0% found this document useful (0 votes)
85 views6 pages

Goals For Today: 2.004 Fall '07

The document discusses operational amplifiers and their input-output relationships. It then covers more about zeros, specifically zeros in the right-half plane resulting in non-minimum phase responses. Finally, it previews the topics for the next week which are block diagram operations and analysis of a simple feedback system.

Uploaded by

Lemdy Anwuna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
85 views6 pages

Goals For Today: 2.004 Fall '07

The document discusses operational amplifiers and their input-output relationships. It then covers more about zeros, specifically zeros in the right-half plane resulting in non-minimum phase responses. Finally, it previews the topics for the next week which are block diagram operations and analysis of a simple feedback system.

Uploaded by

Lemdy Anwuna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Goals for today

• The operational amplifier


– input-output relationships
– feedback configuration
• More about zeros
– zero on the right-half plane: non-minimum phase response
– Zero-pole cancellation
• Next week
– Block diagram operations
– Analysis of a simple feedback system

2.004 Fall ’07 Lecture 10 – Friday, Sept. 28


The operational amplifier (op-amp)
(a) Generally, vo = A (v2 − v1 ),
where A is the amplifier gain.
(b) When v2 is grounded, as is often
+V the case in practice, then vo = −Av1 .
+v1(t) v1(t) (Inverting amplifier.)
- vo(t) - vo(t)
+v2(t) A A (c) Often, A is large enough that
+ + we can approximate A → ∞.
Rather than connecting the input directly,
-V
the op—amp should then instead be used in the
feedback configuration of Fig. (c).
We have:
Z2(s)
V1 = 0; Ia = 0
Z1(s) I2(s) (because Vo must remain finite) therefore
Vi(s) V1(s)
- Vo(s)
Ia(s) I1 + I2 = 0;
I1(s) +
V i − V 1 = V i = I 1 Z1 ;
Vo − V1 = Vo = I2 Z2 .
Combining, we obtain
Figure by MIT OpenCourseWare.
Figure 2.10 Vo (s) Z2 (s)
(see also Lecture 04 – page 16) =− .
Vi (s) Z1 (s)

2.004 Fall ’07 Lecture 10 – Friday, Sept. 28


Example: PID controller
R2 = 220 kΩ C2 = 0.1 µF Z2(s)
C1 = 5.6 µF
Z1(s) I2(s)
vi(t) v1(t) Vi(s) V1(s)
- -
vo(t) vo(s)
Ia(s)
R1 = 360 kΩ + I1(s) +

Figure by MIT OpenCourseWare. Figure 2.11 Figure 2.10

Equivalent impedances: ⇒ Transfer Function:

(R1 , C1 connected in parallel) Vo (s) s2 + 45.95s + 22.55


= −1.232 .
Vi (s) s
1 1 R1 360 × 103
= + C1 s ⇒ Z1 (s) = = ;
Z1 (s) R1 1 + R1 C1 s 1 + 2.016s

(R2 , C2 connected in series)


1 1
Z2 (s) = R2 + = 220 × 103 + −7 .
C2 s 10 s

2.004 Fall ’07 Lecture 10 – Friday, Sept. 28


Example: all-pass filter Step response without zero:

1 1/10 1/10
Co (s) = − =− +
s (s + 10) s s + 10
R1 1 ¡ ¢
c0 (t) = − 1 − e−10t u(t).
10
R2
V1(s)
- Vo(s) Images removed due to copyright restrictions.
I(s) Please see Fig. 4.28 in Nise, Norman S. Control Systems Engineering.
Vi(s) 4th ed. Hoboken, NJ: John Wiley, 2004.
+
R3 V2(s)

Figure by MIT OpenCourseWare.


Transfer function: jω Step response:
R2 s − 10
s− σ C(s) = −
Vo (s) R1 R1 R3 C s (s + 10)
=− . −10 +10 1 2
Vi (s) R2 1
s+ = − ⇒
R3 C s s + 10
¡ ¢
c(t) = 1 − 2e−10t u(t).
Substituting R1 = R2 , R3 = 100kΩ, C = 1μF,
Non—minimum phase system
Vo (s) s − 10
=− zero in the r.h.p.
Vi (s) s + 10

2.004 Fall ’07 Lecture 10 – Friday, Sept. 28


Nonminimum-phase response
Consider a system without a zero, whose step response is Co (s)
and recall that the effect of the zero is C(s) = (s + a)Co (s) = sCo (s) + aCo (s).
In the time domain, c(t) = ċo (t) + aco (t). Therefore,
the system response with the zero is the sum of the derivative of the
original response plus the original response amplified by a gain equal to a
(”proportional term.”)

If a < 0 and the derivative term ċo (t = 0) is larger than the


proportional term aco (t = 0), then the response will initially follow
the derivative term in the opposite direction of the proportional term.

Images removed due to copyright restrictions.

Please see: Fig. 4.26 in Nise, Norman S. Control Systems Engineering. 4th ed. Hoboken, NJ: John Wiley, 2004.

2.004 Fall ’07 Lecture 10 – Friday, Sept. 28


Zero-pole cancellation
Compare the step responses

26.25(s + 4)
C1 (s) =
s(s + 3.5)(s + 5)(s + 6)
26.25(s + 4)
C2 (s) = .
s(s + 4.01)(s + 5)(s + 6)
non-negligible
Partial fraction expansion yields
negligible
1 3.5 3.5 1
C1 (s) = − + −
s s + 5 s + 6 s + 3.5
0.87 5.3 4.4 0.033
C2 (s) = − + − .
s s + 5 s + 6 s + 4.01

C1 (s) jω C2 (s) jω
−4 σ −4 σ
−6 −5 −3.5 input −6 −5 −4.01 input
pole pole

zero-pole cancellation does not occur zero-pole cancellation occurs

2.004 Fall ’07 Lecture 10 – Friday, Sept. 28