0% found this document useful (0 votes)
151 views3 pages

Circuit Breaker Testing Library ENU

The document discusses the Circuit Breaker Testing Library (CBTL) database provided by Omicron which contains data on circuit breakers. It describes how to access, license, install, update, customize and load data from the CBTL database within Omicron's Primary Test Manager software.

Uploaded by

madhavan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
151 views3 pages

Circuit Breaker Testing Library ENU

The document discusses the Circuit Breaker Testing Library (CBTL) database provided by Omicron which contains data on circuit breakers. It describes how to access, license, install, update, customize and load data from the CBTL database within Omicron's Primary Test Manager software.

Uploaded by

madhavan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

14 Circuit Breaker Testing Library

The Circuit Breaker Testing Library (CBTL) is a database of circuit breakers provided by OMICRON. You
can use it to specify your assets by loading the available data from the library into Primary Test Manager.
You can find a list of circuit breakers available in the CBTL on the OMICRON Customer Portal.
To go to this site:
1. Visit our website at www.omicronenergy.com, and then log in to the Customer Portal.
2. On the menu, click Software, and then click CIBANO 500.

14.1 Licensing
To use the Circuit Breaker Testing Library, you need a license. To get the license, contact your regional
OMICRON Service Center or sales partner. You can find our Service Center or sales partner closest to
you at www.omicronenergy.com. For information on how to enter the license key, see 6.4 "About" in the
CIBANO 500 PTM User Manual.

14.2 Installation
You can install the Circuit Breaker Testing Library by running the installation file
CBTLSetup X.YZ SR1.exe, where X.YZ is the Primary Test Manager version. You can find the
installation file:
• On the delivered Circuit Breaker Testing Library DVD at
.\CBTLSetup X.YZ SR1.exe
• On the OMICRON Customer Portal
To go to the installation file, click Software, and then click CIBANO 500.
► To install the Circuit Breaker Testing Library, double-click the installation file.

14.3 Updating the CBTL


The installed Circuit Breaker Testing Library is periodically checked for updates. If an update is available,
the CBTL updater will prompt you to update the library. To update the CBTL without the prompt:
1. On the taskbar, click the Start button.
2. Expand the OMICRON folder, and then click Check for Circuit Breaker Testing Library updates.

14.4 Customizing the CBTL


You can customize the OMICRON Circuit Breaker Testing Library by adding your own asset data.
To add asset data to the Circuit Breaker Testing Library:
1. In the asset view, specify the asset.
2. Click Save to asset library on the ribbon.
You can export and import your own asset data from and into the Circuit Breaker Testing Library in
PTMLIB format.

OMICRON 95
CIBANO 500 PTM User Manual

To export asset data from the Circuit Breaker Testing Library:


1. On the Templates and libraries tab of the Settings dialog box, select the asset you want to export.
Note: You can filter the displayed data. To display the job templates, OMICRON CBTL data and your
own asset data, select the respective check boxes.

Figure 14-1: Exporting asset data into the Circuit Breaker Testing Library

2. Click the Export the selected template button .


3. Browse to the folder where you want to save the file.
To import asset data into the Circuit Breaker Testing Library:
1. On the Templates and libraries tab of the Settings dialog box, click Import template button .
2. Browse to the file you want to import.

96 OMICRON
14.5 Working with the CBTL
To load data from the Circuit Breaker Testing Library:
1. In the asset view, select Circuit breaker from the Asset list.

Figure 14-2: Loading data from the Circuit Breaker Testing Library

2. Click Load from asset library on the ribbon.

Figure 14-3: Choose Template dialog box

3. In the Choose Template dialog box, select the manufacturer, the manufacturer type and the name
of the circuit breaker you want to specify, and then click OK.

OMICRON 97

You might also like