Lampiran A Perhitungan Pompa

This document provides calculations for two centrifugal pumps (P-402 and P-401) used to transfer water and methanol, respectively. It includes calculations of flow rate, density, viscosity, pipe diameter, friction losses, pump power requirement, motor power, and net positive suction head (NPSH). Pump P-402 transfers water at 1007.6 kg/hr, has a 0.5 HP motor requirement, and has sufficient NPSH with 1.36 ft of line losses. Pump P-401 transfers methanol from a condenser to a storage tank.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
188 views20 pages

Lampiran A Perhitungan Pompa

This document provides calculations for two centrifugal pumps (P-402 and P-401) used to transfer water and methanol, respectively. It includes calculations of flow rate, density, viscosity, pipe diameter, friction losses, pump power requirement, motor power, and net positive suction head (NPSH). Pump P-402 transfers water at 1007.6 kg/hr, has a 0.5 HP motor requirement, and has sufficient NPSH with 1.36 ft of line losses. Pump P-401 transfers methanol from a condenser to a storage tank.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 20

LAMPIRAN A

PERHITUNGAN POMPA

A.2 Lembar Perhitungan Pompa 1

LEMBAR PERHITUNGAN
Nama Alat Pompa H2O Kode Alat
Fungsi Mengalirkan H2O keluar dari kolom destilais (D-401)
P-402
Tipe Centrifugal Pump

Gambar A.2 Pompa 1 (P-402)

Tabel Neraca Massa untuk Aliran Masuk Pompa H2O


Komponen Komposisi (%) Laju Alir Massa (kg/jam)
H2O 100 1007,6
Data Perancangan
Temperature (T) = 65oC
= 338,15 K
Laju Alir Massa (F) = 1007,6 kg/h
= 2221,38 lb/h
Tabel Data Densitas Komponen
Komponen A B N TC (K)
H2O 0,347 0,274 0,286 647,13
(Sumber : Yaws, 1999)
Untuk mendapatkan densitas komponen pada T = 65oC digunakan persamaan :
𝑛
𝜌 = 𝐴𝐵 −(1−𝑇/𝑇𝑐) [Yaws, 1999]
0,286
𝜌𝐻2𝑂 = (00,3471)(0,274)−(1−338/647,13
𝜌𝐻2𝑂 = 0,99003 g/ml
𝜌𝐻2𝑂 = 990,0356 kg/m3
𝜌𝐻2𝑂 = 61,8059 lb/ft3

Tabel Data Viskositas Komponen


Komponen A B C D
H2O -10,216 1792,5 0,01773 -0,000013
(Sumber : Yaws, 1999)

Untuk mendapatkan viskositas komponen pada T = 65oC digunakan persamaan :


𝐵
𝐿𝑜𝑔10 𝜇𝐻2𝑂 = 𝐴 + 𝑇 + 𝐶𝑇 + 𝐷𝑇 2 [Yaws, 1999]
1792,5
𝐿𝑜𝑔10 𝜇𝐻2𝑂 = −10,216 + + (0,001773𝑥 338) + (−0,000013) (3382 )
338

𝐿𝑜𝑔10 𝜇𝐻2𝑂 = 0,033


𝜇𝐻2𝑂 = 100,033
𝜇𝐻2𝑂 = 7,33487𝐸 − 06cp
𝜇𝐻2𝑂 = 4,92882 𝐸 − 09 lb/ft.s

Data Perancangan

Temperatur, T : 65 oC = 338 K
Tekanan, P : 1 atm
Laju alir massa, F : 1007,6 kg/jam = 2221,38 lbm/jam
Densitas komponen : 990,03564 kg/m3= 61,8059 lbm/ft3
Viskositas komponen, μ = 4,92882.10 -9 lbm/ft. s
Faktor keamanan (Over Design ): 10% [Peters & Timmerhaus, 2003 : Tabel 6]

Konsep Perancangan :
 Laju Volumetrik Cairan Melewati Pompa (Q)
𝐹
Q =𝜌
1007,6
= 990,0356437

= 0,009983299 ft3/s

Q desain = Q x (1+ over desgin)


= 0,009983299 f 3/s x 1,1
= 0,011979959 ft 3/s
= 5,377324529 gpm

Diasumsikan aliran fluidanya adalah turbulen (NRe > 2100)


 Diameter Optimum untuk Aliran Turbulen
Dioptimum = 3,9Q0,45ρ0,13 [Peters & Timmerhaus, 2003 : Pers. 45]
= 3,9 (0,0099832990,45) (61,805905570,13)
= 0,838632805 in
Digunakan data steel pipe, nominal pipe size 1 in (Geankoplis, 1993 : Appendix
A.5-1) dengan spesifikasi :
Schedule Number = 40
Outside Diameter (OD) = 1,32 in = 0,11 ft
Inside Diameter (ID) = 1,049 in = 0,08741667 ft

Flow Area (At) =0,055741824 m2 = 0,006 ft2


 Kecepatan Linear Aliran (v)
𝑄
v = At
0,011979959
= 0,006

= 1,996659882 ft/s

 Reynold Number (NRe)


𝐼𝐷 𝑥 𝑣 𝑥 𝜌
NRe = [Geankoplis, 1993 : Pers. 2.5-1]
µ
(0,08741667) 𝑥 (1,996659882) 𝑥 (61,80590557)
= 4,92882 E−09

= 2188697584 (aliran turbulen > 2100)

Menghitung Friction Losses Aliran Fluida


 Friksi Pada Pipa Lurus (Ff)
Asumsi panjang pipa lurus (ΔL = 20 m = 65,608 ft)
Nilai faktor friksi (f) untuk aliran turbulen dapat ditentukan melalui Gambar 2.10-
3, sehingga didapat nilai f = 0,0067 (dengan nilai ε untuk commercial steel pipe
adalah 0,000046 m dan ID 0,0266446 m = 0,087416667 ft , sehingga ε/ID =
0,001726429 m), Maka :
𝛥𝐿 𝑣 2
Ff = 4𝑓 [Geankoplis, 1993 : Pers. 2.10-6]
𝐷 2𝑔𝑐

= 1,3017 lb89485f.ft/lbm

 Friksi pada Fitting dan Valve (hf)


Tabel Friction Losses Aliran Turbulen yang Melewati Fitting dan Valve
Equipment Jumlah (n) Kf n.Kf
Elbow 90o 4 0,75 1,5
Gate Valve (wise 2 0,17 0,17
open)
Total 1,67
(Sumber : Geankoplis, 1993 : Tabel. 2.10-2)
𝑣2
hf elbow = 𝑛. 𝐾𝑓 2𝑔 [Geankoplis, 1993 : Pers. 2-10-17]
𝑐

0,5425952
= (1,67) 2(32,174)

= 0,185863617 lbf.ft/lbm

Total Friksi (ΣF) = Ff +hf + hc+ hex [Geankoplis, 1993 : Pers. 2.10-18]
= (1,301789485) + (0,185863617) + (0,021064543)
= 1,5087 lbf.ft/lbm

 Perhitungan Daya Pompa (BHP)


Daya pompa ditentukan dengan Mechanical Energy Balance Equation
(Geankoplis, 1993 : Pers. 2.7-28) :
1 𝑔 𝑃2 −𝑃1
(𝑣22 − 𝑣12 ) + (𝑧2 − 𝑧1 ) + + 𝛴𝐹 + 𝑊𝑠 = 0
2𝑔𝑐 𝛼 𝑔𝑐 𝜌

Asumsi :
v1 = v2, P1 = P2, sehingga Δv dan ΔP = 0; z1 = 1 dan z2 = 10 m = 32,808 ft, dengan
percepatan gravitasi (gc) = 32,174 ft/s2, sehingga :
𝑔
−𝑊𝑠 = (𝑧2 − 𝑧1 ) + 𝛴𝐹
𝑔𝑐

−𝑊𝑠 = 30,677215 lbf.ft/lbm

Daya pompa (BHP) dihitung menggunakan rumus :


𝑊𝑝 𝑚
𝐵𝐻𝑃 = [Geankoplis, 1993 : Pers. 3.3-2]
550

Dari Gambar 14.37 (Peters & Timmerhaus, 2003) dengan kapasitas, Q = 4,3606
gal/min maka diperoleh efesiensi pompa (η) = 42%
Laju Alir Massa :
m = Q.ρ
= (0,010687) (63,5121)
= 0,678754 lb/s

Power Pompa :
− 𝑊𝑠
𝑊𝑝 = [Geankoplis, 1993 : Pers. 3.3-1]
𝜂
30,677215
𝑊𝑝 = 0,48

𝑊𝑝 = 63,910864 ft.lbf/lbm

(0,678754 )(63,910864)
Maka, 𝐵𝐻𝑃 = = 0,034694319 hp
550

Dipakai pompa dengan daya sebesar = 0,5 HP ; 3500 rpm (Fig 5.6 Coulson)
 Perhitungan Daya Motor (P)
𝐵𝐻𝑃
𝑃 =
𝜂𝑚
Dari Gambar 14.38 (Peters & Timmerhaus, 2003) dengan daya pompa, BHP =
0,28185 hp maka diperoleh efesiensi motor (ηm) = 80%
Sehingga ,
0,034694319
𝑃 = 80%

𝑃 = 0,5/80% hp

= 0,043367899

Dipakai motor induksi tiga fassa dengan daya = 0,125 HP (Standar HP by NEMA)

 Menghitung NPSH Pompa

*Absolut pressure

Abs press = (p*2,30)/specific grafity (rule of thumb, p.82)

P sist = 1,1406 atm = 16,76682 psi

Sp gravity = densitas/62,4

= 0,99047926
Maka

Abs press =38,9343702 ft

*Vapor Pressure

Vapor pressure = Pi*2,30/SG (Yaws, tabel 7.1)

Log10 (P) =A+B/T+C log10(T)+D*T+E*T^2 P(mmHg),


T (K)

Komp A B C D E
H2O 29.8605 -3.15E+03 -7.30E+00 2.42E-09 1.81E-06

Komp Xi Pi Pi. Xi
H2O 1 1.8776E+02 1.8776E+02
Total 1 1.8776E+02

Pi campuran = 1,8776E-02 = 3,63062 psi


Vapour pressure = 8,430683422 ft

*Line Loss
Line loss = line loss karena 1 gate valve + 1 elbow + pipa lurus
1 gate valve = 0,010532272 ft.ibf/lbm
1 elbow = 0,046465904 ft.ibf/lbm
Friksi pipa lurus sepanjang = 114,80 ft = 1,301789485 ft
Line loss = 1,358787661 ft

*Different in elevation
= 11,48
NPSH Available = 38,93437018 – 1,358788 + 11,48
= 49,05558251 ft

Dari Carl R Branan, p.83 diperoleh persamaan:


n = kecepatan putar = 3500 (kecepatan motor yang
sering digunakan)
Q = kapasitas gpm = 5,377324529 gpm
C = konstanta = 9000

Diperoleh
NPSH required = 0,871254187
NPSH available > NPSH required, pompa tidak akan mengalami kavitasi
A.2 Lembar Perhitungan Pompa 2
LEMBAR PERHITUNGAN
Nama Alat Pompa Metanol Kode Alat
Mengalirkan Metanol Dari Kondensor Menuju Tangki
Fungsi
Penyimpanan (T-201) P-401
Tipe Centrifugal Pump

Gambar A.2 Pompa (P-401)

1. Jenis Pompa
Pompa yang digunakan adalah jenis centrifugal pump dengan pertimbangan,
yaitu :
 Dapat digunakan range kapasitas yang besar
 Konstruksinya sederhana sehingga harganya relatif lebih murah
 Tidak memerlukan area yang luas
 Kecepatan putarannya stabil
2. Menghitung Power Pompa Dan Motor
A. Kapasitas, Q

Tabel Neraca Massa untuk Aliran Masuk Pompa (P-402)


Komponen BM F (kg/jam) wi kmol/jam xi
5,44953E- 0,08409777 9,68765E-
H2O 18 1,51376 05 8 05
0,99994550 0,99990312
CH3OH 32 27776,28 5 868,00875 4
868,092847
Total 27777,79376 1 8 1

Data Perancangan
Temperature (T) = 30 oC
= 303 K
Laju Alir Massa (F) = 27777,8 kg/h
= 61239,6 lb/h

Tabel Data Densitas Komponen


ρL
Komp A B n Tc (g/mL) wi/ρL
H2O 0,3471 0,274 0,28571 647,13 1,0228753 5,32766E-05
CH3OH 0,272 0,2719 0,2331 512,58 0,7828017 1,277393182
Total 1,8056769 1,277446459
(Sumber : Yaws, 1999)
Untuk mendapatkan densitas komponen pada T = 30 oC digunakan persamaan :
𝑛
𝜌 = 𝐴𝐵 −(1−𝑇/𝑇𝑐)
[Yaws, 1999]
 Densitas Cairan
ρL
Komp A B n Tc F wi wi/ρL
(g/mL)
H2O 0,3471 0,274 0,28571 647,13 1,02301 1,51376 5,4495E-05 5,3269E-05
CH3OH 0,272 0,2719 0,2331 512,58 0,78294 27776,28 0,9999455 1,27716783
Total 27777,79 1 1,2772211
𝜌𝑐𝑎𝑚𝑝𝑢𝑟𝑎𝑛 = 1/𝛴(𝑤𝑖/𝜌𝐿))
𝜌𝑐𝑎𝑚𝑝𝑢𝑟𝑎𝑛 = 0,7829 g/ml
𝜌𝑐𝑎𝑚𝑝𝑢𝑟𝑎𝑛 = 782,8116 kg/m3
𝜌𝐶𝑎𝑚𝑝𝑢𝑟𝑎𝑛 = 48,8778 lb/ft3
27777,79 kg/jam
Q = 782,8116 kg/m3

= 35,4846 m3/jam
= 0,0099 m3/s
= 0,3480 ft3/s
Faktor keamanan = 10%
Q perancangan = 𝑄 + (𝑓𝑎𝑘𝑡𝑜𝑟 𝑘𝑒𝑎𝑚𝑎𝑛𝑎𝑛 𝑥 𝑄)
= 39,0331 m3/jam
= 0,4176 ft3/s
= 187,4862 gpm
Dipakai pompa sejumlah 1 buah

Dari tabel 10.17 coulson untuk kapasitas perancangan diatas dapat digunakan pompa
sentrifugal.

 Menghitung diameter optimum pipa


Asumsi = aliran turbulen
D = 3,9 Q0,45 ρ0,13 (walas, pers. 6.32)
Q = 0,3480 ft3/s
ρ = 48,8693 lb/ft3
d = 4,0215 in
Digunakan data steel pipe, nominal pipe size 4 in (Geankoplis, 1993 : Appendix
A.5-1) dengan spesifikasi :
Schedule Number = 40
Outside Diameter (OD) = 4,5 in = 0,37485 ft
Inside Diameter (ID) = 4,026 in = 0,33536 ft
Flow Area (At) = 12,7 in2 = 0,0881 ft2

 Kecepatan Linear Aliran (v)


𝑄
v = At
0,4176 ft3/s
= 0,0881 ft2

= 4,7360 ft/s

 Menghitung viskositas cairan pada temperatur 303,15 K


𝐵
𝐿𝑜𝑔10 𝜇𝐻2𝑂 = 𝐴 + 𝑇 + 𝐶𝑇 + 𝐷𝑇 2 [Yaws, 1999]

Komp A B C D μi xi/μi
H2O -10,2158 179,25 0,01773 -1,26E-05 3,89E-06 2,49E+01
CH3OH -9,0562 1254,2 0,022383 -2,35E-05 5,05E-01 1,98E+00
Total 26,9067

1
μc = xi/µi
1
= 26,9067

= 0,0371 cp
= 2,4974E-05 lb/ft.s
 Reynold Number (NRe)

𝐼𝐷 𝑥 𝑣 𝑥 𝜌
NRe = [Geankoplis, 1993 : Pers. 2.5-1]
µ
(0,3355) 𝑥 (4,7360) 𝑥 (48,8693)
= 2,4974E−05

=3109261,969 (aliran turbulen > 2100)


 Neraca tenaga mekanis
Dihitung dengan persamaan bernoulli
v 2 z.g P
 Ws    F
2 .gc gc 
Dengan :
Ws = tenaga yang ditambahkan kedalam sistem, ft.lbf/lbm
Δv = perbedaan kecepatan fluida pipa masuk dan keluar pompa , ft/s
a = konstanta, untuk aliran turbulen
Δz = beda ketinggian cairan, ft
Δp = beda tekanan, lbf/ft2
ΣF = friction loss, ft.lbf/lbm
g = konstanta gravitasi ( 32,174 ft/s2)
gc = gravitational conversion factor ( 32,174 lbm.ft/lbf.s2)
Δv2/2.a.gc = beda tenaga kinetik fluida, ft.lbf/lbm
Δz.g/gc = beda tenaga potensial, ft.lbf/lbm
Perhitungan :
 Beda energi kinetik
Diameter pipa yang digunakan sama maka kecepatan fluidanya juga sama,
sehingga :
Δv2 = 0, sehingga Δv2/2.a.gc = 0 ft.lbf/lbm

 Beda energi potensial


Z1 = 6,56 ft = 2,00 m
Z2 = 21,32 ft = 6,50 m
Δz.g/gc = 1476 ft.lbf/lbm

 Beda tekanan
P1 = 1,1406 atm = 2414,42 lbf/ft2
P2 = 1,1406 atm = 2414,42 lbf/ft2
ΔP/ρ = 0 ft.lbf/lbm

Menghitung Friction Losses Aliran Fluida


 Friksi Pada Pipa Lurus (Ff)
Untuk pipa dipilih dari bahan = commercial steel pipe
Nre = 3109261,969
Asumsi panjang pipa lurus (ΔL = 20 m = 65,608 ft)
Nilai faktor friksi (f) untuk aliran turbulen dapat ditentukan melalui Gambar 2.10-
3, sehingga didapat nilai f = 0,004 (dengan nilai ε untuk commercial steel pipe
adalah 0,000046 m dan ID 0,10226 m = 0,3354 ft , sehingga ε/ID = 0,00044 m),
Maka :
𝛥𝐿 𝑣 2
Ff = 4𝑓 [Geankoplis, 1993 : Pers. 2.10-6]
𝐷 2𝑔𝑐

65,608 (4,7360)2
= 4(0,004) 0,3355 2(32,174)

= 1,0905 lbf.ft/lbm

 Friksi pada Fitting dan Valve (hf)


Tabel Friction Losses Aliran Turbulen yang Melewati Fitting dan Valve
Equipment Jumlah (n) Kf
o
Elbow 90 3 0,75
Gate Valve (wise open) 1 0,17
(Sumber : Geankoplis, 1993 : Tabel. 2.10-2)
 Friksi di elbow 90
𝑣2
hf = 𝐾𝑓 [Geankoplis, 1993 : Pers. 2-10-17]
2𝑔𝑐

(4,7360)2
= (0,75) 2(32,174)

= 0,261 lbf.ft/lbm untuk 1 elbow


= 0,7842 lbf.ft/lbm untuk 3 elbow
 Friksi di gate valve
𝑣2
hf = 𝐾𝑓 2𝑔 [Geankoplis, 1993 : Pers. 2-10-17]
𝑐

(4,7360)2
= (0,17) 2(32,174)

= 0,0592 lbf.ft/lbm untuk 1 gate valve


= 0,0592 lbf.ft/lbm untuk 1 gate valve
 Total friksi
Total Friksi (ΣF) = Ff +hf + hc+ hex [Geankoplis, 1993 : Pers. 2.10-18]
F = 1,0905 + 0,7842 + 0,0592
= 1,9341 ft.lbf/lbm
Dari persamaan bernouli didapatkan :
-ws = 16,69 ft.lbf/lbm
Head pompa = 16,69 ft = 5,0884 m

 Perhitungan Daya Pompa (BHP)


Daya pompa ditentukan dengan Mechanical Energy Balance Equation
(Geankoplis, 1993 : Pers. 2.7-28) :
𝑄𝑥 𝑟
−𝑤𝑠
550 𝑥 ℎ

Kapasitas pompa = 187,4862 gpm = 39,0331 m3/jam = 650,565 l/menit


Dari Fig. 14,37 petter n timmerhaus diperoleh efisiensi pompa sentrifugal = 70 %
𝑊𝑝 𝑚
𝐵𝐻𝑃 =
550
0,3480 𝑥 48,8693
BHP = 16,69 550 𝑥 70%

= 0,7375 hp
Diapakai pompa dengan daya sebesar= 1 hp ; 3500 rpm (dilihat pada figure 14.37 )
 Perhitungan Daya Motor (P)
𝐵𝐻𝑃
𝑃 =
𝜂𝑚
Dari Gambar 14.38 (Peters & Tim merhaus, 2003) dengan daya pompa, BHP =
0,7375 hp maka diperoleh efesiensi motor (ηm) = 80%
Sehingga ,
0,7375
𝑃 = 80%

𝑃 = 0,9219 hp
= 0,6875 kW
= 688 Watt

 Menghitung NPSH ( Net Positive Suction Head ) pompa


NPSH Available = Abs press – Vap Press – line loss + Elevation diff
Abs press = Tekanan absolut fluida yang akan dipompa
= Gauge pressure + atmosferic pressure ( ft )
Vap Press = Tekanan uap cairan ( ft )
Line loss = Friction loss sebelum suction pompa ( ft )
Elev diff. = Beda ketinggian antara pompa dan cairan yg di pompa (ft)
 Absolute pressure
𝑃 𝑥 2,30
Abs = 𝑠𝑝𝑒𝑐𝑖𝑓𝑖𝑐 𝑔𝑟𝑎𝑣𝑖𝑡𝑦

P = 1,1406 atm = 16,7668 psi


ρ L = 48,8693 lb/ft3
𝑑𝑒𝑛𝑠𝑖𝑡𝑎𝑠
sp.gravity = 62,4

= 0,7831
Maka , :
Abs press = 49,240 ft
 Vapour pressure
𝑃𝑖 𝑥 2,30
Vapour press = 𝑠𝑝𝑒𝑐𝑖𝑓𝑖𝑐 𝑔𝑟𝑎𝑣𝑖𝑡𝑦 (yaws, tabel 7.1)

log10 (P) = A + B/T +C log10 (T) +D*T + E*T2


Komp A B C D E
- 2,42E-
H2O 29,8605 3,15E+03 -7,30E+00 09 1,81E-06
- 6,64E-
CH3OH 45,6171 3,24E+03 -0,3988 03 -1,05E-13

Komp Xi Pi Pi. Xi
H2O 9,68765E-05 3,1865E+01 3,0870E-03
CH3OH 0,999903124 8,6295E+35 8,6287E+35
Total 1 8,6287E+35
Pi campuran = 8,6287E+35 mmHg = 1,7E+34 psi
Vapour pressure = 4,9001E+34 ft

 Line loss
Line loss = line loss karena 1 gate valve + 1 elbow + pipa lurus
1 gate valve = 0,0592 ft.lbf/lbm
1 elbow = 0,2614 ft.lbf/lbm
Friksi pipa lurus sepanjang 65,60 ft = 1,0905 ft
Line loss = 1,4112 ft

 Difference in elevation
Difference in elevation = 14,76 ft
NPSH Available = 49,240 – 1,4112 + 14,76
= 62,5897 FT
Dari Carl R Branan, p.83 diperoleh
persamaan :
n(Q)0.5/(NPSH)0.75 = C

n = kecepatan putar, rpm = 3500


(kecepatan motor yang umum digunakan)
Kapasitas,gp gp
Q = m = 187,4862295 m
C = Konstanta = 9000
diperoleh :
9,2985157
NPSH required = 26
NPSH availabel > NPSH required, pompa tidak akan mengalami
kavitasi.