Road Project Aggregate Analysis

VIL Limited conducted a particle size distribution test (aggregates) according to ASTM C 136 on samples from the Kakamega-Kaburengu Road project in Kambi Ya Mwanza, Kenya. The test analyzed a 1200g sample of 0/40 all-in aggregates to determine the percentage passing and retained on each sieve. The results showed that 8.7% of the sample passed through a 0.150mm sieve and met the specification requirements.

Uploaded by

Isaiahogeda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
240 views1 page

Road Project Aggregate Analysis

VIL Limited conducted a particle size distribution test (aggregates) according to ASTM C 136 on samples from the Kakamega-Kaburengu Road project in Kambi Ya Mwanza, Kenya. The test analyzed a 1200g sample of 0/40 all-in aggregates to determine the percentage passing and retained on each sieve. The results showed that 8.7% of the sample passed through a 0.150mm sieve and met the specification requirements.

Uploaded by

Isaiahogeda
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

VIL LIMITED

(Formerly VIJAI INFRASTRUCTURE LIMITED)


An ISO 9001: 2008 Certified Infrastructure Company

DETERMINATION OF THE PARTICLE SIZE DISTRIBUTION ( AGGREGATES)


ASTM C 136 / EN 933-1 / BS 812-103.1
Laboratory VIL - KAMBI YA MWANZA
Project KAKAMEGA - KABURENGU (WEBUYE) ROAD

Sample CODE Type of aggregate Testing method Sampling date


0/40 ALL IN AGGREGATES
Sampling site/Source Samp. n. Coordinates Sam. received

Project specification: Sieves series standard Collected by

Dry weight of sample (g) Dry weight of washed sample (g) Max. Nominal size - mm Date testing
1200.0 g g

ASTM n. Sieve size Retained Cumulative Passing Requirements


mm g % g % % % %

50 0.0% 0.0% 100.0% 100.0%


37.5 36.0 3.0% 36 3.0% 97.0% 95.0% 100.0%
28.0 0.0 0.0% 36 3.0% 97.0%
20.0 350.0 29.2% 386 32.2% 67.8% 45.0% 80.0%
14.0 0.0 0.0% 386 32.2% 67.8%
10.0 0.0 0.0% 386 32.2% 67.8%
5.0 450.0 37.5% 836 69.7% 30.3% 25.0% 50.0%
4.0 0.0 0.0% 836 69.7% 30.3%
2.4 0.0 0.0% 836 69.7% 30.3%
1.180 0.0 0.0% 836 69.7% 30.3%
0.600 260.0 21.7% 1096 91.3% 8.7% 8.0% 30.0%
0.300 0.0 0.0% 1096 91.3% 8.7%
0.150 104.0 8.7% 1200 100.0% 0.0% 0.0% 8.0%

10090 75 63 50 37.5 28 25 20 14 10 6.3 5.0 2.0 1.0 0.600 0.425 0.300 0.150 0.075 BS - mm
100.0%

90.0%

80.0%

70.0%

60.0%

50.0%

40.0%

30.0%

20.0%

10.0%

0.0%
2 1/2" 1 1/4" 5/8" 5/16" 1/4" N. 5 N. 10 N. 18 N. 60 N. 120 N. 200 ASTM - in

Remarks

TESTED BY VIL CONSTRUCTION COMPANY HOWARD HUMPHREYS


The Senior Technician The Material Engineer The Technician The Material Engineer