Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx
for level measurement Order No.: see Table 1 / Page 4
Features Picture
Two wire system
Piezoresistive measuring element
Pressure measurement relative or absolute
Output signal 4-20 mA,
adjustable within 1 : 4 of the original measuring
range
Conformity error ≤ ±0.1 % FS
Standard DIN measuring ranges from
0 …100 mbar up to 0 … 160 bar or selection of
measuring ranges in mWC or psi
Temperature compensation within
-10°C ... +50°C [+14°F ... +122°F] or
-25°C ... +85°C [-13°F ... +185°F]
Optional overvoltage (lightning) protection
according to EN 61000-4-5
Compact and robust
Specifications
All specifications, unless otherwise noted, at DC 24 V supply voltage, R L = 100 , Tamb = 25°C [77°F].
Measurement Range Independent Technical Data
Type Two wire current transmitter
Output signal 4 … 20 mA
Resolution 12 bit (< 0.025 % FS)
Interface for adjustment HART-like
Output 0% adjustability -5% of orig. FS ... +105% of orig. FS (rel. measurement))
0% of orig. FS ... +105% of orig. FS (abs. measurement)
Output 100% adjustability -5% of original FS ... +105% of original FS
Difference (0% - 100%) adjustability ≥ 25% of original FS and ≥ 50 mbar [0.725 psi]
Damping adjustability ~ 30 ms (default), 100 ms, 1 s, 10 s
= 30 Hz (default), 10 Hz, 1 Hz, 0.1 Hz cut-off frequency
Supply voltage DC 9 ... 33 V
Reverse polarity protection integrated, standard
Overvoltage (lightning) protection optional
Supply voltage influence < 0.1 % FS
Dielectric strength case / supply 500 V
Load resistance limitation RL ] (+UB [V] - 9 [V]) / 0.02 [A]
Load resistance influence < 0.1 % FS
Protection class IP65 (~NEMA6)
Medium temperature range 0°C ... +80°C [+32°F ... +176°F] standard
-25°C ... +100°C [-13°F ... +212°F] option
Temperature Compensation range -10°C ... +50°C [+14°F ... +122°F] standard
-25°C ... +85°C [-13°F ... +185°F] option
Storage temperature range see medium temperature range
201211 PJ/Ges/Pen Subject to change Page 1/8
DG DKap Stamm-Bez. Var Ind F Sp
Data Sheet Hardware 21.210.1560204.001.06.4.4
2012 by Rittmeyer AG, CH-6341 Baar
Pressure Transmitter 4-20mA 2-wire MPG MPGxxxxxxxx
Acid resistance pH5 ... pH9
Weight approx. 160 g [0.35 lb.] without surge protection
approx. 170 g [0.37 lb.] with surge protection
Measuring cell, diaphragm, housing Stainless steel 1.4435 (316L)
Seals Viton
Pressure connection by choice G 1/2 A or 1/2 NPT A
Electrical connection by choice Connector DIN 43650 (IP65 ~NEMA4) or
Binder 723, (IP67 ~NEMA6), 5-pin
Electromagnetic Compatibility
Emission
Generic emission standard EN 61000-6-3
Emission, class B EN 55022
Immunity
Generic immunity standard EN 61000-6-2
Electrostatic discharge EN 61000-4-2 (4 kV contact, 8 kV air)
Radiated electro-magnetic field EN 61000-4-3 (10 V/m, 80 ... 1000 MHz, 80% AM 1 kHz)
Radiated electro-magnetic field (GSM) EN 61000-4-3 (10 V/m, 950 MHz, 200 Hz on/off)
Fast transients (burst) EN 61000-4-4 (2 kV)
Conducted radio-frequency EN 61000-4-6 (10 V, 0.15 ... 80 MHz, 80% AM 1 kHz)
Surge EN 61000-4-5 (10 kA 8/20s)
[only with the option overvoltage (lightning) protection]
Quality Tests
The transmitters fulfil the requirements for noise immunity and emissions of the EMC directive
89/336/EEC.
Measurement Range Specific Technical Data
Pressure ranges < 0.2 bar ≥ 0.2 ... 1 bar ≥ 1 ... 160 bar
[2.9 psi] [2.9...14.5 psi] [14.5...362.6 psi]
Overload 3 bar [43.5 psi] 3 bar [43.5 psi] 3 x FS
Bursting pressure ≥ 200 bar [2900 psi] ≥ 200 bar [2900 psi] ≥ 200 bar (≤ 25 bar FS)
[2900 psi (≤ 363 psi FS)]
≥ 850 bar (> 25 bar FS)
[12328 psi (> 363 psi FS)]
Conformity error incl. hysteresis
and repeatability
-10°C ... +50°C [+14°F...+122°F] ≤ ±0.2 % FS ≤ ±0.1 % FS ≤ ±0.1 % FS
-25°C ... +85°C [-13°F...+185°F] ≤ ±0.2 % FS ≤ ±0.1 % FS ≤ ±0.1 % FS
Temperature error zero / span
-10°C ... +50°C typ. ≤ ±100 ppm FS/°C ≤ ±60 ppm FS/°C ≤ ±60 ppm FS/°C
[+14°F...+122°F] max. ≤ ±150 ppm FS/°C ≤ ±100 ppm FS/°C ≤ ±100 ppm FS/°C
-25°C ... +85°C typ. ≤ ±200 ppm FS/°C ≤ ±150 ppm FS/°C ≤ ±150 ppm FS/°C
[-13°F...+185°F] max. ≤ ±250 ppm FS/°C ≤ ±200 ppm FS/°C ≤ ±200 ppm FS/°C
Long term drift typ. ≤ 0.2 % FS/a ≤ 0.2 % FS/a ≤ 0.1 % FS/a
201211 PJ/Ges/Pen Subject to change Page 2/8
DG DKap Stamm-Bez. Var Ind F Sp
Data Sheet Hardware 21.210.1560204.001.06.4.4
2012 by Rittmeyer AG, CH-6341 Baar
Pressure Transmitter 4-20mA 2-wire MPG MPGxxxxxxxx
Dimensions [mm]
[Ø0.95"]
Ø24
L = 74 mm [2.91"] with / without overvoltage protection
L
Pressure connectors: Electrical connectors:
DIN 43650 connector, standard
46.5 [1.83"]
Standard
13.5 [0.53"] SW27
[WS 11/16"]
G1/2 M
1 2
32.5 [1.28"]
Binder 723, 5-pin connector
17 [0.67"] SW27
3
[WS 11/16"]
2 4
1/2-NPT M
1 5
31.5 [1.24"]
68 [2.7"]
201211 PJ/Ges/Pen Subject to change Page 3/8
DG DKap Stamm-Bez. Var Ind F Sp
Data Sheet Hardware 21.210.1560204.001.06.4.4
2012 by Rittmeyer AG, CH-6341 Baar
Pressure Transmitter 4-20mA 2-wire MPG MPGxxxxxxxx
Ordering Information
Table 1: The exact order number for an article is formed from the individual options codes according to the
table (with the BAAN-Configurator PCF or manually).
MPG PCF Order Number
1/2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Type
MPG PG
Pressure type
Gauge 1
Absolut (vacuum) 2
Sealed gauge 3
Measurement range
0 ... 100 mbar = 0 ... 1.45 psi 0 0
0 ... 160 mbar = 0 ... 2.32 psi 0 1
0 ... 250 mbar = 0 ... 3.63 psi 0 2
0 ... 400 mbar = 0 ... 5.8 psi 0 3
0 ... 600 mbar = 0 ... 8.7 psi 0 4
0 ... 1.0 bar = 0 ... 14.5 psi 0 5
0 ... 1.6 bar = 0 ... 23.2 psi 0 6
0 ... 2.5 bar = 0 ... 36.25 psi 0 7
0 ... 4.0 bar = 0 ... 58 psi 0 8
0 ... 6.0 bar = 0 ... 87 psi 0 9
0 ... 10 bar = 0 ... 145 psi 1 0
0 ... 16 bar = 0 ... 232 psi 1 1
0 ... 25 bar = 0 ... 362.5 psi 1 2
0 ... 40 bar = 0 ... 580.2 psi 3 1 3
0 ... 60 bar = 0 ... 870.2 psi 3 1 4
0 ... 100 bar = 0 ... 1450.4 psi 3 1 5
0 ... 160 bar = 0 ... 2320.6 psi 3 1 6
0 ... 1 mWC 6 0
0 ... 2 mWC 6 1
0 ... 5 mWC 6 2
0 ... 10 mWC 6 3
0 ... 20 mWC 6 4
0 ... 50 mWC 6 5
0 ... 1.5 psi 7 0
0 ... 3.0 psi 7 1
0 ... 7.5 psi 7 2
0 ... 15 psi 7 3
0 ... 30 psi 7 4
0 ... 75 psi 7 5
0 ... 150 psi 7 6
0 ... 300 psi 7 7
Special range 9 9
Process connection
G1/2 M 1 3
1/2 NPT M 1 9
Electrical connection
Connector DIN 43650, IP65 * 0 1
Connector Binder 723, IP67, 5-pin * 0 3
Output signal
4 ... 20 mA without overvoltage (lightning) protection 0 5
4 ... 20 mA with overvoltage (lightning) protection 0 8
Accuracy
±0.2 % FS, only for FS < 200 mbar 4
±0.1 % FS, only for FS ≥ 200 mbar 2
Temperature range
Compensated -10°C ... +50°C (Medium 0 ... 80°C) 0
Compensated -25°C ... +85°C (Medium -25°C ... +100°C) 1
(Cable length)
always = 000 0 0 0
* The pressure transmitter always requires a plug-in cable coupling that has to be ordered separately.
201211 PJ/Ges/Pen Subject to change Page 4/8
DG DKap Stamm-Bez. Var Ind F Sp
Data Sheet Hardware 21.210.1560204.001.06.4.4
2012 by Rittmeyer AG, CH-6341 Baar
Pressure Transmitter 4-20mA 2-wire MPG MPGxxxxxxxx
Parameterisation
With the aid of the programming kit MPPKIT available as an accessory, the software of the pressure
transmitter can be parameterised with a PC (see also Data Sheet 21.210.0066900.001 and Operating
Instructions 21.810.0066900.001).
Range selection for output current 4 ... 20 mA
With the range selection 4 ... 20 mA, the 4 mA and 20 mA current values can be assigned to measured
values other than the standard 0% and 100% of the nominal measuring range. (Typically with 4 mA a
value from the range -5% ... +25% of the nominal measuring range, with 20 mA, a value from the range
+25% ... +105% of the nominal measuring range.) In this way, a sub-range or even a negative pressure
can be measured. The difference between the minimum and maximum must amount to at least 25% of
the nominal measuring range and be at least 50 mbar.
Inverted control can be achieved by exchanging the values for 4 mA and 20 mA.
The ranges of adjustability are presented graphically in the following illustrations:
Non-inverted Control: Inverted Control:
Output current Iout Output current Iout
25%FS 0,05bar 25%FS 0,05bar
20 mA 20 mA
Standard Example 1
Adjustability Example Example 2
Adjustability
range
range
(only rel.) Adjustability Adjustability
(only rel.)
range range
(rel. or abs.) (rel. or abs.)
4 mA 4 mA
Measured Measured
value p -5% 20% 80% 105%
value p
-5% 20% 80% 105%
0% 100% 0% 100%
Nominal Nominal
Working Range (FS) Working Range (FS)
Programmable Damping of the Current Output
The analog output can be damped with a low pass filter of the 1st order. The adjustability enables values
between ~ 33 ms (default) and 10 s.
Note: During commissioning, damping is preferably left at the minimum value.
Recalibrating the transmitter (calibration 0 % or 100 %) enables compensation of the drift which
inevitably occurs with resistive pressure transducers. The zero drift alone or the combination of zero drift
and slope change can be compensated. In doing so, the original calibration of the transmitter is not lost
and can be recalled as necessary.
Setting range 0%: -5% +5% of nominal measuring range (FS) with relative measuring probes
0% +5% of nominal measuring range (FS) with absolute measuring probes
Setting range 100%: 95% ... 105% of nominal measuring range (FS)
Standard Settings
The transducers have the following standard parameterisation:
Current range: 4 ... 20mA
Measurement start: 4 mA = 0% of nominal measurement range (FS)
Measurement end: 20 mA = 100% of nominal measurement range (FS)
Damping: ~ 30 ms
201211 PJ/Ges/Pen Subject to change Page 5/8
DG DKap Stamm-Bez. Var Ind F Sp
Data Sheet Hardware 21.210.1560204.001.06.4.4
2012 by Rittmeyer AG, CH-6341 Baar
Pressure Transmitter 4-20mA 2-wire MPG MPGxxxxxxxx
Block Diagram / Electrical Connections
+Vin RL [Ohm]
P
UB 1000 UB [V] - 9V
Pout RL <
I 0.02A
A
500
DIN 43650: +Vin = Pin 1
Pout = Pin 2 RL
Binder 723: +Vin = Pin 3
Pout = Pin 1 0
0 10 20 30
UB [V]
Note
The load resistance RL is the sum of load and cable resistance.
In order to prevent destruction, the membrane must not be touched.
For applications in the field with extension cables having a cable length ≥ 5 m [16 ft.] or inside a building
with cable lengths ≥ 100 m [330 ft.], a transmitter with the overvoltage protection option and an external
overvoltage protection PT1x2-24DC-SET or a junction box NLAD.MPG (at other end of the cable) must
be used.
The cable shield must be connected to a good ground potential.
In order to compensate the long term drift an annual zero point alignment is recommended.
Conversion table for pressure units
(value in new unit) = coefficient x (value in old unit)
coefficient new unit
2
old unit Pa = 1 N/m2 bar mWC ftWC mmHg (Torr) psi kp/cm = at
2 -5 -4 -3 -4 -5
Pa = 1 N/m 1 10 1.02 x 10 3.35 7.5 x 10 1.45 x 10 1.02 x 10
5
bar 10 1 10.2 33.5 750 14.5 1.02
3 -2
mWC 9.81 x 10 9.81 x 10 1 3.28 73.6 1.42 0.1
3 -2 -2
ftWC 2.99 x 10 2.99 x 10 0.305 1 22.4 0.433 3.05 x 10
2 -3 -2 -2 -2 -3
mmHg (Torr) 1.33 x 10 1.33 x 10 1.36 x 10 4.46 x 10 1 1.93 x 10 1.36 x 10
3 -2 -2
psi 6.89 x 10 6.89 x 10 0.703 2.31 51.7 1 7.03 x 10
2 4
kp/cm = at 9.81 x 10 0.981 10 32.8 736 14.2 1
Application example 2 bar = ? psi:
bar = "old unit", psi = "new unit", "coefficient" = 14.5
2 bar = 14.5 x 2 psi = 29 psi
201211 PJ/Ges/Pen Subject to change Page 6/8
DG DKap Stamm-Bez. Var Ind F Sp
Data Sheet Hardware 21.210.1560204.001.06.4.4
2012 by Rittmeyer AG, CH-6341 Baar
Pressure Transmitter 4-20mA 2-wire MPG MPGxxxxxxxx
Accessories
Abbreviation Order No.
Programming-Kit consisting of interface box and
Windows programming software (XP / VISTA / W7) MPPKIT 00 66 900.001
Cable connector without / with cable see configurator accessories MPG / MPJ (PZ)
Extension cable 2-wire, shielded (L in meter) MPZVK 04 60 502
Junction box IP66 (~NEMA 6) NLAD.KL8 00 65 190.100
Junction box IP66 (~NEMA 6), 1 OVP NLAD.MPG 00 65 190.103
OVP complete for analogue signal PT1x2-24DC-SET 22 50 215
Venting (PN 80) complete MPZLU 00 66 181.001
Wall mounting set MPZBMA 00 65 715.001
201211 PJ/Ges/Pen Subject to change Page 7/8
DG DKap Stamm-Bez. Var Ind F Sp
Data Sheet Hardware 21.210.1560204.001.06.4.4
2012 by Rittmeyer AG, CH-6341 Baar
Pressure Transmitter 4-20mA 2-wire MPG MPGxxxxxxxx
Intentionally left blank
201211 PJ/Ges/Pen Subject to change Page 8/8
DG DKap Stamm-Bez. Var Ind F Sp
Data Sheet Hardware 21.210.1560204.001.06.4.4
2012 by Rittmeyer AG, CH-6341 Baar