0 ratings0% found this document useful (0 votes) 208 views20 pagesEnsoniq DP4 Sysex Spec Part2
Ensoniq DP4 Sysex - Part 2
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content,
claim it here.
Available Formats
Download as PDF or read online on Scribd
DP/4 MIDI SysEx Specification
——
‘Name Number Offset Type
00 — Small Room Rev, Large Room Rey, Hall Reverb
Algorithm index codes 01,02,03 : 20 unique pdefs : 30 total params
ao 33
Volume a2 32
‘Room/tiall Decay 03 (OL
‘Room/Hall Predelay Time 4 10
‘Room/Hall LF DecayTime 05 (02
Room/Hall HF Damping 06 = 03
Room/Hall HF Bandwidth 7 4
Room/Hall Diffusion) 080s
‘Room/Hall Diffusion? 09 06
Room/Hall Decay Definition 10-07
Room/Hall Detune Rate 1 08
Room/Hall Detune Depth rn 9
Room/Hall Primary Send 199 12
Room/Hall Ref 1 Time 4
Room/all Ref 1 Level sa)
Room/Hall Ref 1 Send 16 15
Room/Hall Ref 2 Time 7 16
‘Room/Hall Ref 2 Level 1 20
Room/Fiall Ret 2 Send 9 1B
Position Balance (1) 20 2
Position Balance (2) Bis Wie
Position Balance (3) nm 2
‘Modi Source 3 OM
‘Modl Destination Parameter 24-25
Modi Param Range Min 25 (6
Modi Param Range Max 2 «27
Mod? Source 27 8B
Mod? Destination Parameter = «28-29
Mod? Param Range Min 2930
Mod? Param Range Max 300031
00 — Small Plate, Large Plate
Algorithm index codes 05,06 : 12 unique pdefs
Mix oa | 33
Volume 0232
‘Small/Large Plate Decay 03 OL
Plate Predelay Time 0407
SmallLarge Plate HF Damping 05 02
Small/Large Plate HF Bandwidth 06 03
Plate Diffusion 1 07 Os
Plate Diffusion 2 08 Os
Plate Decay Definition 0906
Early Ref Level 1 10 0
Early Ref Level 2 n 0
Early Ref Level 3 2
Early Ref Level 4 Be
LefyRight Balance 4 2B
Mod! Source 15
Mod Destination Parameter 16 25
‘Modi Param Range Min 7 26
Modl Param Range Max
18
27
Pos Frac
Pos Frac
Table
Word
Signed Frac
Pos Frac
Pos Frac
Pos Int
Pos Int
os Frac
os Int
os Frac
Signed Frac
Werd
Pos Frac
Pos Frac
Word
Pos Frac
os Frac
Signed Frac
Signed Frac
Signed Frac
Table
Pos Int
Pos Frac
Pos Frac
Table
Pos Int
Pos Frac
Pos Frac
+22 total params
Pos Int
Pos Int
Table
Word
Pos Frac
Pos Frac
Pos Int
Pos Int
Pos Frac
Signed Frac
Signed Frac
Signed Frac
Signed Frac
Signed Frac
Table
Pos Int
Pos Frac
Pos Frac
Internal
0.99
0,127
128,127
0,120
0,127
0,127
0,120
0,127
0,127
128,127
“128,127
-128,127
08
0,127
0.127
0,127
08
0.127
0,127
0,127
0,127
0.127
0,127
0,430
0,127
24127
0.99
0.99
0,127
128,127
-128,127
128,127
128,127
128,127
08
0,127
0,127
04127
Displayed
0.99
0.99
Field size: 4
0,450
99.99
0,99
1,99.
0,99
0,99
0.99
0,99
0,99
99,99
0,120
0,99
0,99
0,120
0.99
0.99
99.99
99.99
99.99
Off, Controller 1.8
0,99
0,99
0,99
Off, Controller 1.8
0.99
0,99
0,99
0,99
0,99
Field size: 4
0,430
0,99
1,99
099
0.99
0.99
99,99
"99.99
99.99
99.99
-99.99
Off,Controller 1.8
0,99
0,99
0.99
ee
Appendix A - 21DP/4 MIDI SysEx Specification
‘Name ‘Number Offset Type ‘Internal Displayed
‘Mod Source 19-28 Table 08 ‘Off Controller 1.8
Mod2 Destination Parameter 20,229 Pos Int 0.127 0,99
‘Mod? Param Range Min 2130 Pos Frac 0127 0.99
‘Mod? Param Range Max 22031 Pos Frac 0127 0.99
00 — Reverse Reverb
Algorithm index code 08 : 10 unique pdefs : 20 total params.
Mix 0133 Pos Int 0,127 0,99
Volume 02-32 Pos Int 0,127 0,99
Reverse Envelope HoldTime 03.—= OL Table 0,62 Field size: 5
Reverse Attack 04 = 02 Table. 0,62 Field size: 5
Reverse Release 05 03 Table 0,62 Field size: 5
Reverse Trigger Threshold 06 © O4-—Signed Int —-96,0 96,0
Reverse HF Damping 07 05s Frac 0,127 0,99
Rev Diffusion 1 08 = -06-——Pos Int 0.99 0,99
Rey Diffusion 2 09 © -07_—~Pos Int 0.99 0,99
Reverse Decay Definition 10 08 Pos Frac 0,127 0.99
‘Reverse Slapback 109 Word 0,530 0,530
‘Reverse Slapback Level 12 Pos Frac 0.127 0,99
Mod] Source 13 24 Table 08 Off, Controller 1.8
Modi Destination Parameter «14.25. —Pos Int 0,127 0,99
Mol Param Range Min 1526 PosFrac 0,127 0.99
‘Modi Param Range Max 1627 Pos Frac 0,127 0,99
Moa2 Source 17 28 Table 08 OfF,Controller 1.8,
‘Mod2 Destination Parameter = 18. -29—Pos Int 0,127 0,99
‘Mod? Param Range Min 1930 Pos Frac 0,127 0.99
Mod2 Param Range Max 20° 31 Pos Frac 0,127 0.99
00 — Reverse Reverb 2
Algorithm index code 54 : 09 unique pdefs : 19 total params
Mix Ol 33 Pos Int 0327 0,99
Volume 02 32 Pos It 04127 099
Reverse Envelope HoldTime —03-—=«O_— Table 062 Field size: 5
Reverse Altack 0 = a2 Table 062 Field size: 5
Reverse Release 05 «03 Table 062 Field size: 5
Reverse Trigger Threshold 06 «04 Signed int 96,0 960
Pre-Trigger Memory 07 12 Wad 0,530 0530
Reverse HF Damping 08 © 05 Pos Frac 0,27 099
Rev Diffusion 1 09 = 06 Pos Int 099 099
Rev Diffusion 2 1007 Pos Int 099 0,99
Reverse Decay Definition M08 Pos Fre 0,27 099
Modil Source 2 2% Table 08 Off, Controller 1.8
Mod1 Destination Parameter «13. -25-——Pos Int 04127 0,99
Mod! Param Range Min 14-26 Pos Frac 0127 099
Modi Param Range Max 1S 27 Pos Frac 04127 0,99
Mos Source 16-28 Table 08 Off,Controlter 1.8
‘Mod2 Destination Parameter = «17, 29—Pos Int 04127 099)
Mod2 Param Range Min 18 30 Pos Frac 0,127 099
Mod? Param Range Max 1931 Pos Frac 0,127 099
as
Appendix A - 22DP/4 MIDI SysEx Specification
——
‘Name ‘Number Offset Type “Internal Displayed
00 — Gated Reverb
Algorithm index code 07 : 17 unique pdefs: 27 total params
Mix 0133 Pos Int 0127 099
Volume 02 © 32——Pos Int 04127 099
Gate Attack 03 «Ol Table 062 Field size: 5
Hold Time 04 (02 Table 0,62, Feld size: 5
Gate Decay 0503 Table 04127 Field size: 4
Release Time 056 (04 Table 0.62 Field size: 5
Gate Trigger Threshold OT 05 Signedint_—— 96,0 960
Gated Retigger Threshold 08 —06-—Signed Int, -960 96,0
Gated HF Damping 09 07 Pos Frac 0,127 099
Gated Diffusion 1 10 08 Pos int 099 099
Gated Diffusion 2 M9 Pos Int 099 099
Gated Decay Definition 12 10 Pos Frac 0,127 099
Gated Slapback Boo Wat 0,500 0.500
Gated Stapback Level 14 13 PosFrac 0427 099
Early Refs (1) 1514 Signed Frc -128,127 999
Early Refs (2) 16 15 Signed Frc -128,127 99.99
Early Refs G3) 1716 Signed Frac -128,127 99.99
Early Refs (4) 18 17 — Signed Frac -128,127 99.99
‘LelRight Balance 19 23 Signed Frac -128,127 99.99
Mod Source 20 24 = Table 08 Off,Controller 1.8
Mod1 Destination Parameter. = 21-25. Pos Int 027 099)
Mod! Param Range Min 22 © 26 Pos Frac 04127 099
‘Mod1 Param Range Max 23027 PosFrac 04127 099
Mod2 Source 2% «28 Table og Off,Controller 1.8
Mod? Destination Parameter 25 29—Pos Int 0,127 099
‘Mod? Param Range Min 26 30 —PosFrac 0,127 099
Mod2 Param Range Max 2731 Pos Frac 0327 099
00 — Non Lin Reverb 1, 2, 3
Algorithm index codes 04,46,59 : 21 unique pdefs : 31 total params
Mix 1 33.—-Pos Int 04127 099
Volume 02-32 Pos Int 0.127 099
Envelope Level 1 0301 Pos Frac 0,127 099
Envelope Level 2 04 = 02—Pos Frac 0,127 099
Envelope Level 3 05 03—Pos Frac 0,127 099
Envelope Level 4 06 04 Pos Frac 04127 099
Envelope Level 5 07 © 05—Pos Frac 0127 099
Envelope Level 6 08 = 05 Pos Frac 0.127 099
Envelope Level 7 0907 Pos Frac 04127 099
Envelope Level 8 10 08 Pos Frac 0.127 0.99
Envelope Level 9 M09 Pos Frac 0.127 0:99
NonLin HF Damping 12 10 Pos Frac 04127 099
Nonlin HF Bandwidth 13° IL Pos Frac 2127 199)
Nonlin Diffusion 1412 Pos Int 0.99 099
NonLin Diffusion? 1S 13 os Int 099 099
NonLin Density 1 16 14s Int 099 099
NonLin Density 2 1715 Pos Int 099 099
Nonlin Primary Send 18 16 Signed Frac -128,127 99,99
Reflection 1 Time 1917 Word 0,600 0,600
Reflection I Send 2019 Signed Frac -128,127 99.99
Reflection 2 Time 210-200 Word 0,600 0,600
Reflection 2 Send 22 © 22 ~— Signed Frac -128,127 99.99
——
Appendix A - 23