0% found this document useful (0 votes)
548 views7 pages

Accutrend Plus: Quick Reference Guide

This document provides instructions for using the Accutrend Plus meter to measure glucose and cholesterol levels in capillary whole blood samples. The meter codes test strips, prompts insertion of blood samples onto strips inside or outside the meter, and displays measurement results after 12 seconds for glucose or 180 seconds for cholesterol. It is intended for professional and self-testing use according to manufacturer instructions.

Uploaded by

danialedu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
548 views7 pages

Accutrend Plus: Quick Reference Guide

This document provides instructions for using the Accutrend Plus meter to measure glucose and cholesterol levels in capillary whole blood samples. The meter codes test strips, prompts insertion of blood samples onto strips inside or outside the meter, and displays measurement results after 12 seconds for glucose or 180 seconds for cholesterol. It is intended for professional and self-testing use according to manufacturer instructions.

Uploaded by

danialedu
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Accutrend Plus

Quick Reference Guide

This is a CLIA waived system.


The Accutrend Plus meter is used for
the quantitative measurement of
­glucose and cholesterol in capillary
whole blood. The meter is suitable
for professional use as well as for
self-­testing.

 lease note:
P
This Quick Reference Guide is
not intended as an alternative
to reading the User’s Manual.
Please read the Accutrend
Plus User’s Manual carefully
before using the meter for the
first time.

1 Place the meter on a level surface or


hold it steady in your hand. Switch the
meter on.

2 Ensure that the display is on and that all


display elements are displayed correctly.
Check the time and date (if you want to
save this information with the result).
If no code has ever been stored,
codenr flashes with three dashes.
Otherwise the last stored code is
­displayed.

You must code the meter


every time you open a new
test strip container.

3 Insert a code strip as shown. Do not


touch the printed area behind the black
bar or on the back of the strip.

4 With the chamber flap closed, insert


the code strip as far as it will go and
remove it immediately.

5 Successful coding is confirmed by a


short beep (if the beeper option is
enabled) and the code is displayed
by the meter. If an error occurs or if
the code is not displayed, repeat
the process after a few seconds.
6 Remove an Accutrend Cholesterol test
strip from the container. Always close
the container again immediately. The
cap contains a drying agent to protect
the strips from ­humidity.

7 Hold the test strip as shown and insert


it as far as possible. If the strip is correctly
inserted you will hear two beeps (if the
beeper option is enabled). The code
number of the Accutrend Cholesterol
test strip is displayed.
8 Open the measurement chamber flap.

9 Use a lancing device to pierce a finger


and obtain a hanging drop of blood.

CH
OL

CH
OL
You can apply blood with the strip
inside or outside the meter.
To avoid incorrect results, make sure
the application area is completely
covered with blood.

10 For blood application inside the meter:


Apply the hanging drop of blood
immediately from the finger to the
yellow application area of the Accutrend
Cholesterol test strip. Do not touch the
application area with your ­finger.
Continue with step (12).

11 For blood application outside the meter:


Remove the Accutrend Cholesterol test
strip and leave the flap open. Apply the
hanging drop of blood immediately
from the finger to the ­yellow application
area of the test strip. Do not let the
application area come into contact with
your skin. Insert the Accutrend
Cholesterol test strip back into the
meter.
12 Close the flap to start the cholesterol
measurement.

Measurement starts.
Result displays after:

Glucose: 12 seconds
Cholesterol: 180 seconds

When the measurement is complete


the meter beeps (if the beeper
option is enabled) and the result is
displayed.
Results falling outside the
measurement range are displayed as
Hi (above the measurement range)
or Lo (below the measurement
range).

To perform a Glucose test, follow the


same simple steps using the
Accutrend Glucose test strip.
This is a CLIA waived system. Laboratories with a
certificate of waiver must follow the manufacturer's
instructions for performing the test.
42 CFR 493.15(e)(1).

For technical assistance:


call 1-800-440-3638
24 hours a day, 7 days a week.

0123

ACCUTREND and COBAS


are trademarks of Roche.

Manufactured for and


distributed in the U.S.A. by
Roche Diagnostics
9115 Hague Road
Indianapolis, IN 46256

Made in Germany
0 5340497001 (03) 2012-07 USA

Roche Diagnostics GmbH


Sandhofer Strasse 116
68305 Mannheim
Germany

www.roche.com

You might also like