Design of Axially Loaded Column
Column size 300 X 450 mm
Load Acting on Column
Calculations
Thickness of slab= 0.15 m
Dead load of slab= 3.75 kN/m2 3.5 450
Dead load of finishing= 1.5 kN/m2 300
Live load= 5 kN/m 2
Total load on the column= 10.25 kN/m2
Area on which this load act 16.45 m2 4.7
Axial load acting on the co 168.613 kN
Total number of floors= 6
Total axial load on the col 1011.68 kN
say 1012 kN
Factored load= 1518 kN
Design of Reinforcement
Unsupported length of Col 3m
Minimum eccentricity emin= 21 OK
Slenderness Ratio= 6.66667 Short Column
Working Stress Method
2.909 % Steel
Using 8 bars of dia 25 mm
Area of longitudinal bars Asc= 3927 mm2
Area of Concrete Ac = 131073 mm2
Permissible stress in conc.in direct 6 N/mm2 M25 grade of concrete
Permissible comp stress for column b 190 N/mm2 FE415 grade of steel
Load carried by column= 1532.6 kN SAFE
Transverse Reinforcement Design
Diameter of links should not be less 7 mm
Use 10 mm dia links spacing 400 mm
400
480