0% found this document useful (0 votes)
46 views15 pages

HEAT EXCHANGE1 Yuyun

The document discusses heat exchanger experiments using a shell and tube heat exchanger. It includes: 1) Objectives to understand heat transfer from a fluid. 2) Experimental setup using a shell and tube heat exchanger and computer to collect data. 3) Temperature data collected from the hot and cold fluid inlet and outlets, including flowrates. 4) Calculations of heat transfer rates, mean temperature difference, surface areas, and Reynolds number.

Uploaded by

Widi Aprilia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views15 pages

HEAT EXCHANGE1 Yuyun

The document discusses heat exchanger experiments using a shell and tube heat exchanger. It includes: 1) Objectives to understand heat transfer from a fluid. 2) Experimental setup using a shell and tube heat exchanger and computer to collect data. 3) Temperature data collected from the hot and cold fluid inlet and outlets, including flowrates. 4) Calculations of heat transfer rates, mean temperature difference, surface areas, and Reynolds number.

Uploaded by

Widi Aprilia
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 15

HEAT EXCHANGER

I. TUJUAN
Untuk mengetahui perpindahan panas dari suatu fluida

II. ALAT DAN BAHAN


 ALAT :
- Shell and Tube
- Komputer
 BAHAN :
- Air

III. DASAR TEORI

IV. PROSEDUR KERJA

V. DATA HASIL PENGAMATAN


Suhu fluida panas masuk = 60oC
Laju alir = 3 L/menit

Temp Temp Temp Temp Hot water Hot water Cold water Cold water
T1 T2 T3 T4 Pump Flowratehot Pump setting Flowratecold
o
( C) o
( C) o
( C) o
( C) setting L (%) L
( ) ( )
(%) min min
61,1 58,9 27,1 40,2 34,6 3,1 50,0 0,6
60,1 57,3 27,2 36,2 34,8 3,0 60,0 1,0

VI. PERHITUNGAN
Suhu Fluida Dingin Keluar
Data I :
9
T4 = 5 (40,2) + 32

T1 = 104.36oF
Data II :
9
T4 = 5 (36,2) + 32

T1 = 97.16oF

Temp Temp Temp Temp


T1 T2 T3 T4
(oF) (oF) (oF) (oF)
141.98 138.02 80.78 104.36
140.18 135.14 80.96 97.16

Ket :
T1 = T1 = Suhu fluida panas masuk
T2 = T2 = Suhu fluida panas keluar
T3 = t1 = Suhu fluida dingin masuk
T4 = t2 = Suhu fluida dingin keluar

a. T average untuk mendapatkan nilai Cpp dan Cpd menggunakan grafik


pada fig.2
Fluida Panas
Data I :
T1 + T2
Tav p = 2
141.98o F +138.02o F
Tav p = 2
o
Tav p = 140 F

Data II :
T1 + T2
Tav p = 2
140.18o F +135.14o F
Tav p = 2

Tav p = 207.75oF

Taverge Taverage Cp p Cp d
Tavp Tavd BTU BTU
( lb F ) ( lb F )
(oF) (oF)
210.99 132.96 1,009 1,003
207.75 129.54 1.010 1,005
b. Menghitung Qp dan Qd
 Qp = Wp x Cp x ∆Tp
lb BTU
Qp = 409.69163 hr x 1,009 lb F x (141.98oF –138.02oF )
BTU
= 1636,98
hr

 Qd = Wd x Cd x ∆T

lb BTU
Qp = 66,08hr x 1.01 x (108,86oF –81,86oF )
lb F

BTU
Qp = 1802 hr

Wp Wd Cp Cd Qp Qd
lb lb BTU BTU ∆Tp ∆Td BTU BTU
( ) ( ) ( ) ( ) (oF) (oF) ( ) ( )
hr hr lb F lb F hr hr
79.2951541 3.9 23.5
409.69163
9 1,009 1,003 6 8 1636,98 1875,39
396.475770 132.158590 5.0
9 3 1.010 1,005 4 16.2 2018,22 2151,67

c. LMTD
(T2 − t1 ) − (T1 − t2 )
LMTD = T −t
ln 2 1
T1 − t2

(138.02o F− 80.78o F ) − (141.98o F −104.36o F )


LMTD = 138.02o F− 80.78o F
ln
141.98o F −104.36o F

(57,24o F) – (37.62o F)
LMTD = 57.24o F
ln
37.62o F

19.62o F
LMTD = ln 1,522
19.62o F
LMTD = 0,419

LMTD = 46,75oF
Temp Temp Temp Temp
T2 – t1 T1 – t2
T1 T2 t1 t2 T2 – t1 LMTD
Ln(T1 – t2)
o
( F) o
( F) (oF)
(oF) (oF) (oF) (oF)
141.98 138.02 80.78 104.36 57.24 57.24 37.62 46.75
140.18 135.14 80.96 97.16 54.18 54.18 43.02 48.39

d. Mencari Luas
Dik :
di = Diameter dalam pipa kecil (Tubes) = 0,005 m0,3048 m
do = Diameter luar pipa kecil (Tubes) = 0,006 m
Di = Diameter dalam pipa besar (Shell) = 3,5 cm = 0,035 m
L = Panjang pipa = 1,0008 m

1. Luas Annulus (Aa)

π(Di2 −do2 )
Aa = 4
3,14 ((0,035 m)2 −(0,006 m)2 )
Aa = 4
3,14 (122,5 x 10−5 m2 − 3,6 x 10−5 m2 )
Aa = 4
3,14(118,9 x 10−5 m2 )
Aa = 4

Aa = 9,33 x 10-4 m2

Satuan Aa dikonversi dari m2 ke ft2 sehingga diperoleh :


10,7639 ft2
(9,33 x 10-4 m2) x ( ) = 0,010043 ft2
1 m2

Di2 −do2
De = do
(0,035 m)2 −(0,006 m)2
De = 0,006 m
122,5 x 10−5 m2 − 3,6 x 10−5 m2
De = 0,006 m

118,9 x 10−5 m2
De = 0,006 m

De = 0,198 m

Satuan De dikonversi dari m ke ft sehingga diperoleh :


3,2808 ft
0,19 m x ( ) = 0,6234 ft
1m

2. Luas Pipa (Ap)

πdi2
Aa = 4

3,14 × (0,005 m)2


Aa = 4

3,14 ×2,5 ×10−5 m2


Aa = 4

7,85 × 10−5 m2
Aa = 4

Aa = 1,96 x 10-5 m2

Satuan Ap dikonversi dari m2 ke ft2 sehingga diperoleh :


10,7639 ft2
(1,96 x 10-5 m2) x ( ) = 0,000211 ft2
1 m2

e. Menghitung Nilai G
1. Nilai G Annulus (Ga)
Wd
Ga = Aa
lb
79.29515419
hr
Ga= 0,010043 ft2
lb
Ga= 7895.564492hr.ft2

Wd (lb/hr) Aa (m2) Aa (ft2) Ga (lb/hr.ft2)


79.29515419 0.000933 0.010043 7895.564492
132.1585903 0.000933 0.010043 13159.27415
2. Nila G Pipa (Gp)
Wp
Ga = Ap

lb
409.69163
hr
= 0,000211 ft2

lb
= 1941666.493hr.ft2

Wp (lb/hr) Ap (m2) Ap (ft2) Gp (lb/hr.ft2)


409.69163 0.0000196 0.000211 1941666.493
396.47577 0.0000196 0.000211 1879032.085

f. Menentukan Bilangan Reynold (NRe) :


1. Bilangan Reynold Annulus (NRea) :
De ×Ga
Rea =
μd

μ diperoleh dari grafik. Namun hal viskositas dalam hal ini diperoleh
berdasarkan Tav d yang telah diperoleh, yaitu :
Taverage Tavd (oF)
132.96
129.54

Untuk mendapatkan hasil yang pasti dari viskositas yang diperoleh dari nilai
Tav d maka dalam hal ini perlu dilakukan interpolasi. Untuk itu, contoh
perhitungan interpolasi dilakukan terhadap data I (Tav d I) dengan suhu
132,96 oF. Maka perlu dilakukan interpolasi dengan data yang tersedia yaitu
:
Taverage Tavd (oF) Visositas 𝛍 (cp)
130 0,55
140 0,5

y = Viskositas (cp)
x = Temperatur (oF)

x−x1
y = y1 + (y2 − y1)
x2−x1
132,96 ℉−130 ℉
y = 0,55 cp + (0,5 − 0,55)cp
140℉−130℉
132,96 ℉−130 ℉
y = 0,55 cp + (0,5 − 0,55)cp
140℉−130℉
2,96 ℉
y = 0,55 cp + (−0,05cp)
10℉

y = 0,55 cp + 0,296 (−0,05cp)


y = 0,55 cp + (−0,0148 cp)
y = 0,5352 cp

Sama halnya dengan data kedua, perlu dilakukan interpolasi. Sehingga


diperoleh viskositas sebagai berikut :

Taverage Tavd (oF) Visositas 𝛍 (cp)

132.96 0,5352

129.54 0,5523

Konversi satuan dari viskositas yang diperoleh, dari satua cp ke satuan


lb/ft.hr.
kg lb
0,001 2419,2 lb
m.s ft.hr
0,5352 cp × × kg = 1,295
1 cp 1 ft.hr
m.s

Taverage Tavd (oF) Visositas 𝛍 (cp) Visositas 𝛍 (lb/ft.hr)

132.96 0,5352 1,295

129.54 0,5523 1,336

De ×Ga
Rea = μd
lb
0,6234 ft × 7895.564492
hr.ft2
Rea = lb
1,295
ft.hr

Rea = 3800.85

De (ft) Ga (lb/hr.ft2) Visositas 𝛍 (lb/ft.hr) NRea


0.6234 7895.5645 1.295 3800.85
0.6234 13159.274 1.336 6140.34

2. Bilangan Reynold Pipa (NRep):


di ×Gp
Rep = μp

μ diperoleh dari grafik. Namun hal viskositas dalam hal ini diperoleh
berdasarkan Tav p yang telah diperoleh, yaitu :
Taverage Tavp (oF)
210.99
207.75

Untuk mendapatkan hasil yang pasti dari viskositas yang diperoleh dari nilai
Tav p maka dalam hal ini perlu dilakukan interpolasi. Untuk itu, contoh
perhitungan interpolasi dilakukan terhadap data I (Tav p I) dengan suhu
210.99 oF. Maka perlu dilakukan interpolasi dengan data yang tersedia yaitu:

Taverage TavP (oF) Visositas 𝛍 (cp)


210 0,26
220 0,24

y = Viskositas (cp)
x = Temperatur (oF)

x−x1
y = y1 + (y2 − y1)
x2−x1
210,99 ℉−210 ℉
y = 0,26 cp + (0,24 − 0,26)cp
220℉−210℉
0,99 ℉
y = 0,26 cp + (−0,02 cp)
10℉

y = 0,26 cp + 0,099 (−0,02 cp)


y = 0,26 cp + (−0,00198 cp)
y = 0,26 cp − 0,0148 cp)
y = 0,2580 cp
Sama halnya dengan data kedua, perlu dilakukan interpolasi. Sehingga
diperoleh viskositas sebagai berikut :

Taverage TavP (oF) Visositas 𝛍 (cp)

210.99 0,2580

207.75 0,2645

Konversi satuan dari viskositas yang diperoleh, dari satuan cp ke satuan


lb/ft.hr.
kg lb
0,001 2419,2 lb
m.s ft.hr
0,2580 cp × × kg = 0.624
1 cp 1 ft.hr
m.s

Taverage TavP (oF) Visositas 𝛍 (cp) Visositas 𝛍 (lb/ft.hr)


0,2580
210.99 0.624
0,2645
207.75 0.640

Pada perhitungan NRe pipa digunakan di dalam perhitungannya. Maka


satuan dari di perlu dikonversi dari m ke ft. Maka:
1 ft
0,005 m × = 0,0164 ft
0,3048 m

di ×Gp
Rep = μp
lb
0,0164 ft × 1941666.493
hr.ft2
Rep = lb
0.624
ft.hr

Rep = 51030.97834

di (ft) Gp (lb/hr.ft2) Visositas 𝛍 (lb/ft.hr) NRep


0.0164 1941666.493 0.624 51030.97834
0.0164 1879032.085 0.64 48150.19718

g. Menentukan Nilai h
Untuk memperoleh nilai ho maupun hi, dilakukan terlebih dahulu perhitungan
𝑙
terhadap , dan perlu dilakukan konversi terhadap satuan 𝑙 dan 𝑑𝑖 yaitu dari
𝑑𝑖

satuan m ke satuan ft.


1 ft
𝑙 = 1,0008 m × 0,3048 m = 3,283465 ft
1 ft
𝑑𝑖 = 0,005 m × 0,3048 m = 0,0164042 𝑓𝑡
𝒍 3,283465 ft
= = 200,162
𝒅𝒊 0,0164042 𝑓𝑡

1. Menentukan Nilai ho :
 Menentukan jH
Dari perhitungan diperoleh l/di yaitu 200,162. Maka dari NRe yang
diperoleh daei perhitungan dapat diperoleh pula jH dari grafik :

NRe jH
3800.85 12
6140.34 22

 Menentukan Nilai k
Nilai k ditentukan dari table “Thermal Conductivities of Liquids”
dengan data yang digunakan air. Maka diperoleh grafik sebagai
berikut :
Grafik Hubungan Antara T (°F) dan k
(Btu/(hr)(ft2)(°F/ft) y = 0.0005x + 0.3151
R² = 0.9999
0.450
0.400
0.350
0.300
0.250
k

0.200
0.150
0.100
0.050
0.000
0 50 100 150 200
T

Perhitungan data 1 untuk fluida dingin untuk mempeoleh k dengan

data dari Tav d 1 (132,96℉)


y = 0,0005x + 0,3151

y = 0,0005 (132,96℉) + 0,3151


y = 0,38158
y=k
k = 0,38158

Tav d (℉) k (Btu/(hr)(ft2)(℉/𝐟𝐭)


132.96 0,38158
129.54 0,37987

ho ×De Cp × μ −1/3 μ
jH = ×( ) × (μ )−0,14
k k w

jH ×k Cp × μ 1/3 μ
ho = De
×( k
) × (μ )0,14
w
Btu Btu lb
12 ×0,38158 1,003 × 1,295
(hr)(ft2 )(℉/ft)
ho = ×( lb ℉
Btu
ft hr
)1/3 × (1,0)0,14
0,6234 ft 0,38158
(hr)(ft2 )(℉/ft)

Btu Btu lb
12 ×0,38158 1,003 × 1,295
ho = hr ft ℉
×( lb ℉
Btu
ft hr
)1/3 × (1,0)0,14
0,6234 ft 0,38158
hr ft ℉

Btu
ho = 7,345 × 1,498 × 1
hr ft2 ℉

Btu
ho = 11,003 hr ft2 ℉

k
Cpd(
𝐁𝐓𝐔
) Viscositas
jH
(Btu/(hr)(ft2)(℉/ De (ft) 𝐥𝐛 𝐅 Btu
𝛍(lb/ft.hr) ho ( )
𝐟𝐭) hr ft2 ℉

12 0.38158 0.6234 1.003 1.295 11,003

22 0.37987 0.6235 1.005 1.336 5.163

2. Menentukan Nilai hi :
 Menentukan jH
Dari perhitungan diperoleh l/di yaitu 200,162. Maka dari NRe yang
diperoleh daei perhitungan dapat diperoleh pula jH dari grafik :
NRe jH
51030,97834 150
48150,19718 130

3. Menentukan Nilai k
Nilai k ditentukan dari table “Thermal Conductivities of Liquids”
dengan data yang digunakan air. Maka diperoleh grafik sebagai
berikut :

Grafik Hubungan Antara T (°F) dan k


(Btu/(hr)(ft2)(°F/ft) y = 0.0005x + 0.3151
R² = 0.9999
0.450
0.400
0.350
0.300
0.250
k

0.200
0.150
0.100
0.050
0.000
0 50 100 150 200
T
Perhitungan data 1 untuk fluida panas untuk mempeoleh k dengan

data dari Tav d 1 (210.99℉)


y = 0,0005x + 0,3151

y = 0,0005 (210.99℉) + 0,3151


y = 0,42059
y=k
k = 0,42059

Tav p (℉) k (Btu/(hr)(ft2)(℉/𝐟𝐭)


210.99 0,42059
207.75 0,41898

hi ×di Cp × μ −1/3 μ
jH = ×( ) × (μ )−0,14
k k w

jH ×k Cp × μ 1/3 μ
hi = ×( ) × (μ )0,14
di k w

Btu Btu lb
150 ×0,42059 1,009 × 0.624
(hr)(ft2 )(℉/ft)
ho = ×( lb ℉
Btu
ft hr
)1/3 × (1,0)0,14
0,0164004 ft 0,42059
(hr)(ft2 )(℉/ft)

Btu Btu lb
150 ×0,42059 1,009 × 0.624
ho = hr ft ℉
×( lb ℉
Btu
ft hr
)1/3 × (1,0)0,14
0,0164004 ft 0,42059
(hr)(ft2 )(℉/ft)

Btu
ho = 3846,77 × 1,1424 × 1
hr ft2 ℉

Btu
ho = 4394,58 hr ft2 ℉

k
𝐁𝐓𝐔 Viscositas
(Btu/(hr)(ft2)(℉/ Cpp( 𝐥𝐛 𝐅 )
jH di (ft) 𝛍(lb/ft.hr) Btu
𝐟𝐭) hi ( )
hr ft2 ℉

150 0,42059 1,009 0.624


0,0164004 4394,58

130 0,41898 1.010 0.640


0,0164004 5123,77

h. Menentukan Nilai hio


a. Untuk data I
𝐁𝐭𝐮 𝐁𝐭𝐮
ho(𝐡𝐫 𝐟𝐭 𝟐 ℉) hi(𝐡𝐫 𝐟𝐭 𝟐 ℉)

11,003 4394,58

5.163 5123,77

di
hio = hi × do

VII. PEMBAHASAN
VIII. KESIMPULAN
IX. DAFTAR PUSTAKA