3/2/2018 Robot Structural Analysis 2017 Help: Push Over Analysis Parameters

Help Home Sign In English

Enter a keyword

Push Over Analysis Parameters

Use this dialog to set up Pushover Analysis parameters for a dynamic case.

Access
1. Ensure that a modal analysis has already been defined.
2. Click Analysis Analysis Types New.
3. Select Push over in the Analysis Type dialog, and then click OK.

Case
The name of the load case.

Parameters
Node number - The number of a structure node belonging to the structure roof (see the figure
below).

http://help.autodesk.com/view/RSAPRO/2017/ENU/?guid=GUID-FA8128A6-3433-4605-B738-75672607437B 1/3
3/2/2018 Robot Structural Analysis 2017 Help: Push Over Analysis Parameters

Direction - Direction of an external factor affecting the structure in the global coordinate system.
Maximum displacement - Maximum displacement in the selected structure node.

Method of load definition


According to unit acceleration in the given direction - Determines a displacement vector during
the pushover analysis.
User-defined.

Note: The According to unit acceleration in the given direction option uses the following algorithm.

1. Calculation of the vector , where K, M - stiffness matrix and mass matrix,


respectively, Idir - unit direction vector; Φ dir - push mode vector.

2. Normalization: , where .
3. Definition of mass participation factor: Γ dir = (M Idir , F dir).
4. Definition of lateral forces as: Fdir = γdir M Φ dir , where γdir is a scalar multiplier.

The right-hand side of the equation system presented in point 1 can be defined with a static load case that
will make up a set of forces applied to the structure. The algorithm of calculation of lateral forces (points 2,
3, 4) is identical to that described above.

Geometric nonlinearity
P-Delta - Select this option to consider P-Delta effects during the analysis.
Large displacements - Select this option to take into account large displacements and/or rotations
during the analysis.
Nonlinear analysis parameters - Opens a dialog which allows you to set up the options of the
nonlinear analysis.

See also:
Pushover analysis description

http://help.autodesk.com/view/RSAPRO/2017/ENU/?guid=GUID-FA8128A6-3433-4605-B738-75672607437B 2/3
3/2/2018 Robot Structural Analysis 2017 Help: Push Over Analysis Parameters

Parent topic: Pushover Analysis Description

Was this helpful?


Yes No

Except where otherwise noted, this work is licensed under a Creative Commons Attribution-NonCommercial-
ShareAlike 3.0 Unported License. Please see the Autodesk Creative Commons FAQ for more information.
Privacy Legal Notices & Trademarks Report Noncompliance © 2018 Autodesk Inc. All rights reserved

http://help.autodesk.com/view/RSAPRO/2017/ENU/?guid=GUID-FA8128A6-3433-4605-B738-75672607437B 3/3

You might also like