VIL LIMITED
(Formerly VIJAI INFRASTRUCTURE LIMITED)
An ISO 9001: 2008 Certified Infrastructure Company
DETERMINATION OF THE PARTICLE SIZE DISTRIBUTION ( AGGREGATES)
ASTM C 136 / EN 933-1 / BS 812-103.1
Laboratory VIL - KAMBI YA MWANZA
Project KAKAMEGA - KABURENGU (WEBUYE) ROAD
Sample CODE Type of aggregate Testing method Sampling date
0/40 ALL IN AGGREGATES
Sampling site/Source Samp. n. Coordinates Sam. received
Project specification: Sieves series standard Collected by
Dry weight of sample (g) Dry weight of washed sample (g) Max. Nominal size - mm Date testing
1200.0 g g
ASTM n. Sieve size Retained Cumulative Passing Requirements
mm g % g % % % %
50 0.0% 0.0% 100.0% 100.0%
37.5 36.0 3.0% 36 3.0% 97.0% 95.0% 100.0%
28.0 0.0 0.0% 36 3.0% 97.0%
20.0 350.0 29.2% 386 32.2% 67.8% 45.0% 80.0%
14.0 0.0 0.0% 386 32.2% 67.8%
10.0 0.0 0.0% 386 32.2% 67.8%
5.0 450.0 37.5% 836 69.7% 30.3% 25.0% 50.0%
4.0 0.0 0.0% 836 69.7% 30.3%
2.4 0.0 0.0% 836 69.7% 30.3%
1.180 0.0 0.0% 836 69.7% 30.3%
0.600 260.0 21.7% 1096 91.3% 8.7% 8.0% 30.0%
0.300 0.0 0.0% 1096 91.3% 8.7%
0.150 104.0 8.7% 1200 100.0% 0.0% 0.0% 8.0%
10090 75 63 50 37.5 28 25 20 14 10 6.3 5.0 2.0 1.0 0.600 0.425 0.300 0.150 0.075 BS - mm
100.0%
90.0%
80.0%
70.0%
60.0%
50.0%
40.0%
30.0%
20.0%
10.0%
0.0%
2 1/2" 1 1/4" 5/8" 5/16" 1/4" N. 5 N. 10 N. 18 N. 60 N. 120 N. 200 ASTM - in
Remarks
TESTED BY VIL CONSTRUCTION COMPANY HOWARD HUMPHREYS
The Senior Technician The Material Engineer The Technician The Material Engineer