Material Test Format

The document contains test reports for moisture content of sand, silt content of fine aggregate, sieve analysis of fine aggregate, and sieve analysis of coarse aggregate. The test reports include project details, sample information, test procedures, results, and sign-offs from the contractor and client.

Uploaded by

मधु
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
3K views6 pages

Material Test Format

The document contains test reports for moisture content of sand, silt content of fine aggregate, sieve analysis of fine aggregate, and sieve analysis of coarse aggregate. The test reports include project details, sample information, test procedures, results, and sign-offs from the contractor and client.

Uploaded by

मधु
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 6

TEST REPORT FOR MOISTURE CONTENT OF SAND

Project name : Tested for :


Moisture content
Lab Reference :
Date of sampling: Date of test :

Test No. 1 2 3 4 5

Container No.

Wt. Of wet sand taken (Sw)

Wt. Of dry sand in pan (Sd)

Wt. Of water (W=Sw-Sd)

Moisture content
= 100* W/Sd

Remarks:

Test result: OK / NOT OK


Checked by: CONTRACTOR CLIENT
Name:
Signature:
TEST REPORT FOR SILT CONTENT OF FINE AGGREGATE

Project name :
Tested for : silt content
Source :
Lab Reference : Store entry no:
Date of sampling: Date of test :

Sl. No. Descriptions Trail No. Remarks

1 Volume of the sand


(v1)
2 Volume of silt (v2)

3 Silt content in %.
V2/V1 X 100

Comments if any
Checked by: CONTRACTOR CLIENT
Name:
Signature:
TEST REPORT FOR SIEVE ANALYSIS OF FINE AGGREGATE

Project name :
Tested for : Sieve analysis
Source :
Lab Reference : Store entry no:
Date of sampling: Date of test :
Technical ref. : IS 383 – 1970 (RA-2002)

Sieve Wt. Cum.wt. Cum. % Cum. % Percentage passing As per


retained retained wt. passing IS 383 for
retained Zone 1 Zone 2 Zone 3 Zone 4
10mm 100 100 100 100

4.75 90-100 90-100 90-100 95-100


mm
2.36 60-95 75-100 85-100 95-100
mm
1.18 30-70 55-90 75-100 90-100
mm
600 15-34 35-59 60-79 80-100
microns
300 5-20 8-30 12-40 15-50
microns
150 0-10 0-10 0-10 0-15
microns
Pan

Remarks:

Test result: OK / NOT OK


Checked by: CONTRACTOR CLIENT
Name:
Signature:
TEST REPORT FOR SIEVE ANALYSIS OF COARSE AGGREGATE,

Project name : Tested for :


Sieve analysis,
Lab Reference: Store entry :
Date of sampling: Date of test:
Technical ref. : IS 383 – 1970 (RA-2002), IS 2386 – 1970 (RA.2002)

Sieve Wt. Cumu wt. Cumu. Cumu. % Requirement Requirement


no. retained retained % wt. passing 12.5mm 20mm
retained Graded Single Graded Single
size size
------ ------ 100 100
40mm

100 100 95-100 85-100


20mm

90-100 85-100 ------ -------


12.5mm

40-85 0- 45 25-55 0-20


10mm

0-10 0-10 0-10 0-5


4.75mm

Pan
Remarks:

Test result: OK / NOT OK


Checked by: CONTRACTOR CLIENT
Name:
Signature:
TEST REPORT FOR BRICKS
Project name : Tested for : Compressive
strength
& water absorption
Lab Reference: ` Store entry :
Date of sampling:
Date of test:
Technical ref. :
1. Physical Properties

Dimensional Conformance
Sounding
Colour
Obliqueness
Remarks
2. Compressive strength

Sl. C/S Area Maximum Compressive Requirement Remarks


No. (mm2) Load (N) Strength as per
LXB N per mm2 specification
1
2
3

3. Water absorption

Sl. Wt. of oven Wt. of wet % of water Requirement Remarks


No. dried brick brick (kg) absorption
(kg)
1 not more than
2 20% by mass
3

Test result: OK / NOT OK


Checked by: CONTRACTOR CLIENT
Name:
Signature: