SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
SECTION 1. IDENTIFICATION
Product name : Calibrator for automated systems
Product code : 10759350360
Manufacturer or supplier's details
Company name of supplier : Roche Diagnostics
-
Address : 9115 Hague Road
46250 Indianapolis IN
USA
Telephone : 1-800-428-5074
Emergency telephone
In case of emergencies: : CHEMTREC 1-800-424-9300 (U.S. or Ca-
nada)
1-703-527-3887 (Internatio-
nal)
Recommended use of the chemical and restrictions on use
Restrictions on use : For professional users only.
SECTION 2. HAZARDS IDENTIFICATION
GHS classification in accordance with 29 CFR 1910.1200
The product is a kit consisting of individual ingredients. The classification of the ingredients can
be obtained from section 3. Section Label elements contains the resulting labelling for the kit
GHS label elements
Not a hazardous substance or mixture.
Other hazards
None known.
SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS
Cfas USA F1-oSw
GHS Classification
Not a hazardous substance or mixture.
Chemical nature : Handle as potentially infectious.
Hazardous ingredients
Chemical name CAS-No. Concentration (% w/w)
1,3-Propanediol, 2,2-bis(hydroxymethyl)- 115-77-5 >= 10 - < 20
Methanaminium, N,N,N-trimethyl-, chloride 75-57-0 >= 0.1 - < 1
(1:1)
1 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
SECTION 4. FIRST AID MEASURES
General advice : Do not leave the victim unattended.
If inhaled : Move to fresh air.
If unconscious, place in recovery position and seek medical
advice.
If symptoms persist, call a physician.
In case of skin contact : If on skin, rinse well with water.
In case of eye contact : Immediately flush eye(s) with plenty of water.
Remove contact lenses.
Protect unharmed eye.
If eye irritation persists, consult a specialist.
If swallowed : Keep respiratory tract clear.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.
If symptoms persist, call a physician.
Rinse mouth with water.
Most important symptoms : No information available.
and effects, both acute and
delayed
Notes to physician : The first aid procedure should be established in consultation
with the doctor responsible for industrial medicine.
SECTION 5. FIRE-FIGHTING MEASURES
Suitable extinguishing media : Use extinguishing measures that are appropriate to local cir-
cumstances and the surrounding environment.
Specific hazards during fire : No information available.
fighting
Further information : Standard procedure for chemical fires.
Use extinguishing measures that are appropriate to local cir-
cumstances and the surrounding environment.
Special protective equipment : Wear self-contained breathing apparatus for firefighting if
for fire-fighters necessary.
SECTION 6. ACCIDENTAL RELEASE MEASURES
Personal precautions, protec- : Avoid dust formation.
tive equipment and emer-
gency procedures
Environmental precautions : Local authorities should be advised if significant spillages
cannot be contained.
2 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
Methods and materials for : Pick up and arrange disposal without creating dust.
containment and cleaning up Sweep up and shovel.
Keep in suitable, closed containers for disposal.
SECTION 7. HANDLING AND STORAGE
Advice on protection against : Provide appropriate exhaust ventilation at places where dust
fire and explosion is formed.
Advice on safe handling : For personal protection see section 8.
Smoking, eating and drinking should be prohibited in the ap-
plication area.
Conditions for safe storage : Electrical installations / working materials must comply with
the technological safety standards.
Technical : See label, package insert or internal guidelines
measures/Precautions
Materials to avoid : No materials to be especially mentioned.
Further information on stor- : No decomposition if stored and applied as directed.
age stability
SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Cfas USA F1-oSw
Ingredients with workplace control parameters
Ingredients CAS-No. Value type Control parame- Basis
(Form of ters / Permissible
exposure) concentration
1,3-Propanediol, 2,2- 115-77-5 TWA 10 mg/m3 ACGIH
bis(hydroxymethyl)-
TWA (Res- 5 mg/m3 NIOSH REL
pirable)
TWA (total) 10 mg/m3 NIOSH REL
TWA (total 15 mg/m3 OSHA Z-1
dust)
TWA (respir- 5 mg/m3 OSHA Z-1
able fraction)
TWA (Total 10 mg/m3 OSHA P0
dust)
TWA (respir- 5 mg/m3 OSHA P0
able dust
fraction)
Engineering measures : No data available
Personal protective equipment
Respiratory protection : No personal respiratory protective equipment normally requi-
red.
3 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
Hand protection
Material : Protective gloves
Remarks : Wear appropriate protective gloves to prevent skin contact.
Replace torn or punctured gloves promptly.
Eye protection : Safety glasses
Skin and body protection : Protective suit
Hygiene measures : Handle in accordance with good industrial hygiene and safety
practice.
SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES
Cfas USA F1-oSw
Appearance : solid, (lyophilized)
Color : light yellow
Odor : characteristic
Odor Threshold : Not applicable
pH : 6.9
Concentration: 100 g/l
(as aqueous solution)
Melting point/range : No data available
Boiling point/boiling range : No data available
Flash point : does not flash
Evaporation rate : No data available
Flammability (solid, gas) : Sustains combustion
Flammability (liquids) : Sustains combustion
Self-ignition : No data available
Upper explosion limit / Upper : No data available
flammability limit
Lower explosion limit / Lower : No data available
flammability limit
Vapor pressure : No data available
Relative vapor density : Not applicable
4 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
Relative density : No data available
Solubility(ies)
Water solubility : soluble
Solubility in other solvents : No data available
Partition coefficient: n- : No data available
octanol/water
Autoignition temperature : No data available
Decomposition temperature : No data available
Viscosity
Viscosity, dynamic : Not applicable
Viscosity, kinematic : Not applicable
Oxidizing properties : The substance or mixture is not classified as oxidizing.
SECTION 10. STABILITY AND REACTIVITY
Reactivity : No dangerous reaction known under conditions of normal use.
Chemical stability : Stable under normal conditions.
Possibility of hazardous reac- : Stable under recommended storage conditions.
tions No hazards to be specially mentioned.
Conditions to avoid : No data available
Incompatible materials : No data available
Hazardous decomposition : No data available
products
SECTION 11. TOXICOLOGICAL INFORMATION
Cfas USA F1-oSw
Acute toxicity
Not classified based on available information.
Ingredients:
1,3-Propanediol, 2,2-bis(hydroxymethyl)-:
Acute oral toxicity : LD50 Oral (Mouse): 25,500 mg/kg
LD50 Oral (Rat): > 5,100 mg/kg
Method: OECD Test Guideline 401
5 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
Acute inhalation toxicity : LC0 (Rat): 11 mg/l
Exposure time: 6 h
Test atmosphere: dust/mist
Acute dermal toxicity : LD50 (Rabbit): > 10,000 mg/kg
Method: OECD Test Guideline 402
Methanaminium, N,N,N-trimethyl-, chloride (1:1):
Acute oral toxicity : LD50 Oral (Rat): 47 mg/kg
Method: OECD Test Guideline 401
GLP: no
Acute dermal toxicity : LD50 Dermal (Rat): 537 mg/kg
LD50 Dermal (Rabbit): > 200 - < 500 mg/kg
Method: OECD Test Guideline 402
GLP: yes
Skin corrosion/irritation
Not classified based on available information.
Ingredients:
1,3-Propanediol, 2,2-bis(hydroxymethyl)-:
Species : Rabbit
Result : No skin irritation
Serious eye damage/eye irritation
Not classified based on available information.
Ingredients:
1,3-Propanediol, 2,2-bis(hydroxymethyl)-:
Species : Rabbit
Result : No eye irritation
Respiratory or skin sensitization
Skin sensitization
Not classified based on available information.
Respiratory sensitization
Not classified based on available information.
Ingredients:
1,3-Propanediol, 2,2-bis(hydroxymethyl)-:
Species : Mouse
Method : OECD Test Guideline 429
Result : Did not cause sensitization on laboratory animals.
Germ cell mutagenicity
Not classified based on available information.
6 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
Ingredients:
1,3-Propanediol, 2,2-bis(hydroxymethyl)-:
Genotoxicity in vitro : Test Type: Ames test
Test system: Salmonella typhimurium
Method: OECD Test Guideline 471
Result: negative
Test system: Chinese hamster cells
Concentration: 1,4
Method: OECD Test Guideline 473
Result: negative
Test system: mouse lymphoma cells
Method: OECD Test Guideline 476
Result: negative
Test Type: Ames test
Test system: Escherichia coli
Method: OECD Test Guideline 471
Result: negative
Carcinogenicity
Not classified based on available information.
Ingredients:
1,3-Propanediol, 2,2-bis(hydroxymethyl)-:
Species : Rat
Application Route : Oral
Group : yes
NOAEL : 1,000 mg/kg bw/day
Result : negative
IARC No ingredient of this product present at levels greater than or equal to 0.1% is
identified as probable, possible or confirmed human carcinogen by IARC.
OSHA No component of this product present at levels greater than or equal to 0.1% is
on OSHA’s list of regulated carcinogens.
NTP No ingredient of this product present at levels greater than or equal to 0.1% is
identified as a known or anticipated carcinogen by NTP.
Reproductive toxicity
Not classified based on available information.
STOT-single exposure
Not classified based on available information.
Ingredients:
Methanaminium, N,N,N-trimethyl-, chloride (1:1):
Assessment : Causes damage to organs.
7 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
STOT-repeated exposure
Not classified based on available information.
Repeated dose toxicity
Ingredients:
1,3-Propanediol, 2,2-bis(hydroxymethyl)-:
Species : Rat
NOAEL : 100 mg/kg
Application Route : Oral
Group : yes
Symptoms : Diarrhea
Remarks : No significant adverse effects were reported
Methanaminium, N,N,N-trimethyl-, chloride (1:1):
Species : Rat
NOAEL : 5 mg/kg
Application Route : Oral
Method : OECD Test Guideline 421
GLP : yes
Aspiration toxicity
Not classified based on available information.
Further information
Ingredients:
Methanaminium, N,N,N-trimethyl-, chloride (1:1):
Remarks : Other dangerous properties can not be excluded.
SECTION 12. ECOLOGICAL INFORMATION
Cfas USA F1-oSw
Ecotoxicity
Ingredients:
1,3-Propanediol, 2,2-bis(hydroxymethyl)-:
Toxicity to fish : LC50 (Leuciscus idus (Golden orfe)): > 5,000 mg/l
Exposure time: 48 h
LC50 (Oryzias latipes (Orange-red killifish)): > 100 mg/l
Exposure time: 96 h
NOEC (Oncorhynchus mykiss (rainbow trout)): 56 mg/l
Exposure time: 96 h
LC50 (Brachydanio rerio (zebrafish)): > 1,000 mg/l
Exposure time: 96 h
Method: OECD Test Guideline 203
8 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
Toxicity to daphnia and other : EC50 (Daphnia magna (Water flea)): 38,900 mg/l
aquatic invertebrates Exposure time: 24 h
NOEC (Daphnia magna (Water flea)): 1,000 mg/l
Exposure time: 24 h
EC50 (Daphnia magna (Water flea)): 3,560 mg/l
Exposure time: 48 h
Method: OECD Test Guideline 202
Toxicity to algae : EbC50 (Desmodesmus subspicatus (green algae)): > 100
mg/l
Exposure time: 72 h
Method: OECD Test Guideline 201
ErC50 (Desmodesmus subspicatus (green algae)): > 100 mg/l
Exposure time: 72 h
Method: OECD Test Guideline 201
NOEC (Desmodesmus subspicatus (green algae)): 100 mg/l
Exposure time: 72 h
Method: OECD Test Guideline 201
EC50 (Scenedesmus quadricauda (Green algae)): > 1,000
mg/l
Exposure time: 72 h
Method: OECD Test Guideline 201
Toxicity to microorganisms : (Pseudomonas putida): > 500 mg/l
Exposure time: 0.5 h
Methanaminium, N,N,N-trimethyl-, chloride (1:1):
Toxicity to fish : LC50 (Pimephales promelas (fathead minnow)): 462 mg/l
Exposure time: 96 h
Toxicity to daphnia and other : EC50 (Daphnia magna (Water flea)): 0.16 mg/l
aquatic invertebrates Exposure time: 11 d
GLP: yes
NOEC (Daphnia magna (Water flea)): 0.03 mg/l
Exposure time: 11 d
GLP: yes
LC50 (Daphnia magna (Water flea)): 1.86 mg/l
Exposure time: 48 h
GLP: yes
Toxicity to algae : ErC50 (Pseudokirchneriella subcapitata (green algae)): 115
mg/l
Exposure time: 72 h
Method: OECD Test Guideline 201
GLP: yes
9 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
Ecotoxicology Assessment
Chronic aquatic toxicity : Toxic to aquatic life with long lasting effects.
Toxicity Data on Soil : Not expected to adsorb on soil.
Other organisms relevant to : No data available
the environment
Persistence and degradability
Ingredients:
1,3-Propanediol, 2,2-bis(hydroxymethyl)-:
Biodegradability : Result: Inherently biodegradable.
Biodegradation: 99 %
Exposure time: 28 d
Method: OECD Test Guideline 301
Methanaminium, N,N,N-trimethyl-, chloride (1:1):
Biodegradability : Remarks: Expected to be biodegradable
Bioaccumulative potential
Ingredients:
1,3-Propanediol, 2,2-bis(hydroxymethyl)-:
Partition coefficient: n- : log Pow: -1.7 (22 °C / 22 °C)
octanol/water
Methanaminium, N,N,N-trimethyl-, chloride (1:1):
Partition coefficient: n- : Remarks: No data available
octanol/water
Mobility in soil
No data available
Other adverse effects
SECTION 13. DISPOSAL CONSIDERATIONS
Disposal methods
Waste from residues : Special treatment as infectious material is mandatory in com-
pliance with local regulations (disinfection and incineration).
Can be disposed as waste water, when in compliance with
local regulations.
Contaminated packaging : Empty containers should be taken to an approved waste
handling site for recycling or disposal.
Do not re-use empty containers.
10 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
SECTION 14. TRANSPORT INFORMATION
International Regulations
UNRTDG
Not regulated as a dangerous good
IATA-DGR
Not regulated as a dangerous good
IMDG-Code
Not regulated as a dangerous good
Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code
Not applicable
Domestic regulation
49 CFR
Not regulated as a dangerous good
SECTION 15. REGULATORY INFORMATION
Cfas USA F1-oSw
EPCRA - Emergency Planning and Community Right-to-Know
CERCLA Reportable Quantity
Ingredients CAS-No. Component RQ Calculated product RQ
(lbs) (lbs)
Copper(II) sulfate, pentahydrate 7758-99-8 10 *
*: Calculated RQ exceeds reasonably attainable upper limit.
SARA 304 Extremely Hazardous Substances Reportable Quantity
Ingredients CAS-No. Component RQ Calculated product RQ
(lbs) (lbs)
Sodium azide (Na(N3)) 26628-22-8 1000 *
*: Calculated RQ exceeds reasonably attainable upper limit.
SARA 302 Extremely Hazardous Substances Threshold Planning Quantity
This material does not contain any components with a section 302 EHS TPQ.
SARA 311/312 Hazards : No SARA Hazards
SARA 313 : This material does not contain any chemical components with
known CAS numbers that exceed the threshold (De Minimis)
reporting levels established by SARA Title III, Section 313.
Clean Air Act
This product neither contains, nor was manufactured with a Class I or Class II ODS as defined by
the U.S. Clean Air Act Section 602 (40 CFR 82, Subpt. A, App.A + B).
This product does not contain any hazardous air pollutants (HAP), as defined by the U.S. Clean
Air Act Section 112 (40 CFR 61).
This product does not contain any chemicals listed under the U.S. Clean Air Act Section 112(r) for
Accidental Release Prevention (40 CFR 68.130, Subpart F).
11 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
The following chemical(s) are listed under the U.S. Clean Air Act Section 111 SOCMI Intermedi-
ate or Final VOC's (40 CFR 60.489):
1,3-Propanediol, 2,2- 115-77-5 >= 10 - < 20 %
bis(hydroxymethyl)-
Sodium acetate trihy- 6131-90-4 >= 1 - < 5 %
drate
Clean Water Act
The following Hazardous Substances are listed under the U.S. CleanWater Act, Section 311, Ta-
ble 116.4A:
Iron(II) sulfate heptahy- 7782-63-0 >= 0 - < 0.1 %
drate
Copper(II) sulfate, pen- 7758-99-8 >= 0 - < 0.1 %
tahydrate
The following Hazardous Chemicals are listed under the U.S. CleanWater Act, Section 311, Table
117.3:
Iron(II) sulfate heptahy- 7782-63-0 >= 0 - < 0.1 %
drate
Copper(II) sulfate, pen- 7758-99-8 >= 0 - < 0.1 %
tahydrate
This product does not contain any toxic pollutants listed under the U.S. Clean Water Act Section
307
US State Regulations
Massachusetts Right To Know
1,3-Propanediol, 2,2-bis(hydroxymethyl)- 115-77-5
Pennsylvania Right To Know
Human serum /-plasma / -hemolysate, lyophilized Not Assigned
1,3-Propanediol, 2,2-bis(hydroxymethyl)- 115-77-5
1-Piperazineethanesulfonic acid, 4-(2-hydroxyethyl)- 7365-45-9
Albumins, blood serum 9048-46-8
Whole Chicken egg, lyo. Not Assigned
Manganese (II) chloride, tetrahydrate 13446-34-9
Maine Chemicals of High Concern
Product does not contain any listed chemicals
Vermont Chemicals of High Concern
Product does not contain any listed chemicals
Washington Chemicals of High Concern
Product does not contain any listed chemicals
California Prop. 65
WARNING: This product can expose you to chemicals including Carbonic acid, lithium salt (1:2),
which is/are known to the State of California to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.
California Permissible Exposure Limits for Chemical Contaminants
1,3-Propanediol, 2,2-bis(hydroxymethyl)- 115-77-5
The ingredients of this product are reported in the following inventories:
DSL : This product contains the following components that are not
on the Canadian DSL nor NDSL.
12 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
Human serum /-plasma / -hemolysate, lyophilized
Whole Chicken egg, lyo.
Dextrose
Lipoproteins from blood plasma
Pyridoxal 5-Phosphate, Monohydrate
Creatine monohydrate
Ficoll 70
Creatine kinase
Alanine aminotransferase
Acid phosphatase
Alkaline phosphatase
Aspartate aminotransferase
.alpha.-Amylase
Fructose bisphosphate aldolase
Triacylglycerol lipase
.gamma.-Glutamyltransferase
Dehydrogenase, glutamate
Bovine Serum Albumin
AICS : Not in compliance with the inventory
NZIoC : On the inventory, or in compliance with the inventory
ENCS : Not in compliance with the inventory
ISHL : Not in compliance with the inventory
KECI : Not in compliance with the inventory
PICCS : Not in compliance with the inventory
IECSC : Not in compliance with the inventory
TCSI : Not in compliance with the inventory
TSCA : Not On TSCA Inventory
13 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
TSCA list
No substances are subject to a Significant New Use Rule.
No substances are subject to TSCA 12(b) export notification requirements.
Cfas USA F1-oSw
GHS label elements
Not a hazardous substance or mixture.
SECTION 16. OTHER INFORMATION
Further information
Cfas USA F1-oSw
NFPA: HMIS® IV:
Flammability
HEALTH / 0
0
FLAMMABILITY
Instability
0
Health
0 0
PHYSICAL HAZARD
0
HMIS® ratings are based on a 0-4 rating
scale, with 0 representing minimal haz-
ards or risks, and 4 representing signifi-
Special hazard.
cant hazards or risks. The "*" represents
a chronic hazard, while the "/" represents
the absence of a chronic hazard.
Full text of other abbreviations
AICS - Australian Inventory of Chemical Substances; ASTM - American Society for the Testing of
Materials; bw - Body weight; CERCLA - Comprehensive Environmental Response, Compensation,
and Liability Act; CMR - Carcinogen, Mutagen or Reproductive Toxicant; DIN - Standard of the
German Institute for Standardisation; DOT - Department of Transportation; DSL - Domestic Sub-
stances List (Canada); ECx - Concentration associated with x% response; EHS - Extremely Haz-
ardous Substance; ELx - Loading rate associated with x% response; EmS - Emergency Schedule;
ENCS - Existing and New Chemical Substances (Japan); ErCx - Concentration associated with
x% growth rate response; ERG - Emergency Response Guide; GHS - Globally Harmonized Sys-
tem; GLP - Good Laboratory Practice; HMIS - Hazardous Materials Identification System; IARC -
International Agency for Research on Cancer; IATA - International Air Transport Association; IBC
- International Code for the Construction and Equipment of Ships carrying Dangerous Chemicals
in Bulk; IC50 - Half maximal inhibitory concentration; ICAO - International Civil Aviation Organiza-
tion; IECSC - Inventory of Existing Chemical Substances in China; IMDG - International Maritime
Dangerous Goods; IMO - International Maritime Organization; ISHL - Industrial Safety and Health
Law (Japan); ISO - International Organisation for Standardization; KECI - Korea Existing Chemi-
14 / 15
SAFETY DATA SHEET
Calibrator for automated systems
Version Revision Date: Date of last issue: 06-14-2018
1.5 08-01-2018 Date of first issue: 11-05-2015
cals Inventory; LC50 - Lethal Concentration to 50 % of a test population; LD50 - Lethal Dose to
50% of a test population (Median Lethal Dose); MARPOL - International Convention for the Pre-
vention of Pollution from Ships; MSHA - Mine Safety and Health Administration; n.o.s. - Not Oth-
erwise Specified; NFPA - National Fire Protection Association; NO(A)EC - No Observed (Adverse)
Effect Concentration; NO(A)EL - No Observed (Adverse) Effect Level; NOELR - No Observable
Effect Loading Rate; NTP - National Toxicology Program; NZIoC - New Zealand Inventory of
Chemicals; OECD - Organization for Economic Co-operation and Development; OPPTS - Office
of Chemical Safety and Pollution Prevention; PBT - Persistent, Bioaccumulative and Toxic sub-
stance; PICCS - Philippines Inventory of Chemicals and Chemical Substances; (Q)SAR - (Quanti-
tative) Structure Activity Relationship; RCRA - Resource Conservation and Recovery Act;
REACH - Regulation (EC) No 1907/2006 of the European Parliament and of the Council concern-
ing the Registration, Evaluation, Authorisation and Restriction of Chemicals; RQ - Reportable
Quantity; SADT - Self-Accelerating Decomposition Temperature; SARA - Superfund Amend-
ments and Reauthorization Act; SDS - Safety Data Sheet; TCSI - Taiwan Chemical Substance
Inventory; TSCA - Toxic Substances Control Act (United States); UN - United Nations; UNRTDG -
United Nations Recommendations on the Transport of Dangerous Goods; vPvB - Very Persistent
and Very Bioaccumulative
Revision Date : 08-01-2018
The information provided in this Material Safety Data Sheet is correct to the best of our
knowledge, information and belief at the date of its publication. The information given is designed
only as a guidance for safe handling, use, processing, storage, transportation, disposal and re-
lease and is not to be considered a warranty or quality specification. The information relates only
to the specific material designated and may not be valid for such material used in combination
with any other materials or in any process, unless specified in the text.
US / Z8 / 1711
15 / 15