Subject: Power System Analysis - 2 Subject Code: 15EE71 Model Question Paper Marks

This document contains a 10 question, 16 part model question paper for the subject of Power System Analysis - 2. The questions cover a range of topics in power system analysis including load flow analysis using Gauss-Seidel and Newton-Raphson methods, economic load dispatch, optimal unit commitment, and power system stability and reliability evaluation. Sample problems are provided with several questions that involve calculating voltages, power flows, incremental fuel costs, or forming bus impedance matrices for given power systems.

Uploaded by

Vinod Kohli
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
148 views2 pages

Subject: Power System Analysis - 2 Subject Code: 15EE71 Model Question Paper Marks

This document contains a 10 question, 16 part model question paper for the subject of Power System Analysis - 2. The questions cover a range of topics in power system analysis including load flow analysis using Gauss-Seidel and Newton-Raphson methods, economic load dispatch, optimal unit commitment, and power system stability and reliability evaluation. Sample problems are provided with several questions that involve calculating voltages, power flows, incremental fuel costs, or forming bus impedance matrices for given power systems.

Uploaded by

Vinod Kohli
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Subject: Power System Analysis – 2 Subject Code: 15EE71

Model Question Paper


Q. No. Question Marks
1. a Define a primitive network. Formulate YBus by singular transformation 8
method.
b. In the power system shown in Fig. Q1(b), line 1-2 has the series impedance 8
of (0.04+j0.12) pu with negligible line charging. The generation and load
data is given in the table.
Bus No. Type Generation (pu) Load (pu)
1 Slack - - - -
2 PV 0.3 - 0.6 0.2
The slack bus voltage is (1+j0). The voltage magnitude at bus 2 is to be
maintained at 1.05 pu and the generator at this bus has Q-generation limits
between 0 and 0.5 pu. With (1+ j0) pu initial voltage at bus 2, determine its
voltage at the end of first iteration, using GS load flow model.

Fig. Q1(b)
Or
2. a Develop the Gauss-Seidel load flow model for a power system with a slack 8
. bus and (n-1) number of PQ buses. Write the flow chart of the algorithm.
b Determine YBus by singular transformation for the system with data as 8
. below:
Element No. 1 2 3 4 5
Bus Code p-q 0-1 0-2 2-3 3-0 2-0
Self-admittance in pu 1.4 1.6 2.4 2.0 1.8
3.a Derive expressions for diagonal elements of NR jacobian submatrices in 8
polar form.
b. In a two bus system shown in Fig. Q3(b), bus 1 is slack bus with V1=1.0∠0 8
pu and bus 2 is a load bus with P = 100 MW, Q = 50 MVar. The line
impedance is (0.12+j0.16) pu on a base of 100 MVA. Using NR load flow
method compute |V2| and δ2 after one iteration.

Fig. Q3(b)
Or
4.a Explain the algorithm with fast decoupled load flow analysis, clearly stating 8
all the assumptions mad.
b. Explain how the voltage profile is controlled in an interconnected power 8
system (i) by adjusting generator excitation, (ii) by VAR generators
5.a. Draw and explain the following: 8
i) Input-Output curve
ii) Cost Curve
iii) Incremental cost curve
iv) Heat rate curve
b. The incremental fuel costs in Rs/MWh for a plant consisting of two units 8
are
ௗிభ ௗி
= 0.1ܲீଵ + 20, మ = 0.12ܲீଶ + 15.
ௗ௉ಸభ ௗ௉ಸమ
Assume that both units are operating at all times.
Determine
i) The most economical division of load between the generators for a
constant load of 300 MW.
ii) The saving in Rs./ day obtained compared to equal load sharing
between the
Or
6.a. Derive the coordination equations for economic load dispatch in a thermal 8
power system with the consideration of transmission losses.
b. Describe dynamic programming method for computation of optimal Unit 8
Commitment.
7.a Write a flow chart for the optimal load flow solution. 8
b. Explain the state space method used for power system reliability evaluation. 8
Explain Loss Of Load Probability (LOLP)
Or
8.a. Discuss the optimal scheduling of hydrothermal system. 8
b. Explain power system security assessment and modelling for contingency 8
analysis
9.a. Derive the generalized algorithm for finding the elements of bus impedance 8
matrix when a link is added.
b. Discuss the steps for determining multimachine stability. 8
Or
10.a. Explain point by point method of solving swing equation. 8
b. Form the ZBus for the power system shown in Fig. Q10 (b) using ZBus 8
building algorithm. Select ground node as reference. The line reactances are
in pu.

Dr. R V Parimala
Prof. &HoD, Dept. of EEE
BNMIT, Bengaluru