0% found this document useful (0 votes)
74 views2 pages

Dimensions: S60-PA-5 S60-PA-2

This document provides information about a polarized retroreflective sensor with red emission including: 1. It detects objects when they interrupt the light beam between the sensor and its associated prismatic reflector. 2. It allows reliable detection of very reflective objects like mirrors by using high-polarization optic filters. 3. It provides indicators for output status and stability and has an adjustment trimmer to increase the operating distance.

Uploaded by

sai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
74 views2 pages

Dimensions: S60-PA-5 S60-PA-2

This document provides information about a polarized retroreflective sensor with red emission including: 1. It detects objects when they interrupt the light beam between the sensor and its associated prismatic reflector. 2. It allows reliable detection of very reflective objects like mirrors by using high-polarization optic filters. 3. It provides indicators for output status and stability and has an adjustment trimmer to increase the operating distance.

Uploaded by

sai
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

B POLARISED RETROREFLEX WITH RED EMISSION

With retroreflex sensors the object


DIMENSIONS
is detected when it interrupts the
light beam generated between the
sensor and its associated prismatic
reflector. High-polarisation optic
filters also allow reliable detection A
of very reflective objects, such as
mirrored surfaces that, differently
from the prismatic reflector, reflect
the light beam without rotating the
polarisation plane.

Output status and


INDICATORS AND SETTINGS A
stability LEDs

B B Adjustment trimmer

C M12 connector output


A

D Cable output

Single-turn trimmer for sensitivity adjustment.


Rotate clockwise to increase the operating distance.

ACCESSORIES CONNECTIONS

For dedicated accessories refer to the


ACCESSORIES section of this catalogue.

Refer also to Reflectors (A.01), Connectors


S60-PA-2 S60-PA-5
(A.03) and Fixing Brackets (A.04) of the
General Catalogue

BROWN
Vdc NC OUTPUT + 10 ... 30 Vdc
WHITE (WHITE) (BROWN)
NC OUTPUT
BLACK 0V - NO OUTPUT
NO OUTPUT (BLUE) (BLACK)
BLUE

6
83 m
TECHNICAL DATA SELECTION TABLE
axial optics - 2 m cable

S60-PA-2-B01-NN

S60-PA-5-B01-NN
S60-PA-2-B01-PP

S60-PA-5-B01-PP
S60-PA-2-B01-NN 956201460 NPN
S60-PA-2-B01-PP 956201300 PNP

axial optics - M12 connector


S60-PA-5-B01-NN 956201180 NPN
S60-PA-5-B01-PP 956201040 PNP
Operating distance: 0.1 ... 8 m (on R5)
Power supply: 10 ... 30 Vdc 1 All the ordering codes and information are
Ripple: ≤ 2 Vpp summarised in the last pages of this catalogue
Consumption: ≤ 40 mA
Light emission: red LED 660 nm 2
Spot dimension: aprox. 90 mm at 3 m
Setting: sensitivity trimmer 3
Indicators:
yellow OUTPUT LED
green STABILITY LED
Output type:
PNP, NO and NC
NPN, NO and NC
Output current: ≤ 100 mA
Saturation voltage: ≤2V
Response time: 500 µs
Switching frequency: 1 kHz
Operating mode: dark on NO / light on NC
Connection:
2 m Ø 4 mm cable 4
M12 4-pole connector 5 TECHNICAL NOTES
Electrical protection: class 2 1 Limit values
Mechanical protection: IP67
2 Average life of 100.000 h with TA = +25 °C
Protection devices: A, B 6
Housing material: ABS 3 270° trimmer
Lens material: window in PMMA 7 4 PVC, 4 x 0.14 mm2
Weight: 5 Connector can be blocked on two positions
90 g max.
6 A - reverse polarity protection
40 g max.
Operating temperature: -25 ... +55°C B - overload and short-circuit protection on
Storage temperature: -25 ... +70°C outputs
Reference standard: EN 60947-5-2 7 Internal lenses in Polycarbonate

DETECTION DIAGRAMS

R5 7 8

R2 6 6,5
R5
R2
0 2 4 6 8 10 (m) R5

Recommended operating distance


Maximum operating distance R2

High efficiency reflectors can be used


to obtain larger operating distances.
Refer to Reflectors (A.01) of the
General Catalogue

Excess gain Detection area