Tubular MMO Anodes for Cathodic Protection

This document provides specifications for mixed metal oxide tubular anodes used in cathodic protection applications. The anodes have a titanium substrate coated with iridium oxide and tantalum oxide using a thermal decomposition technique. They are 25.4mm in diameter, 0.9mm thick and available in lengths from 500mm to 1000mm. The anodes are suitable for use in soils, mud, fresh water, brackish water and seawater. Current outputs vary depending on environmental conditions but the anodes are designed to operate for 20 years. Standard anode types and dimensions are shown along with their typical current outputs at different temperatures.

Uploaded by

Soltani Ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
201 views2 pages

Tubular MMO Anodes for Cathodic Protection

This document provides specifications for mixed metal oxide tubular anodes used in cathodic protection applications. The anodes have a titanium substrate coated with iridium oxide and tantalum oxide using a thermal decomposition technique. They are 25.4mm in diameter, 0.9mm thick and available in lengths from 500mm to 1000mm. The anodes are suitable for use in soils, mud, fresh water, brackish water and seawater. Current outputs vary depending on environmental conditions but the anodes are designed to operate for 20 years. Standard anode types and dimensions are shown along with their typical current outputs at different temperatures.

Uploaded by

Soltani Ali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

IMPRESSED CURRENT CATHODIC PROTECTION DATASHEET 2.2.

MIXED METAL OXIDE


TUBULAR ANODES
REVISION 1

APPLICATION
Marine Structures, Seawater Intakes, Deepwell Groundbeds, Horizontal Groundbeds, Distributed Anodes, Tank Internals
& Tank Bottoms Suitable For Use In Soils, Mud, Carbonaceous & Pet Coke Backfill; Fresh, Brackish and Sea Water

TUBULAR MMO ANODE DATA

Substrate Titanium ASTM B338 Grade 1 or 2

Coating IrO2/Ta2O5

Coating Method Multi pass thermal decomposition of precious metal salts technique

Diameter 25.4mm

Wall Thickness 0.90mm

Consumption Rate 0.5 - 4.0 mg/A/yr depending upon CP application conditions

Utilisation Factor Dimensionally Stable

Working Environment Suitable for Cl2 & O2 or combination of both

Operating Characteristics Environment Max Current Density Life


(A/m2) (Years)
Carbonaceous Backfill 50 20
Calcined Petroleum Coke 100 20
Freshwater 100 20
Brackish Water 100-300 20
Seawater 600 20

Coating loading can be adjusted for specific lifetime/current density requirement

Cable Types HMWPE/PVDF(Kynar); XLPE/PVC/SWA/PVC; EPR/CSPE

Maximum 1Cx50mm2

Anode/Cable Connection Centre connection less than 0.001 Ohm, resin encapsulated & helium tested
to prove effective seal

Venture Way, Grantham, Lincs NG31 7XS UK. Tel: +44 (0)1476 590666 Fax: +44 (0)1476 570605 DATASHEET
Email: [email protected] Website: www.cathodic.co.uk 2.2.1
Registered Office: Minalloy House, Regent Street, Sheffield S1 3NJ, UK VAT No. 116 8408 71, Reg’d in England No. 478098
IMPRESSED CURRENT CATHODIC PROTECTION DATASHEET 2.2.1

MIXED METAL OXIDE


TUBULAR ANODES
REVISION 1

STANDARD ANODE TYPES, DIMENSIONS AND OUTPUTS

Current Output Current Output


Type OD Length
(Typical) (Typical)
Soil (with carbon backfill) mm inches mm inches (Amps from 5-70˚C) (Amps from 0-5˚C)
S-2.5/50 25 1 500 19.7 4 2
S-2.5/100 25 1 1000 39.4 8 4
Fresh Water
FW-2.5/50 25 1 500 19.7 4 2
FW-2.5/100 25 1 1000 39.4 8 4
Sea Water
SW-2.5/50 25 1 500 19.7 25 5
SW-2.5/100 25 1 1000 39.4 50 10
Mud (*)
M-2.5/50 25 1 500 19.7 2-4 1.5
M-2.5/100 25 1 1000 39.4 4-8 3
Brackish Water (**) (Amps from 10-70˚C) (Amps from 0-10˚C)
BW-2.5/50 25 1 500 19.7 4÷12 2÷6
BW-2.5/100 25 1 1000 39.4 8÷24 4÷12

(*) Current outputs in mud depend on site conditions (sea mud or river mud, etc)
(**) Current outputs in brackish water depend on site conditions & chloride concentrations.

NOTES
• Coating loading may be adjusted to suit a particular current density or design life

• Standard anodes are designed for 20 year life, however, design life of up to 50 years can be catered for.

• Tubular MMO anode strings can be supplied to Clients specific requirements.

• Other tube diameters are available on request,16mm dia & 32mm dia.

DATASHEET Venture Way, Grantham, Lincs NG31 7XS UK. Tel: +44 (0)1476 590666 Fax: +44 (0)1476 570605
2.2.1 Email: [email protected] Website: www.cathodic.co.uk
Registered Office: Minalloy House, Regent Street, Sheffield S1 3NJ, UK VAT No. 116 8408 71, Reg’d in England No. 478098