0% found this document useful (0 votes)
477 views

Anode Calculation - Caisson

This document summarizes the design parameters for cathodic protection of an offshore structure. It details the structure dimensions, area to be protected, criteria for protection, and calculations for anode requirements. The structure has a diameter of 1985mm and height of 9m above the sea floor. Design calls for sacrificial aluminum alloy anodes to provide 25 years of protection. Calculations determine the current requirement is 5.9887 amps, requiring 6 anodes weighing a total of 305.035457 kgs.

Uploaded by

Indah Rachmadita
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
477 views

Anode Calculation - Caisson

This document summarizes the design parameters for cathodic protection of an offshore structure. It details the structure dimensions, area to be protected, criteria for protection, and calculations for anode requirements. The structure has a diameter of 1985mm and height of 9m above the sea floor. Design calls for sacrificial aluminum alloy anodes to provide 25 years of protection. Calculations determine the current requirement is 5.9887 amps, requiring 6 anodes weighing a total of 305.035457 kgs.

Uploaded by

Indah Rachmadita
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6

1 Description Equipment

OD = 1985 mm 1.985 m
H= 9000 mm 9m
Splash zone Area [3.5 m to -1.00m] 46.14 m2
Elevation between [-1.00 m -to -4.50 m] 34.51 m2

2 Design Parameter
2.1 Cathodic protection criteria : -1.05 volt vs Ag/AgCl
2.2 Type of CP : Sacrificial anode
2.3 Design life time (L) : 25 years
2.4 Calculation allowance (SF) : 10%
2.5 Resistivity Sea Water (r) : 20 ohm.cm

2.6 Current Density (i) :


Sea Water : Initial : 0.150 A/m2 * Refer to DNV RP B401 (2005) Tabel 10-1 and T
Mean : 0.070 A/m2
Final : 0.100 A/m2
2.7 Estimate Coating Breakdown (fc)
Depth 3.5 to -1m -1 to -4.5 m
Initial : 5% 100%
Mean : 30% 100%
Final : 55% 100%
2.8 Sacrificial Anode Material : Alumunium Alloy (Al-ln-Zn) Anode
2.9 Aluminium Anode Data
Element Content (%)
Zinc (Zn) 3.0 - 5.0
Indium (In) 0.01 - 0.02
Silicon (Si) 0.5 max
Iron (Fe) 0.12 max
Size : 900 (L) x 150 (W) x 150 mm (T) A= 135000 mm2
Weight (Wa) : 53.7 kgs (nett) 0.135 m2

CALCULATION
1 Area to be protected
Splash zone Area [3.5 m to -1.00m] 46.14 m2
Elevation between [-1.00 m -to -4.50 m] 34.51 m2

2 Current Requirement
Ic = Ac x ic x fc (Amp)
3.5 to -1m -1 to -4.5 m Total
Initial 0.34605 5.1765 5.52255
Mean 0.96894 2.4157 3.38464
Final 2.5377 3.451 5.9887
3 Weight of anode
*mean condition
W= Ic x L x 8760 305.035457 kgs * u and c refer to DNV RP B401 (2005) tabel 10-
uxc
4 Number of Anode (By Weight Calculation)
N= W/Wa 5.680362324 → 6 Anodes Anode Utilization Factor (u

Anode current capacity/ El


401 (2005) Tabel 10-1 and Tabel 10-2
NV RP B401 (2005) tabel 10-8 and 10-6

Anode Utilization Factor (u)

Anode current capacity/ Electrochemical Capacity (e)