Consolidated Drained - Triaxial Test: Consolidation Results

This document summarizes the results of a consolidated drained triaxial test on a soil sample from a depth of 5.00-5.50 meters at the Matarbari Ultra Super Critical Coal-Fired Power Project site in Matarbari, Bangladesh. The test was conducted according to ASTM D 2850-70 and involved measuring the volume change, consolidation properties, stress-strain behavior, and Mohr-Coulomb failure envelope of two soil specimens under varying confining pressures. Key results included the time for 90% consolidation, coefficient of consolidation, deviator stress values, axial stresses, cohesion, angle of shear, and major and minor principal stresses.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
69 views1 page

Consolidated Drained - Triaxial Test: Consolidation Results

This document summarizes the results of a consolidated drained triaxial test on a soil sample from a depth of 5.00-5.50 meters at the Matarbari Ultra Super Critical Coal-Fired Power Project site in Matarbari, Bangladesh. The test was conducted according to ASTM D 2850-70 and involved measuring the volume change, consolidation properties, stress-strain behavior, and Mohr-Coulomb failure envelope of two soil specimens under varying confining pressures. Key results included the time for 90% consolidation, coefficient of consolidation, deviator stress values, axial stresses, cohesion, angle of shear, and major and minor principal stresses.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CONSOLIDATED DRAINED - TRIAXIAL TEST

PROJECT : MATARBARI ULTRA SUPER CRITICAL COAL-FIRED POWER


LOCATION : MATARBARI BH ID : NBH-05
SAMPLE NUMBER : UDS-01 SAMPLE DEPTH : 5.00-5.50 m
TESTING METHOD : ASTM D 2850 - 70

CONSOLIDATION RESULTS
SPECIMEN I SPECIMEN II
Square - root Time (min) Square - root Time (min)
0 5 10 15 20 25 30 35 40 0 5 10 15 20 25 30 35 40
0 0

1 1
Volume Change (cm³)

Volume Change (cm³)


2 2

3 3

4 4

5 5

6 6

Time for 90% Consolidation min 9.000 Time for 90% Consolidation min 6.250
Coeff.of Consolidation cm²/min 0.7472 Coeff.of Consolidation cm²/min 0.9918

STRESS-STRAIN GRAPH
SPECIMEN I SPECIMEN II

1.4
1.5
1.3
1.4
1.2
1.3
Deviator Stress (Kg/cm²)

1.1 1.2
Deviator Stress (Kg/cm²)

1 1.1
0.9 1
0.8 0.9
0.7 0.8

0.6 0.7
0.6
0.5
0.5
0.4
0.4
0.3
0.3
0.2
0.2
0.1 0.1
0 0
0 1 2 3 4 0 1 2 3 4 5 6
Axial Strain (%) Axial Strain (%)
Cell Pressure (Kg/cm²) 1.000 Cell Pressure (Kg/cm²) 2.000
Deviator Stress (Kg/cm²) 1.136 Deviator Stress (Kg/cm²) 1.385
Axial Stress 2.136 Axial Stress 3.385

MOHR-COULOMB FAILURE ENVELOPE

2
SHEAR STRESS (KG/CM )
2

0
0 1 2 2 3 4
NORMAL STRESS (KG/CM )

Cohesion Kg/cm² 0.3940


Angle of Shear ˚ 6.3660
Minor Principal Stress Kg/cm² 1.000 2.000
Major Principal Stress Kg/cm² 2.015 3.377