0% found this document useful (1 vote)
433 views24 pages

Aashto M 170m-08

For testing RC pipe

Uploaded by

phanna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (1 vote)
433 views24 pages

Aashto M 170m-08

For testing RC pipe

Uploaded by

phanna
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 24
‘Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe [Metric] Designation: M170M-08" ASTM Designation: C 76M-07 1. SCOPE 1 ‘This specification covers reinforce concrete pie intended to be use fr the conveyance of sewage, industria wastes, and storm water, and for the construction of culverts. 12. ‘This specification is the metric counterpart of M 170. Note 1—This specification is a manufacturing and purchase specification only, and does not ‘include requirements for bedding, backfill, or the relationship between field load condition and the strength classification of pipe, However, experience has shown thatthe successful performance of this product depends upon the proper selection ofthe clas of pipe, type of bedding and backfill, contolled manufacture in the plant, and care that installation conforms ta the cansiniction| specifications. The owner ofthe reinforced concrete pipe specified herein is cautioned that he ‘must correlate the field requirements with the class of pipe specified and provide inspection atthe construction site. Note 2—Attention is called tothe specification for reinforced concrete D-load culvert, storm drain, and sewer pipe (M 242M/M 242), REFERENCED DOCUMENTS: 2A AASHTO Standards: M6, Fine Aggregate for Hydraulic Cement Concrete ‘M 31MM 31, Deformed and Plain Carbon Steel Bars for Concrete Reinforcement M32M/M 32, Stee! Wire, Plain, for Concrete Reinforcement (MSSM/M 55, Stec] Welded Wire Reinforcement, Plain, for Concrete 1M 80, Coarse Aggregate for Hydraulic Cement Concrete M85, Portland Cement M S6M/M 86, Concrete Sewer, Storm Drain, and Culvert Pipe (Metric] M148, Liquid Membrane-Forming Compounds for Curing Concrete 1M 154 Air-Entraining Admixtures for Conerete M170, Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe M 194M/M194 Chemical Admixtures for Concrete M 221MM 221, Stee! Welded Wire Reinforcement, Deformed, for Concrete 1M 225M/M 225, Steel Wiee, Deformed, for Concrete Reinforcement ‘M240, Blended Hydraulic Cement M 242MM 242, Reinforced Concrete D-Load Culvert, Storm Drain, and Sewer Pipe [Metric] ‘TS4a M170M-1 ‘AASHTO. M262, Conerete Pipe and Related Products M295, Coal Fly Ash and Raw or Caleined Natural Pozzolan for Use in Concrete M302, Ground Granulated Blast Furnace Slag for Use in Concrete and Mortars ‘mT 280, Concrete Pipe, Manhole Sections, or Tile 22 ASTM Standards: = A36{A 36M Specification for Carbon Structural Stel 1 A 706/A706M Specification for Low-Alloy Steel Deformed and Plan Bars for Concrete ‘Retiiforcement ~ C1017, Specification for Chemical Admixtues for se in Producing Flowing Concrete C1116, Specification for Fiber-Reinforced Conerete and Shoterete 3 TERMINOLOGY 3a Definitions —For definitions of terms relating to concrete pipe, see M 262. 4 CLASSIFICATION 4a. Pipe manufactured in aordance with this specification shall be of Five classes identified as Class I, Class Il, Class Ill, Class TV, and Class V. The corresponding strength requirements are preseribed in Tables 1 to 5. TS-4a M 170M-2 ‘AASHTO jususaioyiiny 38) aE crore eo Es) ondyg 9m —_DUU_ssauyOHL, ronda 32M sOUU —jeuaaiagisy EAN RuagOEE spinal, apjnoni, WAIN Le “WHBUINS 2131910], avi 912 “wus ‘aie vara Tien Sig jo w aU] HO TSUIBRIONTONL — “aig aiaioao3 poaioyuray | SSeIQ 20} swuauouinboy} ISG —p @I4eL, OD, ‘AASHTO M170M-3 TS-4a

You might also like