0% found this document useful (0 votes)
27 views1 page

Design CHO

This document calculates the discharge and headloss for a canal called TA-1-2L. It provides details on the canal area, flow rate, diameter, and length. It then calculates the entrance loss, pipe friction loss, and total headloss in feet and millimeters, accounting for factors like flow velocity, roughness, and length. The total calculated headloss is 0.331066 feet or 99 millimeters.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views1 page

Design CHO

This document calculates the discharge and headloss for a canal called TA-1-2L. It provides details on the canal area, flow rate, diameter, and length. It then calculates the entrance loss, pipe friction loss, and total headloss in feet and millimeters, accounting for factors like flow velocity, roughness, and length. The total calculated headloss is 0.331066 feet or 99 millimeters.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Discharge and Headloss Calculation for CHO

Canal = TA-1-2L

Area = 42.72 ha
Q = 179.42 l/s g = 32.2 ft/s
Q = 6.3355 ft³/s D = 2 ft
A = πD²/2
= 3.142 ft²
1) Entrance loss = 0.78hv
hv = v² V = Q = 2.016 ft/s
2g A
= 0.063 ft

2) Pipe Friction Loss = hf.L , n = 0.015 , L= 18 ft


= 2.86 v² n² .L
4/3
D

= 0.018689 ft

3) Total Loss = 0.2+0.78hv + hf.L + 1.0 hv


= 0.331066 ft
= 99 mm