0% found this document useful (0 votes)
339 views4 pages

Sla Fiamm Vrla Batteries

This document summarizes certifications, accessories, discharge and charge curves, and storage specifications for SLA batteries from FIAMM S.p.A. Key certifications include ISO 9001 for quality management, ISO 14001 for environmental management, and OHSAS 18001 for workplace safety and health. Accessories include remote venting systems, racks, cabinets, and monitoring systems. Graphs show discharge curves at different currents and final voltages and typical charge curves with voltage, current, and time. Storage specifications provide capacity loss data at different temperatures and guidelines for refreshing charges to recover capacity.

Uploaded by

Syed Faisal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
339 views4 pages

Sla Fiamm Vrla Batteries

This document summarizes certifications, accessories, discharge and charge curves, and storage specifications for SLA batteries from FIAMM S.p.A. Key certifications include ISO 9001 for quality management, ISO 14001 for environmental management, and OHSAS 18001 for workplace safety and health. Accessories include remote venting systems, racks, cabinets, and monitoring systems. Graphs show discharge curves at different currents and final voltages and typical charge curves with voltage, current, and time. Storage specifications provide capacity loss data at different temperatures and guidelines for refreshing charges to recover capacity.

Uploaded by

Syed Faisal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

SLA

CERTIFICATIONS ACCESSORIES
ISO 9001 RVS
Quality Management System (remote venting system) for IP rated applications
which require remote gassing
ISO 14001
Environmental Management System Rack for battery installation
(standard and seismic)
OHSAS 18001
Workplace Safety & Health Cabinets for battery installation
(including electrical protections and disconnection)

Battery monitoring systems

DISCHARGE CURVES at different current / final voltage (at 20C)

2.2

2.1
Battery Voltage (V/cell)

2.0

1.9

1.8

0.05 C
1.7
0.10 C
0.26 C
1.6
2C 1.22 C 0.68 C

1.5
1 10 100 1.000 10.000
Discharge time (min)
The above discharge curves are typical. For more detailed information please see the specific product sheets.

TYPICAL CHARGE CURVES STORAGE


Battery Voltage and Charge Time for Standby Use (at 20C) Capacity loss during storage at various temperatures
Charging Current (A)

140 15
100
The battery can be
Recharged Capacity (%)

120 14
Battery Voltage (V) used without
refreshing charge

Remaining Capacity (%)


Charging Voltage (V)

100 13 80
Recharged Capacity (%) Refreshing charge at
2.4 Vpc for 24 hours 5C
80 12 (at 20-25C) must be
0.10 C20 applied as soon as
60 11 possible. 60
Refreshing charge of
40 10 2.4 Vpc may be
0.05 C20 40C 30C 20C
insufficient to recover
20 the battery capacity.
Charging Current (A) 40
It is important to
avoid this area
0 0 0
0 5 10 15 20 25 0 2 4 6 8 10 12 14 16 18 20
Discharge 100%
50% Charging time (h) Storage Time (months)

FIAMM S.p.A.
V i a l e E u r o p a , 7 5 - 3 6 0 7 5 M o n t e c c h i o M a g g i o r e ( V I ) - I TA LY SLA Battery Range
TEL +39 0444 709311 - Fax +39 0444 694178

e-mail: [email protected]
w w w. f i a m m . c o m
fiamm.batteries
fiammbatteries
youtube.com/user/FIAMMvideo
FIAMM.COM
F I A M M S L A R A N G E O F VA LV E R E G U L AT E D B AT T E R I E S
H A S B E E N D E S I G N E D F O R A P P L I C AT I O N S D E M A N D I N G
TECHNOLOGY
FIAMM SLA RANGE USE
Internal Strap AGM (ABSORBED GLASS
T H E H I G H E S T L E V E L O F R E L I A B I L I T Y A N D S E C U R I T Y.
M AT ) T E C H N O L O G Y. THE
Terminal Pillar E L E C T R O LY T E I S A B S O R B E D
FIAMM HIGH INTEGRITY SLA RANGE HAS BEEN DESIGNED
I N F I B E R G L A S S S E PA R AT O R S
FOR THE MOST CRITICAL APPLICATIONS, OFFERING
WITH 99% INTERNAL
UNSURPASSED PROVEN RELIABILITY, COMPLIANT WITH Separators GAS R E C O M B I N AT I O N
THE HIGHEST RECOGNISED INTERNATIONAL STANDARDS.
E F F I C I E N C Y. BLOCS ARE
SLA USES VRLA TECHNOLOGY WITH 99% INTERNAL
GRANTS NON-SPILLABLE
RECOMBINATION EFFICIENCY, IS NON-SPILLABLE AND
AND MAINTENANCE FREE
MAINTENANCE FREE THEREFORE REQUIRES NO TOPPING
THEREFORE REQUIRES
UP OF ELECTROLYTE DURING ITS FLOAT- LIFE. SLA
RANGE IS NON-HAZARDOUS FOR AIR/SEA/RAIL/ROAD NO TOPPING UP OF

TRANSPORTATION AND IS 100% RECYCLABLE. SLA HAS E L E C T R O LY T E DURING ITS


A SELF-DISCHARGE RATE LESS THAN 2% PER MONTH, Negative Flat Plate WHOLE LIFE. LOW SELF-
GUARANTEEING LONG SHELF-LIFE. The image is for illustrative purposes only. DISCHARGE ALLOWS 6
MONTHS SHELF LIFE.

SHORT CIRCUIT INTERNAL


NOMINAL CAPACITY AT 20C
BATTERY CURRENT RESISTANCE DIMENSIONS (mm) WEIGHT
VOLTAGE (Ah)
TYPE (A) (mOhm) (kg)
(V)
10 HRS TO 1.8 VPC IEC 60896 21-22 IEC 60896 21-22 Length Width Height
12 SLA 26 12 24 884 14 166 175 125 9.5
12 SLA 50 L 12 50 1550 8.3 261 174 219 21
12 SLA 70 L 12 70 2000 6.5 261 174 219 25
12 SLA 80 L 12 80 2144 6.0 302 174 219 29
12 SLA 110 L 12 110 3000 4.2 379 174 219 37
6 SLA 125 6 125 4300 1.40 268 172 230 24
4 SLA 150 4 150 5000 0.70 271 173 202 19
6 SLA 160 6 160 3050 1.96 298 202 226 32
6 SLA 180* 6 180 3400 1.75 388 173 236 35
6 SLA 200 6 200 3700 1.58 250 125 366 36
4 SLA 200 4 200 3800 1.00 250 202 226 26
2 SLA 250 2 250 5900 0.35 271 173 202 17
2 SLA 300 2 300 6300 0.32 271 173 202 19
2 SLA 330 2 330 7500 0.27 208 195 230 22
2 SLA 405/4* 2 405 7600 0.26 250 202 226 27
2 SLA 500* 2 500 9700 0.21 388 173 236 34
2 SLA 580* 2 580 10800 0.19 388 173 236 37
SPECIFICATIONS
2 SLA 800** 2 820 9700 0.206 254 210 495 64
Industrial/Telecom specification high purity lead calcium tin grids designed to resist corrosion 2 SLA 1000** 2 1025 12000 0.165 254 210 495 74
2 SLA 1500** 2 1500 16000 0.125 275 210 660 105
VRLA AGM technology using low resistance high microporous fiberglass separators
2 SLA 2000** 2 2000 20000 0.102 368 218 660 137
Leak resistant post seal, threaded female M6/M8/M10 terminals with high conductivity and maximum torque resistance
* The front view is the short side
One-way safety relief valves allow gas to escape and prevent the ingress of oxygen. ** This cell must be installed horizontally
ELECTRICAL CHARACTERISTICS STANDARDS
Flame arrestors prevent sparks or flames entering the battery
Float Voltage: 2.27 V/cell at 20C IEC 60896 Part 21 - VRLA methods of testing
Flame retardant ABS plastic to IEC 707 FV0 and UL94 FV0 (LOI greater than 28%) Boost Voltage: 2.35 V/cell IEC 60896 Part 22 - VRLA requirements
BS 6290 Part 4 - specifications for VRLA classification
Thick walled plastics designed for superior mechanical strength Float Voltage Compensation with Temperature: -2.5 mV/cell/C
Telcordia GR-4228 - VRLA battery string certification
Self-Discharge at 20C: <2%/month BS 6334 / UL 94 V0 / IEC 707 FV0
Heat sealed box to lid weld for superior integrity
determination of materials flammability
Installation in any orientation (excluding permanently inverted) Bellcore TR-NWT-000766 - VRLA battery generic requirements
UL 1778 - UPS equipment
Eurobat >12 years VERY LONG LIFE

FIAMM reserves the right to change or revise without notice any information or detail given in this publication SLA Battery Range_2016_02_22
F I A M M S L A R A N G E O F VA LV E R E G U L AT E D B AT T E R I E S
H A S B E E N D E S I G N E D F O R A P P L I C AT I O N S D E M A N D I N G
TECHNOLOGY
FIAMM SLA RANGE USE
Internal Strap AGM (ABSORBED GLASS
T H E H I G H E S T L E V E L O F R E L I A B I L I T Y A N D S E C U R I T Y.
M AT ) T E C H N O L O G Y. THE
Terminal Pillar E L E C T R O LY T E I S A B S O R B E D
FIAMM HIGH INTEGRITY SLA RANGE HAS BEEN DESIGNED
I N F I B E R G L A S S S E PA R AT O R S
FOR THE MOST CRITICAL APPLICATIONS, OFFERING
WITH 99% INTERNAL
UNSURPASSED PROVEN RELIABILITY, COMPLIANT WITH Separators GAS R E C O M B I N AT I O N
THE HIGHEST RECOGNISED INTERNATIONAL STANDARDS.
E F F I C I E N C Y. BLOCS ARE
SLA USES VRLA TECHNOLOGY WITH 99% INTERNAL
GRANTS NON-SPILLABLE
RECOMBINATION EFFICIENCY, IS NON-SPILLABLE AND
AND MAINTENANCE FREE
MAINTENANCE FREE THEREFORE REQUIRES NO TOPPING
THEREFORE REQUIRES
UP OF ELECTROLYTE DURING ITS FLOAT- LIFE. SLA
RANGE IS NON-HAZARDOUS FOR AIR/SEA/RAIL/ROAD NO TOPPING UP OF

TRANSPORTATION AND IS 100% RECYCLABLE. SLA HAS E L E C T R O LY T E DURING ITS


A SELF-DISCHARGE RATE LESS THAN 2% PER MONTH, Negative Flat Plate WHOLE LIFE. LOW SELF-
GUARANTEEING LONG SHELF-LIFE. The image is for illustrative purposes only. DISCHARGE ALLOWS 6
MONTHS SHELF LIFE.

SHORT CIRCUIT INTERNAL


NOMINAL CAPACITY AT 20C
BATTERY CURRENT RESISTANCE DIMENSIONS (mm) WEIGHT
VOLTAGE (Ah)
TYPE (A) (mOhm) (kg)
(V)
10 HRS TO 1.8 VPC IEC 60896 21-22 IEC 60896 21-22 Length Width Height
12 SLA 26 12 24 884 14 166 175 125 9.5
12 SLA 50 L 12 50 1550 8.3 261 174 219 21
12 SLA 70 L 12 70 2000 6.5 261 174 219 25
12 SLA 80 L 12 80 2144 6.0 302 174 219 29
12 SLA 110 L 12 110 3000 4.2 379 174 219 37
6 SLA 125 6 125 4300 1.40 268 172 230 24
4 SLA 150 4 150 5000 0.70 271 173 202 19
6 SLA 160 6 160 3050 1.96 298 202 226 32
6 SLA 180* 6 180 3400 1.75 388 173 236 35
6 SLA 200 6 200 3700 1.58 250 125 366 36
4 SLA 200 4 200 3800 1.00 250 202 226 26
2 SLA 250 2 250 5900 0.35 271 173 202 17
2 SLA 300 2 300 6300 0.32 271 173 202 19
2 SLA 330 2 330 7500 0.27 208 195 230 22
2 SLA 405/4* 2 405 7600 0.26 250 202 226 27
2 SLA 500* 2 500 9700 0.21 388 173 236 34
2 SLA 580* 2 580 10800 0.19 388 173 236 37
SPECIFICATIONS
2 SLA 800** 2 820 9700 0.206 254 210 495 64
Industrial/Telecom specification high purity lead calcium tin grids designed to resist corrosion 2 SLA 1000** 2 1025 12000 0.165 254 210 495 74
2 SLA 1500** 2 1500 16000 0.125 275 210 660 105
VRLA AGM technology using low resistance high microporous fiberglass separators
2 SLA 2000** 2 2000 20000 0.102 368 218 660 137
Leak resistant post seal, threaded female M6/M8/M10 terminals with high conductivity and maximum torque resistance
* The front view is the short side
One-way safety relief valves allow gas to escape and prevent the ingress of oxygen. ** This cell must be installed horizontally
ELECTRICAL CHARACTERISTICS STANDARDS
Flame arrestors prevent sparks or flames entering the battery
Float Voltage: 2.27 V/cell at 20C IEC 60896 Part 21 - VRLA methods of testing
Flame retardant ABS plastic to IEC 707 FV0 and UL94 FV0 (LOI greater than 28%) Boost Voltage: 2.35 V/cell IEC 60896 Part 22 - VRLA requirements
BS 6290 Part 4 - specifications for VRLA classification
Thick walled plastics designed for superior mechanical strength Float Voltage Compensation with Temperature: -2.5 mV/cell/C
Telcordia GR-4228 - VRLA battery string certification
Self-Discharge at 20C: <2%/month BS 6334 / UL 94 V0 / IEC 707 FV0
Heat sealed box to lid weld for superior integrity
determination of materials flammability
Installation in any orientation (excluding permanently inverted) Bellcore TR-NWT-000766 - VRLA battery generic requirements
UL 1778 - UPS equipment
Eurobat >12 years VERY LONG LIFE

FIAMM reserves the right to change or revise without notice any information or detail given in this publication SLA Battery Range_2016_04_06
SLA
CERTIFICATIONS ACCESSORIES
ISO 9001 RVS
Quality Management System (remote venting system) for IP rated applications
which require remote gassing
ISO 14001
Environmental Management System Rack for battery installation
(standard and seismic)
OHSAS 18001
Workplace Safety & Health Cabinets for battery installation
(including electrical protections and disconnection)

Battery monitoring systems

DISCHARGE CURVES at different current / final voltage (at 20C)

2.2

2.1
Battery Voltage (V/cell)

2.0

1.9

1.8

0.05 C
1.7
0.10 C
0.26 C
1.6
2C 1.22 C 0.68 C

1.5
1 10 100 1.000 10.000
Discharge time (min)
The above discharge curves are typical. For more detailed information please see the specific product sheets.

TYPICAL CHARGE CURVES STORAGE


Battery Voltage and Charge Time for Standby Use (at 20C) Capacity loss during storage at various temperatures
Charging Current (A)

140 15
100
The battery can be
Recharged Capacity (%)

120 14
Battery Voltage (V) used without
refreshing charge

Remaining Capacity (%)


Charging Voltage (V)

100 13 80
Recharged Capacity (%) Refreshing charge at
2.4 Vpc for 24 hours 5C
80 12 (at 20-25C) must be
0.10 C10 applied as soon as
60 11 possible. 60
Refreshing charge of
40 10 2.4 Vpc may be
0.05 C10 40C 30C 20C
insufficient to recover
20 the battery capacity.
Charging Current (A) 40
It is important to
avoid this area
0 0 0
0 5 10 15 20 25 0 2 4 6 8 10 12 14 16 18 20
Discharge 100%
50% Charging time (h) Storage Time (months)

FIAMM S.p.A.
V i a l e E u r o p a , 7 5 - 3 6 0 7 5 M o n t e c c h i o M a g g i o r e ( V I ) - I TA LY SLA Battery Range
TEL +39 0444 709311 - Fax +39 0444 694178

e-mail: [email protected]
w w w. f i a m m . c o m
fiamm.batteries
fiammbatteries
youtube.com/user/FIAMMvideo
FIAMM.COM