This document provides specifications for a constant pressure dehydrator. The dehydrator removes moisture from transmission lines to prevent arc phenomena. It maintains a constant reduced dew point of -20.5°C using a molecular sieve filter and regenerates through heating and dry air sweeping. Key specifications include 230V power, air flows up to 300L/h depending on model, and low pressure alarms from 10-40hPa.

Uploaded by

hang le
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
178 views3 pages

Dat Pressu GB

This document provides specifications for a constant pressure dehydrator. The dehydrator removes moisture from transmission lines to prevent arc phenomena. It maintains a constant reduced dew point of -20.5°C using a molecular sieve filter and regenerates through heating and dry air sweeping. Key specifications include 230V power, air flows up to 300L/h depending on model, and low pressure alarms from 10-40hPa.

Uploaded by

hang le
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Pages : 02

DATASHEET Reference : 010038G


DEHYDRATOR Date of application :
25/07/2017
CONSTANT PRESSURE

 General description :

To preserve moisture HF transmission line (waveguide, coaxial ventilated, antennas etc ...)
supplied with high power transmitters (several kW), it is necessary to pressurize and to
dehydrate these lines in order to avoid the ionization of water molecules and avoid electric
arc phenomena that are likely to destroy the transmission line or even cause a fire.

Pneumatics characteristics
Model
Model
Descriptif At constant Values
All or nothing
pressure
Reduced by -40 °C for an ambient temperature of 20°C
and 95 % relative humidity
Dew point
All reference
temperature Dew point ambient point 19,5°C obtained dew point
19,5°-40°C = - 20,5°C

Pressure control Piezo resistive pressure sensor

SEL000174 SEL000113 Safety valve opening at 50 hPa


SEL000176 SEL000170 25 hPa for compressor flow

SEL000177 SEL000171
Protection
against over SEL000178 SEL000172 Safety valve opening at 160 hPa
pressure  40 hPa for compressor flow
SEL000175 SEL000112
SEL000180 SEL000181
Safety valve opening at 500 hPa
SEL000179 SEL000173
 50 hPa for compressor flow
Drying medium Molecular sieve filter

Regeneration : Heating and sweeping with dry air

www.selecom.fr [email protected]
This document is the property of SELECOM sise Avenue du Pla de Dalt_ZA Alfred Sauvy_66500 PRADES. It may not be reproduced or communicated to third parties without written permission of
the Direction or the Quality Department
DAT/Pressu /010038F Page 1/2
Writer : V.Raoul Checker : A.Sabaca Approved: B.Deprez
According to model DAT1448B
DEHYDRATOR
PRESSURE CONSTANT

Technical characteristics

Model Model
Descriptif Values
All or nothing At constant pressure
SEL000177 SEL000171
SEL000175 SEL000112
SEL000179 SEL000173
230V 50/60Hz
Mains voltage SEL000178 SEL000172
SEL000174 SEL000113
SEL000180 SEL000181
SEL000176 SEL000170 115V 50/60Hz
Protection All reference Fuse type F 5x20 2 A

Filling All reference 20 W

Consumption Heating All reference 220 W


Filling and
All reference 230 W
heating
Switching alarm circuits 60V max 1 A
SEL000175 SEL000112 300l/h max ( at the
SEL000174 SEL000113 specified pressure *)
260 l/h max ( at the
Air flow SEL000177 SEL000171
specified pressure *)
SEL000178 SEL000172 280 l/h max ( at the
SEL000176 SEL000170 specified pressure *)
SEL000175 SEL000112
SEL000178 SEL000172
10 hPa  3 hPa
Alarm pressure SEL000174 SEL000113
SEL000176 SEL000170
SEL000177 SEL000171 15 hPa  5 hPa
SEL000175 SEL000112
SEL000174 SEL000113
20 hPa  5 hPa
SEL000176 SEL000170
Low pressure SEL000718 SEL000172
SEL000177 SEL000171 40 hPa  5 hPa
SEL000179 SEL000173 200 hPa  20 hPa
SEL000175 SEL000112
40 hPa  3 hPa
SEL000174 SEL000113
SEL000176 SEL000170
High pressure 60 hPa  5 hPa
SEL000178 SEL000172
SEL000177 SEL000171 80 hPa  5 hPa
SEL000179 SEL000173 300 hPa  30 hPa

Filter filter

Pressure valve

Solenoid valve
Alarms LED X3
Compressor

Navigation button

Ethernet port

et
LCD display

DAT/Pressu/010038G Page 2/3


DEHYDRATOR
PRESSURE CONSTANT

Interface
Backlit LCD 2 lines - 16 characters
Display Hour meter / Pressure / alarms / Access to configuration menus
On / off function
Humidity level
Ethernet port 1
WEB interface
Monitoring
SNMP V2 agent*
Dry loops (x3) NC or NO
Alarms
(Default Pressure / Heating / Humidity)
Environment
Storage -20°C/+70°C

Operation specs guaranteed -0°C/+40°C

Operation specs without


.-10°C/+50°C
guaranteed

Max humidity 95% RH to 20°C

Dry air output Fluted tip for hose Ø 8 mm

MTBF 5 000 h
* Coming soon

Mechanical characteristics

L483 mm
H132.5 mm
P230 mm

Rack 3U

Weight : 5 Kg

DAT/Pressu/010038G Page 3/3