General description :
To preserve moisture HF transmission line (waveguide, coaxial ventilated, antennas etc ...)
supplied with high power transmitters (several kW), it is necessary to pressurize and to
dehydrate these lines in order to avoid the ionization of water molecules and avoid electric
arc phenomena that are likely to destroy the transmission line or even cause a fire.
Pneumatics characteristics
Model
Model
Descriptif At constant Values
All or nothing
pressure
Reduced by -40 °C for an ambient temperature of 20°C
and 95 % relative humidity
Dew point
All reference
temperature Dew point ambient point 19,5°C obtained dew point
19,5°-40°C = - 20,5°C
Pressure control Piezo resistive pressure sensor
SEL000174 SEL000113 Safety valve opening at 50 hPa
SEL000176 SEL000170 25 hPa for compressor flow
SEL000177 SEL000171
Protection
against over SEL000178 SEL000172 Safety valve opening at 160 hPa
pressure 40 hPa for compressor flow
SEL000175 SEL000112
SEL000180 SEL000181
Safety valve opening at 500 hPa
SEL000179 SEL000173
50 hPa for compressor flow
Drying medium Molecular sieve filter
Regeneration : Heating and sweeping with dry air
www.selecom.fr [email protected]
This document is the property of SELECOM sise Avenue du Pla de Dalt_ZA Alfred Sauvy_66500 PRADES. It may not be reproduced or communicated to third parties without written permission of
the Direction or the Quality Department
DAT/Pressu /010038F Page 1/2
Writer : V.Raoul Checker : A.Sabaca Approved: B.Deprez
According to model DAT1448B
DEHYDRATOR
PRESSURE CONSTANT
Technical characteristics
Model Model
Descriptif Values
All or nothing At constant pressure
SEL000177 SEL000171
SEL000175 SEL000112
SEL000179 SEL000173
230V 50/60Hz
Mains voltage SEL000178 SEL000172
SEL000174 SEL000113
SEL000180 SEL000181
SEL000176 SEL000170 115V 50/60Hz
Protection All reference Fuse type F 5x20 2 A
Filling All reference 20 W
Consumption Heating All reference 220 W
Filling and
All reference 230 W
heating
Switching alarm circuits 60V max 1 A
SEL000175 SEL000112 300l/h max ( at the
SEL000174 SEL000113 specified pressure *)
260 l/h max ( at the
Air flow SEL000177 SEL000171
specified pressure *)
SEL000178 SEL000172 280 l/h max ( at the
SEL000176 SEL000170 specified pressure *)
SEL000175 SEL000112
SEL000178 SEL000172
10 hPa 3 hPa
Alarm pressure SEL000174 SEL000113
SEL000176 SEL000170
SEL000177 SEL000171 15 hPa 5 hPa
SEL000175 SEL000112
SEL000174 SEL000113
20 hPa 5 hPa
SEL000176 SEL000170
Low pressure SEL000718 SEL000172
SEL000177 SEL000171 40 hPa 5 hPa
SEL000179 SEL000173 200 hPa 20 hPa
SEL000175 SEL000112
40 hPa 3 hPa
SEL000174 SEL000113
SEL000176 SEL000170
High pressure 60 hPa 5 hPa
SEL000178 SEL000172
SEL000177 SEL000171 80 hPa 5 hPa
SEL000179 SEL000173 300 hPa 30 hPa
Filter filter
Pressure valve
Solenoid valve
Alarms LED X3
Compressor
Navigation button
Ethernet port
et
LCD display
DAT/Pressu/010038G Page 2/3
DEHYDRATOR
PRESSURE CONSTANT
Interface
Backlit LCD 2 lines - 16 characters
Display Hour meter / Pressure / alarms / Access to configuration menus
On / off function
Humidity level
Ethernet port 1
WEB interface
Monitoring
SNMP V2 agent*
Dry loops (x3) NC or NO
Alarms
(Default Pressure / Heating / Humidity)
Environment
Storage -20°C/+70°C
Operation specs guaranteed -0°C/+40°C
Operation specs without
.-10°C/+50°C
guaranteed
Max humidity 95% RH to 20°C
Dry air output Fluted tip for hose Ø 8 mm
MTBF 5 000 h
* Coming soon
Mechanical characteristics
L483 mm
H132.5 mm
P230 mm
Rack 3U
Weight : 5 Kg