0% found this document useful (0 votes)
64 views2 pages

Shaft Alignment Practice

This document provides guidelines for properly aligning shaft equipment, including pre-alignment check points such as ensuring coupling hub and shaft runout is within specifications and that there is no soft foot. It also lists recommendations for the alignment process, such as using stainless steel shims no more than 5 per support foot, with the shim stack not exceeding 12mm and one shim being at least 3mm thick, and notes about centifugal pumps and hold down bolts.

Uploaded by

kamal arab
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
64 views2 pages

Shaft Alignment Practice

This document provides guidelines for properly aligning shaft equipment, including pre-alignment check points such as ensuring coupling hub and shaft runout is within specifications and that there is no soft foot. It also lists recommendations for the alignment process, such as using stainless steel shims no more than 5 per support foot, with the shim stack not exceeding 12mm and one shim being at least 3mm thick, and notes about centifugal pumps and hold down bolts.

Uploaded by

kamal arab
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Shaft Alignment Practice

Pre-alignment check points


 Coupling hubs shall be installed according to the OEM specs.
 coupling hubs runout max =0.05 mm TIR
 coupling hub perpendicularity to the center of rotation max =0.05 mm TIR
 Soft foot with piping disconnected max =0.05 mm
 Shaft runout = 0.05 mm TIR
 Mechanical seal locking tabs disengaged
 DBSE should be as specified ±0.25 mm or less

Alignment recommended hints


The shim material should be stainless steel

Max number of shims under one support foot = 5 shims

The shim stack height shall not exceed 12 mm

One shim 3 mm thick or thicker shall be used

Shims numbers and total thickness should be recorded

Shims shall not extend outside the machine support foot edges.

Undercut hold down bolts are not permitted.

Hold down bolts shall not be bolt bound.

For centrifugal over hung pumps, the bearing bracket support shall be loosened during the
whole alignment process and pipe strain check