The document specifies the inputs, cycle times, and other details for a VPA filter system for a copper concentrate application in Ecuador. The system will process 37.4 dry metric tons per hour of material that is 60% solids with a particle size of 23 micrometers or smaller. The operating cycle for filtration is 3.05 minutes with an additional 0.5 minutes for compression and 2.3 minutes for air blow. One VPA 1540-40 filter will be used with a total volume of 2,720 liters and 40 chambers at 40mm depth.

Uploaded by

1394203031
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
86 views1 page

Ruta de Cobre Cu VPA Process Specification

The document specifies the inputs, cycle times, and other details for a VPA filter system for a copper concentrate application in Ecuador. The system will process 37.4 dry metric tons per hour of material that is 60% solids with a particle size of 23 micrometers or smaller. The operating cycle for filtration is 3.05 minutes with an additional 0.5 minutes for compression and 2.3 minutes for air blow. One VPA 1540-40 filter will be used with a total volume of 2,720 liters and 40 chambers at 40mm depth.

Uploaded by

1394203031
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

VPA FILTER

Process Specification

Customer: Compañia Minera Ruta de Cobre Project: 0


Application: Cu Concentrate Country: Ecuador
Proposal No.: SAL-519925 Date: September 25, 2018
Based on: Estimate Revision: 0

INPUTS
Solids density: 4,10 t/m³
Liquid density: 1,00 t/m³
Capacity DMTPH, total: 37,4 (dry metric ton per hour)
Capacity DMTPH, per filter: 37,35
Feed solids, w/w: 60,0 %
Pulp density: 1,83 t/m³
Cake moisture: 9,0 %
80% passing product size: 23 µm
% passing product size: 0 µm
% passing product size: 0 µm
% passing product size: 0 µm

CYCLE TIME
Operating cycle;
filtration: 3,05 min 183 sec
compression: 0,50 min 30 sec
washing: 0,00 min 0 sec
air blow: 2,30 min 138 sec
technical time: 3,90 min 234 sec
Total cycle time: 9,75 min 585 sec

SLURRY FEED
Slurry feed pressure (at VPA filter): 0,0 bar

COMPRESSED AIR
Membrane pressure (at VPA filter): 0,0 bar 0 psi
Air blow pressure (at VPA filter): 0,0 bar 0 psi
Air flow at end of air blow: 0,3 Nm³/m²,min 1,0 ft³/ft²,min
Air blow area, per filter: 68,0 m² 732 ft²
Required air capacity at end of air blow, per filter: 20,4 Nm³/min 720 ft3/min

OTHER INFORMATION
Slurry volume / cycle / filter: 5,9 m³ 1556 gallon (US)
Dry Solids / cycle / filter: 6,5 ton 7,1 short ton
Wet Cake / cycle / filter: 7,1 ton 7,8 short ton
Filtration rate (double area basis): 292,7 kg/m²,h 59,9 lb/ ft².h
Filtration rate (single area basis): 585,4 kg/m²,h 119,9 lb/ ft².h
Instantaneous Capacity DMTPH per filter 40 ton 43,9 short ton
Instantaneous Capacity DMTPH, total 40 ton 43,9 short ton

EQUIPMENT SELECTION
Total volume, per filter: 2 720 liters 718,5 gallon (US)
VPA filter size: 15
Chamber depth: 40 mm 1,57 inch
Chambers, per filter: 40
Selected VPA Filter size: VPA 1540-40
VPA filters in operation: 1
VPA filters in standby: 0