Centaur 40: Gas Turbine Generator Set

The document provides specifications for the Centaur 40 gas turbine generator set for power generation. It details the main components of the industrial single-shaft gas turbine, including an 11-stage axial compressor, annular combustion chamber, and 3-stage reaction power turbine. It also describes the mechanical construction, electrical system, control system, fuel system, and performance parameters of the complete generator package.

Uploaded by

NK
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
738 views2 pages

Centaur 40: Gas Turbine Generator Set

The document provides specifications for the Centaur 40 gas turbine generator set for power generation. It details the main components of the industrial single-shaft gas turbine, including an 11-stage axial compressor, annular combustion chamber, and 3-stage reaction power turbine. It also describes the mechanical construction, electrical system, control system, fuel system, and performance parameters of the complete generator package.

Uploaded by

NK
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

CENTAUR 40

Gas Turbine Generator Set

Power Generation

General Specifications
Centaur ® 40 Gas Turbine
• Industrial, Single-Shaft • NEMA Class F Insulation • Turbine Compressor Cleaning Systems
• 11 Stage Axial Compressor • Class F Temperature Rise – On-Crank/On-Line
– Variable Inlet Guide Vanes and Stators • Class B Temperature Rise* – Portable Cleaning Tank*
– Pressure Ratio: 10:1 • Continuous Duty Rating Voltages: • Package Power
– Inlet Airflow: 18.7 kg/sec (41.3 lb/sec) – 3300, 6600, 11 000 (50Hz) – 120VDC Battery/Charger System*
– Vertically Split Case – 4160, 6900, 12 470, 13 200, 13 800 (60Hz) • Turbotronic™ On-Skid Gas Turbine and
• Combustion Chamber, Annular-Type Generator Control System Features
Package
– 10 Conventional Fuel Injectors or – Combination Generator Control Module
• Mechanical Construction with Load Share, Auto Synchronization,
12 Lean-Premixed, Dry Low – Steel Base Frame with Drip Pans
Emissions SoLoNOx™ Injectors Voltage Control
– 316L Stainless Steel Piping – Standard Display with Discrete Event Log,
– Single Torch Ignitor System – Compression Type Tube Fittings Strip Chart, Historical Trend,
• Power Turbine • Start System Maintenance Screen
– 3-Stage Reaction – Direct Drive AC Motor with VFD Control – Vibration and Temperature Monitoring
– Clockwise Rotation • Package Electrical Certification – English Display Text and Labels
• Bearings – NEC, CSA Class 1, Group D, Div.2 – Spanish, Portuguese, German, French
– 3 Radial Journal: Tilt-Pad • Fuel System or Simplified Chinese Display Text
– Thrust, Active: Tilt-Pad – Natural Gas and Labels*
– Thrust, Inactive: Fixed Tapered Land – Diesel* – Auxiliary and Remote Display/Control
• Coatings – Dual (Natural Gas and Diesel)* Terminals*
– Compressor: Inorganic Aluminum – Low BTU Gas* – Turbine Performance Map*
– Turbine and Nozzle Blades: Precious • Integrated Lube Oil System – KW Import Control*
Metal Diffusion Aluminide – Turbine-Driven Lube Pump – KVAR/Power Factor Control*
• Vibration Monitoring – AC Motor Driven Pre/Post Lube Pump – ControlNet Redundant Media, Ethernet,
– DC Motor Driven Backup Lube Pump Data Highway Plus or Modbus
– Velocity Transducers
– Air to Oil Cooler RS232C/422/485 Supervisory Interface*
Main Reduction Drive – Water to Oil Cooler* – Heat Recovery Application Interface*
• Epicyclic Type – Integral Lube Oil Tank – Multi-Unit Applications: Load Shed Control,
– 1500 or 1800 rpm (50 or 60 Hz) – Lube Oil Tank Heater Import/Export or kW/KVAR Control Panels*
– Vibration monitoring: Acceleration – Lube Oil Filter – InSight Platform™ Equipment Health
Transducer – Duplex Lube Oil Filter* Management*
Generator – Oil Tank Vent Separator with – Printer/Logger*
Flame Arrestor • Electrical System Options
• 4 Pole, 3 Phase, 6 Wire, Wye Connected,
• Air Inlet and Exhaust Systems – Neutral Grounding Resistor or Transformer*
Synchronous with Permanent Magnet
– Carbon Steel – Switchgear and Generator Protective Relay*
Generator Exciter
– Stainless Steel* – Motor Control Center with Automatic
• Available Construction Types: Transfer Switch*
– Open Drip-Proof Construction – Barrier Type Filters
– Self-Cleaning Filters • Documentation
– CACA/TEAAC (Closed Air, Cooling Air/
– Inlet and Exhaust Silencers – Drawings
Totally Enclosed, Air to Air Cooling)*
– Inlet Evaporative Cooler* – Quality Control Data Book
– CACW/TEWAC (Closed Air, Cooling
– Inlet Chiller Coils* – Inspection and Test Plan
Water/Totally Enclosed, Water to Air
• Enclosure – Test Reports
Cooling)*
– Complete Package – O&M Manuals
• Sleeve Bearings
– Driver Only* • Factory Testing of Turbine
• Vibration Monitoring; Velocity Transducers – Fire Detection and CO2 Suppression • Factory Testing of Package Systems
• Vibration Monitoring; Displacement System – Non-Dynamic
Transducers* – Dynamic

* Option
CENTAUR 40
Gas Turbine Generator Set

Power Generation

Performance Available Power


Output Power 3515 kWe 5000 14.5
(13,750)
Heat Rate 12 910 kJ/kWe-hr
(12,240 Btu/kWe-hr) Output Power

HEAT RATE, MJ/kW-hr (Btu/kWe-hr)


14.0
4500
(13,270)
Exhaust Flow 68 365 kg/hr

OUTPUT POWER, kWe


(150,715 lb/hr)
13.5
Exhaust Temp. 445°C 4000 (12,320)
(830°F)

13.0
Application Performance 3500 (12,320)
Steam (Unfired) 8.9 tonnes/hr
(19,600 lb/hr)
12.5
Steam (Fired) 50.9 tonnes/hr 3000 (11,850)
1536°C (2800°F) (112,190 lb/hr) Heat Rate
12.0
Chilling (Absorp.) 7670 kW
(2180 refrigeration tons) 2500 (11,370)
-30.0 -15.0 0.0 15.0 30.0 45.0
Nominal rating – per ISO (-22) (5) (32) (59) (86) (113)
At 15°C (59°F), sea level
INLET AIR TEMPERATURE, °C (°F)
No inlet/exhaust losses DS40PG-002M

Relative humidity 60%


Natural gas fuel with
LHV = 35 MJ/Nm3 (940 Btu/scf)
No accessory losses
Engine efficiency: 27.9%
(measured at generator terminals)

Enclosure Access and Maintenance Space

3.0 mm
3048 m 9.8 m
9800 mm
(10’ 4”) (32’ 3")
(32' 3”)
(9' 10")

MINIMUM SPACE CLEARANCE


2.6 mm
2477 m GENERATOR REQUIRED FOR ENCLOSURE
(8’(8'
1-1/2”)
6") MAINTENANCE ACCESS DOORS AND
ROUTINE OPERATION
AND MAINTENANCE

MINIMUM CLEARANCE REQUIRED


3.0 mm
3048 m
FOR ENGINE REMOVAL (9’11”)
(9' 10")

9.8 m
9754 mm
(32’ 3")
(32' 0”)
DS40,50,60PG-003C
Package Height: 3.2 m (10' 5")
Package Weight: 30 460 kg (67,150 lb) Dry weight, enclosed height

Solar Turbines Incorporated


P.O. Box 85376 FOR MORE INFORMATION
San Diego, CA 92186-5376 Telephone: (+1) 619-544-5352
Caterpillar is a trademark of Caterpillar Inc.
Solar, Centaur, SoLoNOx, InSight Platform and Turbotronic are trademarks of Solar Turbines Incorporated. Email: [email protected]
Specifications subject to change without notice. Internet: www.solarturbines.com
© 2018 Solar Turbines Incorporated. All rights reserved.
DS40PG/1118/EO