Integrated Control System NETWORK SOLUTIONS

for Seamless Connection


between VRV ® and BMS
Systems

w w w. d a i k i n . e u
BACnet Interface
Main features
1. Bacnet Interface 2. Open Network Integration

>> Precise and efficient monitoring and control of VRV® >> The Daikin BACnet adapter requires no additional
and HRV systems. Also Split and Sky Air units can interfaces for connection to BACnet networks
be connected via an optional interface adapter equipment and building control systems. BACnet
>> Flexible, multi purpose system networks are recognised worldwide as the standard
>> Control mechanism is BACnet within the building controls industry. BACnet
>> Provides easy integration into building manage- data communication protocol makes it possible
ment systems (BMS) including management of all to control access, energy management, fire /
building installations in remote control or interlocked life / safety, HVAC and lighting etc.
control.

BMS DMS502A51

DIII- NET

DAM602B51 / 52 Local Control


(Intelligent Manager)
non-standard BACnet
Interface required VRV®
Outdoor unit
BACNET / ETHERNET

HRV

Remote Control
DAIKIN A / C INFRASTRUCTURE

BUILDING
CONTROL Fire alarm Security Power supply facility Pump Lighting Elevator
NETWORK

2
3. Quick and Easy Installation 7. Functions

>> The open protocol specification gives local system Monitoring


integrators complete design freedom. Moreover,
>> Air conditioning status monitoring: 128 groups of
the ability to combine individual items of equipment
indoor units and 20 outdoor systems.
into BACnet networks reduces the time and costs
(Max 256 groups of indoor units and 40 outdoor
required for wiring work.
systems, when optional DIII board is added)1
>> Indoor unit error monitoring
4. Unlimited Site Size >> Indoor (air inlet) temperature monitoring
>> Filter sign monitoring
>> The network adapter can be connected to 128 >> Thermostat status
groups (256 with optional accessory). Maximum >> Compressor operation status
value of BACnet Interface is set by BACnet BMS. >> Indoor fan operation
>> Heater operation
5. Rohs Compliance >> Air direction monitoring
>> Air flow rate monitoring
>> Restriction of Hazardous Substances in electrical and >> Forced thermostat off / on monitoring
electronic equipment (2002 / 95 / EC). >> Alarm sign
>> Hazardous substances include Lead (Pb), Cadmium >> PPD data2
(Cd), Hexavalent Chromium (Cr6+), Mercury (Hg), The transmission of VRV® PPD
Polybrominated biphenyls (PBB), Polybrominated (power proportional distribution) data is possible
diphenylether (PBDE). by BACnet communication for BMS system.
>> Although RoHS regulations are only applicable to
small and large household equipment, Daikin’s Control, operation and settings
environmental policy nevertheless ensures that
VRV®III will be totally in line with RoHS. >> Start / stop control
>> Temperature adjustment mode setting
6. Specifications of Communication >> Remote control setting
>> Temperature setting
Objects >> Filter sign reset
>> Indoor unit mode setting
>> Analog input
>> Air direction setting
>> Analog value
>> Air flow rate setting
>> Binary input
>> Forced thermostat off / on setting
>> Binary output
>> Energy efficiency command
>> Binary value
(setting temperature shift)
>> Multistate input
>> Forced OFF setting
>> Multistate output
>> Subgroup adress control operation rejection
Functionality >> Gateway LED display for operation and malfunction
detection
>> Monitoring
>> Commanding 1 Optional DIII board (DAM411B51)
>> Alarming 2 Optional Di board (DAM412B51) is required

Datalink

>> Ethernet (IEEE802.3)


>> BACnet / IP

3
8. Compatibility with Leading bms systems, a.o.:

manufacturer type manufacturer type


Andover Controls - Continuum ver. 1.6 1.6 Siemens - System 600 Apogee Insight V3.2
Cimetrics Sauter - OPC Server Siemens - System 600 Apogee Insight V3.4
Honeywell - EBI V2.0 Siemens - Desigo Insight V1.01
Iconix Sauter - OPC Server Siemens - PX Desigo Insight V2.2
Invensys (Sacthwell) Polar Soft - System Manager TAC Pacific - OPC Server
- BACdoor Trane - Tracer Summit
Johnson Controls - Metasys BSI V9.01c Trend
Johnson Controls - Metasys N30 Tridium - Niagara Framework 2.301.321.v1
Priva Trilogy
Reliable Systems - Mach

Compatibility can be checked with a Joint Matching Test before installation.


For more information contact your sales representative.

SPECIFICATIONS
item description

BACnet Interface DMS502A51 Up to 128 groups


BACnet transmission ASHRAE135 (IEEE802.3)
BACnet / IP
Conformance class3
Power supply 1~ AC, 100 to 240V, ± 10% at 50 / 60Hz
Power consumption 20W max.
Dimensions (H x W x D) mm 263x275x81.5
Weight kg ±3
Ambient condition -10°C to 50°C within humidity range between 0% and 98% (no condensation)
Insulation resistance At least 50M at 500VDC

ACCESSORIES
item description
DIII board DAM411B51 Extension of 2 x DIII lines (2 x 64) indoor groups
Optional Di board DAM412B51 In case of PPD to provide up to 12 pulse input points
KRP928B2S For connection to Split units
Interface adapters DTA102A52 For connection to R-22 / R-407C Sky Air units
DTA112B51 For connection to R-410A Sky Air units

Daikin’s unique position as a manufacturer of Daikin Europe N.V. is approved by LRQA for its Quality The present leaflet is drawn up by way of information only and
air conditioning equipment, compressors and Management System in accordance with the ISO9001 does not constitute an offer binding upon Daikin Europe N.V.. Daikin
refrigerants has led to its close involvement in standard. ISO9001 pertains to quality assurance re- Europe N.V. has compiled the content of this leaflet to the best
environmental issues. garding design, development, manufacturing as well of its knowledge. No express or implied warranty is given for the
For several years Daikin has had the intention as to services related to the product. completeness, accuracy, reliability or fitness for particular purpose
to become a leader in the provision of products of its content and the products and services presented therein.
that have limited impact on the environment. Specifications are subject to change without prior notice. Daikin
This challenge demands the eco design and Europe N.V. explicitly rejects any liability for any direct or indirect
development of a wide range of products and ISO14001 assures an effective environmental man- damage, in the broadest sense, arising from or related to the use Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende
an energy management system, resulting in agement system in order to help protect human and/or interpretation of this leaflet. All content is copyrighted by
energy conservation and a reduction of waste. health and the environment from the potential impact Daikin Europe N.V.
of our activities, products and services and to assist
in maintaining and improving the quality of the en-
Printed on non-chlorinated paper. Prepared by La Movida, Belgium

vironment.

Daikin units comply with the European regulations


that guarantee the safety of the product.
ECPEN09-304 • XXX • 02/09 • Copyright © Daikin

Daikin products are distributed by:


The present publication supersedes EPL08-304.

VRV® products are not within the scope of the


Eurovent certification programme.

Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu FSC
BTW: BE 0412 120 336
RPR Oostende

You might also like