AIR CONDITIONERS

XC20
ELITE® Series
Variable Capacity
Bulletin No. 210732
P R O D U C T S P E C I F I C AT I O N S November 2017
Supersedes August 2017

* iComfort® S30
Thermostat

SEER up to 20.00
2 to 5 Tons
Cooling Capacity - 23,400 to 58,500 Btuh
MODEL NUMBER INDENTIFICATION

X C 20 - 036 - 230 A 05
Refrigerant Type Minor Revision Number
X = R-410A

Ratings Revision Level

Unit Type
C = Air Conditioner Voltage
230 = 208/230V-1phase-60hz

Series Nominal Cooling Capacity


024 = 2 tons
036 = 3 tons
048 = 4 tons
060 = 5 tons

* iComfort® Communicating Thermostat required. Not furnished - Order separately.


FEATURES

I
B
CONTENTS
AHRI System Matches............................................... 11 H
Dimensions................................................................... 9
Electrical Data.............................................................. 7 J
Features....................................................................... 2
Field Wiring................................................................... 8
Installation Clearances................................................. 8 G F C
Model Number Indentification....................................... 1
Sound Data................................................................... 8
Specifications............................................................... 7

E D

WARRANTY APPLICATIONS
SEER up to 20.00.
Compressor - Limited warranty for ten years in
residential installations and five years in non-residential 2 through 5 ton.
installations. Single phase power supply.
All other covered components - Limited warranty for Sound levels as low as 65 dB.
five years in residential installations and one year in Vertical air discharge allows concealment behind shrubs
non-residential installations. at grade level or out of sight on a roof.
Refer to Lennox Equipment Limited Warranty certificate Matching add-on furnaces with indoor coils, or air
included with unit for specific details. handlers provide a wide range of cooling capacities and
applications. See AHRI System Matches.
APPROVALS
See Indoor Coils and Air Handlers tab sections for data.
AHRI Certified to AHRI Standard 210/240-2008.
Units shipped completely factory assembled, piped, and
Sound rated in Lennox reverberant sound test room
wired. Each unit is test operated at the factory insuring
in accordance with test conditions included in AHRI
proper operation.
Standard 270-2008.
Installer must set air conditioner, connect refrigerant
Tested in the Lennox Research Laboratory
lines, and make electrical connections to complete job.
environmental test room.
NOTE - The XC20 can only be matched with
Rated according to U.S. Department of Energy (DOE)
test procedures. iComfort® Communicating variable-speed indoor
furnaces and air handlers.
Air conditioners and components within bonded for
grounding to meet safety standards for servicing
required by UL and CEC.
Units are ETL certified for the U.S. and Canada.
ISO 9001 Registered Manufacturing Quality System.
For expanded ratings, see www.LennoxPROs.com.
Energy Star® certified units are designed to use less
energy, help save money on utility bills, and help protect
the environment.

XC20 - 2 to 5 Ton Air Conditioner / Page 2


FEATURES
REFRIGERATION SYSTEM E Hi-Capacity Liquid Line Drier
R-410A Refrigerant Factory installed in the liquid line, the drier traps
Non-chlorine, ozone friendly, R-410A. moisture or dirt that could contaminate the refrigerant
A system.
Unit pre-charged with refrigerant.
See Specification table. 100% molecular-sieve bead type drier.
Optional Accessories
B Outdoor Coil Fan
Direct drive fan moves large air volumes uniformly Expansion Valve Kits
through entire condenser coil for high refrigerant cooling Must be ordered extra and field installed on certain
capacity. indoor units. See TXV Usage table.
Vertical air discharge minimizes operating sounds and Chatleff style fitting.
eliminates damage to lawn and shrubs.
Freezestat
Fan guard constructed of corrosion-resistant PVC
Installs on or near the discharge line of the indoor coil or
(polyvinyl chloride) coated steel.
on the suction line.
Fan service access accomplished by removal of fan
Senses suction line temperature and cycles the
guard.
compressor off when suction line temperature falls
Variable-Speed Outdoor Coil Fan Motor With below it’s setpoint.
Integrated Control Opens at 29°F and closes at 58°F.
Outdoor coil fan motor with integrated control is
programmed for variable capacity operation. Fan speed Refrigerant Line Kits
is directly controlled by the iComfort® communications Refrigerant lines (suction & liquid) are shipped
between the outdoor unit iComfort® Communicating refrigeration clean. Lines are cleaned, dried,
Control and the iComfort® Communicating Thermostat. pressurized, and sealed at factory.
Fan motor is inherently protected. Suction line fully insulated.
Motor totally enclosed for maximum protection from L15 lines are stubbed at both ends.
weather, dust and corrosion. See Specifications table for selection.
C Copper Tube/Enhanced Fin Coil Not available for -060 model and must be field
Lennox designed and fabricated coil. fabricated.
Ripple-edged aluminum fins. NOTE - The XC20 is a variable capacity air conditioner
utilizing variable speed compressor technology. With
Copper tube construction. the variable speed compressor and variable pumping
Lanced fins provide maximum exposure of fin surface to capacity, additional consideration must be given to
air stream resulting in excellent heat transfer. refrigerant piping sizing and application.
Fin collars grip tubing for maximum contact area. Please refer to the Installation Instructions or Service
Flared shoulder tubing connections. Literature for Line Set Requirements and Refrigerant
Coil is factory tested under high pressure to insure Piping Guidelines.
leakproof construction.
Entire coil is accessible for cleaning.
High Pressure Switch
Shuts off unit if abnormal operating conditions cause the
discharge pressure to rise above setting.
Protects compressor from excessive condensing
pressure.
Auto-reset.
D Low Pressure Switch
Shuts off unit if suction pressure falls below setting.
Provides loss of charge and freeze-up protection.
Auto-reset.

XC20 - 2 to 5 Ton Air Conditioner / Page 3


FEATURES
PRECISE COMFORT® TECHNOLOGY G DC Inverter Control
The Variable Capacity Compressor and DC Inverter Converts AC line voltage into
Control is an integrated system that operates together filtered variable DC voltage.
to reduce overall energy usage when compared to Provides continuous compressor
conventional air conditioners. operation, while adjusting the
capacity according to indoor
F Variable Capacity Scroll Compressor temperature.
Operates on a variable frequency determined by the DC
Inverter Control to vary Adjusts compressor output in
capacity based on the increments as small as 1%.
cooling load required. The accurate sensing of cooling
Features high efficiency load prevents frequent changes
with uniform suction flow, in capacity and ensures efficient,
constant discharge flow, economical operation.
high volumetric efficiency Power Factor Correction (PFC) circuit monitors the DC
and quiet operation. bus for high, low and abnormal voltage conditions to
Consists of two involute protect the compressor.
spiral scrolls matched Two LEDS (red and green) indicate inverter operating
together to generate status and aid in troubleshooting.
a series of crescent Noise filter reduces unwanted electromagnetic
shaped gas pockets interference (EMI). Integrated on the control for 024
between them. and 036 models, external to the control for 048 and 060
During compression, models.
one scroll remains The inverter reactor (mounted separately) adds
stationary while the other scroll orbits around it. inductance to the line between the inverter and
Gas is drawn into the outer pocket, the pocket is sealed the compressor to limit current rise and protect the
as the scroll rotates. compressor.
As the spiral movement continues, gas pockets are pushed
to the center of the scrolls. Volume between the pockets
is simultaneously reduced. When the pocket reaches the
center, gas is now at high pressure and is forced out of a
port located in the center of the fixed scrolls.
During compression, several pockets are compressed
simultaneously resulting in a smooth continuous
compression cycle. Continuous flank contact,
maintained by centrifugal force, minimizes gas leakage
and maximizes efficiency.
Compressor is tolerant to the effects of slugging and
contaminants. If this occurs, scrolls separate, allowing
liquid or contaminants to to be worked toward the center
and discharged.

Top Cap Thermal Sensor Switch


Located on top of the compressor casing.
Discontinues compressor operation in case of abnormal
operating conditions.

Compressor Sound Dampening System


A polyethylene compressor cover containing a 2 inch
thick batt of fiberglass insulation for better sound
dampening.
All open edges are sealed with a one-inch wide hook
and loop fastening tape.

Crankcase Heater
Crankcase heater prevents migration of liquid
refrigerant into compressor and ensures proper
compressor lubrication.
XC20 - 2 to 5 Ton Air Conditioner / Page 4
FEATURES
CONTROLS • H
 umid - The system supplies lower indoor airflow
H iComfort Communicating Control
® at all compressor capacities, improving humidity
Advanced control communicates information about removal by operating at a lower sensible to total ratio.
various operating parameters in the air conditioner to Outdoor Air Temperature Sensor
the iComfort® Communicating Used with iComfort® Communicating Thermostats.
Thermostat to constantly
Sensor is auto-detected when connected to thermostat.
maintain the highest level of
comfort, performance and REQUIRED COMPONENTS
efficiency available. NOTE - The XC20 Air Conditioner can only be
Auto Configuration - On start-up used with an iComfort® Communicating
the control automatically sends a Thermostat.
description of the unit to the iComfort® Communicating
Thermostat to automatically configure the features iComfort® S30 Ultra-Smart Thermostat (part of the
available. iComfort® Residential Communicating Control
System)
Control also features:
The iComfort® S30 Thermostat recognizes and connects
• Seven-Segment Display shows information about to all iComfort® Communicating products to automatically
outdoor unit type and capacity and also displays configure and control
alerts for common fault conditions (electrical and the heating/cooling
mechanical). system (based on
• Low voltage protection prevents compressor user-specified settings)
operation when voltage is not within the specified for the highest level of
range. comfort, performance
• High and low pressure switch monitoring with and efficiency. Also
provisions for lockout. recognizes model and
serial number information
• Five-Strike lockout protection protects compressor.
for iComfort® Communicating products to simplify system
• Liquid line temperature and sensor monitoring. setup.
• EEPROM storage of all local configurations. Wi-Fi remote temperature monitoring and adjustment
• Non-volatile memory storage of 100 alarm codes with through a home wireless network for desktop PCs,
display of last 10 codes for troubleshooting. laptops and apps for smartphones or tablets. Also
• Built-in low ambient control. displays service alerts and reminders.
Dealer Dashboard features online real-time monitoring
Low Ambient Operation of installed iComfort® Communicating systems.
The air conditioner can operate down to 0°F outdoor air
A simple easy-to-use touchscreen allows complete
temperature.
system configuration. Scheduled maintenance alerts,
NOTE - A freezestat is recommended for extra system warnings and troubleshooting are also displayed
protection during low ambient operation. on thermostat screen.
Climate IQ™ Technology Works with Amazon® Alexa-enabled products.
Optimizes dehumidification settings for specific climates Easy to read 7 in. high definition color display
to improve home comfort during cooling operation. (measured diagonally).
iComfort® S30 Thermostat Setting: Installer setup screens allow quick and simple system
• Climate IQ (Auto) - Dry, Normal, Basic and Humid configuration without a manual, Installer can also run
modes are automatically set based on the difference tests on complete system or individual components for
between the measured relative humidity and the easy maintenance and troubleshooting.
relative humidity setting. Serial communications bus (RSBus), with less wiring
All modes are selected on the iComfort® Communicating than a conventional heating/cooling system, allows
Thermostat. system communication. Uses 4-wire, 18-gauge
iComfort Wi-Fi® Thermostat Settings: standard thermostat wiring.
• Dry - The system supplies higher indoor airflow at Remote outdoor temperature sensor (furnished with
all compressor capacities, increasing efficiency by outdoor unit) allows the thermostat to display outdoor
operating at a higher sensible to total ratio. temperature. Required in Humiditrol® applications.
• Moderate - The system supplies indoor airflow that High Definition Color Display, Mag-Mount, Smart Hub
balances efficiency and comfort. Controller, wallplate (for retrofit installations) furnished
for easy installation.
See the iComfort® S30 Thermostat Product Specifications
bulletin in the Controls section for more information.
XC20 - 2 to 5 Ton Air Conditioner / Page 5
FEATURES
REQUIRED COMPONENTS (continued) CABINET

iComfort Wi-Fi® Thermostat (part of the iComfort®


I Heavy-gauge steel construction
Pre-painted cabinet finish.
Residential Communicating Control System)
Control box is conveniently located with all controls
The iComfort Wi-Fi® Thermostat recognizes and
factory wired.
connects to all iComfort® Communicating products
Large removable panel provides service access.
to automatically
Drainage holes are provided in base section for
configure and control
moisture removal.
the heating/cooling
High density polyethylene unit support feet raise the
system (based
unit off of the mounting surface, away from damaging
on user-specified
moisture.
settings) for the
highest level of PermaGuard™ Unit Base
comfort, performance Durable zinc-coated base section resists rust and
and efficiency. Also corrosion.
recognizes model and serial number information for
iComfort® Communicating products to simplify system J SmartHinge™ Louvered Coil Protection
setup. Steel louvered panels
Wi-Fi remote temperature monitoring and adjustment provides complete coil
through a home wireless network for desktop PCs, protection.
laptops and apps for smartphones or tablets. Also Panels are hinged to allow
displays service alerts and reminders. easy cleaning and servicing
of coils.
Dealer Dashboard features online real-time monitoring Panels may be completely
of installed iComfort® Communicating systems. removed.
A simple easy-to-use touchscreen allows complete Interlocking tabs and slots
system configuration. Scheduled maintenance alerts, assure tight fit on cabinet.
system warnings and troubleshooting are also displayed
on thermostat screen. K Refrigerant Line Connections, Electrical Inlets and
Service Valves
Easy to read 7-inch color screen (measured diagonally).
Suction and liquid lines are located on corner of unit
Installer setup screens allow quick and simple system cabinet and are made with sweat connections. See
configuration without a manual, Installer can also run dimension drawing.
tests on complete system or individual components for Fully serviceable brass service valves prevent corrosion
easy maintenance and troubleshooting. and provide access to refrigerant system. Suction valve
Serial communications bus (RSBus), with less wiring can be fully shut off, while liquid valve may be front
than a conventional heating/cooling system, allows seated to manage refrigerant charge while servicing
system communication. Uses 4-wire, 18-gauge system.
standard thermostat wiring. Refrigerant line connections and field wiring inlets
Remote outdoor temperature sensor (furnished with are located in one central area of the cabinet. See
outdoor unit) allows the thermostat to display outdoor dimension drawing.
temperature. Required in Humiditrol® applications.
See the iComfort Wi-Fi® Thermostat Product
Specifications bulletin in the Controls section for more
information.

XC20 - 2 to 5 Ton Air Conditioner / Page 6


SPECIFICATIONS
General Model No. XC20-024 XC20-036 XC20-048 XC20-060
Data Nominal Tonnage 2 3 4 5
Connections Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8
(sweat) Suction line (o.d.) - in. 3/4 7/8 7/8 1-1/8
Refrigerant 1
R-410A charge furnished 7 lbs. 5 oz. 8 lbs. 6 oz. 10 lbs. 7 oz. 12 lbs. 1 oz.
Outdoor Net face area - sq. ft. Outer coil 24.50 16.33 21.00 29.09
Coil Inner coil --- 15.76 20.27 28.24
Tube diameter - in. 5/16 5/16 5/16 5/16
No. of rows 1 2 2 2
Fins per inch 26 22 22 22
Outdoor Diameter - in. 22 22 22 26
Fan No. of blades 4 4 4 3
Motor hp 1/6 1/4 1/3 1/3
Cfm - minimum speed 1500 3100 3000 2900
maximum speed 2600 3600 4000 4325
Rpm - minimum speed 400 600 600 600
maximum speed 700 700 800 865
Watts - minimum speed 25 80 70 80
maximum speed 60 115 160 195
Shipping Data - lbs. 1 pkg. 243 241 287 321
ELECTRICAL DATA
Line voltage data - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph
2
Maximum overcurrent protection (amps) 30 30 50 50
3
Minimum circuit ampacity 19.1 20.6 29.1 29.3
Compressor Rated load amps 13.0 14.2 21.0 21.2
Locked rotor amps 13.0 13.0 20.0 20
Power factor .98 .99 .99 .99
Outdoor Fan Motor Full load amps 2.8 2.8 2.8 2.8
REQUIRED COMPONENTS - ORDER SEPARATELY
iComfort® S30 Thermostat 12U67 • • • •
iComfort Wi-Fi Thermostat
®
10F81 • • • •
4
Discharge Air Temperature Sensor 88K38 • • • •
OPTIONAL ACCESSORIES - ORDER SEPARATELY
5
Freezestat 3/8 in. tubing 93G35 • • • •
5/8 in. tubing 50A93 • • • •
6
 efrigerant
R L15-41-20 L15-41-40 •
Line Sets L15-41-30 L15-41-50
L15-65-30 L15-65-40 • •
L15-65-50
Field Fabricate •
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and
additional refrigerant charge required.
2
HACR type breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.
4
Used with the iComfort® Communicating Thermostats for optional service diagnostics.
5
Freezestat is recommended for low ambient operation.
6
Refer to the Installation Instructions or Service Literature for Line Set Requirements and Refrigerant Piping Guidelines.

XC20 - 2 to 5 Ton Air Conditioner / Page 7


SOUND DATA
Octave Band Linear Sound Power Levels dB, re 10-12 Watts - Center Frequency - Hz 1
Sound Rating
Unit Number (SRN)
Model Operation 125 250 500 1000 2000 4000 8000 (dBA)

Min. 67 62 54 55 52 53 62 65
024
Max. 67 64 63 61 56 64 64 72

Min. 67 63 62 58 52 55 65 67
036
Max. 67 65 66 64 60 68 63 75

Min. 67 63 63 58 53 50 64 68
048
Max. 70 68 71 67 62 60 66 77

Min. 66 62 64 58 53 51 61 69
060
Max. 70 69 72 69 61 58 62 77
1
Sound Rating Number according to ANSI/AHRI Standard 270-2008. “SRN” is the overall A-Weighted Sound Power Level, (LWA), dB (100 Hz to 10,000 Hz).

FIELD WIRING

DISCONNECT ICOMFORT® DISCONNECT


SWITCH COMMUNICATING SWITCH
(By Others) THERMOSTAT (By Others)
(REQUIRED)
A
A - Two Wire Power (not furnished)
B D
B - Two Power (not furnished) See Electrical Data
C - Four Wire Low Voltage RSBus (not furnished) 18 ga. minimum
D - Four Wire Low Voltage RSBus (not furnished) 18 ga. minimum
C
LENNOX All wiring must conform to NEC or CEC and local electrical codes.
LENNOX
AIR HEATING UNIT
CONDITIONER OR
AIR HANDLER
UNIT

INSTALLATION CLEARANCES - INCHES (MM)

NOTES:
See NOTES
Service clearance of 30 in. (762 mm) must be maintained on one
of the sides adjacent to the control box.

Clearance to one of the other three sides must be 36 in. (914 mm)

See See Clearance to one of the remaining two sides may be 12 in. (305
NOTES NOTES mm) and the final side may be 6 in. (152 mm).

A clearance of 24 in. (610 mm) must be maintained between two


units.
Control
See NOTES Box 48 in. (1219 mm) clearance required on top of unit.

XC20 - 2 to 5 Ton Air Conditioner / Page 8


DIMENSIONS - INCHES (MM)

UNIT SUPPORT
FEET

16-7/8 26-7/8
(429) (683)

SUCTION LINE
CONNECTION 8-3/4
(222) 3-3/4 (95)
LIQUID LINE
TOP VIEW CONNECTION 30-3/4 (781)
3-1/8 4-5/8
(79) (117)

TOP VIEW BASE SECTION


(Large Base)

39-3/8 (1000) 35-1/2 (902)


DISCHARGE AIR

LIQUID LINE
CONNECTION

ELECTRICAL A
INLETS
SUCTION LINE
CONNECTION

2 (51)
4-3/4
4-1/4(108) (121)

1 (25)
SIDE VIEW END VIEW

A
Model No.
in. mm
XC20-024 39 991
XC20-036 39 991
XC20-048 45 1143
XC20-060 45 1143

XC20 - 2 to 5 Ton Air Conditioner / Page 9


TXV USAGE MOST POPULAR MATCHES
Use this table for C33, CH23, CH33, CH35 and CR33 Field Outdoor Unit Indoor Unit
Installed TXV Match-Ups Model No. Model No
Outdoor Unit Order No. XC20-024 CBX32MV-024/030
Model No. XC20-036 CBX32MV-036
XC20-024 12J18 XC20-048 CBX32MV-048
XC20-036 12J19 XC20-060 CBX32MV-060
XC20-048 12J20
XC20-060 12J20
CX34 upflow coils and all Lennox air handlers are shipped with a factory
installed TXV. In most cases, no change out of the valve is needed.
C33, CH33 and CH35 coils - Factory installed orifice must be replaced with the
expansion valve listed.
CR33 and CH23 coils - Use the expansion valve listed.

AHRI STANDARD 210/240

Cooling or heating capacities are net values, including Units which do not have an indoor air-circulating blower
the effects of blower motor heat, and do not include furnished as part of the model, i.e., split system with
supplementary heat. Power input is the total power input indoor coil only, is established by subtracting from the
to the compressor(s) and fan(s), plus any controls and total cooling capacity 1250 Btu/h per 1,000 cfm, and by
other items required as part of the system for normal adding the same amount to the heating capacity. Total
operation. power input for both heating and cooling is increased by
365 W per 1,000 cfm of indoor air circulated.

XC20 - 2 to 5 Ton Air Conditioner / Page 10


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Expansion Coil or AHRI
Capacity SEER EER Furnace
No. Device Air Handler Reference
XC20-024-230 TXV 23800 20 14 C35-30/36C SLP98UH090XV36C 8462425
XC20-024-230 TXV 24000 20 14 C35-30A SL280UH070V36A 8510314
XC20-024-230 TXV 24000 20 14 C35-30A SL280UH070XV36A 8462418
XC20-024-230 TXV 24000 20 14 C35-30B EL296UH045XV36B 8462421
XC20-024-230 TXV 24000 20 14.5 C35-30B EL296UH070XV36B 8462422
XC20-024-230 TXV 24000 20 14.5 C35-30B SL280UH090V36B 8510316
XC20-024-230 TXV 24000 20 14.5 C35-30B SLP98UH070XV36B 8462424
XC20-024-230 TXV 24000 20 14.5 C35-36B EL296UH045XV36B 8462431
XC20-024-230 TXV 24000 20 14.5 C35-36B EL296UH070XV36B 8462432
XC20-024-230 TXV 24000 20 14.5 C35-36B SL280UH090V36B 8462433
XC20-024-230 TXV 24000 20 14.5 C35-36B SLP98UH070XV36B 8462434
XC20-024-230 TXV 24000 20 14 CBX32MV-024/030 8085686
XC20-024-230 TXV 24000 20 14.5 CBX32MV-036 8085688
XC20-024-230 TXV 24000 20 14 CBX40UHV-024 8085690
XC20-024-230 TXV 24000 20 14 CBX40UHV-030 8085691
XC20-024-230 TXV 23800 20 14 CH23-51 EL296UH045XV36B 8085693
XC20-024-230 TXV 23800 20 14 CH23-51 EL296UH070XV36B 8085694
XC20-024-230 TXV 23800 20 14 CH23-51 SL280UH070V36A 8085696
XC20-024-230 TXV 23800 20 14 CH23-51 SL280UH070XV36A 8510320
XC20-024-230 TXV 24000 20 14 CH23-51 SL280UH090V36B 8085698
XC20-024-230 TXV 23800 20 14 CH23-51 SLP98UH070XV36B 8085699
XC20-024-230 TXV 23400 20 13.5 CH33-19 SL280UH070V36A 8510322
XC20-024-230 TXV 23400 20 13.5 CH33-19 SL280UH070XV36A 8085701
XC20-024-230 TXV 24000 20 14.5 CH33-31B EL296UH045XV36B 8085702
XC20-024-230 TXV 24000 20 14.5 CH33-31B EL296UH070XV36B 8085704
XC20-024-230 TXV 24000 20 14.5 CH33-31B SL280UH090V36B 8085706
XC20-024-230 TXV 24000 20 14.5 CH33-31B SLP98UH070XV36B 8085707
XC20-024-230 TXV 24000 20 14 CH33-42B EL296UH045XV36B 8085710
XC20-024-230 TXV 24000 20 14 CH33-42B EL296UH070XV36B 8085711
XC20-024-230 TXV 24000 20 14.5 CH33-42B SL280UH090V36B 8085713
XC20-024-230 TXV 24000 20 14 CH33-42B SLP98UH070XV36B 8085715
XC20-024-230 TXV 24000 20 14.5 CH33-43C EL296UH090XV36C 8085717
XC20-024-230 TXV 24000 20 14.5 CH33-43C SLP98UH090XV36C 8085719
XC20-024-230 TXV 24000 20 14 CH35-30A SL280UH070V36A 10041107
XC20-024-230 TXV 24000 20 14.5 CH35-30B EL296UH045XV36B 8085720
XC20-024-230 TXV 24000 20 14.5 CH35-30B EL296UH070XV36B 8085722
XC20-024-230 TXV 24000 20 14.5 CH35-30B SL280UH090V36B 8085723
XC20-024-230 TXV 24000 20 14.5 CH35-30B SLP98UH070XV36B 8085725
XC20-024-230 TXV 24000 20 14.5 CH35-42C EL296UH045XV36B 8085727
XC20-024-230 TXV 24000 20 14.5 CH35-42C SLP98UH090XV36C 8085728
XC20-024-230 TXV 24000 20 14 CR33-48B EL296DF045XV36B 8085730
XC20-024-230 TXV 24000 20 14 CR33-48B EL296DF070XV48B 8085731
XC20-024-230 TXV 24000 20 14 CR33-48B SL280DF090V48B 8085733
XC20-024-230 TXV 24000 20 14 CR33-48B SLP98DF070XV36B 8085735
XC20-024-230 TXV 24000 20 14 CR33-48C SLP98DF090XV36C 8085736
XC20-024-230 TXV 23800 20 14 CX35-30/36C SLP98UH090XV36C 8463548
XC20-024-230 TXV 24000 20 14 CX35-30A SL280UH070V36A 8510334
Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

XC20 - 2 to 5 Ton Air Conditioner / Page 11


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Expansion Coil or AHRI
Capacity SEER EER Furnace
No. Device Air Handler Reference
XC20-024-230 TXV 24000 20 14 CX35-30A SL280UH070XV36A 8463541
XC20-024-230 TXV 24000 20 14 CX35-30B EL296UH045XV36B 8463544
XC20-024-230 TXV 24000 20 14.5 CX35-30B EL296UH070XV36B 8463545
XC20-024-230 TXV 24000 20 14.5 CX35-30B SL280UH090V36B 8463546
XC20-024-230 TXV 24000 20 14.5 CX35-30B SLP98UH070XV36B 8463547
XC20-024-230 TXV 24000 20 14.5 CX35-36A SL280UH070V36A 8463551
XC20-024-230 TXV 24000 20 14.5 CX35-36A SL280UH070XV36A 8510336
XC20-024-230 TXV 24000 20 14.5 CX35-36B EL296UH045XV36B 8463554
XC20-024-230 TXV 24000 20 14.5 CX35-36B EL296UH070XV36B 8463555
XC20-024-230 TXV 24000 20 14.5 CX35-36B SL280UH090V36B 8463556
XC20-024-230 TXV 24000 20 14.5 CX35-36B SLP98UH070XV36B 8463557
XC20-036-230 TXV 33600 20 12.75 C35-30/36B SLP98UH070XV36B 8462435
XC20-036-230 TXV 33600 20 13 C35-30/36C SLP98UH090XV36C 8462436
XC20-036-230 TXV 35000 20 13 C35-36A SL280UH070V36A 8462437
XC20-036-230 TXV 35000 20 13 C35-36A SL280UH070XV36A 8462438
XC20-036-230 TXV 34800 20 13 C35-36B EL296UH045XV36B 8462439
XC20-036-230 TXV 35000 20 13 C35-36B EL296UH070XV36B 8462440
XC20-036-230 TXV 35200 20 13.5 C35-36B SL280UH090V36B 8462441
XC20-036-230 TXV 35000 20 13.5 C35-36B SL280UH090V48B 8462442
XC20-036-230 TXV 35000 20 13.5 C35-36B SL280UH090XV48B 8462443
XC20-036-230 TXV 35000 20 13 C35-36B SLP98UH070XV36B 8462444
XC20-036-230 TXV 35200 20 13 C35-48B EL296UH045XV36B 8462445
XC20-036-230 TXV 35200 20 13 C35-48B EL296UH070XV36B 8462446
XC20-036-230 TXV 35400 20 14 C35-48B SL280UH090V36B 8510349
XC20-036-230 TXV 35400 20 14 C35-48B SL280UH090V48B 8462448
XC20-036-230 TXV 35400 20 14 C35-48B SL280UH090XV48B 8462449
XC20-036-230 TXV 35200 20 13.5 C35-48B SLP98UH070XV36B 8462450
XC20-036-230 TXV 35400 20 13.5 C35-48C EL296UH090XV36C 8462451
XC20-036-230 TXV 35400 20 14 C35-48C EL296UH090XV48C 8462452
XC20-036-230 TXV 35400 20 14 C35-48C EL296UH110XV48C 8462453
XC20-036-230 TXV 35400 20 14 C35-48C EL296UH110XV60C 8462454
XC20-036-230 TXV 35400 20 14 C35-48C SLP98UH090XV36C 8462455
XC20-036-230 TXV 35400 20 14 C35-48C SLP98UH090XV48C 8462456
XC20-036-230 TXV 35400 20 14 C35-48C SLP98UH090XV60C 10515810
XC20-036-230 TXV 35400 20 14 C35-48C SLP98UH110XV60C 8462457
XC20-036-230 TXV 35200 20 13.5 C35-50/60C EL296UH090XV36C 8462458
XC20-036-230 TXV 35200 20 13.5 C35-50/60C EL296UH090XV48C 8462459
XC20-036-230 TXV 35200 20 13.5 C35-50/60C SLP98UH090XV36C 8462460
XC20-036-230 TXV 35200 20 13.5 C35-50/60C SLP98UH090XV48C 8462461
XC20-036-230 TXV 34400 20 13 CBX32MV-036 8100085
XC20-036-230 TXV 34600 20 13.5 CBX40UHV-036 8100087
XC20-036-230 TXV 33800 20 13 CH23-51 EL296UH045XV36B 8100088
XC20-036-230 TXV 33800 20 13 CH23-51 EL296UH070XV36B 8100090
XC20-036-230 TXV 33800 20 13 CH23-51 EL296UH090XV36C 8100092
XC20-036-230 TXV 34000 20 13 CH23-51 EL296UH090XV48C 8100094
XC20-036-230 TXV 34000 20 13 CH23-51 SL280UH090V36B 8100096
XC20-036-230 TXV 34000 20 13 CH23-51 SL280UH090V48B 8100098
Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

XC20 - 2 to 5 Ton Air Conditioner / Page 12


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Expansion Coil or AHRI
Capacity SEER EER Furnace
No. Device Air Handler Reference
XC20-036-230 TXV 34000 20 13 CH23-51 SL280UH090XV48B 8100099
XC20-036-230 TXV 33800 20 13 CH23-51 SLP98UH070XV36B 8100101
XC20-036-230 TXV 34000 20 13 CH23-51 SLP98UH090XV36C 8100103
XC20-036-230 TXV 34000 20 13 CH23-51 SLP98UH090XV48C 8100105
XC20-036-230 TXV 33400 20 12.5 CH33-36A SL280UH070V36A 9113411
XC20-036-230 TXV 34400 20 13 CH33-42 EL296UH045XV36B 8100107
XC20-036-230 TXV 34400 20 13 CH33-42 EL296UH070XV36B 8100109
XC20-036-230 TXV 34600 20 13.5 CH33-42 SL280UH090V36B 8100110
XC20-036-230 TXV 34600 20 13 CH33-42 SL280UH090V48B 8100112
XC20-036-230 TXV 34600 20 13 CH33-42 SL280UH090XV48B 8100114
XC20-036-230 TXV 34400 20 13 CH33-42 SLP98UH070XV36B 8100116
XC20-036-230 TXV 35400 20 13.5 CH33-43 EL296UH090XV36C 8100118
XC20-036-230 TXV 35400 20 14 CH33-43 EL296UH090XV48C 8100119
XC20-036-230 TXV 35400 20 13.5 CH33-43 SLP98UH090XV36C 8100121
XC20-036-230 TXV 35400 20 14 CH33-43 SLP98UH090XV48C 8100123
XC20-036-230 TXV 35000 20 13 CH33-44/48 EL296UH045XV36B 8100125
XC20-036-230 TXV 35000 20 13 CH33-44/48 EL296UH070XV36B 8100126
XC20-036-230 TXV 35200 20 13.5 CH33-44/48 SL280UH090V36B 8100128
XC20-036-230 TXV 35200 20 13.5 CH33-44/48 SL280UH090V48B 8100130
XC20-036-230 TXV 35200 20 13.5 CH33-44/48 SL280UH090XV48B 8100132
XC20-036-230 TXV 35000 20 13 CH33-44/48 SLP98UH070XV36B 8100134
XC20-036-230 TXV 35200 20 13.5 CH33-48C EL296UH090XV36C 8100136
XC20-036-230 TXV 35200 20 13.5 CH33-48C EL296UH090XV48C 8086455
XC20-036-230 TXV 35200 20 13.5 CH33-48C SLP98UH090XV36C 8086456
XC20-036-230 TXV 35200 20 13.5 CH33-48C SLP98UH090XV48C 8086457
XC20-036-230 TXV 35600 20 14 CH35-42C EL296UH090XV36C 8086502
XC20-036-230 TXV 35600 20 14 CH35-42C EL296UH090XV48C 8086503
XC20-036-230 TXV 35600 20 14 CH35-42C SLP98UH090XV36C 8086504
XC20-036-230 TXV 35600 20 14 CH35-42C SLP98UH090XV48C 8086505
XC20-036-230 TXV 35200 20 13 CH35-48B EL296UH045XV36B 8086506
XC20-036-230 TXV 35200 20 13.5 CH35-48B EL296UH070XV36B 8086507
XC20-036-230 TXV 35400 20 14 CH35-48B SL280UH090V36B 8086508
XC20-036-230 TXV 35400 20 14 CH35-48B SL280UH090V48B 8086509
XC20-036-230 TXV 35400 20 14 CH35-48B SL280UH090XV48B 8086510
XC20-036-230 TXV 35200 20 13.5 CH35-48B SLP98UH070XV36B 8086511
XC20-036-230 TXV 35400 20 13.5 CH35-48C EL296UH090XV36C 8086512
XC20-036-230 TXV 35400 20 14 CH35-48C EL296UH090XV48C 8086513
XC20-036-230 TXV 35400 20 13.5 CH35-48C SLP98UH090XV36C 8086514
XC20-036-230 TXV 35400 20 14 CH35-48C SLP98UH090XV48C 8086515
XC20-036-230 TXV 34400 20 13 CR33-48 EL296DF045XV36B 8086458
XC20-036-230 TXV 34400 20 13 CR33-48 EL296DF070XV48B 8086459
XC20-036-230 TXV 34600 20 13 CR33-48 SL280DF090V48B 8086460
XC20-036-230 TXV 34400 20 13 CR33-48 SLP98DF070XV36B 8086462
XC20-036-230 TXV 34400 20 13 CR33-48 SLP98DF090XV36C 8086463
XC20-036-230 TXV 34400 20 13 CR33-48 SLP98DF090XV48C 8086464
XC20-036-230 TXV 33800 20 12.75 CX35-30/36B SLP98UH070XV36B 8463512
XC20-036-230 TXV 33800 20 13 CX35-30/36C SLP98UH090XV36C 8463513
Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

XC20 - 2 to 5 Ton Air Conditioner / Page 13


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Expansion Coil or AHRI
Capacity SEER EER Furnace
No. Device Air Handler Reference
XC20-036-230 TXV 35200 20 13 CX35-36A SL280UH070V36A 8463514
XC20-036-230 TXV 35200 20 13 CX35-36A SL280UH070XV36A 8463515
XC20-036-230 TXV 35200 20 13 CX35-36B EL296UH045XV36B 8463516
XC20-036-230 TXV 35200 20 13 CX35-36B EL296UH070XV36B 8463517
XC20-036-230 TXV 35400 20 14 CX35-36B SL280UH090V36B 8510350
XC20-036-230 TXV 35400 20 13.5 CX35-36B SL280UH090V48B 8463519
XC20-036-230 TXV 35400 20 13.5 CX35-36B SL280UH090XV48B 8463520
XC20-036-230 TXV 35200 20 13 CX35-36B SLP98UH070XV36B 8463521
XC20-036-230 TXV 35200 20 13 CX35-48B EL296UH045XV36B 8463522
XC20-036-230 TXV 35200 20 13 CX35-48B EL296UH070XV36B 8463523
XC20-036-230 TXV 35400 20 14 CX35-48B SL280UH090V36B 8463524
XC20-036-230 TXV 35400 20 14 CX35-48B SL280UH090V48B 8463525
XC20-036-230 TXV 35400 20 14 CX35-48B SL280UH090XV48B 8463526
XC20-036-230 TXV 35200 20 13.5 CX35-48B SLP98UH070XV36B 8463527
XC20-036-230 TXV 35400 20 13.5 CX35-48C EL296UH090XV36C 8463528
XC20-036-230 TXV 35600 20 14 CX35-48C EL296UH090XV48C 8463529
XC20-036-230 TXV 35600 20 14 CX35-48C EL296UH110XV48C 8463530
XC20-036-230 TXV 35600 20 14 CX35-48C EL296UH110XV60C 8463531
XC20-036-230 TXV 35400 20 14 CX35-48C SLP98UH090XV36C 9108420
XC20-036-230 TXV 35600 20 14 CX35-48C SLP98UH090XV48C 8463533
XC20-036-230 TXV 35400 20 14 CX35-48C SLP98UH090XV60C 10515811
XC20-036-230 TXV 35600 20 14 CX35-48C SLP98UH110XV60C 8463534
XC20-036-230 TXV 35200 20 13.5 CX35-50/60C EL296UH090XV36C 8463535
XC20-036-230 TXV 35200 20 13.5 CX35-50/60C EL296UH090XV48C 8463536
XC20-036-230 TXV 35200 20 13.5 CX35-50/60C SLP98UH090XV36C 8463537
XC20-036-230 TXV 35200 20 13.5 CX35-50/60C SLP98UH090XV48C 8463538
XC20-048-230 TXV 46000 19 12 C35-48B SL280UH090V48B 8462471
XC20-048-230 TXV 46000 19 12 C35-48B SL280UH090XV48B 8510362
XC20-048-230 TXV 46000 19 12 C35-48C EL296UH090XV48C 8462472
XC20-048-230 TXV 46000 19 12 C35-48C EL296UH090XV60C 8462473
XC20-048-230 TXV 46000 19.5 12.5 C35-48C EL296UH110XV48C 8462474
XC20-048-230 TXV 46000 19.5 12.5 C35-48C EL296UH110XV60C 8462475
XC20-048-230 TXV 46000 19 12.5 C35-48C SL280UH090V60C 8462476
XC20-048-230 TXV 46000 19 12.5 C35-48C SL280UH090XV60C 8510363
XC20-048-230 TXV 46000 19 12.5 C35-48C SL280UH110V60C 8462477
XC20-048-230 TXV 46000 19 12.5 C35-48C SL280UH110XV60C 8510364
XC20-048-230 TXV 46000 19.5 12.5 C35-48C SLP98UH090XV48C 8462478
XC20-048-230 TXV 46000 19.5 12.5 C35-48C SLP98UH090XV60C 8462479
XC20-048-230 TXV 46000 19.5 12.5 C35-48C SLP98UH110XV60C 8462480
XC20-048-230 TXV 46500 19 12.5 C35-49C EL296UH090XV48C 8462462
XC20-048-230 TXV 46500 19 12.5 C35-49C EL296UH090XV60C 8462463
XC20-048-230 TXV 46500 18.5 12 C35-49C EL296UH110XV48C 8462464
XC20-048-230 TXV 46500 19 12.2 C35-49C EL296UH110XV60C 8462465
XC20-048-230 TXV 46500 18.5 12 C35-49C SL280UH090V60C 8462466
XC20-048-230 TXV 46500 18.5 12 C35-49C SL280UH090XV60C 8510360
XC20-048-230 TXV 46500 19 12 C35-49C SL280UH110V60C 8510361
XC20-048-230 TXV 46500 19 12 C35-49C SL280UH110XV60C 8462467
Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

XC20 - 2 to 5 Ton Air Conditioner / Page 14


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Expansion Coil or AHRI
Capacity SEER EER Furnace
No. Device Air Handler Reference
XC20-048-230 TXV 46500 19 12 C35-49C SLP98UH090XV48C 8462468
XC20-048-230 TXV 46500 18.5 12 C35-49C SLP98UH090XV60C 8462469
XC20-048-230 TXV 46500 19 12.5 C35-49C SLP98UH110XV60C 8462470
XC20-048-230 TXV 45500 19 12.2 C35-50/60C EL296UH090XV48C 8462481
XC20-048-230 TXV 45500 19 12.2 C35-50/60C EL296UH090XV60C 8462482
XC20-048-230 TXV 45500 19 12.2 C35-50/60C EL296UH110XV48C 8462483
XC20-048-230 TXV 45500 19 12.2 C35-50/60C EL296UH110XV60C 8462484
XC20-048-230 TXV 45500 19 12.5 C35-50/60C SL280UH090V60C 8462485
XC20-048-230 TXV 45500 19 12.5 C35-50/60C SL280UH090XV60C 8510365
XC20-048-230 TXV 45500 19 12.2 C35-50/60C SL280UH110V60C 8462486
XC20-048-230 TXV 45500 19 12.2 C35-50/60C SL280UH110XV60C 8510366
XC20-048-230 TXV 45500 19 12.2 C35-50/60C SLP98UH090XV48C 8462487
XC20-048-230 TXV 45500 19 12.2 C35-50/60C SLP98UH090XV60C 8462488
XC20-048-230 TXV 45500 19 12.2 C35-50/60C SLP98UH110XV60C 8462489
XC20-048-230 TXV 46000 20 13 CBX32MV-048 8086363
XC20-048-230 TXV 46500 20 13 CBX32MV-060 8086364
XC20-048-230 TXV 46000 19.5 12.5 CBX40UHV-048 8086365
XC20-048-230 TXV 46500 19.5 13 CBX40UHV-060 8086366
XC20-048-230 TXV 45000 18.5 12.5 CH23-65 SL280UH090V60C 10260326
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 EL296UH090XV48C 8086367
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 EL296UH090XV60C 8086368
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 EL296UH110XV48C 8086369
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 EL296UH110XV60C 8086370
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 SL280UH090V60C 8086371
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 SL280UH090XV60C 8203214
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 SL280UH110V60C 8086372
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 SL280UH110XV60C 8203210
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 SLP98UH090XV48C 8086373
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 SLP98UH090XV60C 8086374
XC20-048-230 TXV 46500 19.5 12.5 CH33-49 SLP98UH110XV60C 8086375
XC20-048-230 TXV 46000 19 12.5 CH33-50/60C EL296UH090XV48C 8086376
XC20-048-230 TXV 46000 19 12.5 CH33-50/60C EL296UH090XV60C 8086377
XC20-048-230 TXV 46000 19 12.5 CH33-50/60C EL296UH110XV48C 8086378
XC20-048-230 TXV 46000 19 12.5 CH33-50/60C EL296UH110XV60C 8086379
XC20-048-230 TXV 46500 19.5 12.5 CH33-50/60C SL280UH090V60C 8086380
XC20-048-230 TXV 46500 19.5 12.5 CH33-50/60C SL280UH090XV60C 8203211
XC20-048-230 TXV 46000 19 12.5 CH33-50/60C SL280UH110V60C 8086381
XC20-048-230 TXV 46000 19 12.5 CH33-50/60C SL280UH110XV60C 8203212
XC20-048-230 TXV 46000 19.5 12.5 CH33-50/60C SLP98UH090XV48C 8086382
XC20-048-230 TXV 46000 19 12.5 CH33-50/60C SLP98UH090XV60C 8086383
XC20-048-230 TXV 46000 19 12.5 CH33-50/60C SLP98UH110XV60C 8086384
XC20-048-230 TXV 46000 19 12.5 CH33-60D EL296UH135XV60D 8086385
XC20-048-230 TXV 46000 19 12.5 CH33-60D SL280UH135V60D 8086386
XC20-048-230 TXV 46000 19 12.5 CH33-60D SLP98UH135XV60D 8086387
XC20-048-230 TXV 46500 19 12.5 CH33-62D EL296UH135XV60D 8086388
XC20-048-230 TXV 46500 19.5 13 CH33-62D SL280UH135V60D 8086389
XC20-048-230 TXV 46500 19 12.5 CH33-62D SLP98UH135XV60D 8086390
Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

XC20 - 2 to 5 Ton Air Conditioner / Page 15


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Expansion Coil or AHRI
Capacity SEER EER Furnace
No. Device Air Handler Reference
XC20-048-230 TXV 46500 19.5 12.5 CH35-51C EL296UH090XV48C 8086391
XC20-048-230 TXV 46500 19.5 12.5 CH35-51C EL296UH090XV60C 8086392
XC20-048-230 TXV 46500 19.5 12.5 CH35-51C EL296UH110XV48C 8086393
XC20-048-230 TXV 46500 19.5 12.5 CH35-51C EL296UH110XV60C 8086394
XC20-048-230 TXV 47000 19.5 13 CH35-51C SL280UH090V60C 8086395
XC20-048-230 TXV 47000 19.5 13 CH35-51C SL280UH090XV60C 8203213
XC20-048-230 TXV 46500 19 12.5 CH35-51C SL280UH110V60C 8086396
XC20-048-230 TXV 46500 19 12.5 CH35-51C SL280UH110XV60C 8510356
XC20-048-230 TXV 46500 19.5 12.5 CH35-51C SLP98UH090XV48C 8086397
XC20-048-230 TXV 46500 19.5 12.5 CH35-51C SLP98UH090XV60C 8086398
XC20-048-230 TXV 46500 19.5 12.5 CH35-51C SLP98UH110XV60C 8086399
XC20-048-230 TXV 46500 19 12.5 CH35-60D EL296UH135XV60D 8086400
XC20-048-230 TXV 46500 19.5 13 CH35-60D SL280UH135V60D 8086401
XC20-048-230 TXV 46500 19 12.5 CH35-60D SLP98UH135XV60D 8086402
XC20-048-230 TXV 46000 19 12.5 CR33-50/60 EL296DF090XV60C 8086403
XC20-048-230 TXV 46000 19 12.5 CR33-50/60 EL296DF110XV60C 8086404
XC20-048-230 TXV 46500 19.5 12.2 CR33-50/60 SL280DF090V60C 8510352
XC20-048-230 TXV 46500 19.5 12.2 CR33-50/60 SL280DF110V60C 8086406
XC20-048-230 TXV 46000 19 12.2 CR33-50/60 SLP98DF090XV48C 8086407
XC20-048-230 TXV 46000 19 12.5 CR33-50/60 SLP98DF090XV60C 8086408
XC20-048-230 TXV 46000 19 12.5 CR33-50/60 SLP98DF110XV60C 8086409
XC20-048-230 TXV 46000 19 12.5 CR33-60 EL296DF090XV60C 8086410
XC20-048-230 TXV 46000 19 12.5 CR33-60 EL296DF110XV60C 8086411
XC20-048-230 TXV 46500 19 12.2 CR33-60 SL280DF090V60C 8086412
XC20-048-230 TXV 46500 19.5 12.2 CR33-60 SL280DF110V60C 8086413
XC20-048-230 TXV 46000 19 12.2 CR33-60 SLP98DF090XV48C 8086414
XC20-048-230 TXV 46000 19 12.5 CR33-60 SLP98DF090XV60C 8086415
XC20-048-230 TXV 46000 19 12.5 CR33-60 SLP98DF110XV60C 8086416
XC20-048-230 TXV 46000 19 12.5 CX35-48B SL280UH090V48B 8463493
XC20-048-230 TXV 46000 19 12.5 CX35-48B SL280UH090XV48B 8510367
XC20-048-230 TXV 46000 19.5 12.5 CX35-48C EL296UH090XV48C 8463494
XC20-048-230 TXV 46000 19.5 12.5 CX35-48C EL296UH090XV60C 8463495
XC20-048-230 TXV 46000 19.5 12.5 CX35-48C EL296UH110XV48C 8463496
XC20-048-230 TXV 46000 19.5 12.5 CX35-48C EL296UH110XV60C 8463497
XC20-048-230 TXV 46000 19.5 12.5 CX35-48C SL280UH090V60C 8463498
XC20-048-230 TXV 46000 19.5 12.5 CX35-48C SL280UH090XV60C 8510368
XC20-048-230 TXV 46000 19 12.5 CX35-48C SL280UH110V60C 8463499
XC20-048-230 TXV 46000 19 12.5 CX35-48C SL280UH110XV60C 8510369
XC20-048-230 TXV 46000 19.5 12.5 CX35-48C SLP98UH090XV48C 8463500
XC20-048-230 TXV 46000 19.5 12.5 CX35-48C SLP98UH090XV60C 8463501
XC20-048-230 TXV 46000 19.5 12.5 CX35-48C SLP98UH110XV60C 8463502
XC20-048-230 TXV 46500 19.5 12.5 CX35-49C EL296UH090XV48C 8463484
XC20-048-230 TXV 46500 19 12.5 CX35-49C EL296UH090XV60C 8463485
XC20-048-230 TXV 46500 19.5 12.5 CX35-49C EL296UH110XV48C 8463486
XC20-048-230 TXV 46500 19 12.5 CX35-49C EL296UH110XV60C 8463487
XC20-048-230 TXV 46500 19.5 13 CX35-49C SL280UH090V60C 8463488
XC20-048-230 TXV 46500 19.5 13 CX35-49C SL280UH090XV60C 8510358
Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

XC20 - 2 to 5 Ton Air Conditioner / Page 16


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Expansion Coil or AHRI
Capacity SEER EER Furnace
No. Device Air Handler Reference
XC20-048-230 TXV 46500 19 12.5 CX35-49C SL280UH110V60C 8463489
XC20-048-230 TXV 46500 19 12.5 CX35-49C SL280UH110XV60C 8510359
XC20-048-230 TXV 46500 19.5 12.5 CX35-49C SLP98UH090XV48C 8463490
XC20-048-230 TXV 46500 19 12.5 CX35-49C SLP98UH090XV60C 8463491
XC20-048-230 TXV 46500 19 12.5 CX35-49C SLP98UH110XV60C 8463492
XC20-048-230 TXV 45500 19 12.2 CX35-50/60C EL296UH090XV48C 8463503
XC20-048-230 TXV 45500 19 12.2 CX35-50/60C EL296UH090XV60C 8463504
XC20-048-230 TXV 45500 19 12.2 CX35-50/60C EL296UH110XV48C 8463505
XC20-048-230 TXV 45500 19 12.2 CX35-50/60C EL296UH110XV60C 8463506
XC20-048-230 TXV 45500 19 12.5 CX35-50/60C SL280UH090V60C 8463507
XC20-048-230 TXV 45500 19 12.5 CX35-50/60C SL280UH090XV60C 8510390
XC20-048-230 TXV 45500 19 12.2 CX35-50/60C SL280UH110V60C 8463508
XC20-048-230 TXV 45500 19 12.2 CX35-50/60C SL280UH110XV60C 8510391
XC20-048-230 TXV 45500 19 12.2 CX35-50/60C SLP98UH090XV48C 8463509
XC20-048-230 TXV 45500 19 12.2 CX35-50/60C SLP98UH090XV60C 8463510
XC20-048-230 TXV 45500 19 12.2 CX35-50/60C SLP98UH110XV60C 8463511
XC20-048-230 TXV 46500 19 12.5 CX35-60D EL296UH135XV60D 9060114
XC20-060-230 TXV 57000 19 12.5 C35-49C EL296UH090XV60C 8462490
XC20-060-230 TXV 57000 19 12.5 C35-49C EL296UH110XV60C 8462491
XC20-060-230 TXV 57000 19 13 C35-49C SL280UH090V60C 8462492
XC20-060-230 TXV 57000 19 13 C35-49C SL280UH090XV60C 8510374
XC20-060-230 TXV 57000 19 12.5 C35-49C SL280UH110V60C 8462493
XC20-060-230 TXV 57000 19 12.5 C35-49C SL280UH110XV60C 8510375
XC20-060-230 TXV 57000 19 12.5 C35-49C SLP98UH090XV60C 8462494
XC20-060-230 TXV 57000 19 12.5 C35-49C SLP98UH110XV60C 8462495
XC20-060-230 TXV 58000 19 12.75 C35-60C EL296UH090XV60C 8462496
XC20-060-230 TXV 58000 19 12.75 C35-60C EL296UH110XV60C 8462497
XC20-060-230 TXV 58500 19 13 C35-60C SL280UH090V60C 8462498
XC20-060-230 TXV 58500 19 13 C35-60C SL280UH090XV60C 8510376
XC20-060-230 TXV 58500 19 13 C35-60C SL280UH110V60C 8462499
XC20-060-230 TXV 58500 19 13 C35-60C SL280UH110XV60C 8510377
XC20-060-230 TXV 58000 19 12.75 C35-60C SLP98UH090XV60C 8462500
XC20-060-230 TXV 58000 19 13 C35-60C SLP98UH110XV60C 8462501
XC20-060-230 TXV 57500 19 13 C35-60D EL296UH135XV60D 8462502
XC20-060-230 TXV 58000 19 13 C35-60D SL280UH135V60D 8462503
XC20-060-230 TXV 57500 19 13 C35-60D SLP98UH135XV60D 8462504
XC20-060-230 TXV 57000 19 13 CBX32MV-060 8086274
XC20-060-230 TXV 56500 19 13 CBX40UHV-060 8086275
XC20-060-230 TXV 54500 19 12 CH23-65 SL280UH090V60C 10260327
XC20-060-230 TXV 56500 19 12.2 CH33-49 EL296UH090XV60C 8086276
XC20-060-230 TXV 57000 19 12.5 CH33-49 EL296UH110XV60C 8086277
XC20-060-230 TXV 57000 19 12.5 CH33-49 SL280UH090V60C 8086278
XC20-060-230 TXV 57000 19 12.5 CH33-49 SL280UH090XV60C 8203221
XC20-060-230 TXV 57000 19 12.5 CH33-49 SL280UH110V60C 8086279
XC20-060-230 TXV 57000 19 12.5 CH33-49 SL280UH110XV60C 8203222
XC20-060-230 TXV 56500 19 12.2 CH33-49 SLP98UH090XV60C 8086280
XC20-060-230 TXV 57000 19 12.5 CH33-49 SLP98UH110XV60C 8086281
Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

XC20 - 2 to 5 Ton Air Conditioner / Page 17


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Expansion Coil or AHRI
Capacity SEER EER Furnace
No. Device Air Handler Reference
XC20-060-230 TXV 56500 19 12.2 CH33-50/60C EL296UH090XV60C 8086282
XC20-060-230 TXV 56500 19 12.2 CH33-50/60C EL296UH110XV60C 8086283
XC20-060-230 TXV 56500 19 12.5 CH33-50/60C SL280UH090V60C 8086284
XC20-060-230 TXV 56500 19 12.5 CH33-50/60C SL280UH090XV60C 8203223
XC20-060-230 TXV 56500 19 12.5 CH33-50/60C SL280UH110V60C 8086285
XC20-060-230 TXV 56500 19 12.5 CH33-50/60C SL280UH110XV60C 8203224
XC20-060-230 TXV 56500 19 12.2 CH33-50/60C SLP98UH090XV60C 8086286
XC20-060-230 TXV 56500 19 12.2 CH33-50/60C SLP98UH110XV60C 8086287
XC20-060-230 TXV 56000 19 12.5 CH33-60D EL296UH135XV60D 8086288
XC20-060-230 TXV 56000 19 12.5 CH33-60D SL280UH135V60D 8086289
XC20-060-230 TXV 56000 19 12.5 CH33-60D SLP98UH135XV60D 8086290
XC20-060-230 TXV 57000 19 12.75 CH33-62D EL296UH135XV60D 8086291
XC20-060-230 TXV 57000 19 13 CH33-62D SL280UH135V60D 8086292
XC20-060-230 TXV 57000 19 12.75 CH33-62D SLP98UH135XV60D 8086293
XC20-060-230 TXV 57000 19 12.5 CH35-51C EL296UH090XV60C 8086294
XC20-060-230 TXV 57000 19 12.5 CH35-51C EL296UH110XV60C 8086295
XC20-060-230 TXV 57500 19 12.75 CH35-51C SL280UH090V60C 8086296
XC20-060-230 TXV 57500 19 12.75 CH35-51C SL280UH090XV60C 8203219
XC20-060-230 TXV 57000 19 12.5 CH35-51C SL280UH110V60C 8086297
XC20-060-230 TXV 57000 19 12.5 CH35-51C SL280UH110XV60C 8203220
XC20-060-230 TXV 57000 19 12.5 CH35-51C SLP98UH090XV60C 8086298
XC20-060-230 TXV 57000 19 12.5 CH35-51C SLP98UH110XV60C 8086299
XC20-060-230 TXV 57000 19 13 CH35-60D EL296UH135XV60D 8086300
XC20-060-230 TXV 57000 19 13 CH35-60D SL280UH135V60D 8086301
XC20-060-230 TXV 57000 19 13 CH35-60D SLP98UH135XV60D 8086302
XC20-060-230 TXV 55500 19 12.5 CR33-50/60 SL280DF110V60C 9060115
XC20-060-230 TXV 55000 19 12 CR33-60 EL296DF090XV60C 8203103
XC20-060-230 TXV 55000 19 12 CR33-60 EL296DF110XV60C 8203104
XC20-060-230 TXV 55500 19 12.5 CR33-60 SL280DF090V60C 8086305
XC20-060-230 TXV 55500 19 12.5 CR33-60 SL280DF110V60C 8086306
XC20-060-230 TXV 55000 19 12 CR33-60 SLP98DF090XV60C 8203105
XC20-060-230 TXV 55000 19 12 CR33-60 SLP98DF110XV60C 8203106
XC20-060-230 TXV 57000 19 12.5 CX35-49C EL296UH090XV60C 8463469
XC20-060-230 TXV 57000 19 12.5 CX35-49C EL296UH110XV60C 8463470
XC20-060-230 TXV 57000 19 13 CX35-49C SL280UH090V60C 8463471
XC20-060-230 TXV 57000 19 13 CX35-49C SL280UH090XV60C 8510381
XC20-060-230 TXV 57000 19 12.5 CX35-49C SL280UH110V60C 8463472
XC20-060-230 TXV 57000 19 12.5 CX35-49C SL280UH110XV60C 8510382
XC20-060-230 TXV 57000 19 12.5 CX35-49C SLP98UH090XV60C 8463473
XC20-060-230 TXV 57000 19 12.5 CX35-49C SLP98UH110XV60C 8463474
XC20-060-230 TXV 58000 19 12.75 CX35-60C EL296UH090XV60C 8463475
XC20-060-230 TXV 58000 19 12.75 CX35-60C EL296UH110XV60C 8463476
XC20-060-230 TXV 58500 19 13 CX35-60C SL280UH090V60C 8463477
XC20-060-230 TXV 58500 19 13 CX35-60C SL280UH090XV60C 8510383
XC20-060-230 TXV 58500 19 13 CX35-60C SL280UH110V60C 8463478
XC20-060-230 TXV 58500 19 13 CX35-60C SL280UH110XV60C 8510384
XC20-060-230 TXV 58000 19 12.75 CX35-60C SLP98UH090XV60C 8463479
Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

XC20 - 2 to 5 Ton Air Conditioner / Page 18


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Expansion Coil or AHRI
Capacity SEER EER Furnace
No. Device Air Handler Reference
XC20-060-230 TXV 58000 19 13 CX35-60C SLP98UH110XV60C 8463480
XC20-060-230 TXV 57500 19 13 CX35-60D EL296UH135XV60D 8463481
XC20-060-230 TXV 58000 19 13 CX35-60D SL280UH135V60D 8463482
XC20-060-230 TXV 57500 19 13 CX35-60D SLP98UH135XV60D 8463483
Ratings AHRI Certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
Also see Expansion Valve Kit Usage Table.

XC20 - 2 to 5 Ton Air Conditioner / Page 19


REVISIONS
Sections Description of Change

AHRI System Matches Updated.

Visit us at www.lennox.com
For the latest technical information, www.LennoxPROs.com
Contact us at 1-800-4-LENNOX

NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency. ©2017 Lennox Industries, Inc.

You might also like