Homogenization Fundamentals
Poonam Dhankhar
M.Tech (Food tech), G.J .U.S & T, Hissar
Abstract: - Homogenization is a process of achieving homogeneity through out a product by particle size
modification. it is characterized into three major categories:-ultrasonic pressure homogenization, pressure
homogenization mechanical homogenizer. Application of homogenization are diverse in food industry, chemical
industry, pharmaceutical and chemical industry. Most important use of homogenization process in food industry
is in milk homogenization. Selection criteria of homogenizers depends on particular application.
I. INTRODUCTION
Homogeneity and heterogeneity are concepts relating to the uniformity or lack thereof in a substance.
A material that is homogeneous is uniform in composition or character; one that is heterogeneous lacks
uniformity in one of these qualities.The concepts are applicable to combinations at every level of complexity,
from atoms to populations of animals or people, to galaxies. Hence, a substance may be homogeneous on a
larger scale, compared to being heterogeneous on a smaller scale within the same substance (1)
]
"In 1899 Auguste Gaulin obtained a patent on his homogenizer. The patent consisted of a 3 piston pump in
which product was forced through one or more hair like tubes under pressure.
At the World’s Fair in Paris in 1900, Auguste Gaulin exhibited his invention… a process for “treating” milk.
According to the literature and publications of that time, the word “”homogenized” was first used to describe
milk treated by the Gaulin machine. Therefore, the terms “homogenization” and “homogenizer” historically
relate to the process and equipment developed by Gaulin. The homogenizer basically consists of a positive-
displacement pump to which is attached a homogenizing valve assembly. The pump forces fluids through the
homogenizing valve under pressure. The term “homogenization” refers to the process or action that occurs
within the homogenizing valve assembly. (4)
1) ULTRASONIC HOMOGENIZING:-
One widely used method to disrupt cells is ultrasonic disruption. These devices work by generating
intense sonic pressure waves in a liquid media. The pressure waves cause streaming in the liquid and, under the
right conditions, rapid formation of micro-bubbles which grow and coalesce until they reach their resonant size,
vibrate violently, and eventually collapse. This phenomenon is called cavitation. The implosion of the vapor
phase bubbles generates a shock wave with sufficient energy to break covalent bonds. Shear from the imploding
cavitation bubbles as well as from eddying induced by the vibrating sonic transducer disrupt cells. There are
several external variables which must be optimized to achieve efficient cell disruption. These variables are as
follows:
Tip amplitude and intensity
Temperature
Cell concentration
Pressure
Vessel capacity and shape
Modem ultrasonic processors use piezoelectric generators made of lead zirconate titanate crystals. The
vibrations are transmitted down a titanium metal horn or probe tuned to make the processor unit resonate at 15-
25 kHz. The rated power of ultrasonic processors vary from 10 to 375 Watts. low power output does not
necessarily mean that the cell disintegrator is less powerful because lower power transducers are generally
matched to probes having smaller tips. It is the power density at the tip that counts. Higher output power is
required to maintain the desired amplitude and intensity under conditions of increased load such as high
viscosity or pressure. The larger the horn, the more power is required to drive it and the larger the volume of
sample that can he processed. On the other hand, larger ultrasonic disintegrators generate considerable heat
during operation and will necessitate aggressive external cooling of the sample. Typical maximum tip
amplitudes are 30-250 urn and resultant output intensities are in the range of 200-2000 W/square cm.
The temperature of the sample suspension should be as low as possible. In addition to addressing the
usual concerns about temperature liability of proteins, low media temperatures promote high-intensity shock
front propagation. So ideally, the temperature of the ultrasonicated fluid should be kept just above its freezing
point. The ultrasonic disintegrator generates considerable heat during processing and this complicates matters.
Disruption can also be enhanced by increased hydrostatic pressure (typically 15-60 psi) and increased viscosity,
providing the ultrasonic processor has sufficient power to overcome the increased load demand and the
associated sample heating problems can be solved. For microorganisms the addition of glass beads in the 0.05 to
0.5mm size range enhances cell disruption by focusing energy released by the bubble implosions and by
physical crushing. Beads are almost essential for disruption of spores and yeast. A good ratio is one volume of
beads to two volumes of liquid. Tough tissues such as skin and muscle should be macerated first in a blender or
the like and confined to a small vessel during ultrasonic treatment. The tip should not be placed so shallow in
the vessel as to allow foaming. Antifoaming agents or other materials which lower surface tension should be
avoided. Finally, one must keep in mind that free radicals are formed in ultrasonic processes and that they are
capable of reading with biological material such as proteins, polysaccharides, or nucleic acids. Damage by
oxidative free radicals can be minimized by including scavengers like cysteine, dithiothreitol, or other SH
compounds in the media or by saturating the sample with a protective atmosphere of helium or hydrogen gas.
For practical reasons, the tip diameter of ultrasonic horns cannot exceed about 3 inches. This sets a limit on the
scale-up of these devices. While standard sized ultrasonic disrupters have been adapted to continuous operation
by placing the probe tip in a chamber through which a stream of cells flow, cooling and free radical release
present problems.
A familiar commercial high-pressure homogenizer for the laboratory is the French press which uses a
motor-driven piston inside a steel cylinder to develop pressures up to 40,000 psi. Pressurized sample
suspensions up to 35m1 are bled through a needle valve at a rate of about 1 ml/min. Because the process
generates heat, the sample, piston and cylinder are usually pre-cooled. Typical pressures used to disrupt yeast
are 8,000 to 10,000 psi and several passes through the press may be required for high efficiency of disruption.
Generally, the higher the pressure, the fewer the passes. Pressure cells rated at 20,000 psi maximum come in
capacities of 3.7 and 35m1 and there is also a 35m1 capacity cell rated at 40,000 psi.
Most high-pressure homogenizers used for homogenization were adapted from commercial equipment designed
to produce emulsions and homogenates in the food and pharmaceutical industries. They combine high pressure
with an impingement valve. Those with a maximum pressure rating of 10,000 psi rupture about 40% of the cells
on a single pass, 60% on the second pass, and 85% after four passes. Capacities of continuous homogenizers
vary from 55 to 4,500 liters/hr at 10-17% w/v cell concentrations. With the larger capacity machines several
passes are needed to achieve high yields of disruption. Considerable heat can be generated during operation of
these homogenizers and therefore a heat exchanger attached to the outlet port is essential.
a) ROTOR-STATOR HOMOGENIZERS
Rotor-stator homogenizers (also called colloid mills or Willems homogenizers) generally outperform
cutting blade-type blenders and are well suited for plant and animal tissue. Combined with glass beads, the
rotor-stator homogenizer has been successfully used to disrupt microorganisms. However, the homogenized
sample is contaminated with minute glass and stainless steel particles and the abrasive wear to the rotor-stator
homogenizer is unacceptably high. Cell disruption with the rotor-stator homogenizer involves hydraulic and
mechanical shear as well as cavitation. Some people in the homogenizing field also claim that there is to a lesser
extent high-energy sonic and ultrasonic pressure gradients involved.
While some do not believe in the theory that high-energy sonic and ultrasonic pressure gradients are
involved with mechanical homogenizers. The only thing that ultrasonic and mechanical (rotor-stator)
homogenizing have in common is that both methods generate and use to some degree cavitation. Cavitation is
defined as the formation and collapse of low-pressure vapor cavities in a flowing liquid. Cavitation is generated
as you move a solid object through a liquid at a high rate of speed. In ultrasonics the object being moved is the
probe which is being vibrated at a very high rate of speed generating cavitation. In mechanical homogenizing
(rotor-stator) the blade (rotor) is being moved through the liquid at a high rate of speed generating cavitation.
The rotor-stator generator type homogenizer was first developed to make dispersions and emulsions,
and most biological tissues are quickly and thoroughly homogenized with this apparatus. Appropriately sized
cellular material is drawn up into the apparatus by a rapidly rotating rotor (blade) positioned within a static head
or tube (stator) containing slots or holes. There the material is centrifugally thrown outward in a pump like
fashion to exit through the slots or holes. Because the rotor (blade) turns at a very high rpm, the tissue is rapidly
reduced in size by a combination of extreme turbulence, cavitation and scissor like mechanical shearing
occurring within the narrow gap between the rotor and the stator. Since most rotor-stator homogenizers have an
open configuration, the product is repeatedly recirculated. The process is fast and depending on the toughness of
the tissue sample, desired results will usually be obtained in 15-120 seconds. For the recovery of intracellular
organelles or receptor site complexes, shorter times are used and the rotor speed is reduced. The variables to be
optimized for maximum efficiency are as follows:
Design and size of rotor-stator (generator)
Rotor tip speed
Initial size of sample
Viscosity of medium
Time of processing or flow rate
Volume of medium and concentration of sample
Shape of vessel and positioning of rotor-stator
The size of the rotor-stator probe (also called generator) can vary from the diameter of a pencil for
0.01-10mI sample volumes to much larger units having batch capacities up to 19,000 liters or, for on-line units,
capabilities of 68,000 liters/hr. Rotor speeds vary from 3,000 rpm for large units to 8,000-60,000 rpm for the
smaller units. In principle, the rotor speed of the homogenizer should be doubled for each halving of the rotor
diameter. It is not the rpm's of the motor but the tip velocity of the rotor that is the important operating
International organization of Scientific Research 3|Page
Homogenization Fundamentals
parameter. Other factors such as rotor-stator design, which there are many, materials used in construction, and
ease of leaning are also important factors to consider in selecting a rotor-stator homogenizer.
Laboratory size rotor-stator homogenizers process liquid samples in the 0.01 ml to 20 liter range. The
capacity of the rotor-stator should be matched to the viscosity and volume of the medium and with the type and
amount of plant and animal tissue to be processed. The speed and efficiency of homogenization is greatly
degraded by using too small a homogenizer, and the volume range over which a given homogenizer rotor-stator
size will function efficiently is only about 10 fold. Also, most of the laboratory-sized homogenizers function
properly only with liquid samples in the low to medium viscosity range (<10,000 cps). This must be balanced
against the practical observation that concentratedsamples, by colliding more frequently, are broken up more
rapidly. Higher viscosity samples can be processed but require specially shaped homogenization vessels or
unique rotor-stator configurations. The size of the sample prior to processing with the homogenizer must be
small enough to be drawn inside the stator. Therefore, samples often must be pre-chopped, cut or fragmented.
Foaming and aerosols can be a problem with rotor-stator homogenizers. Keeping the tip of the homogenizer
well submerged within the media and the use of properly sized vessels helps with the first problem. Square-
shaped or fluted vessels give better results than round vessels and it is also beneficial to hold the immersed tip
off center. Aerosols can be minimized by using covered vessels.
There are no aerosols with in-line homogenizers. Even though a number of the laboratory rotor-stator
homogenizers use sealed motors, none of them are truly explosion-proof. Due caution should be followed when
using flammable organic solvents by conducting the homogenization in a well ventilated hood. On the positive
side, rotor-stator homogenizers generate minimal heat during operation and this can be easily dissipated by
cooling the homogenization vessel in ice water during processing.
The larger rotor-stator homogenizers are either scaled up versions of the laboratory models or in-line
homogenizers. The latter contain teeth on the edge of a horizontally oriented, multi-bladed, high-speed impeller
aligned in close tolerance to matching teeth in a static liner.
6) Applications of homogenization[3][5][6]
6.1) Food & Dairy Applications of Homogenization
Homogenization is the process of reducing the particle size of fluid products such as milk, fruit juice
and sauces, under conditions of extreme pressure, sheer, turbulence, acceleration and impact, to make them
more stable and have a better texture. The effect is achieved by forcing the product through a special
homogenizing valve at a very high pressure. Particles enter the homogenizer with sizes ranging typically from
0.2 - 20 microns. Large particles are dispersed to produce a product with particles ranging typically from 0.4 to
1 micron depending on the application
homogenization (also known as micronization) also ensures the most efficient use of the active agents, thus
reducing product costs.
Milk homogenization:-[2][4][7][10]
In food industry most prominent use of homogenizers is for milk homogenization.
7.1) Objectives:-
a) Counteracting segregation, for the most part creaming.-to achieve this, the size of the fat globules should be
greatly reduced. A cream layer or sediment in the product may be a nuisance for the user, especially if the
package is nontransparent.
b) improving stability towards partial coalescence.-the increased stability of homogenized fat globule is caused
by the reduced diameter and by the acquired surface layer of the fat globules. Moreover, partial coalescence
especially occurs in a cream layer and such a layer forms much more slowly in homogenized products. All in
all, prevention of partial coalescence usually is the most important purpose of homogenization.
To determine the ideal operating pressure of the homogenizer on a particular product, the first step is to
establish a method of evaluation. The method may be viscosity increase or decrease, average particle size (as
determined microscopically or by instrument), rate of separation, grind gauge or change in physical appearance,
just to mention a few. The next step is to collect samples from the homogenizer at different pressure settings; for
example, every 1000 psi (or less, if a narrow pressure range is being evaluated). Finally, using the appropriate
method of analysis, the evaluated parameter is compared or plotted versus homogenizing pressure and the
lowest pressure that generates the required product can then be selected. For some products it may be desirable
to determine the effect of multipassing at an appropriate pressure.
REFERENCES
[1] www.wikipedia.com
[2] www.horiba.com
[3] http://www.nirosoavi.com/industries-applications/food-dairy-applications-homogenization.asp
[4] http://www.foodscience.uoguelph.ca/dairyedu/homogenization.html
[5] http://www.nirosoavi.com/industries-applications/homogenization-cosmetic-pharma-biotech.asp
[6] http://www.nirosoavi.com/industries-applications/homogenization-chemical-processing.asp
[7] http://www.raw-milk-facts.com/homogenization_T3.html
[8] http://www.proscientific.com/
[9] http://www.proscientific.com/Homogenizing.shtml
[10] http://www.wisegeek.com/what-is-homogenization.htm