0% found this document useful (0 votes)
387 views2 pages

Magnetic Flow Meter Data Sheet

The document describes a flow transmitter system with an electromagnetic flow element and digital indicator. The system is intended to measure water flow between 0-500 cubic meters per hour at pressures up to 16 bar. It uses an electromagnetic flow sensor inserted into a stainless steel pipe with flanges. The sensor outputs a 4-20 mA signal to a microprocessor-based converter with a graphic display indicating flow rate and total. All necessary piping and electrical components for installation are included.

Uploaded by

Ellen Sheng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
387 views2 pages

Magnetic Flow Meter Data Sheet

The document describes a flow transmitter system with an electromagnetic flow element and digital indicator. The system is intended to measure water flow between 0-500 cubic meters per hour at pressures up to 16 bar. It uses an electromagnetic flow sensor inserted into a stainless steel pipe with flanges. The sensor outputs a 4-20 mA signal to a microprocessor-based converter with a graphic display indicating flow rate and total. All necessary piping and electrical components for installation are included.

Uploaded by

Ellen Sheng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

FLOW TRANSMITTER WITH FLOW ELEMENT AND DIGITAL INDICATOR

The Flow Transmitter shall be preferably electromagnetic type and shall be


supplied with Flow element and facility for fitment of Flow Indicator at local
and remote location. These Flow Transmitters shall meet the following
requirements in general:

Temperature range : 0-70°C


Type of sensing element : Electromagnetic flow sensor with
microprocessor based signal converter
Type : Insertion with solid state transmitter
Enclosure type : Nema 4X
Protection : IP67
Input : 24VDC/220VAC 50 Hz
Output : 4-20 mA, 2 wire, HART
Flow rate of Water : 0-500 m3/hr
Pressure of water : 0-16 bar(working)–Max press 25 bar
Casing material : Stainless Steel
Accuracy : ± 0.5% of full scale
Material of Seals : Teflon
Other internal Parts : SS 304 / 316
Electrodes : SS 316
Socket connection size : ½” NTP with half coupling to
connection
Connection Size/Type : 200 NB, Flanged as per ASA / ANSI

Connecting details of Flow Element with water pipes are to be provided. All the
piping, flanges, unions, half couplings, valves and electrical components etc.
required for installation of Flow Element and Transmitter shall be there.
Details of Electromagnetic Flow Sensor:

Flow Tube : SS304


Coil Housing : Fully welded, SS316 for meter
Electrodes : SS316 / SS316L & self cleaning type
Process connection : Flanged to ANSI 300#
Flanges : CS

Details of Electromagnetic Signal Converter:

Type : Microprocessor based


Bright graphic display : Large backlight with 2 line graphic
LC display parameters : Actual flow rate and totalizer
Housing : Die cast aluminium