Data sheet 3UG4822-1AA40

Digital monitoring relay Current monitoring, 22.5 mm for


IO-Link 0.05...10.0 A AC/DC Overcurrent and
undercurrent Transformer scaling factor Hysteresis 0.01
to 5.0 A ON-delay time Tripping delay time 1 change-
over contact, screw terminal

Product function Current monitoring relay

Measuring circuit:
Number of poles for main current circuit 1
Type of current for monitoring AC/DC
Measurable current A 0.05 ... 10
Measurable current at AC mA 50 ... 750 000
Measurable line frequency Hz 500 ... 40
Adjustable pick-up value current
●1 A 0.05 ... 10
●2 A 0.05 ... 10
Adjustable response delay time
● when starting s 0 ... 999.9
● with lower or upper limit violation s 0 ... 999.9
Adjustable switching hysteresis for measured current mA 5 ... 10
value
Operating voltage rated value V 24 ... 24
Response time maximum ms 450
Relative metering precision % 5
Accuracy of digital display +/-1 digit

3UG4822-1AA40 Subject to change without notice


Page 1/7 11/12/2018 © Copyright Siemens
Relative temperature-related measurement deviation % 5
Relative repeat accuracy % 1

General technical data:


Design of the display LCD
Product function
● Overcurrent detection 1 phase Yes
● Overcurrent detection 3 phase No
● undercurrent detection 1 phase Yes
● undercurrent detection 3 phases No
● Overcurrent detection DC Yes
● undercurrent detection DC Yes
● Current window recognition DC Yes
● External reset Yes
● Auto-reset Yes
● Adjustable open/closed-circuit current principle Yes
Starting time after the control supply voltage has ms 1 000
been applied
Type of voltage of the supply voltage DC
Supply voltage
●1
— at DC rated value V 24
— at DC V 18 ... 30
Surge voltage resistance rated value kV 6
Consumed active power W 2
Protection class IP IP20
Electromagnetic compatibility IEC 60947-1 / IEC 61000-6-2 / IEC 61000-6-4
Vibration resistance acc. to IEC 60068-2-6 1 ... 6 Hz: 15 mm, 6 ... 500 Hz: 2g
Shock resistance acc. to IEC 60068-2-27 sinusoidal half-wave 15g / 11 ms
Installation altitude at height above sea level m 2 000
maximum
Conducted interference due to burst acc. to IEC 2 kV
61000-4-4
Conducted interference due to conductor-earth surge 2 kV
acc. to IEC 61000-4-5
Conducted interference due to conductor-conductor 1 kV
surge acc. to IEC 61000-4-5
Electrostatic discharge acc. to IEC 61000-4-2 6 kV contact discharge / 8 kV air discharge
Field-bound parasitic coupling acc. to IEC 61000-4-3 10 V/m
maximum permissible voltage for safe isolation
● between control and auxiliary circuit V 690
Degree of pollution 2
Ambient temperature
● during operation °C -25 ... +60

3UG4822-1AA40 Subject to change without notice


Page 2/7 11/12/2018 © Copyright Siemens
● during storage °C -40 ... +85
● during transport °C -40 ... +85
Galvanic isolation
● between entrance and outlet Yes
● between the voltage supply and other circuits Yes

Communication/ Protocol:
Type of voltage supply via input/output link master Yes
IO-Link transfer rate COM2 (38,4 kBaud)
Protocol is supported IO-Link protocol Yes
Amount of data
● of the address area of the outputs with cyclical byte 2
transfer total
● of the address area of the inputs with cyclical byte 4
transfer total
Point-to-point cycle time between master and IO-Link ms 10
device minimum

Mechanical data:
Width mm 22.5
Height mm 92
Depth mm 91
Mounting position any
Required spacing for grounded parts
● forwards mm 0
● Backwards mm 0
● at the side mm 0
● upwards mm 0
● downwards mm 0
Required spacing with side-by-side mounting
● forwards mm 0
● Backwards mm 0
● at the side mm 0
● upwards mm 0
● downwards mm 0
Required spacing for live parts
● forwards mm 0
● Backwards mm 0
● at the side mm 0
● upwards mm 0
● downwards mm 0
Mounting type snap-on mounting
Type of electrical connection
● for auxiliary and control current circuit screw-type terminals

3UG4822-1AA40 Subject to change without notice


Page 3/7 11/12/2018 © Copyright Siemens
● for main current circuit screw-type terminals
Product function
● removable terminal for auxiliary and control Yes
circuit
● removable terminal for main circuit Yes
Type of connectable conductor cross-sections
● solid 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²)
● finely stranded
— with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
● at AWG conductors
— solid 2x (20 ... 14)
— stranded 2x (20 ... 14)
Tightening torque with screw-type terminals N·m 0.8 ... 1.2

Outputs:
Number of NO contacts delayed switching 0
Number of NC contacts delayed switching 0
Number of CO contacts delayed switching 1
Ampacity
● of the output relay
— at AC-15
— at 250 V at 50/60 Hz A 3
— at 400 V at 50/60 Hz A 3
— at DC-13
— at 24 V A 1
— at 125 V A 0.2
— at 250 V A 0.1
● for permanent overcurrent maximum A 15
permissible
Operating current at 17 V minimum A 0.01
Continuous current of the DIAZED fuse link of the A 4
output relay
Thermal current of the switching element with A 5
contacts maximum
Mechanical service life (switching cycles) typical 10 000 001
Electrical endurance (switching cycles) at AC-15 at 100 000
230 V typical
Operating frequency with 3RT2 contactor maximum 1/h 5 000

Certificates/ approvals:

3UG4822-1AA40 Subject to change without notice


Page 4/7 11/12/2018 © Copyright Siemens
General Product Approval EMC Declaration of
Conformity
Manufacturer De-
claration

Test Certificates other Railway


Type Test Certific- Special Test Certi- Confirmation Vibration and Shock
ates/Test Report ficate

Further information
Information- and Downloadcenter (Catalogs, Brochures,…)
http://www.siemens.com/industrial-controls/catalogs
Industry Mall (Online ordering system)
http://www.siemens.com/industrymall
Cax online generator
http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3UG4822-1AA40
Service&Support (Manuals, Certificates, Characteristics, FAQs,...)
https://support.industry.siemens.com/cs/ww/en/ps/3UG4822-1AA40
Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...)
http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3UG4822-1AA40&lang=en

3UG4822-1AA40 Subject to change without notice


Page 5/7 11/12/2018 © Copyright Siemens
22,5 5,1 85,9
91,9

3UG4822-1AA40 Subject to change without notice


Page 6/7 11/12/2018 © Copyright Siemens
C/Q
L+

11
IN

L-
<I>

IO-Link

12

14
M

last modified: 10/23/2018

3UG4822-1AA40 Subject to change without notice