PART 1 - GENERAL
A. Drawings and general provisions of the Contract, including General and Supplementary
Special Conditions and other Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
B. Related Requirements:
1. Section 012100 "Allowances" for procedures for using unit prices to adjust quantity
allowances.
2. Section 012600 "Contract Modification Procedures" for procedures for submitting
and handling Change Orders.
3. Section 014000 "Quality Requirements" for field testing by an independent testing
agency.
1.3 DEFINITIONS
A. Unit price is[ an amount incorporated into the Agreement, applicable during the
duration of the Work as] a price per unit of measurement for materials, equipment, or
services, or a portion of the Work, added to or deducted from the Contract Sum by
appropriate modification, if the scope of Work or estimated quantities of Work required by
the Contract Documents are increased or decreased.
1.4 PROCEDURES
A. Unit prices include all necessary material, plus cost for delivery, installation, insurance,
[applicable taxes, ]overhead, and profit.
B. Measurement and Payment: See individual Specification Sections for work that requires
establishment of unit prices. Methods of measurement and payment for unit prices are
specified in those Sections. Formatted: Font: 8 pt
Formatted: Font: 8 pt
Formatted: Font: 8 pt
Formatted: Font: 8 pt
D. List of Unit Prices: A schedule of unit prices is included in Part 3. Specification Sections
referenced in the schedule contain requirements for materials described under each unit
price.
PART 3 - EXECUTION
EDIT FOR SCOPE OF WORK INCLUDED IN CONTRACT AND DELETE Formatted: Font: Times New Roman, 11 pt
ITEMS NOT REQUIRED. NUMBER PAY ITEMS ACCORDING TO DIVISION. Formatted: Indent: Left: 0.24", Right: 0.24"
Formatted: Font: Times New Roman
A. EARTHWORKS
Formatted: Indent: Left: 0.19", Hanging: 0.44"
2. Excavating and Rough Grading the Existing Surface: Formatted: Indent: Left: 0.63", Hanging: 0.38"
Formatted: Font: Times New Roman
a. Excavating and rough grading the existing surface includes but is not limited
to all excavation, stockpiling, scarification of existing surface, hauling,
spreading, watering, mixing, compacting, and grading to achieve subgrade
elevations and required soil densities by cutting and filling within the contract
limits the entire site area, including median areas and the general site devel-
opment; and all associated sampling and testing, all in accordance with the
contract drawings and specifications. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
b. Excavating and rough grading the existing surface shall be measured by the
cubic meter of on-site material excavated pursuant to this item. Quantity
computations shall be made for excavated materials based on the difference
between original cross- sections and final cross-section taken in the field at
the same locations in the same plane at uniform intervals not exceeding 25
meters, in all areas where the subgrade surface is lower than the original sur-
face. The volume shall be calculated from the cross-sections using the Aver- Formatted: Font: (Default) Times New Roman, 11 pt
age End Area Method. Formatted: Font: Times New Roman
Formatted: Indent: Left: 0.63", Hanging: 0.38"
3. Borrow Material and Rough Grading:
Formatted: Font: Times New Roman
a. Borrow material and rough grading includes, but is not necessarily limited to, Formatted: Font: 8 pt
furnishing all borrow material from a borrow pit outside Royal Commission Formatted: Font: 8 pt
property; all hauling, stockpiling, scarification of existing surfaces, spread- Formatted: Font: 8 pt
ing, watering, mixing, compacting, and grading to achieve design elevations
Formatted: Font: 8 pt
i. Removal of the existing top soil where fill for the embankment is to Formatted: Font: 8 pt
be placed, to a depth from 150 mm to 300 mm in accordance with the Formatted: Font: 8 pt
Contract Specifications, scarifying and compaction of the subgrade Formatted: Font: 8 pt
Formatted: Font: 8 pt
iv. Compaction of fill for the embankments with vibratory equipment to Formatted: Font: (Default) Times New Roman, 11 pt
the specified density, all soil testing required so as to comply with the
Contract Specifications.
Formatted: Font: Times New Roman
v. Excavation, hauling, filling and spreading of all unsuitable material Formatted: Font: (Default) Times New Roman, 11 pt
encountered during the excavation, to the Royal Commission sanitary
landfill disposal area.
b. Cofferdam shall not be measured but shall be paid as lump sum. Formatted: Font: Times New Roman
a. Quarry Run Layer includes, but is not necessarily limited to, furnishing and Formatted: Font: 8 pt
placing all quarry run layer required from off-site sources; all excavating, Formatted: Font: 8 pt
hauling, stockpiling, placing, samples; and all associated sampling and test-
ing, all in accordance with the contract drawings and specifications. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
b. Quarry Run Layer shall be measured by the cubic meter, complete in place.
Quantity computations shall be made for Quarry Run Layer based on the
length, width and thickness of placement limits shown on the approved con-
struction drawings and verified in the field. Quarry Run Layer placed outside
said limits will not be measured for payment. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
3. Filter Fabric: Formatted: Font: Times New Roman
Formatted: Indent: Left: 0.69", Hanging: 0.31"
a. Filter Fabric includes, but is not necessarily limited to, furnishing and placing
all filter fabric required; all fitting, placing both above water and under water,
developing a method for placement under water, securing fabric, slack around
irregularities, fabric edge and end laps, protection, and repairs to fabric; and
all associated sampling and testing; all in accordance with the contract draw-
ings and specifications. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
b. Filter Fabric shall be measured by the square meter, complete in place.
Quantity computations shall be for Filter Fabric based on the length and
width placement limits shown on the approved construction drawings and
verified in the field. Filter fabric placed outside said limits will not be meas-
ured for payment. Edge and end laps will not be measured for payment. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
C. PILING WORK Formatted: Indent: Left: 0.19"
Formatted: Font: Times New Roman
1. Test Piles:
Formatted: Indent: Left: 0.69", Hanging: 0.31"
a. Test Piles includes, but is not necessarily limited to, furnishing, fabricating Formatted: Font: Times New Roman
and driving precast concrete test piles; all hauling, handling, erection, place-
ment in the leads, access, staging, records, removing and redriving test piles;
and all associated sampling and testing; all in accordance with the contract
drawings and specifications. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
b. Test Piles shall be measured per each for each test pile driven complete in
place, as shown on the approved construction drawing and verified in the
field. Removing test piles when required will not be measured for payment. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
2. Load Tests: Formatted: Indent: Left: 0.69", Hanging: 0.31"
Formatted: Font: Times New Roman
a. Load Tests includes, but is not necessarily limited to, performing static load
Formatted: Font: (Default) Times New Roman, 11 pt
tests on driven test piles, providing facilities to observe measurement of de-
flection or settlement, furnishing measuring equipment, making measure- Formatted: Font: Times New Roman
ments of deflection or settlement, loading test piles and load test report; all in Formatted: Font: (Default) Times New Roman, 11 pt
accordance with the contract drawings and specification. Formatted: Font: Times New Roman
Formatted: Indent: Left: 0.69", Hanging: 0.31"
b. Load tests shall be measured per each for each load test performed, as shown
Formatted: Font: Times New Roman
on the approved construction drawings and verified in the field.
Formatted: Font: 8 pt
b. Measurement shall be by the linear meter of the final length of the pile in-
stalled (after cut-off) in the work. No separate payment shall be made for
load testing of piles and test piles. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
2. Precast Concrete Pavers: Work shall include pavers with colored sandblast finish laid
in running bond pattern on and including mortar bed, with joint grouted. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Precast concrete pavers shall be measured in square meters as installed.
3. Unglazed Ceramic Tiles: Work shall include tiles laid in narrow bands on and includ-
ing mortar bed, with joints grouted. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Tiles shall be measured in square meters as installed.
4. Sidewalks and Concrete Pathways: Work shall include 100 mm mesh-reinforced con-
crete slab with brush finish including excavation to reduce levels, compacting of sub-
grade, 100 mm thick gravel bed, all expansion joints and joint material. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Sidewalks and concrete pathways shall be measured in square meters as installed.
5. Sidewalk Drains: Work shall include mesh-reinforced concrete slab with brush finish,
including excavation to reduce levels, compacting of subgrade, 100 mm thick gravel
bed and galvanized steel checker plate cover. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Sidewalk drains shall be enumerated by size.
6. Eight-Point Star Features: Work shall include the complete paving feature including
ceramic tile and precast concrete pavers cut and laid to decorative pattern on and in-
cluding mortar bed with colored grout joints (concrete base measured separately). Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Eight-point star features shall be enumerated for payment by size and type.
7. Precast Concrete Curbs: Work shall include precast curbs set on and including in-situ
concrete foundation, including excavation, backfill and compaction. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Precast concrete curbs shall be measured in linear meters along the curb face.
9. Shade Structures: Work shall include shade structures, foundations, all street furni-
ture, trash receptacles, drinking fountains complete and all other items shown on the
drawings. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Shade structures shall be enumerated by type.
Formatted: Font: (Default) Times New Roman, 11 pt
10. Concrete Walls: Work shall include reinforced concrete retaining walls or free- Formatted: Font: 8 pt
standing walls with light sandblast finish to all exposed faces, set on and including re- Formatted: Font: 8 pt
inforced concrete base, including excavation, backfill and compaction and including Formatted: Font: 8 pt
bituminous paint coating to all soil-covered faces of retaining walls. Formatted: Font: 8 pt
Concrete walls shall be measured in linear meters by type along the face. Formatted: Font: 8 pt
Formatted: Font: 8 pt
11. Stone Mulch: Work shall include selected stone aggregate spread and leveled on the Formatted: Font: Times New Roman
site. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Stone mulch shall be measured in square meters as installed.
a. This item includes provision and placement of landscape planting sand to the
required depth of not less than 500 mm in all areas designated in the contract
drawings and specifications. Procurement of permits and materials, sampling
and testing, stockpiling, hauling and placing of material, preparation of sub-
base, settling, leveling, clean- up, and removal of excess or unsuitable mate-
rials shall be included, all in accordance with the contract drawings and spec-
ifications. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
b. Measurement for landscape planting sand shall be per cubic meter delivered,
placed, graded, and complete, as shown on the contract drawings and as veri-
fied in the field. Formatted: Font: (Default) Times New Roman, 11 pt
Measurement shall be to the extent of the required constant thickness and shall ex-
clude tapered edges and paving over-runs which shall be deemed included in the price
of the full thickness asphaltic concrete base course. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
4. Hod Laid 50 mm Asphaltic Concrete Wearing Course: The work under this item in-
cludes, surface preparation and application of tack coat; the procurement, hauling,
spreading, rolling and compaction of asphaltic concrete; and the necessary testing and
quality control, all in accordance with the Contract Drawings and Specifications. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be by the square meter of paving installed, as calculated from the
Contract Drawings and verified by field measurements. Field measurements shall in-
clude verification of the required thickness. Measurement shall be to the extent of the
required constant thickness and shall exclude tapered edges and paving over-runs
which shall be deemed included in the price of the full thickness asphaltic concrete
wearing course. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
5. Concrete Curbs and Gutters: The work under this item includes all necessary excava-
tion, formwork, supply, placement, finishing and curing of concrete, joint fillers,
backfilling and compaction, and related testing and quality control, in accordance
with Contract Drawings and Specifications. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement of concrete curbs and gutters complete in place shall be by linear meter,
as verified by field measurements along the top of the curb. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
6. Painted Pavement Markings: Work under this item includes preparation of surface,
setting out and premarking, and furnishing and application of marking to the width
and extent shown on the Contract Drawings, including hand applications, if and
where required. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Pavement marking lines shall be measured for payment purpose in net square meters, Formatted: Font: (Default) Times New Roman, 11 pt
as calculated from the Contract Drawings. No deductive measurement shall be made Formatted: Font: Times New Roman
for gaps in broken lane lines. Calculated quantities shall be verified by field meas-
Formatted: Font: (Default) Times New Roman, 11 pt
urements performed by the Contractor and confirmed by the Royal Commission.
Formatted: Font: 8 pt
7. Raised Pavement Markers (Road Studs): Work under this item includes preparation Formatted: Font: 8 pt
of surface, setting out and premarking, and furnishing and installation of markers in- Formatted: Font: 8 pt
cluding epoxy. Formatted: Font: 8 pt
Each raised pavement marker (road stud) provided and installed shall be enumerated Formatted: Font: 8 pt
for payment purposes, subject to confirmation by the Royal Commission. Formatted: Font: 8 pt
Formatted: Font: Times New Roman
8. Concrete Barrier (Double Face): Work under this item includes forms, reinforcement Formatted: Font: (Default) Times New Roman, 11 pt
and concrete for precast concrete double face barrier. It also includes compaction of
Formatted: Font: Times New Roman
subbase and all other work and materials for lifting and placing barrier into their final
position. A 25 m long sloping transition shall be installed as terminal of the full
height concrete barrier. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be by linear meter of the barrier in place as verified by field
measurements along the top. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
9. Concrete Barrier (Single Face): Work under this item includes forms, reinforcement,
and concrete for precast concrete single face barrier. It also includes compaction of
subbase and all other work and materials for lifting and placing barrier into their final
position. A 25 m long sloping transition shall be installed as terminal of the full
height concrete barrier. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be by linear meter of the barrier in place as verified by field
measurements along the top. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
H. IRRIGATION SYSTEM Formatted: Indent: Left: 0.19"
Formatted: Font: Times New Roman
1. Irrigation system includes, but is not necessarily limited to, furnishing, excavating
for, backfilling for, trenching for, laying out, installing, assembling, connecting, test-
ing, flushing and purging of all PVC pipe from the primary distribution main to the
emitters, furnishing and installing irrigation system field control modules, pressure-
reducing valve assemblies, quick- coupling valve assemblies, gate valves, remote
control valve assemblies, controller enclosures, enclosure signs, valve and water me-
ter boxes with covers, electrical boxes with lids, portland cement concrete pads, pits
and thrust blocks, color-coded lateral-line piping from the primary distribution main
to the remote control valves, lateral piping, fittings and connections; irrigation electri-
cal and wiring, irrigation electrical terminals and sealing packets, plugs and access
sleeves, gravel bedding and backfill material, paint, tubing stakes and wire, wire
markers and marker tape; furnishing and placing and applying portland cement con-
crete and curing materials; compacting backfill; supplying power wiring, conduit and
connection to operate the irrigation system after installation of the system; furnishing
and providing manuals, shop drawings, controller charts, operating devices, tempo-
rary and permanent identification of remote control valves, enclosure keys, mainte-
nance equipment, testing equipment and tools; removing all excess excavated materi-
als, and all associated sampling and testing, all in accordance with the contract draw-
ings and specifications. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
2. Measurement for the irrigation system(s) components shall be according to the fol-
lowing individual items and respective units. Measurement shall be for furnished, in-
stalled, completed, tested and approved units and shall include all surveying, excava- Formatted: Font: (Default) Times New Roman, 11 pt
tion, bedding, concrete work, backfilling, compaction and grading as required, all in Formatted: Font: Times New Roman
accordance with the contract drawings and specifications. All necessary labor, Formatted: Font: (Default) Times New Roman, 11 pt
equipment and materials required to install each measurement unit shall be included.
Formatted: Font: Times New Roman
a. Secondary irrigation PVC distribution mains and laterals includes the provi- Formatted: Font: 8 pt
sion, installation including excavation, sandbed, backfill and compaction, Formatted: Font: 8 pt
connected, tested and complete. Formatted: Font: 8 pt
Formatted: Font: 8 pt
Measurement shall be per linear meter for each size of pipe including fasten- Formatted: Font: Times New Roman
ers and sealants in culverts installed, as measured along the centerline, with
no deduction for valves and fittings. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
c. PVC irrigation pipe sleeves with reinforced concrete casing provided and in-
stalled under proposed or existing hardscaping, asphalt or concrete paving,
structures or other permanent features. Cleaning, end capping and location
marking of all sleeves is included. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be per linear meter for each size of PVC sleeve installed.
d. Zone control valve includes the provision and installation of valves with box
and cover, connections, concrete base and box markings. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be per each for each size zone control valve installed. Formatted: Indent: Left: 1"
e. Remote control valve includes the provision and installation of valve with
box and cover, 15 cm gravel base, box markings, strainer, gate valve, end
caps, flush valve, pressure gauge, pressure regulator connections, complete. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be per each for each size remote control valve installed.
f. Quick coupling valve includes the provision and installation of valve with
connection to mainline system, box and cover, complete. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be per each quick coupling valve installed. Formatted: Indent: Left: 1"
g. Water meter assembly includes the provision and installation of meter with
box and cover, concrete base, connections, complete. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be per each for each size meter assembly installed. Formatted: Indent: Left: 1"
Formatted: Font: Times New Roman
h. Control wiring for irrigation systems from field control modules to remote
control valves includes the provision and installation of control wiring in Formatted: Font: (Default) Times New Roman, 11 pt
common trench with water piping for irrigation system including connec- Formatted: Font: Times New Roman
tions, pilot wire, common wire, and wire markers at all corners. Formatted: Indent: Left: 1"
Formatted: Font: Times New Roman
Measurement shall be per linear meter of control wiring installed.
Formatted: Font: (Default) Times New Roman, 11 pt
i. Complete field control modules include the provision and installation of field Formatted: Font: Times New Roman
control modules with concrete bases, transformers, enclosures, grounding Formatted: Indent: Left: 1"
system, and connections, complete. Formatted: Font: Times New Roman
Formatted: Font: (Default) Times New Roman, 11 pt
Measurement shall be per each field control module installed.
Formatted: Font: 8 pt
j. Connections from power supply to field control modules including the provi- Formatted: Font: 8 pt
sion and installation with cable, conduit, trenching, backfilling, connections, Formatted: Font: 8 pt
and necessary circuit breakers, complete. Formatted: Font: 8 pt
Measurement shall be per linear meter of power supply installed. Formatted: Font: 8 pt
Formatted: Font: 8 pt
k. Thrust blocks include the provision and installation of concrete thrust blocks Formatted: Font: Times New Roman
cast in place complete. Formatted: Font: Times New Roman
Formatted: Indent: Left: 1"
Measurement shall be enumerated and paid for by each thrust block installed
in place complete. Formatted: Font: Times New Roman
Formatted: Font: (Default) Times New Roman, 11 pt
l. Flexible emitter hose includes the provision and installation of flexible emit- Formatted: Font: Times New Roman
ter hose (10 m per tree) and drip emitters (2.5 m per tree) with excavation,
access sleeve and cover with 10 cm gravel base, testing, backfilling, inci-
dental fittings, connected and installed complete. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be for flexible emitter hose, taking drip emitters and inci-
dental fittings installed complete per tree. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
m. Flush valves include the provision and installation of flush valves, 2 meter
coil of flushing hose, box, cover, 15 cm gravel base complete with fittings. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be per each for each size flush valve installed complete.
n. Drain valves include the provision and installation of drain valves on second-
ary pressure lines with excavation, gravel sump, concrete base, installation
box and marked cover and all incidental materials and connections installed
complete. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be for each drain valve installed, connected and complete.
Formatted: Font: (Default) Times New Roman, 11 pt
o. Pop-up Sprinklers: Work shall include sprinkler heads, PVC pipe connection Formatted: Font: Times New Roman
to main including elbows, tees and fittings, excavation and backfill. Formatted: Indent: Left: 1"
Formatted: Font: Times New Roman
Pop-up Sprinklers shall be enumerated.
Formatted: Font: (Default) Times New Roman, 11 pt
p. Bubblers: Work shall include bubbler head, PVC pipe connection to main Formatted: Font: Times New Roman
including elbows, tees and fittings, excavation and backfill. Formatted: Indent: Left: 1"
Formatted: Font: Times New Roman
Bubblers shall be enumerated.
Formatted: Indent: Left: 0.19"
Pipes shall be measured in linear meters for each diameter. Measurement shall be Formatted: Font: (Default) Times New Roman, 11 pt
made along the centerline of the pipe with no deductions made for fittings. Formatted: Font: Times New Roman
Formatted: Font: (Default) Times New Roman, 11 pt
2. Gate Valves: Work shall include valve, valve box and cover, concrete ring and con-
Formatted: Font: Times New Roman
crete support block, connections to main, additional excavation, disinfecting and test-
ing as specified. Formatted: Font: 8 pt
Formatted: Font: 8 pt
Measurement shall be per each for each size gate valve installed. Formatted: Font: 8 pt
Formatted: Font: 8 pt
Measurement shall be per each fire hydrant installed. Formatted: Font: Times New Roman
Formatted: Font: (Default) Times New Roman, 11 pt
J. SANITARY SEWER SYSTEM Formatted: Font: Times New Roman
Formatted: Indent: Left: 0.19"
1. Sewer Pipes: Work shall include PVC pipes laid and jointed in trenches (measured
Formatted: Font: Times New Roman
separately) including connections to fittings and connections to existing sewer mains
or stub-outs. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Pipes shall be measured in linear meters for each diameter. Measurement shall be
made along the centerline of the pipe with no deductions made for fittings or man-
holes. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
2. Sewer Pipe Fittings: Work shall include jointing to mains and testing as specified. Formatted: Font: Times New Roman
Measurement shall be per each for each type and size of pipe fitting installed.
3. Cast iron Sewer Clean-outs: Work shall include clean-out, wye, removable ferrule,
concrete cap protection, compression plug, connection to sewer main, and testing as
specified. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be per each for each size clean-out installed.
4. Manholes: Work shall include fiberglass manhole, with cast iron cover and frame,
brick adjustment, concrete ring, compacted gravel base, reinforced concrete base,
benching and grouted pipe connections, additional excavation and backfill, and test-
ing as specified. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be per each for each size and type of manhole installed.
Formatted: Indent: Left: 0.19"
K. ELECTRICAL POWER DISTRIBUTION
Formatted: Font: Times New Roman
1. Padmounted Transformer and Padmounted Switchgear: Formatted: Font: Times New Roman
Formatted: Indent: Left: 0.69", Hanging: 0.31"
a. Supply: This shall include, but not necessarily limited to delivery to site, Formatted: Font: Times New Roman
storage, field verification of material at site in good condition, and free of any Formatted: Font: (Default) Times New Roman, 11 pt
damage in transit.
Formatted: Font: Times New Roman
b. Installation: This shall include, but is not necessarily limited to delivery to Formatted: Font: 8 pt
construction site, setting of the unit on foundation pads, anchoring, ground- Formatted: Font: 8 pt
ing, connection of high voltage cables and field tests of equipment for electri- Formatted: Font: 8 pt
cal and mechanical performance in accordance with the manufacturer's rec- Formatted: Font: 8 pt
ii. Installation of splices shall include delivery from storage area to con-
struction site, preparation of cables jointing two sections of the ca-
bles, identification tag, splice, supports, grounding of supports and
testing. Formatted: Font: (Default) Times New Roman, 11 pt
Measurement shall be by the linear meter of wire installed and measured be- Formatted: Font: 8 pt
c. Reinforced Concrete Handholes for LV: This work item includes the low
voltage type reinforced concrete handholes, including heavy duty cover. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
Measurement shall be by the unit of each handhole, complete in place.
d. x mm PVC Duct Concrete Encased Complete: This work item includes Formatted: Font: Times New Roman
the reinforced concrete encased duct under road crossings, complete with
mm dia. PVC pipes.
e. x mm PVC Duct Concrete Encased Complete: This work item includes Formatted: Font: Times New Roman
the supply and installation of the concrete encased duct.
c. 400 Watt High Pressure Sodium Lighting Fixture Complete: This work item Formatted: Font: (Default) Times New Roman, 11 pt
includes the 400 watt fixture complete with the lamp and the ballast. The fix- Formatted: Font: Times New Roman
ture shall have diecast aluminum corrosion resistant housing, water and dust Formatted: Font: (Default) Times New Roman, 11 pt
tight and aluminum reflector and hinged refractor. Formatted: Font: Times New Roman
Formatted: Font: Times New Roman
Each fixture provided and installed shall be enumerated for payment purpos-
es, subject to confirmation by the Royal Commission. Formatted: Font: 8 pt
Formatted: Font: 8 pt
d. Low Voltage Cable, 4 x 16 mm2, Direct Burial. Formatted: Font: 8 pt
Formatted: Font: 8 pt
i. Reinstallation of Existing Roadway Lighting Columns: Includes the raising in Formatted: Font: Times New Roman
elevation of the existing columns and luminaries as required due to the new
grade level. Also included is all necessary disconnecting and reconnecting
the 480 volt lighting system.
6. General Electrical Work: Formatted: Tab stops: 6.25", Right + Not at 6.5"
Formatted: Font: 8 pt
a. Cable: Formatted: Indent: Left: 0.69", Hanging: 0.31"
Formatted: Font: Times New Roman
i. Cable includes, but is not necessarily limited to, furnishing and in-
Formatted: Font: Times New Roman
stalling cable, making electrical connections at handholes and lights,
sealing cable ends, and all assorted sampling and testing, all in ac- Formatted: Indent: Left: 1"
cordance with the contract drawings and specifications. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
ii. Cable shall be measured by the linear meter, for each size complete
in place, along the centerline of the line from handhole to handhole
or from light fixture to light fixture, according to the limits shown on
the approved construction drawings and verified in the field. Formatted: Font: (Default) Times New Roman, 11 pt
Formatted: Font: Times New Roman
b. Conduit: Formatted: Indent: Left: 1"
Formatted: Font: Times New Roman
i. Conduit includes, but is not necessarily limited to, excavation for in-
stallation of conduits in earth including compaction of the trench bot-
tom; furnishing, placing, installing and connecting conduit in earth or
in concrete, fittings and accessories; placing and compacting trench
backfill materials; disposing of excess excavated materials, and all
associated sampling and testing; all in accordance with the contract
drawings and specifications. Formatted: Font: (Default) Times New Roman, 11 pt
ii. Conduit shall be measured by the linear meter, for each size complete
in place, along the centerline of the conduit according to the limits
shown on the approved construction drawings and verified in the
field. Formatted: Font: (Default) Times New Roman, 11 pt
i. Handhole, Precast includes, but is not necessarily limited to, excava- Formatted: Font: 8 pt
tion for the installation of handholes compacting the foundation soils Formatted: Font: 8 pt
beneath each handhole; furnishing form materials and constructing Formatted: Font: 8 pt
forms for handholes, and their frames and covers; furnishing, placing, Formatted: Font: 8 pt
L. <Insert unit price number according to Division> <Insert unit price item>: Formatted: Indent: Left: 0.19", Hanging: 0.5"
Formatted: Font: Bold
1. <Insert unit price item description> according to Section <Insert Section
Formatted: Font: Bold
number> <Insert Section title>.
Formatted: Indent: Left: 0.69", Hanging: 0.31"
1. Description: Miscellaneous lintels and other supports not otherwise indicated in the
Contract Documents, according to Section 051200 "Structural Steel Framing" and
Section 055000 "Metal Fabrications."
2. Unit of Measurement: Cost in place of pounds (kilograms) of fabricated steel as
indicated on itemized invoice of steel supplier.