority of emitting
radiative processes due to short decay time (10-9s). The phosphorescence occurs in de-
excitation process between different multiplicity states (triplet-singlet), in times the order of
10-3s. The singlet states are represented by Sn and triplet states by Tn, where n = 0, 1, 2, 3..., and
n = 0 corresponds to the ground state [8, 9]. Other type of delayed emission is the delayed
fluorescence (DF), which is a reverse intersystem crossing T1->S1, it is induced thermally or
by collisions. Afterglow competes with the scintillation process leading to a decrease of total
efficiency of conversion of ionizing radiation into light, and it should be avoided in scintillation
detectors [10].

Scintillation detectors are composed of two basic types of detector materials: organic and
inorganic. Inorganic scintillators have scintillation properties due to their crystalline structure
or due to activators (impurities), which enable scintillation process. Organic scintillators do
not need crystal structure or activators because each molecule can act as a scintillation center.
The difference in their behavior comes to the different ranges of energy levels excited by the
incident radiation. Inorganic scintillators usually respond more slowly than organic scintilla
tors, but they are more efficient than organic materials for detecting ionizing radiation because
of their greater density and higher average atomic number. However, organic materials are
more flexible and cheaper than inorganic material, leading to numerous scientific efforts to
increase their performance in recent decades.
196 Evolution of Ionizing Radiation Research

Figure 6. Perrin-Jablonski diagram.

Currently, the scintillation detectors have excellent sensitivity to excitation energy and fast
response time. Different types of scintillators, in different physical states (solid, liquid, or gas),
are used to measure selective types of ionizing radiation. They are widely used in medical
applications for image generation (X-rays and tomography), as well as high-energy physics
experiments, plant laboratories, airports security (X-rays machines), and radiation sensing for
nuclear installations.

2.3. Semiconductor detectors

Semiconductors are materials, inorganic or organic, which have the ability to control their
electronic conduction depending on chemical structure, temperature, illumination, and
presence of dopants. The name semiconductor comes from the fact that these materials usually
present an intermediate conductivity between conductors and insulators. Consequently, they
have an energy gap less than 4eV [11]. In solid-state physics, energy gap or band gap is an
energy range between valence band and conduction band where electron states are forbidden.
The valence band is the region where electrons are connected to the lattice atoms. The
conduction band is the region that contains the energy levels where free electrons can move
through the crystal structure [12, 13]. The width of the forbidden energy band is what
categorizes the material as conductor, semiconductor, or insulator (Figure 7).

There are many semiconductors in nature and others synthesized in laboratories; however,
the best known are silicon (Si) and germanium (Ge). Silicon has been considered precursor to
the revolution that has occurred in recent decades in the electronic area. However, germanium
is more used than silicon for radiation detection because the average energy necessary to create
Ionizing Radiation Detectors 197
http://dx.doi.org/10.5772/60914

an electron-hole pair is 3, 6eV for silicon and 2, 6eV for germanium, which provides the latter
a better resolution in energy. In addition, in gamma spectroscopy, germanium is preferred due
to its atomic number being much higher than silicon and which increases the probability of
-ray interaction.

Figure 7. Band structure for electron energies in solids.

In semiconductor detectors, also called solid-state detectors, charge carriers are produced and
collected by electrodes as in ionization chambers. However, the charge carriers are electrons
and holes and not electrons and ions as in ionization chambers. When semiconductor detectors
are subjected to high-energy radiation, electron-hole pairs are produced and converted into
electric current.

The electron mobility in a gas counter is thousands of times greater than that of the ions. In
fact, the electron mobility in semiconductors is roughly equal that of the holes and both types
of carriers contribute to conductivity.

Conductivity is the inverse of resistivity and it is defined by

J =sE (3)

where J is the current density (A/m2), is the conductivity [A/(V.m)], and E is the electric field
(V/m).

Another expression for the current density is:

J = eNv (4)

where N is the number of charge carriers, e is the elementary charge, and v is the speed of
carriers.

The following equation is obtained by using Equations 3 and 4:

v
s = eN (5)
E
198 Evolution of Ionizing Radiation Research

The ratio /E is called carrier mobility :

v
m= (6)
E

The expression for the conductivity becomes:

s = e ( Ne me + Nh mh ) (7)

where Ne and Nh are carrier concentrations and e and h are the mobilities of electrons and
holes, respectively, and according to this equation, the conductivity changes if the mobility of
charge carriers and/or their concentrations change. Thus, both terms in the right-hand side of
Equation 7 contribute to the conduction in semiconductor detectors.

A small energy is required to create an electron-hole pair in semiconductor materials (~3 eV


for germanium) compared to the energy needed to create an electron-ion pair in gases (~30 eV
for typical gas detectors) or to create an electron-hole pair in scintillators (~100eV) [14]. As a
consequence, a great number of electron-hole pairs are produced and reach the electrodes,
increasing the number of pairs per pulse and, then, decreasing both statistical fluctuation and
signal/noise in the preamplifier. This generates a big advantage over other detectors and the
output pulse provides much better energy resolution. Moreover, the small sensitive area used
to detect radiation (few millimeters) and the high speed of charge carriers provide an excellent
charge collection time (~10-7 s).

The energy resolution, R, determines the ability of the system to distinguish two energies that
are very close to each other, and that constitute an important parameter in the spectral detection
of ionizing radiation (Figure 8). It is commonly defined as:

FWHM
R= (8)
H0

where FWHM is the full-width-at-half-maximum and H0 is the peak centroid.

In order for a semiconductor to act as a radiation detector, the active area to radiation must be
free of excess electrical charges (depleted). The depletion region can be formed through the
use of very high purity materials like High Purity germanium (HPGe) or PN junctions. PN
junctions are obtained when an n-type semiconductor (excess of electrons) is placed in contact
with a p-type semiconductor (excess of holes). Then, electrons and holes diffuse from n-region
to p-region and from p-region to n-region, respectively, and they recombine around the
interface. The ions, which are left behind by electrons and holes that were recombined, create
an electric field that will attract more electrons and holes until there is no more charge carriers
to recombine (Figure 9).
Ionizing Radiation Detectors 199
http://dx.doi.org/10.5772/60914

Figure 8. FWHM for a Gaussian distribution. In this case, the FWHM results related to the as FWHM = 2.35 .

At this moment, if the ionizing radiation interacts with the semiconductor in this depleted
region, electrons are raised to the conduction band leaving behind holes in the valence band
and producing a large number of electron-hole pairs. If a voltage is applied across the semi
conductor, these carriers are readily attracted to the electrodes and current flows into circuit
resulting in a pulse. The size of the pulse is directly proportional to the number of carriers
collected, which is proportional to the energy deposited in the material by the incident
radiation.

Figure 9. PN junction.

In semiconductors, if the temperature increases, electrons can be thermally excited from the
valence band to the conduction band. Consequently, some semiconductor detectors must be
cooled so as to reduce the number of electron-hole pairs in the crystal in the absence of
radiation. Although solid-state detectors can be manufactured much smaller size than those
of equivalent gas-filled detectors and they have short response time, seconds compared to the
200 Evolution of Ionizing Radiation Research

hours of TLD detectors, they are still expensive because they need to be cooled. Thus, they are
used when higher resolution is required; if higher efficiency is necessary, scintillation detectors
are used.

Different semiconductor materials and device arrangements are used, depending on the type
of radiation to be measured and the aim of application. The types of radiation that can be
measured with semiconductor detectors comprise a large range of the electromagnetic
spectrum: <1 eV to ~10 MeV for photons and energies above keV for charged particles.
Commonly, semiconductor detectors are employed for beta particles or gamma radiation
because the heavy charged particles cause more radiation damage. They are widely used in
nuclear power station electronic dosimeters and portable survey instruments in gamma
spectroscopy systems.

2.4. Thermoluminescent dosimeters

The amount of radiation absorbed by the human body can be determined through radiation
dosimetry. A dosimeter has to correlate the absorbed radiation with biological effects induced
in humans. The physical quantity that quantifies this relationship is called absorbed dose. The
absorbed dose, D, of any ionizing radiation can be considered as the amount of energy given
to the medium by ionizing particles or photons per unit of mass dm [2, 14, 15]:

d
D= (9)
dm

where d is the average energy deposited by the radiation on a point P.

The SI unit of absorbed dose is the Gray (Gy), defined as: 1Gy = 1 J/kg. The obsolete units for
dose are the rad (radiation absorbed dose) and the centigray (cGy): 1rad = 10-2 J/kg = 1cGy.

Thermoluminescent dosimeters (TLDs) are the foremost used devices for personal dosimetry.
They are composed of crystal devices that emit light when are heated. The TLD reading device
is able to calculate the amount of light released during heating, which can then be correlated
with the absorbed dose received and stored by the TLD dosimeter.

A useful model of the thermoluminescence mechanism is provided in terms of the band model
for solids. Thus, when a thermoluminescent crystal is exposed to ionizing radiation, electrons
are quickly promoted to their conduction band through direct excitation process. However,
some electrons are trapped by metastable states and when the material is subjected to thermal
stimulation, they have enough energy to leave the trap states and recombine with holes that
were left in the valence band. The excess of energy in this process is conserved by radiative
deactivations emitting light, which is proportional to the absorbed ionized dose [16].

Figure 10 shows a model of energy bands with electronic transitions in thermoluminescence


process.
Ionizing Radiation Detectors 201
http://dx.doi.org/10.5772/60914

Figure 10. Model of energy bands in thermoluminescence process. (a) excitation and generation of electron-hole pair,
(b) trapping, (c) de-trapping by thermal stimulation, (d) recombination. T is the center of the trap, R is the recombina
tion center, EF is the Fermi level, and Eg is the bandgap.

The heating of the TLD dosimeter to assess the accumulated radiation dose is done in tem
perature ramps and each temperature value is associated with a value of the light intensity
(Figure 11). Thus, through thermoluminescence photons emission it is feasible to establish a
curve of thermoluminescence intensity versus temperature that is called TL glow curve. The
area under the TL glow curve is directly proportional to the number of emitted photons and,
thereby, proportional to radiation dose received.

Figure 11. TL glow curve of LiF:Mg, Ti measured with a TLD reader at a low heating rate.

Thermoluminescent crystals possess good levels of deeper traps that require greater thermal
energy to release the carrier, thus they can accumulate energy for a longer period of time. Many
materials are purposely doped to create impurity levels; others such as LiF (lithium fluoride)
already have natural impurities and intrinsic defects. Other substances are used as materials
for thermoluminescent dosimetry, for example, CaSO4:Dy (calcium sulfate doped with
dysprosium); the CaSO4:Mn (calcium sulfate doped with manganese); and CaF2 (fluorite).
202 Evolution of Ionizing Radiation Research

A thermoluminescent crystal can be used as dosimeter only if it presents high emission


efficiency, good stability on temperature ranges of work, high resistance to environmental
variations and linear radiation dose-response.

The principal advantages of TLD dosimeters are:


High sensitivity over a wide dosage range.

Small and varied forms.

Can be used several times.

They are equivalent to human tissues.

They have high degree of accuracy and precision in the measurements.


Among the disadvantages are:
Infeasibility of rereading.

The necessary instrumentation for the measurement has high cost.

Sensitivity varies with the time after irradiation.

Readings and the results are not immediate.

They present fading for sensitivity to light and moisture.

2.5. Chemical detectors

In chemical dosimetry, the ionizing radiation produces chemical changes in the medium that
can be measured by using a suitable measuring system. Oxidation, reduction, and chemical
dissociation are the principal mechanisms of chemical detectors.

The intensity of these changes is characterized by radiation chemical yield (G), which is defined
as a number of molecules, ions, atoms, or free radicals of product or dissolved reaction
components for 100 eV of absorbed energy, or even defined as the mean number of moles
produced/destroyed by mean energy transmitted to the matter [2]:

n
G= (10)
E

is the mean transmitted energy. G SI unit is mol.J-1.


where n is the mean moles number and E

The most widely used chemical dosimetry standard is the Fricke dosimeter. The Fricke
dosimetry system provides a reliable means for measurement of absorbed dose to water by
ferrous ions oxidation. The dosimeter consists of a solution with 1 mmol/l ferrous sulfate (or
ferrous ammonium sulfate), 1 mol/l NaCl, and 0.4 mol/l sulfuric acid. When the Frick solution
is irradiated, the ferrous ions, Fe2+, are oxidized by radiation to ferric ions, Fe3+ [17]. The ferric
ion concentration is determined by spectrophotometry, which measures absorption peaks at
Ionizing Radiation Detectors 203
http://dx.doi.org/10.5772/60914

wavelengths of 224 nm and 304 nm. In this case, G-value is defined as the number of moles of
ferric ions produced per joule of the energy absorbed in the solution. The usual range of the
Fricke dosimeter is from 30Gy to 400 Gy.

2.6. Calorimetric detectors

Calorimetric methods measure the dose of radiation by measuring the temperature increase
in a medium. Although the basic principles of calorimeters are very simple, they have technical
problems to ionizing radiation sensing and they have been viewed as complex to make and
operate [18]. Small temperature response to low dose of radiation and necessity of extremely
thermic isolation are some problems of this type of detector. Therefore, few laboratories use
these detectors; however, efforts have been made in order to increase their performance.

2.7. New materials to ionizing radiation sensing

Despite the well-established known techniques and detectors for ionizing radiation, the field
still has a lack of new materials and sensor devices. The use of ionizing radiation in industrial
processes, in clinics, hospitals, universities, and research centers has increased considerably
and consistently in the past few years. In addition, the inspection and monitoring of aircrews
is a current concern and should be mandatory to all flights in the near future. Thus, the
development of new materials sensitive to ionizing radiation and robust devices, faster and
more accurate, is of crucial importance to this research field and its direct applications.

In the last two decades, there was an effort to combine the energy sensitivity found in
semiconductor devices with the low cost and flexibility of organic semiconductor-based
conjugated polymers. In this fashion, oligomers and polymers such as PPV (poly p-phenylene
vinylene) [19], MEHPPV (poly (2-methoxy, 5- (2 -ethyl-hexoxy) -p-phenylene vinylene) [20,
21], P3HT (poly 3-hexylthiophene) [22, 23], and pentacene [24] have become the target of
research and are potential candidates for new perspectives to ionizing radiation sensing. Use
of these materials, which have known properties and have been studied, have played an
important role in the study of ionizing radiation effects on polymers (Figure 12).

In the interaction of high-energy radiation with semiconductors, primarily there occur


excitations and ionizations that generate ions and electrons. The electrons generated (primary
electrons) will interact again with the environment and generate secondary excitations that
will produce electron-hole pairs. Therefore, the efficiency of the material with the highly
energetic radiation will depend on its stopping power or absorption efficiency, the limited
capacity of producing electron traps and its ability to grow large areas. Semiconductor
polymers generally have high efficiency luminescence and absorption in the UV-Vis region;
they can also form films producing large areas, and, hence, they constitute a new alternative
in the area of radiation detectors.

In the field of electromagnetic radiation, there are several possible interactions of the most
energetic radiation with matter: mainly, the photoelectric effect, Rayleigh scattering, Compton
effect, and production of electron-positron pairs. Eventually, these interactions can lead to
temporary or permanent modifications. These changes are called effects of degradation. They
204 Evolution of Ionizing Radiation Research

Figure 12. Chemical structure of polymers: (a) PPV (b) MEHPPV (c) P3HT and (d) pentacene.

may be superficial when there is change only in the physical appearance (color, transparency,
etc.) or they may be structural.

Polymer degradation effects have been reported such as scission [25], cross-linking [26, 27],
and photobleaching [28]. In scission, there occurs break of the main chain into smaller
molecules, reducing its molecular weight. In cross-linking, due to link between two polymer
chains or between two big radicals, there is a formation of an insoluble portion with increasing
molecular weight. Decrease in viscosity and increase of ductility are effects of scission. Increase
of hardness, viscosity, and brittleness are some of the macroscopic effects of cross-linking.
Photobleaching occurs when the fluorescent signal of a fluorophore disappears permanently
due to photon-induced chemical damage and covalent modification.

Degradation effects are often considered problems such as the oxidation effects of medical
implants based on polyethylene after irradiation sterilization, for example[29]. However, the
ionizing radiation degradation effects are not sometimes bad results. Many times they are
desirable, as in the creation of integrated circuits, decreasing the molecular weight to make a
material compatible with the other, in polysaccharides, for use in health care products,
cosmetics, textile and food industry, or even to increase viscosity or resistance materials, for
instance [30-32].

Polymer interaction with gamma radiation has been studied since the 1970s and different
effects have been observed depending on the chemical structure of the polymer and the energy
range used for irradiation process. The mechanisms involved in the interaction of gamma
radiation with polymers have not been fully elucidated, but changes in conductivity and
optical properties have been reported mainly in polyaniline [33] and on PPV and its deriva
tives. The results indicate the feasibility of using semiconductor polymers as gamma radiation
detectors.
Ionizing Radiation Detectors 205
http://dx.doi.org/10.5772/60914

The interest in the use of conductive polymers in this area is due to the adjustability of its
luminescence properties and conductivity, and they also have a lower cost than inorganic
semiconductors. However, the use of polymers as radiation sensors is recent and few studies
are reported in the literature. Among them, the highlighting results are P3HT as the active
layer of OLEDs and OFETs for sensing radiation [20], and the MEH-PPV in halogenated
solutions for detection of low doses of gamma radiation.

Studies using MEH-PPV have demonstrated that the use of solutions is effectively more
sensitive to gamma radiation than solid state. Current knowledge shows that polymeric
materials are more sensitive to gamma radiation when solubilized in halogenated solvents
[34]. The halogens are well-known to have large cross section for interaction with gamma
radiation.

The main results obtained on irradiated P3HT devices were a significant improvement in
conductivity with increasing gamma irradiation dose. Polythiophenes irradiated with gamma
radiation go to a polaronic state and then stabilized for a bipolaronic and neutral state of the
chain, where they remain in the oxidized state. Undoubtedly, the result enables the P3HT as
radiation sensor and it leads to a great leap regarding the use of OLEDs and OFETs devices in
the space area. However, the order of radiation dose used on P3HT (kGy) is very high for using
in personal dosimetry (order of ten grays), for example.

In contrast, studies of MEH-PPV with gamma radiation at this order of dose have shown
significant results compatible with personal dosimetry area. However, the results were limited
to the use of the polymer in solution, due to the effect being dependent on the solvent. In other
words, the effect is indirect: the radiation breaks the solvent chain and the radicals derived
from solvent attack break the polymer chain. The attack occurs at the vinylene, breaking the
double bond and leading to the conjugation break displayed as blue shift in optical measure
ments. This experimental result has been corroborated by theoretical studies and the attack
mechanism on vinylene is well-established [35]. Figure 13 shows MEHPPV after ionizing
radiation interaction.

Figure 13. MEHPPV nonirradiated (0Gy) and irradiated at 30, 60, and 90Gy doses of gamma radiation.

The principal disadvantage of MEH-PPV in the interaction with the gamma radiation is its
limitation of use in optoelectronic devices due to the effect of this range of dose not included
the utilization in film. Moreover, with the breaking of the chain and the conjugation length,
206 Evolution of Ionizing Radiation Research

the MEH-PPV has not sufficient extension of conjugation for a good conduction of electrons
and neither has any chain doping as P3HT, which is also a limiting factor for their use in
optoelectronic devices. Thus, its use is limited as optical sensor radiation in solution and can
not be reused. Recalling that, despite limited use, this type of sensor provided an important
advance due to measurement method be cheaper and affordable than other types of detectors.
Semiconductor detectors based in conjugated polymers do not need be cooled, the instrumen
tation used for reading is simple, and polymers are cheaper and easier to process.

3. Applications

In short, a radiation detector is a device used to track, detect, or identify high-energy particles
or radiation from natural or artificial sources such as cosmic radiation, nuclear decay, particle
accelerators, and X-rays.

Since it is not possible for a single detector to measure all types of radiation efficiently, various
types of detectors made of different materials are used in the sensing of specific types of
radiation. The main types of radiation detectors and applications are summarized in Table 1.

Instrument Types Detection Principle Applications


Ionization of air or other gases Direct measurement of exposure or exposure
(ionization chambers). rates.
Detection of individual events, i.e., alpha or beta
Gas-filled detectors Ionization of gas with multiplication
particles and secondary electrons, for measuring
of electrons in detector (proportional
activity (in samples or on surfaces); detecting low
counters and Geiger-Muller).
intensities of X-rays or gamma radiation.
Photons; energy spectrometry; e.g., NaI (Tl).
Light emission (solids).
Alpha particles; detection only (ZnS (Ag)).
Scintillators Detection of low-energy gamma and beta
Light emission (liquid). emitters, for measuring activity (in low-activity
sources).
Detection of individual events (alpha and beta
particles); e.g., diodes and silicon barrier
detectors.
Semiconductor detectors Ionization, excitation. Detection and energy measurement of photons or
particles; primarily for laboratory use; gamma
spectroscopy; X-rays; dosimeters; e.g.,
Germanium detectors.
Thermoluminescent detector Excitation of crystal; light release by
Personal and environmental exposure monitoring.
(TLD) heating.
Photographic film Ionization of Ag Br. Personal exposure monitoring.

Table 1. Instrument types and its applications.


Ionizing Radiation Detectors 207
http://dx.doi.org/10.5772/60914

Despite the variety of sensor devices, the demand for new materials that can detect ionizing
radiation efficiently and at as low a cost as possible is essential to the development of this area.
In this context, many other materials like polymeric semiconductors, for instance, have been
target of research in the last years (section 2). They constitute promising materials for radiation
sensing, although no polymeric device for radiation detection is still available for practical use
at a large scale.
Unfortunately, the field lacks new sensor devices that are more practical, fast, and accurate for
the maintenance and safety of human life in the natural environment as well as in the complex
areas of modern civilization.

Author details

Marcia Dutra R. Silva

Address all correspondence to: [email protected]

Materials Spectroscopy Group - GEM, Physics Institute - INFIS, Federal University of Uber
landia - UFU, Brazil

References

[1] Tsoulfanidis N. Measurement and Detection of radiation. 2nd ed. Francis T&, editor.
1995. p. 614.

[2] Khan FM. The Physics of Radiation Therapy. Lippincott Williams & Wilkins; 2012. p.
592.

[3] Dendy PP, Heaton B. Physics for Diagnostic Radiology. CRC Press; 2011. p. 695.

[4] Attix FH, Rogers DWO. Introduction to Radiological Physics and Radiation Dosime
try. Med. Phys. 1987. p. 692.

[5] Simon Wedlund C, Gronoff G, Lilensten J, Mnager H, Barthlemy M. Comprehen


sive calculation of the energy per ion pair or W values for five major planetary upper
atmospheres. Ann. Geophys. 2011;29:187-195.

[6] Price WJ. Nuclear Radiation Detection. Mac Gray-Hill, editor. 1958. p. 382.

[7] Zhong W-L, Li Z-H, Yang C-G, Cao J. Measurement of decay time of liquid scintilla
tor. Nucl. Instruments Methods Phys. Res. Sect. A Accel. Spectrometers, Detect. As
soc. Equip. 2008;587:300-303.

[8] Valeur B. Molecular Fluorescence Principles and Applications. Weinheim: Wiley-


VCH; 2001. p. 381.
208 Evolution of Ionizing Radiation Research

[9] Condon EU. On the Theory of Intensity Distribution in Band Systems. Berkeley: Uni
versity of California, Berkeley; 1926. p. 78.

[10] Rodnyi PA. Physical Processes in Inorganic Scintillators. CRC Press 1997, editor. Tay
lor & Francis; 1997. p. 240.

[11] Yu PY, Cardona M. Fundamentals of Semiconductors. 1999. p. 617.

[12] Ashcroft NW, Mermin ND. Solid state physics. Saunders College; 1976. p. 826.

[13] Kittel C. Introduction to solid state physics. 5 ed. Wiley; 1976. p. 599.

[14] Knoll GF. Radiation Detection and Measurement. 3rd ed. Wiley, editor. 2010. p. 860.

[15] (2007) I. The 2007 Recommendations of ICRP. Ann. ICRP 37(2-4), ICRP Publ. 103.

[16] Horowitz YS. Thermoluminescence and thermoluminescent dosimetry. Horowitz YS,


editor. Florida: CRC Press; 1984.

[17] Frick H, Hart EJ. Chemical Dosimetry. In: Attix FH, Roesch WC, editors. Radiat. Dos
im. II. New York: Academic Press; 1966. p. 167-239.

[18] Kase KR, Bjrngard BE, Attix FH. The Dosimetry of Ionizing Radiation. Academic
Press; 1985. p. 384.

[19] Silva MDR, Ganalves AA, Silva R a., Marletta A. Gamma radiation effects on ab
sorbance and emission properties of layer-by-layer PPV/DBS films. J. Non. Cryst. Sol
ids. Elsevier B.V.; 2010;356:2429-2432.

[20] Raval HN, Tiwari SP, Navan RR, Rao VR. Determining ionizing radiation using sen
sors based on organic semiconducting material. Appl. Phys. Lett. 2009;94:123304.

[21] Silva E a. B, Borin JF, Nicolucci P, Graeff CFO, Netto TG, Bianchi RF. Low dose ioniz
ing radiation detection using conjugated polymers. Appl. Phys. Lett. 2005;86:131902.

[22] Zotti G, Zecchin S. Decay of electrochemically injected polarons in polythiophenes.


Bipolaron stabilization by structural factors. Synth. Met. 1997;87:115-118.

[23] Wei Z, Xu J, Pu S, Du Y. Electrosyntheses of high-quality freestanding poly(fluorene-


co-3-methylthiophene) films with tunable fluorescence properties. J. Polym. Sci. Part
A Polym. Chem. 2006;44:4904-4915.

[24] Raval HN, Sutar DS, Nair PR, Rao VR. Investigation of effects of ionizing radiation
exposure on material properties of organic semiconducting oligomer - Pentacene.
Org. Electron. Elsevier B.V.; 2013;14:1467-1476.

[25] Thompson LF, Willson CG, Bowden MJ. Introduction to microlithography. American
Chemical Society; 1994. p. 527.

[26] Mitsui, H., Hosoi, F. & Kagiya T. y-radiation-Induced Cross-Linking of Polyethylene.


Polym. J. 4:79-86.
Ionizing Radiation Detectors 209
http://dx.doi.org/10.5772/60914

[27] Mitsui, H., Hosoi, F. & Kagiya T. Accelerating Effect of Acetylene on the y-Radiation-
Induced Cross-Linking of Polyethylene. Polym. J. 1974;6:20-26.

[28] Rabek JF. Photodegradation of polymers: physical characteristics and applications.


Springer; 1996. p. 212.

[29] Saum; Kenneth Ashley, Sanford; William Michael, Dimaio, Jr.; William Gerald, Ho
ward J. EG. United States Patent US6562540. 2003.

[30] Delides CG, Panagiotalidis CZ, Lega-Panagiotalidis OC. The Degradation of Cotton
by Ionizing Radiation. Text. Res. J. 1981;51:311-317.

[31] Yoshii F, Zhao L, Wach RA, Nagasawa N, Mitomo H, Kume T. Hydrogels of polysac
charide derivatives crosslinked with irradiation at paste-like condition. Nucl. Instru
ments Methods Phys. Res. Sect. B Beam Interact. with Mater. Atoms.
2003;208:320-324.

[32] Ershov BG. Radiation-chemical degradation of cellulose and other polysaccharides.


Russ. Chem. Rev. IOP Publishing; 1998;67:315-334.

[33] Laranjeira JMG, Khoury HJ, de Azevedo WM, de Vasconcelos EA, da Silva EF. Poly
aniline nanofilms as a monitoring label and dosimetric device for gamma radiation.
Mater. Charact. 2003;50:127-130.

[34] Bronze-Uhle ES, Borin JF, Batagin-Neto A, Alves MCO, Graeff CFO. MEH-PPV hyp
sochromic shifts in halogenated solvents induced by -rays. Mater. Chem. Phys.
2012;132:846-851.

[35] Lavarda FC, Graeff CFO. Ionizing radiation induced degradation of poly (2-me
thoxy-5- (2 -ethyl- hexyloxy) -1, 4-phenylene vinylene) in solution Ionizing radiation
induced degradation of poly. J. Appl. Phys. 2011;110:073510.