RDS-110
Multi-purpose Survey Meter
z wide measurement range: dose rates from
0.05 Sv/h up to 99.99 mSv/h
- clear range indication by flashing LED signals
- external probes for contamination and dose rate
measurements
- standard survey measurements
- contamination monitoring
- timed dose measurements
The RDS-110 Multi-purpose Survey Meter
is a versatile radiation detection meter which
has been designed for a wide range of
applications in different fields of rescue and
other operations involving a possibility for
abnormal radiation levels.
The functions comprise dose and dose rate
measurements and registration with extended
upper limit (100 mSv/h), it can be connected
to an end window GM tube for contamination
monitoring and it can also be used as a fixed
gamma alarm monitor with an external
gamma probe.
www.rados.com
Physical characteristics
z radiation detected:
gamma and x-rays, 50 keV...1.3 MeV
beta radiation with an external probe
z detector:
one energy-compensated GM tube. Energy response according to ambient
dose equivalent H*(10)
z measurement range:
dose rate 0.05 Sv/h - 99.99 mSv/h
dose 0.001 - 999.9 mSv
pulse rate 0.1 - 9999 CPS (external detector)
automatic range indication by flashing LED signals
z alarm levels:
freely adjustable alarm levels for dose rate, accumulated dose and CPS rate
z calibration accuracy:
5 % of the reading in 137Cs exposure, at 300 Sv/h,+20C (68F)
z dose rate linearity:
energy response: 30 % over the range 0.1 Sv/h - 99.99 mSv/h
z response to the angle of incidence:
15 % within 90 from the calibration direction with 65 keV energy
Electrical characteristics
z power supply:
3 x alkaline cell IEC LR6/AA (recommended) or standard dry cells or
rechargeable NiCd batteries of the same size
z battery life:
200 hours at normal background,
up to 400 hours without buzzer/illumination with alkaline batteries
z battery alarm:
two-step alarm for low battery voltage
Mechanical characteristics
z case: impact resistant, aluminium case, shielded against RF interferences
and NEMP
z dimensions: 92 x 199 x 44 mm (3.62 x 7.83 x 1.73 in)
z weight:
580 g (1.27 lb) without batteries
650 g (1.43 lb) with batteries
Environmental characteristics
z temperature range:
-25...+55C operational (-13F to 131F)
-40...+70C storage (-40F to 158F)
Connection
z 6-pin lockable connector with protective cap for external detectors
External detectors
z external detectors:
GMP-11 Beta Probe 0-10 000 cps
GMP-15 Pancake Beta Probe 0-10 000 cps
GMP-12 L Gamma Probe 0.05 Sv/h...10 mSv/h
GMP-12 H Gamma Probe 10 Sv/h...3 Sv/h
128145C Lamanon - France Tel +33 (0)4 90 59 59 59 Representative address:
Turku - Finland Tel +358 2 4684 600
As standards, specifications and Hamburg - Germany Tel +49 40 85193-0
design change from time to time,
please ask for confirmation of the
Smyrna (GA) - USA Tel +001 (770) 432 2744
information given in this publication. Other countries Tel +33 (0)4 90 59 60 41