This document contains hydraulic design calculations for optimizing intake flow at a flood control facility. It includes parameters like flood discharge, weir dimensions, intake opening specifications, gate details, and spillway characteristics. Calculations are shown for determining the head and water level required for the desired discharge capacity from the intake and spillway. The analysis finds that a water level of 1158.62 meters at the river would provide the targeted 4.88 cubic meters per second flow from the intake orifice.

Uploaded by

Pujan Neupane
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
166 views3 pages

Spillway Flow Optimization

This document contains hydraulic design calculations for optimizing intake flow at a flood control facility. It includes parameters like flood discharge, weir dimensions, intake opening specifications, gate details, and spillway characteristics. Calculations are shown for determining the head and water level required for the desired discharge capacity from the intake and spillway. The analysis finds that a water level of 1158.62 meters at the river would provide the targeted 4.88 cubic meters per second flow from the intake orifice.

Uploaded by

Pujan Neupane
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Hydraulic Design

Intake flow optimization at operational flood condition

Description Value Unit


Flood discharge at 20 years 126.00 m3/s
Width of the weir 12.00 m
Weir crest level 1157.50 amsl

Flood level in River HFL 1160.74 amsl

Design discharge Q 1.87 m3/s


Intake parameters
Number of opening n 1.00
Width of opening b 3.20 m
Depth of opening d 0.80 m
Coefficient of orifice Co 0.65

Gate parameters
Width of gate b 2.00 m
Depth of gate d 2.00 m

Spillway parameters
Coefficient of weir Cd 1.70
Crest width l 5.00 m
Spillway crest level 1157.50 amsl

Flow Optmization
Head over crest for spillway hs 0.50 m
Discharge capacity of spillway Qs 3.01 m3/s
Water level at spillway SWL 1158.00 amsl

Flow from intake Qg 4.88 m3/s


Head required hg 0.18 m
Water level inside intake canal 1158.18 amsl

Flow from intake orifice Qg 4.88 m3/s


Head required for orifice hg 0.44 m
Water level at river 1158.62 amsl

Provided width of the spillway L 5m


condition

Remark

20 years flood level

Finished concrete surface

Side weir
For iteration

Total flow from gate

OK
Q D v
11.36 2.3 2.734216
10.8 2.2 2.841113
9.5 2 3.023944
11.36 2 3.616