0% found this document useful (0 votes)
827 views5 pages

Advia 2120 Reagent Insert

The document provides information on reagents and their components used in the ADVIA 120 hematology analyzer. It lists various reagent packs and their contents, storage conditions, and expiration dates. The reagents are used for performing complete blood count, white blood cell differential, reticulocyte analysis, and other hematology tests and contain components like surfactants, buffers, and preservatives. Opened reagents have varying stability periods of 45-120 days when stored at 15-30°C.

Uploaded by

Sukma Effendy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
827 views5 pages

Advia 2120 Reagent Insert

The document provides information on reagents and their components used in the ADVIA 120 hematology analyzer. It lists various reagent packs and their contents, storage conditions, and expiration dates. The reagents are used for performing complete blood count, white blood cell differential, reticulocyte analysis, and other hematology tests and contain components like surfactants, buffers, and preservatives. Opened reagents have varying stability periods of 45-120 days when stored at 15-30°C.

Uploaded by

Sukma Effendy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 5

EZ KLEEN

Product Number Symbol Contents Amount (mL)

05101601 T01-3624-54 EZ KLEEN 4 x 810 mL

T01-3624-01 EZ KLEEN 810 mL

As formulated contains:

Sodium hydroxide, 50 mmol/L

2-(2-Ethoxyethoxy)ethanol, 894 mmol/L

Surfactant

For in vitro diagnostic use

Storage and Stability Reagents

When stored between 15C and 30C:

All unopened reagents are stable until the expiration date printed on the product label.

Opened containers of the ADVIA 120 autoRETIC reagent are stable for 120 days.

Opened containers of ADVIA 120 SHEATH/RINSE are stable for 45 days.

Opened containers of ADVIA 120 EZ KLEEN and DEFOAMER are stable for 90 days.

CBC TIMEPAC
Product Number Symbol Contents Amount (mL)

08008297 T01-3626-52 CBC TIMEPAC

T01-3625-01 DEFOAMER 1 x 75 mL

T01-3627-01 RBC/PLT 2 x 2700 mL

T01-4288-01 CN-FREE HGB 2 x 1100 mL

T01-3629-01 BASO 2 x 1100 mL

ADVIA 120 DEFOAMER (Prod. No. T01-3625-01)

contains:

Silicone emulsion, 100% Shake before use.

For in vitro diagnostic use.


ADVIA 120 RBC / PLT (Prod. No. T01-3627-01)

contains:

Sodium dodecyl sulfate, 0.035 mmol/L Disodium EDTA dihydrate, 4.03 mmol/L
Tetrasodium EDTA dihydrate, 3.36 mmol/L Sodium chloride, 109.3 mmol/L Glutaraldehyde,
0.11% Buffer

For in vitro diagnostic use.

ADVIA 120 HGB (Prod. No. T01-3628-01)

contains:

Potassium cyanide, 23 mmol/L Dimethyl laurylamine oxide, 2.0%

HARMFUL!

Harmful by inhalation, in contact with skin, and if swallowed. Avoid contact with skin and
eyes. Wear suitable protective clothing and gloves. In case of accident,or if you feel unwell,
seek medical advice immediately (show the label where possible). Do not empty into
drains.

For in vitro diagnostic use.

ADVIA 120 BASO (Prod. No. T01-3629-01)

contains

Hydrochloric acid, 9.00 mmol/L Phthalic acid, 21.49 mmol/L Preservative Surfactant

For in vitro diagnostic use.

ADVIA 120 CN-FREE HGB (Prod. No. T01-4288-01)

contains:

Dimethyl laurylamine oxide, 2.0%

For in vitro diagnostic use.

Storage and Stability Reagents

When stored between 15C and 30C:

All unopened reagents are stable until the expiration date printed on the product label.

Opened containers of ADVIA 120 BASO reagent, ADVIA 120 HGB reagent, and
DEFOAMER are stable for 90 days.

Opened containers of ADVIA 120 SHEATH/RINSE and ADVIA 120 RBC/PLT reagent are
stable for 45 days.
SHEATH/RINSE
Product Number Symbol Contents Amount (mL)

02337140 T01-3664-01 SHEATH/RINSE 10 L

01554628 T01-3623-01 SHEATH/RINSE 20 L

contains:

Preservatives

Buffers

Surfactant

For in vitro diagnostic use.

Storage and Stability Reagents

When stored between 15 C and 30 C:

All unopened reagents are stable until the expiration date printed on the product label.

Opened containers of ADVIA 120 BASO reagent, ADVIA 120 HGB reagent, and DEFOAMER are
stable for 90 days.

Opened containers of ADVIA 120 SHEATH/RINSE and ADVIA 120 RBC/PLT reagent are stable
for 45 days.

Protect product from freezing.

DIFF TIMEPAC
Product Number Symbol Contents Amount (mL)

00739500 T01-3620-52 DIFF TIMEPAC

T01-3630-01 PEROX 1 2 x 650 mL

T01-3631-01 PEROX 2 2 x 305 mL

T01-3632-01 PEROX 3 2 x 585 mL

T01-3633-01 PEROX SHEATH 2 x 2725 mL

ADVIA 120 PEROX 1 contains:

Sodium dodecyl sulfate, 0.36 mmol/L


Sorbitol, 620 mmol/L

Sodium chloride, 8.35 mmol/L

Formaldehyde, 5.7%

BRIJ-35, 0.100 mmol/L

Buffer

HARMFUL!

Contains formaldehyde.

Potential cancer hazard. Harmful by inhalation, in contact with skin, and if swallowed.
Irritating to eyes, respiratory system, and skin. Possible risk of irreversable effects. May
cause sensitization by skin contact. In case of contact with eyes, rinse immediately with
plenty of water and seek medical advice. Wear suitable protective clothing and gloves. In
case of accident, or if you feel unwell, seek medical advice immediately (show label where
possible). Use only in well-ventilated areas.For in vitro diagnostic use.

ADVIA 120 PEROX 2 contains:

4-Chloro-1-naphthol, 44.8 mmol/L

Diethylene glycol, 99.2%

For in vitro diagnostic use.

ADVIA 120 PEROX 3 contains:

Stabilizer

Hydrogen peroxide, 0.3%

For in vitro diagnostic use.

ADVIA 120 PEROX SHEATH contains:

Propylene glycol, 4.06 mol/L

Surfactant

For in vitro diagnostic use.

ADVIA 120 PEROX SHEATH is also available separately.

Product Number Symbol Contents Amount (mL)

03624240T01-3633-54 PEROX SHEATH 4 x 2725 mL

Storage and Stability Reagents

When stored between 15 C and 30 C:


All unopened reagents are stable until the expiration date printed on the product label.

Opened containers of the ADVIA 120 BASO, ADVIA 120 PEROX 1, ADVIA 120 PEROX 2, ADVIA
120 PEROX 3, and ADVIA 120 PEROX SHEATH reagents are stable for 90 days.

ADVIA 120 autoRETIC

Product Number Contents Amount (mL)

T01-3622-54 autoRETIC 4 x 820 mL

T01-3622-01 autoRETIC 820 mL

ADVIA 120 autoRETIC contains:

Oxazine 750, 11.4 mg/L

Buffer

N-Tetradecyl-N,N-dimethyl-3-ammonio-1-propane sulfonate, 0.023 mmol/L

N,N-dimethylformamide, 0.38%

For in vitro diagnostic use.

Storage and Stability Reagents:

When stored between 15C and 30C:

All unopened reagents are stable until the expiration date printed on the product label.

Opened containers of the ADVIA 120 autoRETIC reagent are stable for 120 days.

Sumber: Advia 120/2120 Operator Guide