This document provides specifications for an orifice plate flowmeter with flange taps used to measure natural gas flow. Key details include that it has a 1.00345 inch orifice diameter, operates at pressures up to 1600 psig, and is designed to measure flow rates from 1700000 to 4000000 standard cubic feet per day of natural gas at 68 degrees Fahrenheit. The orifice plate element and flanges are made of carbon steel and meet AGA 3 standards.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
145 views1 page
Fe-1001 W-H
This document provides specifications for an orifice plate flowmeter with flange taps used to measure natural gas flow. Key details include that it has a 1.00345 inch orifice diameter, operates at pressures up to 1600 psig, and is designed to measure flow rates from 1700000 to 4000000 standard cubic feet per day of natural gas at 68 degrees Fahrenheit. The orifice plate element and flanges are made of carbon steel and meet AGA 3 standards.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
Pgas-PTG Kso
AGA Orifice Plate - Concentric - Flange Taps - Gas Flow
Spec. Sheet MKI Project 4600002525Rev. WELL CONNECTION TN-G68r Req. Date By Appr.
Tag Number FE - 1001
Element 1) Design type Concentric data 2) Design standard AGA 3 3) Element material Carbon steel 4) Ring joint data 5) Manufacturer DANIEL 6) Model 7) Beta ratio (d/D) .318354 8) Orifice diameter 1.00345 in 9) Pipe & flange inside diameter 3.152 in 10) Flange type RAISE FACE 11) Drain hole diameter Not required 12) Element thickness .125 in 13) Option Flange 1) Flange type RAISE FACE data 2) Flange material Carbon steel 3) Supplied with flow element 4) Flange rating & facing 900# RF 5) Option Tap data 1) Pressure tap location Flange taps 2) Pressure tap size Flowmeter 1) Sensor type data 2) Differential range 200 inH2O 3) Static pressure range 4) Chart or scale range 5) Chart multiplier 400000 Process 1) Service data 2) Line number 3) Fluid name NG 4) Fluid state Gas 5) Maximum flowrate 4000000 sft3/d 6) Normal flowrate 1700000 sft3/d 7) Operating pressure 1600 psig 8) Operating temperature 68.19 degF 9) Operating density 7.087 lb/ft3 10) Molecular weight 18.6 11) Cp/Cv specific heat ratio 1.868 12) Operating viscosity .0159 cp 13) Barometric pressure 14.7 psia 14) Calibration temperature 68 degF 15) Base temperature 60 degF 16) Base pressure 14.73 psia Notes